메뉴 건너뛰기




Volumn 19, Issue 2, 2013, Pages 63-69

Detecting turn shorts in rotor windings: A new test using magnetic flux monitoring

Author keywords

[No Author keywords available]

Indexed keywords

AGING PROCESS; AIR SEPARATION; BEARING VIBRATIONS; BRUSHLESS MOTORS; COMPRESSOR MOTOR; ELECTRIC POWER RESEARCH INSTITUTE; HYDRO-GENERATORS; LOAD CYCLING; MACHINE FAILURE; MAGNETIC FLUX MONITORING; OFF-LINE METHODS; OFFLINE TEST; ROTOR WINDINGS; SALIENT POLES; SHORTED TURNS; STATOR CORE; SYNCHRONIZING SYSTEM; TURN INSULATIONS; VOLTAGE SIGNALS;

EID: 84873994428     PISSN: 10772618     EISSN: None     Source Type: Journal    
DOI: 10.1109/MIAS.2012.2215644     Document Type: Article
Times cited : (39)

References (5)
  • 2
    • 0015023031 scopus 로고
    • Interturn short-circuit detector for turbine-generator rotor windings
    • Mar./Apr.
    • D. R. Albright, "interturn short-circuit detector for turbine-generator rotor windings," IEEE Trans. Power Apparatus Syst., vol. PAs-90, no. 2, pp. 478-483, Mar./Apr. 1971.
    • (1971) IEEE Trans. Power Apparatus Syst. , vol.PAS-90 , Issue.2 , pp. 478-483
    • Albright, D.R.1
  • 3
    • 84876758466 scopus 로고    scopus 로고
    • Detection of rotor winding shorted turns in turbine generators and hydrogenera-tors
    • Aug.
    • S. R. Campbell, J. Kapler, M. sasic, and g. C. stone, "detection of rotor winding shorted turns in turbine generators and hydrogenera-tors," in Proc. CIGRE, paper A1-206, Aug. 2010.
    • (2010) Proc. CIGRE, Paper A1-206
    • Campbell, S.R.1    Kapler, J.2    Sasic, M.3    Stone, G.C.4
  • 5
    • 77957551458 scopus 로고    scopus 로고
    • U.S. Bureau Of Reclamation U.s. Patent 6 466 009 B1, oct. 15
    • U.S. Bureau of reclamation, "flexible printed circuit magnetic flux probe," U.s. Patent 6 466 009 B1, oct. 15, 2002.
    • (2002) Flexible Printed Circuit Magnetic Flux Probe


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.