메뉴 건너뛰기




Volumn 22, Issue 1, 2013, Pages 68-76

Thermal extractor analysis of VOCs emitted from building materials and evaluation of the reduction performance of exfoliated graphite nanoplatelets

Author keywords

Graphite; Porous; Thermal extractor; VOCs; xGnP

Indexed keywords

GRAPHITE; VOLATILE ORGANIC COMPOUND;

EID: 84873970670     PISSN: 1420326X     EISSN: 14230070     Source Type: Journal    
DOI: 10.1177/1420326X12470411     Document Type: Article
Times cited : (5)

References (29)
  • 1
    • 0036676989 scopus 로고    scopus 로고
    • Indoor environmental exposures and symptoms
    • Hodgson M. Indoor environmental exposures and symptoms. Environ Health Perspect. 2002 ; 110: 663-667
    • (2002) Environ Health Perspect , vol.110 , pp. 663-667
    • Hodgson, M.1
  • 2
    • 0030657541 scopus 로고    scopus 로고
    • Building-related illnesses
    • Menzies D, Bourbeau J. Building-related illnesses. N Engl J Med. 1997 ; 337 (21). 1524-1531
    • (1997) N Engl J Med , vol.337 , Issue.21 , pp. 1524-1531
    • Menzies, D.1    Bourbeau, J.2
  • 3
    • 34249658307 scopus 로고    scopus 로고
    • Subacute toxicity evaluation in rats exposed to concrete and hwangto building environments
    • Lee S, Yang Y, Ahn T, Bae C, Moon C, Kim S, Song S, Hwang H, Kim J. Subacute toxicity evaluation in rats exposed to concrete and hwangto building environments. Environ Toxicol. 2007 ; 22 (3). 264-274
    • (2007) Environ Toxicol , vol.22 , Issue.3 , pp. 264-274
    • Lee, S.1    Yang, Y.2    Ahn, T.3    Bae, C.4    Moon, C.5    Kim, S.6    Song, S.7    Hwang, H.8    Kim, J.9
  • 4
    • 84857045282 scopus 로고    scopus 로고
    • A finish material management system for indoor air quality of apartment buildings (FinIAQ)
    • Lee S, Kwon G, Joo J, Kim JT, Kim S. A finish material management system for indoor air quality of apartment buildings (FinIAQ). Energy Build. 2012 ; 46: 68-79
    • (2012) Energy Build , vol.46 , pp. 68-79
    • Lee, S.1    Kwon, G.2    Joo, J.3    Kim, J.T.4    Kim, S.5
  • 5
    • 13944258496 scopus 로고    scopus 로고
    • Emissions of volatile organic compounds from several green and non-green building materials. A comparison
    • James JP, Yang X. Emissions of volatile organic compounds from several green and non-green building materials. a comparison: Indoor Built Environ. 2005 ; 14 (1). 69-74
    • (2005) Indoor Built Environ , vol.14 , Issue.1 , pp. 69-74
    • James, J.P.1    Yang, X.2
  • 6
    • 0141670501 scopus 로고    scopus 로고
    • Characteristics and correlations of VOC emissions from building materials
    • Zhang Y, Xu Y. Characteristics and correlations of VOC emissions from building materials. Int J Heat Mass Transfer. 2003 ; 46 (25). 4877-4883
    • (2003) Int J Heat Mass Transfer , vol.46 , Issue.25 , pp. 4877-4883
    • Zhang, Y.1    Xu, Y.2
  • 7
    • 77949615792 scopus 로고    scopus 로고
    • Building pathology, investigation of sick buildings - VOC emissions
    • Yu CWF, Kim JT. Building pathology, investigation of sick buildings - VOC emissions. Indoor Built Environ. 2010 ; 19 (1). 30-39
    • (2010) Indoor Built Environ , vol.19 , Issue.1 , pp. 30-39
    • Yu, C.W.F.1    Kim, J.T.2
  • 8
    • 84859055176 scopus 로고    scopus 로고
    • Long-term impact of formaldehyde and VOC emissions from wood-based products on indoor environments; And issues with recycled products
    • Yu CWF, Kim JT. Long-term impact of formaldehyde and VOC emissions from wood-based products on indoor environments; and issues with recycled products. Indoor Built Environ. 2012 ; 21 (1). 137-149
    • (2012) Indoor Built Environ , vol.21 , Issue.1 , pp. 137-149
    • Yu, C.W.F.1    Kim, J.T.2
  • 9
    • 0036134984 scopus 로고    scopus 로고
    • The effect of temperature on the emission of formaldehyde and volatile organic compounds (VOCs) from laminate flooring - Case study
    • Wiglusz R, Sitko E, Nikel G, Jarnuszkiewicz I, Igielska B. The effect of temperature on the emission of formaldehyde and volatile organic compounds (VOCs) from laminate flooring - case study. Build Environ. 2002 ; 37 (1). 41-44
    • (2002) Build Environ , vol.37 , Issue.1 , pp. 41-44
    • Wiglusz, R.1    Sitko, E.2    Nikel, G.3    Jarnuszkiewicz, I.4    Igielska, B.5
  • 10
    • 24044445190 scopus 로고    scopus 로고
    • Comparison of formaldehyde emission from building finishing materials at various temperatures in under heating system; ONDOL
    • Kim S, Kim H. Comparison of formaldehyde emission from building finishing materials at various temperatures in under heating system; ONDOL. Indoor Air. 2005 ; 15 (5). 317-325
    • (2005) Indoor Air , vol.15 , Issue.5 , pp. 317-325
    • Kim, S.1    Kim, H.2
  • 11
    • 34047154661 scopus 로고    scopus 로고
    • Influence of temperature on formaldehyde emission parameters of dry building materials
    • Zhang Y, Luo X, Wang X, Qian K, Zhao R. Influence of temperature on formaldehyde emission parameters of dry building materials. Atmos Environ. 2007 ; 41 (15). 3203-3216
    • (2007) Atmos Environ , vol.41 , Issue.15 , pp. 3203-3216
    • Zhang, Y.1    Luo, X.2    Wang, X.3    Qian, K.4    Zhao, R.5
  • 12
    • 0035311792 scopus 로고    scopus 로고
    • Effects of pore structure and temperature on VOC adsorption on activated carbon
    • Chiang Y, Chiang P, Huang C. Effects of pore structure and temperature on VOC adsorption on activated carbon. Carbon. 2001 ; 39 (4). 523-534
    • (2001) Carbon , vol.39 , Issue.4 , pp. 523-534
    • Chiang, Y.1    Chiang, P.2    Huang, C.3
  • 13
    • 77955878439 scopus 로고    scopus 로고
    • The impact of a non-adhesive floating installation method on emissions and indoor concentrations of VOCs
    • Choi DH, Kang DH, Kim SS, Yeo MS, Kim KW. The impact of a non-adhesive floating installation method on emissions and indoor concentrations of VOCs. Indoor Built Environ. 2010 ; 19 (4). 435-443
    • (2010) Indoor Built Environ , vol.19 , Issue.4 , pp. 435-443
    • Choi, D.H.1    Kang, D.H.2    Kim, S.S.3    Yeo, M.S.4    Kim, K.W.5
  • 14
    • 77950865706 scopus 로고    scopus 로고
    • Effect of bake-out on reducing VOC emissions and concentrations in a residential housing unit with a radiant floor heating system
    • Kang DH, Choi DH, Lee SM, Yeo MS, Kim KW. Effect of bake-out on reducing VOC emissions and concentrations in a residential housing unit with a radiant floor heating system. Building Environ. 2010 ; 45 (8). 1816-1825
    • (2010) Building Environ , vol.45 , Issue.8 , pp. 1816-1825
    • Kang, D.H.1    Choi, D.H.2    Lee, S.M.3    Yeo, M.S.4    Kim, K.W.5
  • 15
    • 0037503228 scopus 로고    scopus 로고
    • Historical changes and recent energy saving potential of residential heating in Korea
    • Yeo MS, Yang IH, Kim KW. Historical changes and recent energy saving potential of residential heating in Korea. Energy Build. 2003 ; 35 (7). 15-27
    • (2003) Energy Build , vol.35 , Issue.7 , pp. 15-27
    • Yeo, M.S.1    Yang, I.H.2    Kim, K.W.3
  • 16
    • 4944253506 scopus 로고
    • Thermal comfort criteria for Korean people in Ondol heating system
    • Kong SH, Sohn JY. Thermal comfort criteria for Korean people in Ondol heating system. J Archit Inst Korea. 1988 ; 4: 167-175
    • (1988) J Archit Inst Korea , vol.4 , pp. 167-175
    • Kong, S.H.1    Sohn, J.Y.2
  • 17
    • 4944255825 scopus 로고
    • Optimum comfort limits determination through the characteristics of asymmetric thermal radiation in a radiant heating space, "oNDOL
    • Yoon YJ, Park SD, Shon JY. Optimum comfort limits determination through the characteristics of asymmetric thermal radiation in a radiant heating space, "ONDOL. J Archit Inst Korea. 1991 ; 7: 211-219
    • (1991) J Archit Inst Korea , vol.7 , pp. 211-219
    • Yoon, Y.J.1    Park, S.D.2    Shon, J.Y.3
  • 18
    • 77955871146 scopus 로고    scopus 로고
    • Influence of environmental factors on performance of sorptive building materials
    • Seo J, Kato S, Ataka Y, Yang J-H. Influence of environmental factors on performance of sorptive building materials. Indoor Built Environ. 2010 ; 19 (4). 413-421
    • (2010) Indoor Built Environ , vol.19 , Issue.4 , pp. 413-421
    • Seo, J.1    Kato, S.2    Ataka, Y.3    Yang, J.-H.4
  • 19
    • 71149118221 scopus 로고    scopus 로고
    • Characterization of mesoporous activated carbons prepared by pyrolysis of sewage sludge with pyrolusite
    • Liu C, Tang Z, Chen Y, Su S, Jiang W. Characterization of mesoporous activated carbons prepared by pyrolysis of sewage sludge with pyrolusite. Bioresour Technol. 2010 ; 101 (3). 1097-1101
    • (2010) Bioresour Technol , vol.101 , Issue.3 , pp. 1097-1101
    • Liu, C.1    Tang, Z.2    Chen, Y.3    Su, S.4    Jiang, W.5
  • 20
    • 17744383575 scopus 로고    scopus 로고
    • Effects of pore structure and surface state on the adsorption properties of nano-porous carbon materials in low and high relative pressures
    • Lee WH, Park JS, Sok JH, Reucroft PJ. Effects of pore structure and surface state on the adsorption properties of nano-porous carbon materials in low and high relative pressures. Appl Surf Sci. 2005 ; 246 (1-3). 77-81
    • (2005) Appl Surf Sci , vol.246 , Issue.13 , pp. 77-81
    • Lee, W.H.1    Park, J.S.2    Sok, J.H.3    Reucroft, P.J.4
  • 21
    • 55949105201 scopus 로고    scopus 로고
    • High latent heat storage and high thermal conductive phase change materials using exfoliated graphite nano platelets
    • Kim S, Drzal LT. High latent heat storage and high thermal conductive phase change materials using exfoliated graphite nano platelets. Sol Energy Mater Sol Cell. 2009 ; 93 (1). 136-142
    • (2009) Sol Energy Mater Sol Cell , vol.93 , Issue.1 , pp. 136-142
    • Kim, S.1    Drzal, L.T.2
  • 22
    • 84861835196 scopus 로고    scopus 로고
    • Enhancement of the thermal conductivity of adhesives for wood flooring using xGnP
    • Seo J, Cha J, Kim S. Enhancement of the thermal conductivity of adhesives for wood flooring using xGnP. Energy Build. 2012 ; 51 (0). 153-156
    • (2012) Energy Build , vol.51 , pp. 153-156
    • Seo, J.1    Cha, J.2    Kim, S.3
  • 23
    • 33746343707 scopus 로고    scopus 로고
    • Determination of formaldehyde and TVOC emission factor from wood-based composites by small chamber method
    • Kim S, Kim J, Kim H, Do Kim S. Determination of formaldehyde and TVOC emission factor from wood-based composites by small chamber method. Polym Test. 2006 ; 25 (5). 605-614
    • (2006) Polym Test , vol.25 , Issue.5 , pp. 605-614
    • Kim, S.1    Kim, J.2    Kim, H.3    Do Kim, S.4
  • 24
    • 84857048389 scopus 로고    scopus 로고
    • The determination of the adsorption performance of graphite for VOCs and formaldehyde
    • Lee J, Kim S. The determination of the adsorption performance of graphite for VOCs and formaldehyde. Energy Build. 2012 ; 46 (0). 56-61
    • (2012) Energy Build , vol.46 , pp. 56-61
    • Lee, J.1    Kim, S.2
  • 25
    • 0035450515 scopus 로고    scopus 로고
    • Preparation of polystyrene-graphite conducting nanocomposites via intercalation polymerization
    • Chen GH, Wu DJ, Weng WG, He B, Yan WL. Preparation of polystyrene-graphite conducting nanocomposites via intercalation polymerization. Polym Int. 2001 ; 50 (9). 980-985
    • (2001) Polym Int , vol.50 , Issue.9 , pp. 980-985
    • Chen, G.H.1    Wu, D.J.2    Weng, W.G.3    He, B.4    Yan, W.L.5
  • 26
    • 0033745606 scopus 로고    scopus 로고
    • New process of fabricating electrically conducting nylon 6/graphite nanocomposites via intercalation polymerization
    • Pan YX, Yu ZZ, Ou YC, Hu GH. New process of fabricating electrically conducting nylon 6/graphite nanocomposites via intercalation polymerization: Polym Sci B: Polym Phys. 2000 ; 38 (12). 1626-1633
    • (2000) Polym Sci B: Polym Phys. , vol.38 , Issue.12 , pp. 1626-1633
    • Pan, Y.X.1    Yu, Z.Z.2    Ou, Y.C.3    Hu, G.H.4
  • 29
    • 0027607442 scopus 로고
    • Indoor air pollution by organic emissions from textile floor coverings. Climate chamber studies under dynamic conditions: Atmos Environ Part B
    • Sollinger S, Levsen K, Wünsch G. Indoor air pollution by organic emissions from textile floor coverings. Climate chamber studies under dynamic conditions: Atmos Environ Part B. Urban Atmos. 1993 ; 27 (2). 183-192
    • (1993) Urban Atmos , vol.27 , Issue.2 , pp. 183-192
    • Sollinger, S.1    Levsen, K.2    Wünsch, G.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.