메뉴 건너뛰기




Volumn 193, Issue , 2013, Pages 54-58

Development of a multilayer microfluidic device integrated with a PDMS-cellulose composite film for sample pre-treatment and immunoassay

Author keywords

Composite film; Integration; Microfluidics; Surface modification

Indexed keywords

BONDING STRENGTH; CLINICAL SAMPLES; CORRELATION COEFFICIENT; CROSS FLOWS; DETECTION RANGE; DIPCOATING METHODS; HUMAN IGG; HUMAN IMMUNOGLOBULIN; INTEGRATED MICROFLUIDIC DEVICES; INTEGRATED MULTILAYERS; MICRO-FLUIDIC DEVICES; ON-SITE DETECTION; PLATFORM TECHNOLOGY; POLYDIMETHYLSILOXANE PDMS; RAT WHOLE BLOOD; SAMPLE PRETREATMENT; URINE SAMPLE;

EID: 84873845480     PISSN: 09244247     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.sna.2013.01.004     Document Type: Article
Times cited : (10)

References (21)
  • 1
    • 0036267266 scopus 로고    scopus 로고
    • Microfluidic technologies in clinical diagnostics
    • DOI 10.1016/S0009-8981(02)00093-1, PII S0009898102000931
    • T.H. Schulte, R.L. Bardell, and B.H. Weigl Microfluidic technologies in clinical diagnostics Clinica Chimica Acta 321 2002 1 10 (Pubitemid 34597045)
    • (2002) Clinica Chimica Acta , vol.321 , Issue.1-2 , pp. 1-10
    • Schulte, T.H.1    Bardell, R.L.2    Weigl, B.H.3
  • 2
    • 33747117373 scopus 로고    scopus 로고
    • The origins and the future of microfluidics
    • DOI 10.1038/nature05058, PII NATURE05058
    • G.M. Whitesides The origins and the future of microfluidics Nature 442 2006 368 373 (Pubitemid 44264779)
    • (2006) Nature , vol.442 , Issue.7101 , pp. 368-373
    • Whitesides, G.M.1
  • 6
    • 84865646709 scopus 로고    scopus 로고
    • Electromechanical biosensors for pathogen detection
    • S. Xu Electromechanical biosensors for pathogen detection Microchimica Acta 178 2012 245 260
    • (2012) Microchimica Acta , vol.178 , pp. 245-260
    • Xu, S.1
  • 7
    • 84865297464 scopus 로고    scopus 로고
    • On-chip bioanalysis with magnetic particles
    • N. Pamme On-chip bioanalysis with magnetic particles Current Opinion in Chemical Biology 16 2012 436 443
    • (2012) Current Opinion in Chemical Biology , vol.16 , pp. 436-443
    • Pamme, N.1
  • 8
    • 79952630631 scopus 로고    scopus 로고
    • Nanoparticle-based electrochemical detection in conventional and miniaturized systems and their bioanalytical applications: A review
    • W. Siangproh, W. Dungchai, P. Rattanarat, and O. Chailapakul Nanoparticle-based electrochemical detection in conventional and miniaturized systems and their bioanalytical applications: a review Analytica Chimica Acta 690 2011 10 25
    • (2011) Analytica Chimica Acta , vol.690 , pp. 10-25
    • Siangproh, W.1    Dungchai, W.2    Rattanarat, P.3    Chailapakul, O.4
  • 9
    • 0036643808 scopus 로고    scopus 로고
    • PDMS-based microfluidic devices for biomedical applications
    • DOI 10.1016/S0167-9317(02)00494-X, PII S016793170200494X
    • T. Fujii PDMS-based microfluidic devices for biomedical applications Microelectronic Engineering 61 2002 907 914 (Pubitemid 34613463)
    • (2002) Microelectronic Engineering , vol.61-62 , pp. 907-914
    • Fujii, T.1
  • 10
    • 0032521325 scopus 로고    scopus 로고
    • Integrated cell isolation and polymerase chain reaction analysis using silicon microfilter chambers
    • DOI 10.1006/abio.1997.2530
    • P. Wilding, L.J. Kricka, J. Cheng, G. Hvichia, M.A. Shoffner, and P. Fortina Integrated cell isolation and polymerase chain reaction analysis using silicon microfilter chambers Analytical Biochemistry 257 1998 95 100 (Pubitemid 28128969)
    • (1998) Analytical Biochemistry , vol.257 , Issue.2 , pp. 95-100
    • Wilding, P.1    Kricka, L.J.2    Cheng, J.3    Hvichia, G.4    Shoffner, M.A.5    Fortina, P.6
  • 11
    • 33244491475 scopus 로고    scopus 로고
    • A hybrid poly(dimethylsiloxane) microsystem for on-chip whole blood filtration optimized for steroid screening
    • DOI 10.1007/s10544-006-6385-7
    • S. Thorslund, O. Klett, F. Nikolajeff, K. Markides, and J. Bergquist A hybrid poly(dimethylsiloxane) microsystem for on-chip whole blood filtration optimized for steroid screening Biomedical Microdevices 8 2006 73 79 (Pubitemid 43280430)
    • (2006) Biomedical Microdevices , vol.8 , Issue.1 , pp. 73-79
    • Thorslund, S.1    Klett, O.2    Nikolajeff, F.3    Markides, K.4    Bergquist, J.5
  • 12
    • 18944373118 scopus 로고    scopus 로고
    • Monolithic stationary phases for capillary electrochromatography based on synthetic polymers: Designs and applications
    • DOI 10.1002/(SICI)1521-4168(20000101)23:1<3::AID-JHRC3>3.0.CO;2-H
    • F. Svec, E. Peters, D. Sykora, C. Yu, and J. Frechet Monolithic stationary phases for capillary electrochromatography based on synthetic polymers: designs and applications Journal of High Resolution Chromatography 23 2000 3 18 (Pubitemid 30105356)
    • (2000) HRC Journal of High Resolution Chromatography , vol.23 , Issue.1 , pp. 3-18
    • Svec, F.1    Peters, E.C.2    Sykora, D.3    Yu, C.4    Frechet, J.M.J.5
  • 15
    • 24744443495 scopus 로고    scopus 로고
    • Isolation of plasma from whole blood using planar microfilters for lab-on-a-chip applications
    • DOI 10.1039/b502930a
    • T.A. Crowley, and V. Pizziconi Isolation of plasma from whole blood using planar microfilters for lab-on-a-chip applications Lab on a Chip 5 2005 922 929 (Pubitemid 41297845)
    • (2005) Lab on a Chip - Miniaturisation for Chemistry and Biology , vol.5 , Issue.9 , pp. 922-929
    • Crowley, T.A.1    Pizziconi, V.2
  • 16
    • 33846551257 scopus 로고    scopus 로고
    • Continuous flow microfluidic device for cell separation, cell lysis and DNA purification
    • DOI 10.1016/j.aca.2006.11.057, PII S0003267006022197
    • X. Chen, D. Cui, C. Liu, H. Li, and J. Chen Continuous flow microfluidic device for cell separation, cell lysis and DNA purification Analytica Chimica Acta 584 2007 237 243 (Pubitemid 46161304)
    • (2007) Analytica Chimica Acta , vol.584 , Issue.2 , pp. 237-243
    • Chen, X.1    Cui, D.2    Liu, C.3    Li, H.4    Chen, J.5
  • 17
    • 59849123587 scopus 로고    scopus 로고
    • Isolation of plasma from whole blood using a microfludic chip in a continuous cross-flow
    • X. Chen, D.F. Cui, and L.L. Zhang Isolation of plasma from whole blood using a microfludic chip in a continuous cross-flow Chinese Science Bulletin 54 2009 324 327
    • (2009) Chinese Science Bulletin , vol.54 , pp. 324-327
    • Chen, X.1    Cui, D.F.2    Zhang, L.L.3
  • 18
    • 80051638368 scopus 로고    scopus 로고
    • Microfiltration platform for continuous blood plasma protein extraction from whole blood during cardiac surgery
    • K. Aran, A. Fok, L.A. Sasso, N. Kamdar, Y. Guan, Q. Sun, A. Undar, and J.D. Zahn Microfiltration platform for continuous blood plasma protein extraction from whole blood during cardiac surgery Lab on a Chip 11 2011 2858 2868
    • (2011) Lab on A Chip , vol.11 , pp. 2858-2868
    • Aran, K.1    Fok, A.2    Sasso, L.A.3    Kamdar, N.4    Guan, Y.5    Sun, Q.6    Undar, A.7    Zahn, J.D.8
  • 19
    • 33746729444 scopus 로고    scopus 로고
    • A rigid poly(dimethylsiloxane) sandwich electrophoresis microchip based on thin-casting method
    • DOI 10.1002/elps.200500581
    • C. Liu, D. Cui, H. Cai, X. Chen, and Z. Geng A rigid poly(dimethylsiloxane) sandwich electrophoresis microchip based on thin-casting method Electrophoresis 27 2006 2917 2923 (Pubitemid 44160842)
    • (2006) Electrophoresis , vol.27 , Issue.14 , pp. 2917-2923
    • Liu, C.1    Cui, D.2    Cai, H.3    Chen, X.4    Geng, Z.5
  • 20
    • 84866037979 scopus 로고    scopus 로고
    • Hydrophilic property of 316L stainless steel after treatment by atmospheric pressure corona streamer plasma using surface-sensitive analyses
    • I. Al-Hamarneha, P. Pedrowb, A. Eskhanc, and N. Abu-Lailc Hydrophilic property of 316L stainless steel after treatment by atmospheric pressure corona streamer plasma using surface-sensitive analyses Applied Surface Science 259 2012 424 432
    • (2012) Applied Surface Science , vol.259 , pp. 424-432
    • Al-Hamarneha, I.1    Pedrowb, P.2    Eskhanc, A.3    Abu-Lailc, N.4
  • 21
    • 78049468411 scopus 로고    scopus 로고
    • Microfluidics-based immunoassays by using an integrated fluorescence detection system
    • X. Chen, D. Cui, H. Li, H. Cai, J. Sun, and J. Chen Microfluidics-based immunoassays by using an integrated fluorescence detection system Microsystem Technologies 16 2010 2049 2055
    • (2010) Microsystem Technologies , vol.16 , pp. 2049-2055
    • Chen, X.1    Cui, D.2    Li, H.3    Cai, H.4    Sun, J.5    Chen, J.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.