메뉴 건너뛰기




Volumn 23, Issue 3, 2013, Pages

Microtesla NMR and high resolution MR imaging using high-Tc SQUIDs

Author keywords

Flux coupling; nuclear magnetic resonance magnetic resonance imaging (NMR MRI); superconducting quantum interference device (SQUID)

Indexed keywords

FIELD INHOMOGENEITY; FLUX COUPLING; HIGH RESOLUTION; HIGH-T; IMAGING QUALITY; LOW FIELD; LOW FIELD MRI; MAGNETIC RESONANCE IMAGING (MRI); MR IMAGING; NARROW-LINE WIDTH; NMR SPECTRUM; NUCLEAR MAGNETIC RESONANCE(NMR); TRIFLUOROETHANOL; TRIMETHYL PHOSPHATE;

EID: 84873694187     PISSN: 10518223     EISSN: None     Source Type: Journal    
DOI: 10.1109/TASC.2013.2237732     Document Type: Article
Times cited : (6)

References (20)
  • 1
    • 33748320911 scopus 로고    scopus 로고
    • Optical detection of liquidstate NMR
    • I.M. Savukov, S.-K. Lee, andM. V. Romalis, "Optical detection of liquidstate NMR," Nature, vol. 442, p. 1021, 2006.
    • (2006) Nature , vol.442 , pp. 1021
    • Savukov, I.M.1    Lee, S.-K.2    Romalis, M.V.3
  • 2
    • 18144414667 scopus 로고    scopus 로고
    • NMR detection with an atomic magnetometer
    • I. M. Savukov and M. V. Romalis, "NMR detection with an atomic magnetometer," Phys. Rev. Lett., vol. 94, p. 123001, 2005.
    • (2005) Phys. Rev. Lett , vol.94 , pp. 123001
    • Savukov, I.M.1    Romalis, M.V.2
  • 3
    • 34047164912 scopus 로고    scopus 로고
    • Optical magnetometry
    • D. Budker and M. Romalis, "Optical magnetometry," Nat. Phys., vol. 3, p. 227, 2007.
    • (2007) Nat. Phys , vol.3 , pp. 227
    • Budker, D.1    Romalis, M.2
  • 4
    • 33748038363 scopus 로고    scopus 로고
    • Magnetic resonance imaging with an optical atomic magnetometer,"
    • S. Xu et al., "Magnetic resonance imaging with an optical atomic magnetometer," Proc. Nat. Acad. Sci., vol. 103, p. 12668, 2006.
    • (2006) Proc. Nat. Acad. Sci , vol.103 , pp. 12668
    • Xu, S.1
  • 6
    • 33747870744 scopus 로고    scopus 로고
    • Construction and applications of an atomic magnetic gradiometer based on nonlinear magneto-optical rotation
    • S. Xu, S. M. Rochester, V. V. Yashchuk, M. H. Donaldson, and D. Budker, "Construction and applications of an atomic magnetic gradiometer based on nonlinear magneto-optical rotation," Rev. Sci. Instrum., vol. 77, p. 089106, 2006.
    • (2006) Rev. Sci. Instrum., Vol , vol.77 , pp. 089106
    • Xu, S.1    Rochester, S.M.2    Yashchuk, V.V.3    Donaldson, M.H.4    Budker, D.5
  • 7
    • 0032345068 scopus 로고    scopus 로고
    • Application of superconducting quantum interference devices to nuclear magnetic resonance
    • Y. S. Greenberg, "Application of superconducting quantum interference devices to nuclear magnetic resonance," Rev. Mod. Phys., vol. 70, p. 175, 2002.
    • (2002) Rev. Mod. Phys , vol.70 , pp. 175
    • Greenberg, Y.S.1
  • 9
    • 34247893994 scopus 로고    scopus 로고
    • Liquid state nuclear magnetic resonance at low fields using a nitrogen cooled superconducting quantum interference device
    • Y. Zhang, L. Qiu, H. Krause, S. Hartiwig, M. Burghoff, and L. Trahms, "Liquid state nuclear magnetic resonance at low fields using a nitrogen cooled superconducting quantum interference device," Appl. Phys. Lett., vol. 90, p. 182503, 2007.
    • (2007) Appl. Phys. Lett , vol.90 , pp. 182503
    • Zhang, Y.1    Qiu, L.2    Krause, H.3    Hartiwig, S.4    Burghoff, M.5    Trahms, L.6
  • 10
    • 0000822131 scopus 로고    scopus 로고
    • Low-field magnetic resonance imaging with a high- Tc dc superconducting quantum interference device
    • K. Schlenga, R. McDermott, J. Clarke, R. E. de Souza, A. Wong-Foy, and A. Pines, "Low-field magnetic resonance imaging with a high- Tc dc superconducting quantum interference device," Appl. Phys. Lett., vol. 75, p. 3695, 1999.
    • (1999) Appl. Phys. Lett , vol.75 , pp. 3695
    • Schlenga, K.1    McDermott, R.2    Clarke, J.3    De Souza, R.E.4    Wong-Foy, A.5    Pines, A.6
  • 11
    • 33745466335 scopus 로고    scopus 로고
    • Enhancement of nuclear magnetic resonance in microtesla magnetic field with prepolarization field detected with high-Tc superconducting quantum interference device
    • H. C. Yang, S. H. Liao, H. E. Horng, S. L. Kuo, H. H. Chen, and S. Y. Yang, "Enhancement of nuclear magnetic resonance in microtesla magnetic field with prepolarization field detected with high-Tc superconducting quantum interference device," Appl. Phys. Lett., vol. 88, p. 252505, 2006.
    • (2006) Appl. Phys. Lett , vol.88 , pp. 252505
    • Yang, H.C.1    Liao, S.H.2    Horng, H.E.3    Kuo, S.L.4    Chen, H.H.5    Yang, S.Y.6
  • 13
    • 34548022858 scopus 로고    scopus 로고
    • Nuclear magnetic resonance in the earth's magnetic field using a nitrogen-cooled superconducting quantum interference device
    • L. Qiu, Y. Zhang, H. J. Krause, A. H. Braginski, M. Burghoff, and L. Trahms, "Nuclear magnetic resonance in the earth's magnetic field using a nitrogen-cooled superconducting quantum interference device," Appl. Phys. Lett., vol. 91, p. 072505, 2007.
    • (2007) Appl. Phys. Lett , vol.91 , pp. 072505
    • Qiu, L.1    Zhang, Y.2    Krause, H.J.3    Braginski, A.H.4    Burghoff, M.5    Trahms, L.6
  • 14
    • 34548020005 scopus 로고    scopus 로고
    • Longitudinal relaxation time detection using a high-Tc superconductive quantum interference device magnetometer
    • S. H. Liao, H. E. Horng, H. C. Yang, and S. Y. Yang, "Longitudinal relaxation time detection using a high-Tc superconductive quantum interference device magnetometer," J. Appl. Phys., vol. 102, p. 033914, 2007.
    • (2007) J. Appl. Phys , vol.102 , pp. 033914
    • Liao, S.H.1    Horng, H.E.2    Yang, H.C.3    Yang, S.Y.4
  • 16
    • 67650742088 scopus 로고    scopus 로고
    • Sensitive J-coupling spectroscopy using high-Tc superconducting quantum interference devices in magnetic fields as low as microteslas
    • S. H. Liao, H. C. Yang, H. E. Horng, S. Y. Yang, H. H. Chen, D.W. Hwang, and L. P. Hwang, "Sensitive J-coupling spectroscopy using high-Tc superconducting quantum interference devices in magnetic fields as low as microteslas," Supercond. Sci. Technol., vol. 22, p. 045008, 2009.
    • (2009) Supercond. Sci. Technol , vol.22 , pp. 045008
    • Liao, S.H.1    Yang, H.C.2    Horng, H.E.3    Yang, S.Y.4    Chen, H.H.5    Hwang, D.W.6    Hwang, L.P.7
  • 17
    • 65249170076 scopus 로고    scopus 로고
    • Characterization of magnetic nanoparticles as contrast agents in magnetic resonance imaging using high-Tc superconducting quantum interference devices in microtesla magnetic fields
    • S. H. Liao, H. C. Yang, H. E. Horng, and S. Y. Yang, " Characterization of magnetic nanoparticles as contrast agents in magnetic resonance imaging using high-Tc superconducting quantum interference devices in microtesla magnetic fields," Supercond. Sci. Technol., vol. 22, p. 025003, 2009.
    • (2009) Supercond. Sci. Technol , vol.22 , pp. 025003
    • Liao, S.H.1    Yang, H.C.2    Horng, H.E.3    Yang, S.Y.4
  • 18
    • 0035579286 scopus 로고    scopus 로고
    • An introduction to hydrogen bond scalar couplings
    • A. J. Dingley, F. Cordier, and S. Grzesiek, "An introduction to hydrogen bond scalar couplings," Concepts Magn. Reson., vol. 13, p. 103, 2001.
    • (2001) Concepts Magn. Reson , vol.13 , pp. 103
    • Dingley, A.J.1    Cordier, F.2    Grzesiek, S.3
  • 19
    • 34249934069 scopus 로고    scopus 로고
    • Calculated signal-to-noise ratio of MRI detected with SQUIDs and Faraday detectors in fields from 10 μt to 1.5 T
    • W. Myers, D. Slichter, M. Hatridge, S. Busch, M. Mößle, R. McDermott, A. Trabesinger, and J. Clarke, "Calculated signal-to-noise ratio of MRI detected with SQUIDs and Faraday detectors in fields from 10 μT to 1.5 T," J. Magn. Reson., vol. 186, p. 182, 2007.
    • (2007) J. Magn. Reson , vol.186 , pp. 182
    • Myers, W.1    Slichter, D.2    Hatridge, M.3    Busch, S.4    Mößle, M.5    McDermott, R.6    Trabesinger, A.7    Clarke, J.8


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.