메뉴 건너뛰기




Volumn 34, Issue 1, 2013, Pages 153-158

Experimental evaluation of immediate recanalization effect and recanalization efficacy of a new thrombus retriever for acute stroke treatment in vivo

Author keywords

[No Author keywords available]

Indexed keywords

ANIMAL EXPERIMENT; ANIMAL MODEL; ARTICLE; BALLOON CATHETER; CEREBROVASCULAR ACCIDENT; EMBEDDING; IN VIVO STUDY; NITINOL STENT; NONHUMAN; PATIENT SAFETY; RECANALIZATION; THROMBECTOMY; THROMBOEMBOLISM; THROMBUS; THROMBUS RETRIEVER;

EID: 84873650515     PISSN: 01956108     EISSN: 1936959X     Source Type: Journal    
DOI: 10.3174/ajnr.A3275     Document Type: Article
Times cited : (21)

References (18)
  • 1
    • 77955171654 scopus 로고    scopus 로고
    • Mechanical thrombectomy with the Solitaire AB device in large artery occlusions of the anterior circulation: A pilot study
    • Castaño C, Dorado L, Guerrero C, et al. Mechanical thrombectomy with the Solitaire AB device in large artery occlusions of the anterior circulation: a pilot study. Stroke 2010;41:1836-40
    • (2010) Stroke , vol.41 , pp. 1836-1840
    • Castaño, C.1    Dorado, L.2    Guerrero, C.3
  • 2
    • 78149308756 scopus 로고    scopus 로고
    • Stent-assisted mechanical recanalization for treatment of acute intracerebral artery occlusions
    • Roth C, Papanagiotou P, Behnke S, et al. Stent-assisted mechanical recanalization for treatment of acute intracerebral artery occlusions. Stroke 2010;41:2559-67
    • (2010) Stroke , vol.41 , pp. 2559-2567
    • Roth, C.1    Papanagiotou, P.2    Behnke, S.3
  • 3
    • 79960014529 scopus 로고    scopus 로고
    • Rescue, combined, and standalone thrombectomy in the management of large vessel occlusion stroke using the Solitaire device: A prospective 50-patient singlecenter study: Timing, safety, and efficacy
    • Costalat V, Machi P, Lobotesis K, et al. Rescue, combined, and standalone thrombectomy in the management of large vessel occlusion stroke using the Solitaire device: a prospective 50-patient singlecenter study: timing, safety, and efficacy. Stroke 2011;42:1929-35
    • (2011) Stroke , vol.42 , pp. 1929-1935
    • Costalat, V.1    MacHi, P.2    Lobotesis, K.3
  • 4
    • 80051999926 scopus 로고    scopus 로고
    • Impact of retrievable stents on acute ischemic stroke treatment
    • Brekenfeld C, Schroth G, Mordasini P, et al. Impact of retrievable stents on acute ischemic stroke treatment. AJNR Am J Neuroradiol 2011;32:1269-73
    • (2011) AJNR Am J Neuroradiol , vol.32 , pp. 1269-1273
    • Brekenfeld, C.1    Schroth, G.2    Mordasini, P.3
  • 5
    • 80053307529 scopus 로고    scopus 로고
    • Mechanical thrombectomy in acute embolic stroke: Preliminary results with the Revive device
    • Rohde S, Haehnel S, Herweh C, et al. Mechanical thrombectomy in acute embolic stroke: preliminary results with the Revive device. Stroke 2011;42:2954-56
    • (2011) Stroke , vol.42 , pp. 2954-2956
    • Rohde, S.1    Haehnel, S.2    Herweh, C.3
  • 6
    • 79951651052 scopus 로고    scopus 로고
    • In vivo evaluation of the first dedicated combined flow-restoration and mechanical thrombectomy device in a swine model of acute vessel occlusion
    • Mordasini P, Frabetti N, Gralla J, et al. In vivo evaluation of the first dedicated combined flow-restoration and mechanical thrombectomy device in a swine model of acute vessel occlusion. AJNR Am J Neuroradiol 2011;32:294-300
    • (2011) AJNR Am J Neuroradiol , vol.32 , pp. 294-300
    • Mordasini, P.1    Frabetti, N.2    Gralla, J.3
  • 7
    • 33747405926 scopus 로고    scopus 로고
    • A dedicated animal model for mechanical thrombectomy in acute stroke
    • Gralla J, Schroth G, Remonda L, et al. A dedicated animal model for mechanical thrombectomy in acute stroke. AJNR Am J Neuroradiol 2006;27:1357-61
    • (2006) AJNR Am J Neuroradiol , vol.27 , pp. 1357-1361
    • Gralla, J.1    Schroth, G.2    Remonda, L.3
  • 8
    • 67449147383 scopus 로고    scopus 로고
    • Percutaneous transluminal angioplasty and stent placement in acute vessel occlusion: Evaluation of new methods for interventional stroke treatment
    • Brekenfeld C, Tinguely P, Schroth G, et al. Percutaneous transluminal angioplasty and stent placement in acute vessel occlusion: evaluation of new methods for interventional stroke treatment. AJNR Am J Neuroradiol 2009;30:1165-72
    • (2009) AJNR Am J Neuroradiol , vol.30 , pp. 1165-1172
    • Brekenfeld, C.1    Tinguely, P.2    Schroth, G.3
  • 9
    • 41149155475 scopus 로고    scopus 로고
    • Mechanical thromboembolectomy for acute ischemic stroke: Comparison of the catch thrombectomy device and the Merci Retriever in vivo
    • Brekenfeld C, Schroth G, El-Koussy M, et al. Mechanical thromboembolectomy for acute ischemic stroke: comparison of the catch thrombectomy device and the Merci Retriever in vivo. Stroke 2008;39:1213-19
    • (2008) Stroke , vol.39 , pp. 1213-1219
    • Brekenfeld, C.1    Schroth, G.2    El-Koussy, M.3
  • 10
    • 77952378555 scopus 로고    scopus 로고
    • In vivo evaluation of the Phenox CRC mechanical thrombectomy device in a swine model of acute vessel occlusion
    • Mordasini P, Hiller M, Brekenfeld C, et al. In vivo evaluation of the Phenox CRC mechanical thrombectomy device in a swine model of acute vessel occlusion. AJNR Am J Neuroradiol 2010;31:972-78
    • (2010) AJNR Am J Neuroradiol , vol.31 , pp. 972-978
    • Mordasini, P.1    Hiller, M.2    Brekenfeld, C.3
  • 11
    • 0042282011 scopus 로고    scopus 로고
    • Trial design and reporting standards for intra-arterial cerebral thrombolysis for acute ischemic stroke
    • Higashida RT, Furlan AJ, Roberts H, et al. Trial design and reporting standards for intra-arterial cerebral thrombolysis for acute ischemic stroke. Stroke 2003;34:e109-137
    • (2003) Stroke , vol.34
    • Higashida, R.T.1    Furlan, A.J.2    Roberts, H.3
  • 12
    • 0033776701 scopus 로고    scopus 로고
    • Vasospasm after subarachnoid hemorrhage: Diagnosis with MR angiography
    • Grandin CB, Cosnard G, Hammer F, et al. Vasospasm after subarachnoid hemorrhage: diagnosis with MR angiography. AJNR Am J Neuroradiol 2000;21:1611-17
    • (2000) AJNR Am J Neuroradiol , vol.21 , pp. 1611-1617
    • Grandin, C.B.1    Cosnard, G.2    Hammer, F.3
  • 13
    • 62449220648 scopus 로고    scopus 로고
    • Stent placement in acute cerebral artery occlusion: Use of a self-expandable intracranial stent for acute stroke treatment
    • Brekenfeld C, Schroth G, Mattle HP, et al. Stent placement in acute cerebral artery occlusion: use of a self-expandable intracranial stent for acute stroke treatment. Stroke 2009;40:847-52
    • (2009) Stroke , vol.40 , pp. 847-852
    • Brekenfeld, C.1    Schroth, G.2    Mattle, H.P.3
  • 14
    • 78649659997 scopus 로고    scopus 로고
    • Solitaire flow-restoration device for treatment of acute ischemic stroke: Safety and recanalization efficacy study in a swine vessel occlusion model
    • Jahan R. Solitaire flow-restoration device for treatment of acute ischemic stroke: safety and recanalization efficacy study in a swine vessel occlusion model. AJNR Am J Neuroradiol 2010;31:1938-43
    • (2010) AJNR Am J Neuroradiol , vol.31 , pp. 1938-1943
    • Jahan, R.1
  • 15
    • 84862983325 scopus 로고    scopus 로고
    • The Trevo device: Preclinical data of a novel stroke thrombectomy device in two different animal models of arterial thrombo-occlusive disease
    • Nogueira RG, Levy EI, Gounis M, et al. The Trevo device: preclinical data of a novel stroke thrombectomy device in two different animal models of arterial thrombo-occlusive disease. J Neurointerv Surg 2012;4:295-300
    • (2012) J Neurointerv Surg , vol.4 , pp. 295-300
    • Nogueira, R.G.1    Levy, E.I.2    Gounis, M.3
  • 16
    • 33845404703 scopus 로고    scopus 로고
    • Mechanical thrombectomy for acute ischemic stroke: Thrombus-device interaction, efficiency, and complications in vivo
    • Gralla J, Schroth G, Remonda L, et al. Mechanical thrombectomy for acute ischemic stroke: thrombus-device interaction, efficiency, and complications in vivo. Stroke 2006;37:3019-24
    • (2006) Stroke , vol.37 , pp. 3019-3024
    • Gralla, J.1    Schroth, G.2    Remonda, L.3
  • 17
    • 39649084031 scopus 로고    scopus 로고
    • Occlusion length is a crucial determinant of efficiency and complication rate in thrombectomy for acute ischemic stroke
    • Gralla J, Burkhardt M, Schroth G, et al. Occlusion length is a crucial determinant of efficiency and complication rate in thrombectomy for acute ischemic stroke. AJNR Am J Neuroradiol 2008;29:247-52
    • (2008) AJNR Am J Neuroradiol , vol.29 , pp. 247-252
    • Gralla, J.1    Burkhardt, M.2    Schroth, G.3
  • 18
    • 33747200163 scopus 로고    scopus 로고
    • Analysis of thrombi retrieved from cerebral arteries of patients with acute ischemic stroke
    • Marder VJ, Chute DJ, Starkman S, et al. Analysis of thrombi retrieved from cerebral arteries of patients with acute ischemic stroke. Stroke 2006;37:2086-93
    • (2006) Stroke , vol.37 , pp. 2086-2093
    • Marder, V.J.1    Chute, D.J.2    Starkman, S.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.