메뉴 건너뛰기




Volumn , Issue , 2012, Pages 6752-6757

Model and transient analysis of Stator Inter-turn Short-circuit Fault in DFIG

Author keywords

Coupled circuit Analysis; DFIG; S function; Stator Inter turn Short circuit

Indexed keywords

COMMON FAULTS; COUPLED-CIRCUIT ANALYSIS; DFIG; DOUBLY-FED INDUCTIONS; FAULT MECHANISM; MATHEMATICS MODEL; MATLAB/SIMULINK MODELS; S-FUNCTION; SHORT-CIRCUIT FAULT; WIND POWER GENERATION SYSTEMS;

EID: 84873537740     PISSN: 19341768     EISSN: 21612927     Source Type: Conference Proceeding    
DOI: None     Document Type: Conference Paper
Times cited : (1)

References (6)
  • 5
    • 79551689148 scopus 로고    scopus 로고
    • Detection of stator short circuit faults in three-phase induction motors using motor current zero crossing instants
    • Abhisek Ukila, Shuo Chenb and Andrea Andennaa. Detection of stator short circuit faults in three-phase induction motors using motor current zero crossing instants. Electric Power Systems Research 2011(81): 1036-1044
    • (2011) Electric Power Systems Research , Issue.81 , pp. 1036-1044
    • Ukila, A.1    Chenb, S.2    Andennaa, A.3
  • 6
    • 70349441141 scopus 로고    scopus 로고
    • L double-fed three-phase induction machine model for simulation of inter-turn short circuit fault
    • A Yazidi H Henao and G A Capolino L Double-fed three-phase induction machine model for simulation of inter-turn short circuit fault Electric Machine and Drives Conference 2009: 571-576.
    • (2009) Electric Machine and Drives Conference , pp. 571-576
    • Yazidi, A.1    Henao, H.2    Capolino, A.G.3