1
-
-
0035018405
-
Clinical use of electronic portal imaging: Report of AAPM Radiation Therapy Committee Task Group 58
-
Herman MG, Balter JM, Jaffray DA, et al. Clinical use of electronic portal imaging: Report of AAPM Radiation Therapy Committee Task Group 58. Med Phys. 2001;28(5):712-37.
-
(2001)
Med Phys
, vol.28
, Issue.5
, pp. 712-737
-
-
Herman, M.G.1
Balter, J.M.2
Jaffray, D.A.3
-
2
-
-
35248819236
-
A study on adaptive IMRT treatment planning using kV cone-beam CT
-
Ding GX, Duggan DM, Coffey CW, et al. A study on adaptive IMRT treatment planning using kV cone-beam CT. Radiother Oncol. 2007;85(1):116-25.
-
(2007)
Radiother Oncol.
, vol.85
, Issue.1
, pp. 116-125
-
-
Ding, G.X.1
Duggan, D.M.2
Coffey, C.W.3
-
3
-
-
37049020907
-
Adaptive radiotherapy for prostate cancer using kilovoltage cone-beam computed tomography: first clinical results
-
Nijkamp J, Pos FJ, Nuver TT, et al. Adaptive radiotherapy for prostate cancer using kilovoltage cone-beam computed tomography: first clinical results. Int J Radiat Oncol Biol Phys. 2008;70(1):75-82.
-
(2008)
Int J Radiat Oncol Biol Phys
, vol.70
, Issue.1
, pp. 75-82
-
-
Nijkamp, J.1
Pos, F.J.2
Nuver, T.T.3
-
4
-
-
79951849484
-
Does the planning dose-volume histogram represent treatment doses in image-guided prostate radiation therapy? Assessment with cone-beam computerised tomography scans
-
Hatton JA, Greer PB, Tang C, et al. Does the planning dose-volume histogram represent treatment doses in image-guided prostate radiation therapy? Assessment with cone-beam computerised tomography scans. Radiother Oncol. 2011;98(2):162-68.
-
(2011)
Radiother Oncol
, vol.98
, Issue.2
, pp. 162-168
-
-
Hatton, J.A.1
Greer, P.B.2
Tang, C.3
-
5
-
-
33847259277
-
Online planning and delivery technique for radiotherapy of spinal metastases using cone-beam CT: image quality and system performance
-
Létourneau D, Wong R, Moseley D, et al. Online planning and delivery technique for radiotherapy of spinal metastases using cone-beam CT: image quality and system performance. Int J Radiat Oncol Biol Phys. 2007;67(4):1229-37.
-
(2007)
Int J Radiat Oncol Biol Phys
, vol.67
, Issue.4
, pp. 1229-1237
-
-
Létourneau, D.1
Wong, R.2
Moseley, D.3
-
6
-
-
74549220500
-
Quantitative evaluation of cone-beam computed tomography in target volume definition for offline image-guided radiation therapy of prostate cancer
-
Wang W, Wu Q, Yan D. Quantitative evaluation of cone-beam computed tomography in target volume definition for offline image-guided radiation therapy of prostate cancer. Radiother Oncol. 2010;94(1):71-75.
-
(2010)
Radiother Oncol
, vol.94
, Issue.1
, pp. 71-75
-
-
Wang, W.1
Wu, Q.2
Yan, D.3
-
7
-
-
70449097654
-
Dose calculation accuracy using cone-beam CT (CBCT) for pelvic adaptive radiotherapy
-
Guang H and Dong H. Dose calculation accuracy using cone-beam CT (CBCT) for pelvic adaptive radiotherapy. Phys Med Biol. 2009;54(20):6239-50.
-
(2009)
Phys Med Biol
, vol.54
, Issue.20
, pp. 6239-6250
-
-
Guang, H.1
Dong, H.2
-
8
-
-
70349776511
-
Cone beam computerized tomography: the effect of calibration of the Hounsfield unit number to electron density on dose calculation accuracy for adaptive radiation therapy
-
Hatton JA, McCurdy B, Greer PB. Cone beam computerized tomography: the effect of calibration of the Hounsfield unit number to electron density on dose calculation accuracy for adaptive radiation therapy. Phys Med Biol. 2009;54(15):N329-N346.
-
(2009)
Phys Med Biol
, vol.54
, Issue.15
-
-
Hatton, J.A.1
McCurdy, B.2
Greer, P.B.3
-
9
-
-
77954744657
-
Kilovoltage cone-beam CT: comparative dose and image quality evaluations in partial and full-angle scan protocols
-
Kim S, Yoo S, Yin FF, Samei E, Yoshizumi T. Kilovoltage cone-beam CT: comparative dose and image quality evaluations in partial and full-angle scan protocols. Med Phys. 2010;37(7):3648-59.
-
(2010)
Med Phys
, vol.37
, Issue.7
, pp. 3648-3659
-
-
Kim, S.1
Yoo, S.2
Yin, F.F.3
Samei, E.4
Yoshizumi, T.5
-
10
-
-
33750568952
-
A quality assurance program for the on-board imager
-
Yoo S, Kim G, Hammoud R, et al. A quality assurance program for the on-board imager. Med Phys. 2006;33(11):4431-47.
-
(2006)
Med Phys
, vol.33
, Issue.11
, pp. 4431-4447
-
-
Yoo, S.1
Kim, G.2
Hammoud, R.3
-
11
-
-
42949173884
-
A quality assurance program for image quality of cone-beam CT guidance in radiation therapy
-
Bissonnette JP, Moseley DJ, Jaffray DA. A quality assurance program for image quality of cone-beam CT guidance in radiation therapy. Med Phys. 2008;35(5):1807-15.
-
(2008)
Med Phys
, vol.35
, Issue.5
, pp. 1807-1815
-
-
Bissonnette, J.P.1
Moseley, D.J.2
Jaffray, D.A.3
-
12
-
-
79954418721
-
Evaluation of radiation dose and image quality for the Varian cone-beam computed tomography system
-
Cheng HC, Wu WC, Liu ES, Kwong DL. Evaluation of radiation dose and image quality for the Varian cone-beam computed tomography system. Int J Rad Onc Biol Phys. 2011;80(1):291-300.
-
(2011)
Int J Rad Onc Biol Phys
, vol.80
, Issue.1
, pp. 291-300
-
-
Cheng, H.C.1
Wu, W.C.2
Liu, E.S.3
Kwong, D.L.4
-
13
-
-
79959551744
-
Bow-tie wobble artefact: effect of source assembly motion on cone-beam CT
-
Zheng D, Ford JC, Lu J, et al. Bow-tie wobble artefact: effect of source assembly motion on cone-beam CT. Med Phys. 2011;38(5):2508-14.
-
(2011)
Med Phys
, vol.38
, Issue.5
, pp. 2508-2514
-
-
Zheng, D.1
Ford, J.C.2
Lu, J.3
-
14
-
-
84975875384
-
The Phantom Laboratory. Catphan 500 and 600 manual. Salem, NY
-
The Phantom Laboratory. Catphan 500 and 600 manual. Salem, NY: The Phantom Laboratory; 2006.
-
(2006)
The Phantom Laboratory
-
-
-
15
-
-
0345308734
-
ImageJ. Bethesda, MA: U. S. National Institutes of Health
-
Available from
-
Rasband WS. ImageJ. Bethesda, MA: U. S. National Institutes of Health; 1997-2009. Available from: http://rsb.info.nih.gov/ij/
-
(1997)
-
-
Rasband, W.S.1
-
17
-
-
85020803012
-
Computed tomography. principles, design, artifacts, and recent advances, 2nd edition
-
Hsieh J. Computed tomography. principles, design, artifacts, and recent advances, 2nd edition. Hoboken, NJ: SPIE and Wiley-Interscience; 2009.
-
(2009)
Hoboken, NJ: SPIE and Wiley-Interscience
-
-
Hsieh, J.1
-
18
-
-
0021858245
-
A simplified approach for modulation transfer function determinations in computed tomography
-
Nickoloff EL and Riley R. A simplified approach for modulation transfer function determinations in computed tomography. Med Phys. 1985;12(4):437-42.
-
(1985)
Med Phys
, vol.12
, Issue.4
, pp. 437-442
-
-
Nickoloff, E.L.1
Riley, R.2
-
19
-
-
0023870198
-
Measurement of the PSF for a CT scanner: appropriate wire diameter and pixel size
-
Nickoloff EL. Measurement of the PSF for a CT scanner: appropriate wire diameter and pixel size. Phys Med Biol. 1988;33(1):149-55.
-
(1988)
Phys Med Biol
, vol.33
, Issue.1
, pp. 149-155
-
-
Nickoloff, E.L.1
-
20
-
-
0019913387
-
A practical method to measure the MTF of CT scanners
-
Droegue RT and Morin RL. A practical method to measure the MTF of CT scanners. Med Phys. 1982;9(5):758-60.
-
(1982)
Med Phys
, vol.9
, Issue.5
, pp. 758-760
-
-
Droegue, R.T.1
Morin, R.L.2
-
21
-
-
0000188292
-
The specification of imaging properties by response to a sine wave input
-
Coltman JW. The specification of imaging properties by response to a sine wave input. J Opt Soc Am. 1954;44(6):468-71.
-
(1954)
J Opt Soc Am
, vol.44
, Issue.6
, pp. 468-471
-
-
Coltman, J.W.1
-
22
-
-
70349310249
-
Image quality and stability of image-guided radiotherapy (IGRT) devices: a comparative study
-
Stock M, Pasler M, Birkfellner W, Homolka P, Poetter R, Georg D. Image quality and stability of image-guided radiotherapy (IGRT) devices: a comparative study. Radiother Oncol. 2009;93(1):1-7.
-
(2009)
Radiother Oncol
, vol.93
, Issue.1
, pp. 1-7
-
-
Stock, M.1
Pasler, M.2
Birkfellner, W.3
Homolka, P.4
Poetter, R.5
Georg, D.6
-
23
-
-
0033088416
-
The rose model revisited
-
Burgess AE. The rose model revisited. J Opt Soc Am A. 1999;16(3):633-46.
-
(1999)
J Opt Soc Am A
, vol.16
, Issue.3
, pp. 633-646
-
-
Burgess, A.E.1
-
24
-
-
0000356133
-
Signal-to-noise optimization of medical imaging systems
-
Cunningham IA and Shaw R. Signal-to-noise optimization of medical imaging systems. J Opt Soc Am A. 1999;16(3):621-32
-
(1999)
J Opt Soc Am A
, vol.16
, Issue.3
, pp. 621-623
-
-
Cunningham, I.A.1
Shaw, R.2
-
25
-
-
0842335784
-
A statistical Method of defining Low Contrast Detectability
-
Chao EH, Toth TL, Bromberg NB, Williams EC, Fox SH, Carleton DA. A statistical Method of defining Low Contrast Detectability. Radiology. 2000;()217:162.
-
(2000)
Radiology
, vol.217
, pp. 162
-
-
Chao, E.H.1
Toth, T.L.2
Bromberg, N.B.3
Williams, E.C.4
Fox, S.H.5
Carleton, D.A.6
|