Volumn 84, Issue 2, 2013, Pages 227-232

The PAWPER tape: A new concept tape-based device that increases the accuracy of weight estimation in children through the inclusion of a modifier based on body habitus

Author keywords

Broselow tape; Children; PAWPER tape; Resuscitation; Resuscitation aid; Weight estimation

Indexed keywords

ARTICLE; BODY MASS; BODY WEIGHT; BROSELOW TAPE; CHILD; EMERGENCY WARD; FEMALE; HUMAN; INFANT; MAJOR CLINICAL STUDY; MALE; MEASUREMENT; MEASUREMENT ACCURACY; PAWPER TAPE; PRESCHOOL CHILD; PRIORITY JOURNAL; PROSPECTIVE STUDY; SCHOOL CHILD; SOUTH AFRICA;

EID: 84873465244     PISSN: 03009572     EISSN: 18731570     Source Type: Journal    
DOI: 10.1016/j.resuscitation.2012.05.028     Document Type: Article
Times cited : (63)

References (26)
  • 1
    • 0036298217 scopus 로고    scopus 로고
    • Are methods used to estimate weight in children accurate?
    • Black K., Barnett P., Wolfe R., Young S. Are methods used to estimate weight in children accurate?. Emerg Med 2002, 14:160-165.
    • (2002) Emerg Med , vol.14 , pp. 160-165
    • Black, K.1    Barnett, P.2    Wolfe, R.3    Young, S.4
  • 2
    • 0033044109 scopus 로고    scopus 로고
    • Parental estimates of their child's weight: accurate for resuscitation drug doses
    • Goldman R.D., Buskin S., Augarten A. Parental estimates of their child's weight: accurate for resuscitation drug doses. Pediatr Emerg Care 1999, 15:19-21.
    • (1999) Pediatr Emerg Care , vol.15 , pp. 19-21
    • Goldman, R.D.1    Buskin, S.2    Augarten, A.3
  • 3
    • 34247857343 scopus 로고    scopus 로고
    • Weight estimation in resuscitation: is the current formula still valid?
    • Luscombe M., Owens B. Weight estimation in resuscitation: is the current formula still valid?. Arch Dis Child 2007, 92:412-415.
    • (2007) Arch Dis Child , vol.92 , pp. 412-415
    • Luscombe, M.1    Owens, B.2
  • 4
    • 44049099512 scopus 로고    scopus 로고
    • Internationalizing the Broselow tape: how reliable is weight estimation in Indian children
    • Ramarajan N., Krishnamoorthi R., Strehlow M., Quinn J., Mahadevan S.V. Internationalizing the Broselow tape: how reliable is weight estimation in Indian children. Acad Emerg Med 2008, 15:431-436.
    • (2008) Acad Emerg Med , vol.15 , pp. 431-436
    • Ramarajan, N.1    Krishnamoorthi, R.2    Strehlow, M.3    Quinn, J.4    Mahadevan, S.V.5
  • 5
    • 22644442818 scopus 로고    scopus 로고
    • Emergency weight estimation in Pacific Island and Maori children who are large-for-age
    • Theron L., Adams A., Jansen K., Robinson E. Emergency weight estimation in Pacific Island and Maori children who are large-for-age. Emerg Med Australas 2005, 17:238-243.
    • (2005) Emerg Med Australas , vol.17 , pp. 238-243
    • Theron, L.1    Adams, A.2    Jansen, K.3    Robinson, E.4
  • 6
    • 34247167919 scopus 로고    scopus 로고
    • Failed validation of the Argall weight formula for estimating children's weight in an Australian emergency department
    • Nguyen K., Krieser D., Kerr D., et al. Failed validation of the Argall weight formula for estimating children's weight in an Australian emergency department. Acad Emerg Med 2007, 14:486-488.
    • (2007) Acad Emerg Med , vol.14 , pp. 486-488
    • Nguyen, K.1    Krieser, D.2    Kerr, D.3
  • 7
    • 77954692739 scopus 로고    scopus 로고
    • Can undergraduate paramedic and nursing students accurately estimate patient age and weight?
    • Williams B., Boyle M., O'Meara P. Can undergraduate paramedic and nursing students accurately estimate patient age and weight?. Prehosp Disaster Med 2010, 25:171-177.
    • (2010) Prehosp Disaster Med , vol.25 , pp. 171-177
    • Williams, B.1    Boyle, M.2    O'Meara, P.3
  • 8
    • 79958049776 scopus 로고    scopus 로고
    • Comparison of Broselow tape measurements versus physician estimations of pediatric weights
    • Rosenberg M., Greenberger S., Rawal A., Latimer-Pierson J., Thundiyil J. Comparison of Broselow tape measurements versus physician estimations of pediatric weights. Am J Emerg Med 2011, 29:482-488.
    • (2011) Am J Emerg Med , vol.29 , pp. 482-488
    • Rosenberg, M.1    Greenberger, S.2    Rawal, A.3    Latimer-Pierson, J.4    Thundiyil, J.5
  • 10
    • 84856005193 scopus 로고    scopus 로고
    • Accuracy of the Broselow tape in estimating the weight of first nations children
    • Bourdeau S., Copeland J., Milne W.K. Accuracy of the Broselow tape in estimating the weight of first nations children. Can J Rural Med 2011, 16:121-125.
    • (2011) Can J Rural Med , vol.16 , pp. 121-125
    • Bourdeau, S.1    Copeland, J.2    Milne, W.K.3
  • 11
    • 79960006727 scopus 로고    scopus 로고
    • Is the Broselow tape a reliable indicator for use in all pediatric trauma patients?: A look at a rural trauma center
    • Knight J.C., Nazim M., Riggs D., et al. Is the Broselow tape a reliable indicator for use in all pediatric trauma patients?: A look at a rural trauma center. Pediatr Emerg Care 2011, 27:479-482.
    • (2011) Pediatr Emerg Care , vol.27 , pp. 479-482
    • Knight, J.C.1    Nazim, M.2    Riggs, D.3
  • 12
    • 33748918601 scopus 로고    scopus 로고
    • Use of the Broselow tape may result in the underresuscitation of children
    • Nieman C.T., Manacci C.F., Super D.M., Mancuso C., Fallon W.F. Use of the Broselow tape may result in the underresuscitation of children. Acad Emerg Med 2006, 13:1011-1019.
    • (2006) Acad Emerg Med , vol.13 , pp. 1011-1019
    • Nieman, C.T.1    Manacci, C.F.2    Super, D.M.3    Mancuso, C.4    Fallon, W.F.5
  • 13
    • 35848935211 scopus 로고    scopus 로고
    • Parental weight estimation of their child's weight is more accurate than other weight estimation methods for determining children's weight in an emergency department?
    • Krieser D., Nguyen K., Kerr D., Jolley D., Clooney M., Kelly A.-M. Parental weight estimation of their child's weight is more accurate than other weight estimation methods for determining children's weight in an emergency department?. Emerg Med J 2007, 24:756-759.
    • (2007) Emerg Med J , vol.24 , pp. 756-759
    • Krieser, D.1    Nguyen, K.2    Kerr, D.3    Jolley, D.4    Clooney, M.5    Kelly, A.-M.6
  • 15
    • 68349110868 scopus 로고    scopus 로고
    • Improving length-based weight estimates by adding a body habitus (obesity) icon
    • Yamamoto L.G., Inaba A.S., Young L.L., Anderson K.M. Improving length-based weight estimates by adding a body habitus (obesity) icon. Am J Emerg Med 2009, 27:810-815.
    • (2009) Am J Emerg Med , vol.27 , pp. 810-815
    • Yamamoto, L.G.1    Inaba, A.S.2    Young, L.L.3    Anderson, K.M.4
  • 16
    • 39549097083 scopus 로고    scopus 로고
    • Why Bland-Altman plots should use X, not (Y+X)/2 when X is a reference method
    • Krouwer J.S. Why Bland-Altman plots should use X, not (Y+X)/2 when X is a reference method. Stat Med 2008, 27:778-780.
    • (2008) Stat Med , vol.27 , pp. 778-780
    • Krouwer, J.S.1
  • 17
    • 66249140998 scopus 로고    scopus 로고
    • Evaluation of the accuracy of different methods used to estimate weights in the pediatric population
    • So T.Y., Farrington E., Absher R.K. Evaluation of the accuracy of different methods used to estimate weights in the pediatric population. Pediatrics 2009, 123:e1045-e1051.
    • (2009) Pediatrics , vol.123
    • So, T.Y.1    Farrington, E.2    Absher, R.K.3
  • 18
    • 80052971125 scopus 로고    scopus 로고
    • Validation of weight estimation by age and length based methods in the Western Cape, South Africa population
    • Geduld H., Hodkinson P.W., Wallis L.A. Validation of weight estimation by age and length based methods in the Western Cape, South Africa population. Emerg Med J 2011, 28:856-860.
    • (2011) Emerg Med J , vol.28 , pp. 856-860
    • Geduld, H.1    Hodkinson, P.W.2    Wallis, L.A.3
  • 19
    • 0024688060 scopus 로고
    • Body habitus+height=accurate weight estimate
    • Losek J.D., Garland J., Nelson D.B. Body habitus+height=accurate weight estimate. Ann Emerg Med 1989, 18:709.
    • (1989) Ann Emerg Med , vol.18 , pp. 709
    • Losek, J.D.1    Garland, J.2    Nelson, D.B.3
  • 20
    • 33748918601 scopus 로고    scopus 로고
    • Use of the Broselow tape may result in the underresuscitation of children
    • Nieman C.T., Manacci C.F., Super D.M., Mancuso C., Fallon W.F. Use of the Broselow tape may result in the underresuscitation of children. Acad Emerg Med 2006, 13:1011-1019.
    • (2006) Acad Emerg Med , vol.13 , pp. 1011-1019
    • Nieman, C.T.1    Manacci, C.F.2    Super, D.M.3    Mancuso, C.4    Fallon, W.F.5
  • 21
    • 36248997555 scopus 로고    scopus 로고
    • The dilemma of paediatric drug dosing and equipment sizing in the era of patient safety
    • Dieckmann R.A. The dilemma of paediatric drug dosing and equipment sizing in the era of patient safety. Emerg Med Australas 2007, 19:490-493.
    • (2007) Emerg Med Australas , vol.19 , pp. 490-493
    • Dieckmann, R.A.1
  • 22
    • 36249024080 scopus 로고    scopus 로고
    • Best Guess method for age-based weight estimation in paediatric emergencies validation and comparison with current methods
    • Thompson M.T., Reading M.J., Acworth J.P. Best Guess method for age-based weight estimation in paediatric emergencies validation and comparison with current methods. Emerg Med Australas 2007, 19:535-542.
    • (2007) Emerg Med Australas , vol.19 , pp. 535-542
    • Thompson, M.T.1    Reading, M.J.2    Acworth, J.P.3
  • 23
    • 44049083023 scopus 로고    scopus 로고
    • The sophistication of simplicity...optimising emergency dosing
    • Luten R., Zaritsky A. The sophistication of simplicity...optimising emergency dosing. Acad Emerg Med 2008, 15:461-465.
    • (2008) Acad Emerg Med , vol.15 , pp. 461-465
    • Luten, R.1    Zaritsky, A.2
  • 24
    • 34247211696 scopus 로고    scopus 로고
    • Accuracy of weight estimation methods for children
    • DuBois D., Baldwin S., King W.D. Accuracy of weight estimation methods for children. Pediatr Emerg Care 2007, 23:227-230.
    • (2007) Pediatr Emerg Care , vol.23 , pp. 227-230
    • DuBois, D.1    Baldwin, S.2    King, W.D.3
  • 25
    • 0036337329 scopus 로고    scopus 로고
    • Managing the unique size-related issues of paediatric resuscitation: reducing cognitive load with resuscitation aids
    • Luten R., Wears R.L., Broselow J., Croskerry P., Joseph M.M., Frush K. Managing the unique size-related issues of paediatric resuscitation: reducing cognitive load with resuscitation aids. Acad Emerg Med 2002, 9:840-847.
    • (2002) Acad Emerg Med , vol.9 , pp. 840-847
    • Luten, R.1    Wears, R.L.2    Broselow, J.3    Croskerry, P.4    Joseph, M.M.5    Frush, K.6
  • 26
    • 84856009336 scopus 로고    scopus 로고
    • Root causes of errors in a simulated prehospital pediatric emergency
    • Lammers R., Byrwa M., Fales W. Root causes of errors in a simulated prehospital pediatric emergency. Acad Emerg Med 2012, 19:37-47.
    • (2012) Acad Emerg Med , vol.19 , pp. 37-47
    • Lammers, R.1    Byrwa, M.2    Fales, W.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.