메뉴 건너뛰기




Volumn 178, Issue , 2013, Pages 606-614

Highly selective and stable microdisc biosensors for l-glutamate monitoring

Author keywords

Biosensor; Glutamate; Nafion; o Phenylenediamine; Selectivity; Stability

Indexed keywords

AMPEROMETRIC BIOSENSORS; ASCORBIC ACIDS; CALIBRATION CURVES; CONTINUOUS MONITORING; GLUTAMATE; GLUTAMATE OXIDASE; GOOD STABILITY; HIGH SENSITIVITY; KEY FACTORS; L-GLUTAMATE; LOW DETECTION LIMIT; MICRODISCS; NAFION; NEURODEGENERATIVE; O-PHENYLENEDIAMINE; PHOSPHATIDYLETHANOLAMINE; PSYCHIATRIC DISEASE; STABILITY MEASUREMENTS; SYNAPTIC TRANSMISSION; TEMPORAL STABILITY; TRAUMATIC BRAIN INJURIES;

EID: 84873385828     PISSN: 09254005     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.snb.2012.12.077     Document Type: Article
Times cited : (26)

References (52)
  • 1
    • 0021330769 scopus 로고
    • Glutamate: A neurotransmitter in mammalian brain
    • F. Fonnum Glutamate: a neurotransmitter in mammalian brain Journal of Neurochemistry 42 1984 1 11
    • (1984) Journal of Neurochemistry , vol.42 , pp. 1-11
    • Fonnum, F.1
  • 2
    • 0032704738 scopus 로고    scopus 로고
    • Glutamate: An excitatory neurotransmitter in the mammalian CNS
    • R.J. Weinberg Glutamate: an excitatory neurotransmitter in the mammalian CNS Brain Research Bulletin 50 1999 353 354
    • (1999) Brain Research Bulletin , vol.50 , pp. 353-354
    • Weinberg, R.J.1
  • 3
    • 0034019630 scopus 로고    scopus 로고
    • Compartmentation of brain glutamate metabolism in neurons and glia
    • Y. Daikhin, and M. Yudkoff Compartmentation of brain glutamate metabolism in neurons and glia Journal of Nutrition 130 2000 1026-
    • (2000) Journal of Nutrition , vol.130 , pp. 1026
    • Daikhin, Y.1    Yudkoff, M.2
  • 5
    • 84891435535 scopus 로고    scopus 로고
    • Glutamatergic pathways their relevance for psychiatric diseases
    • W.J. Schmidt, M.E.A. Reith, Humana Press NJ, USA
    • Y. Smith Glutamatergic pathways their relevance for psychiatric diseases W.J. Schmidt, M.E.A. Reith, Dopamine and Glutamate in Psychiatric Disorders 2005 Humana Press NJ, USA 63 78
    • (2005) Dopamine and Glutamate in Psychiatric Disorders , pp. 63-78
    • Smith, Y.1
  • 6
    • 0000004020 scopus 로고    scopus 로고
    • Glutamate and aspartate
    • G.J. Siegel, B.W. Agranoff, R.W. Albers, S.K. Fisher, M.D. Uhler, Lippincott Williams & Wilkins Philadelphia
    • R. Dingledine, and C.L. McBain Glutamate and aspartate G.J. Siegel, B.W. Agranoff, R.W. Albers, S.K. Fisher, M.D. Uhler, Basic Neurochemistry: Molecular, Cellular and Medical Aspects 1999 Lippincott Williams & Wilkins Philadelphia 315 334
    • (1999) Basic Neurochemistry: Molecular, Cellular and Medical Aspects , pp. 315-334
    • Dingledine, R.1    McBain, C.L.2
  • 8
    • 33645241776 scopus 로고    scopus 로고
    • A biosensor based on co-immobilized l-glutamate oxidase and l-glutamate dehydrogenase for analysis of monosodium glutamate in food
    • A.K. Basu, P. Chattopadhyay, U. Roychudhuri, and R. Chakraborty A biosensor based on co-immobilized l-glutamate oxidase and l-glutamate dehydrogenase for analysis of monosodium glutamate in food Biosensors and Bioelectronics 21 2006 1968 1972
    • (2006) Biosensors and Bioelectronics , vol.21 , pp. 1968-1972
    • Basu, A.K.1    Chattopadhyay, P.2    Roychudhuri, U.3    Chakraborty, R.4
  • 9
    • 0028190331 scopus 로고
    • Neuron-glial interaction during injury and edema of the CNS
    • O.S. Kempski, and C. Volk Neuron-glial interaction during injury and edema of the CNS Acta Neurochirurgica 60 Suppl. 1994 7 11
    • (1994) Acta Neurochirurgica , vol.60 , Issue.SUPPL. , pp. 7-11
    • Kempski, O.S.1    Volk, C.2
  • 11
    • 0041878432 scopus 로고    scopus 로고
    • Ceramic-based multisite microelectrode arrays for in vivo electrochemical recordings of glutamate and other neurochemicals
    • G.A. Gerhardt, and J.J. Burmeister Ceramic-based multisite microelectrode arrays for in vivo electrochemical recordings of glutamate and other neurochemicals TrAC, Trends in Analytical Chemistry 22 2003 498 502
    • (2003) TrAC, Trends in Analytical Chemistry , vol.22 , pp. 498-502
    • Gerhardt, G.A.1    Burmeister, J.J.2
  • 12
    • 0028472185 scopus 로고
    • Online measurement of brain glutamate with an enzyme/polymer-coated tubular electrode
    • M.G. Boutelle, M.O.M. Berners, and M. Fillenz Online measurement of brain glutamate with an enzyme/polymer-coated tubular electrode Analytical Chemistry 66 1994 2017 2021
    • (1994) Analytical Chemistry , vol.66 , pp. 2017-2021
    • Boutelle, M.G.1    Berners, M.O.M.2    Fillenz, M.3
  • 13
    • 14644416517 scopus 로고    scopus 로고
    • Glutamate detection from nerve cells using a planar electrodes array integrated in a microtiter plate
    • J. Castillo, A. Blochl, S. Dennison, W. Schuhmann, and E. Csoregi Glutamate detection from nerve cells using a planar electrodes array integrated in a microtiter plate Biosensors and Bioelectronics 20 2005 2116
    • (2005) Biosensors and Bioelectronics , vol.20 , pp. 2116
    • Castillo, J.1    Blochl, A.2    Dennison, S.3    Schuhmann, W.4    Csoregi, E.5
  • 14
    • 0031440427 scopus 로고    scopus 로고
    • Amperometric glutamate biosensor based on poly(o-phenylenediamine) film electrogenerated onto modified carbon paste electrodes
    • S.L. Alvarez-Crespo, M.J. Lobo-Castanon, A.J. Miranda-Ordieres, and P. Tunon-Blanco Amperometric glutamate biosensor based on poly(o-phenylenediamine) film electrogenerated onto modified carbon paste electrodes Biosensors and Bioelectronics 12 1997 739 747
    • (1997) Biosensors and Bioelectronics , vol.12 , pp. 739-747
    • Alvarez-Crespo, S.L.1    Lobo-Castanon, M.J.2    Miranda-Ordieres, A.J.3    Tunon-Blanco, P.4
  • 15
    • 0030727757 scopus 로고    scopus 로고
    • Biosensor for neurotransmitter l-glutamic acid designed for efficient use of l-glutamate oxidase and effective rejection of interference
    • M.R. Ryan, J.P. Lowry, and R.D. O'Neill Biosensor for neurotransmitter l-glutamic acid designed for efficient use of l-glutamate oxidase and effective rejection of interference Analyst 122 1997 1419 1424
    • (1997) Analyst , vol.122 , pp. 1419-1424
    • Ryan, M.R.1    Lowry, J.P.2    O'Neill, R.D.3
  • 17
    • 0028472185 scopus 로고
    • On-line measurement of brain glutamate with an enzyme/polymer-coated tubular electrode
    • M.O. Berners, M.G. Boutelle, and M. Fillenz On-line measurement of brain glutamate with an enzyme/polymer-coated tubular electrode Analytical Chemistry 66 1994 2017 2021
    • (1994) Analytical Chemistry , vol.66 , pp. 2017-2021
    • Berners, M.O.1    Boutelle, M.G.2    Fillenz, M.3
  • 18
    • 33749509396 scopus 로고    scopus 로고
    • Receptors and enzymes for medical sensing of l-glutamate
    • A. Hirano, and M. Sugawara Receptors and enzymes for medical sensing of l-glutamate Mini Reviews in Medicinal Chemistry 6 2006 1091 1100
    • (2006) Mini Reviews in Medicinal Chemistry , vol.6 , pp. 1091-1100
    • Hirano, A.1    Sugawara, M.2
  • 19
    • 6344285504 scopus 로고    scopus 로고
    • The selectivity of electrosynthesised polymer membranes depends on the electrode dimensions: Implications for biosensor applications
    • C.P. McMahon, S.J. Killoran, S.M. Kirwan, and R.D. O'Neill The selectivity of electrosynthesised polymer membranes depends on the electrode dimensions: implications for biosensor applications Chemical Communications 18 2004 2128 2130
    • (2004) Chemical Communications , vol.18 , pp. 2128-2130
    • McMahon, C.P.1    Killoran, S.J.2    Kirwan, S.M.3    O'Neill, R.D.4
  • 20
    • 0038121453 scopus 로고    scopus 로고
    • Microelectrochemical sensors for in vivo brain analysis: An investigation of procedures for modifying Pt electrodes using Nafion
    • F.O. Brown, and J.P. Lowry Microelectrochemical sensors for in vivo brain analysis: an investigation of procedures for modifying Pt electrodes using Nafion Analyst 128 2003 700 705
    • (2003) Analyst , vol.128 , pp. 700-705
    • Brown, F.O.1    Lowry, J.P.2
  • 21
    • 0041878432 scopus 로고    scopus 로고
    • Ceramic-based multisite microelectrode arrays for in vivo electrochemical recordings of glutamate and other neurochemicals
    • J.J. Burmeister, and G.A. Gerhardt Ceramic-based multisite microelectrode arrays for in vivo electrochemical recordings of glutamate and other neurochemicals TrAC, Trends in Analytical Chemistry 22 2003 498 502
    • (2003) TrAC, Trends in Analytical Chemistry , vol.22 , pp. 498-502
    • Burmeister, J.J.1    Gerhardt, G.A.2
  • 22
    • 30844474185 scopus 로고    scopus 로고
    • The efficiency of immobilised glutamate oxidase decreases with surface enzyme loading: An electrostatic effect, and reversal by a polycation significantly enhances biosensor sensitivity
    • C.P. McMahon, G. Rocchitta, P.A. Serra, S.M. Kirwan, J.P. Lowry, and R.D. O'Neill The efficiency of immobilised glutamate oxidase decreases with surface enzyme loading: an electrostatic effect, and reversal by a polycation significantly enhances biosensor sensitivity Analyst 131 2006 68 72
    • (2006) Analyst , vol.131 , pp. 68-72
    • McMahon, C.P.1    Rocchitta, G.2    Serra, P.A.3    Kirwan, S.M.4    Lowry, J.P.5    O'Neill, R.D.6
  • 23
    • 0029972048 scopus 로고    scopus 로고
    • Strategies for decreasing ascorbate interference at glucose oxidase-modified poly(o-phenylenediamine)-coated electrodes
    • K. McAteer, and R.D. O'Neill Strategies for decreasing ascorbate interference at glucose oxidase-modified poly(o-phenylenediamine)-coated electrodes Analyst 121 1996 773 777
    • (1996) Analyst , vol.121 , pp. 773-777
    • McAteer, K.1    O'Neill, R.D.2
  • 25
    • 0031955349 scopus 로고    scopus 로고
    • Monitoring brain chemistry in vivo: Voltammetric techniques, sensors and behavioral applications
    • R.D. O'Neill, J.P. Lowry, and M. Mas Monitoring brain chemistry in vivo: voltammetric techniques, sensors and behavioral applications Critical Reviews in Neurobiology 12 1998 69 127
    • (1998) Critical Reviews in Neurobiology , vol.12 , pp. 69-127
    • O'Neill, R.D.1    Lowry, J.P.2    Mas, M.3
  • 26
    • 0025671780 scopus 로고
    • Glucose fast-response amperometric sensor based on glucose oxidase immobilized in an electropolymerized poly(o-phenylenediamine) film
    • C. Malitesta, F. Palmisano, L. Torsi, and P.G. Zambonin Glucose fast-response amperometric sensor based on glucose oxidase immobilized in an electropolymerized poly(o-phenylenediamine) film Analytical Chemistry 62 1990 2735 2740
    • (1990) Analytical Chemistry , vol.62 , pp. 2735-2740
    • Malitesta, C.1    Palmisano, F.2    Torsi, L.3    Zambonin, P.G.4
  • 27
    • 84987467040 scopus 로고
    • Partial characterization in vitro of glucose oxidase-modified poly(phenylenediamine)-coated electrodes for neurochemical analysis in vivo
    • J.P. Lowry, and R.D. O'Neill Partial characterization in vitro of glucose oxidase-modified poly(phenylenediamine)-coated electrodes for neurochemical analysis in vivo Electroanalysis 6 1994 369 379
    • (1994) Electroanalysis , vol.6 , pp. 369-379
    • Lowry, J.P.1    O'Neill, R.D.2
  • 28
    • 0001296947 scopus 로고
    • Ultrathin porous carbon films as amperometric transducers for biocatalytic sensors
    • J. Wang, Q. Chen, C.L. Renschler, and C. White Ultrathin porous carbon films as amperometric transducers for biocatalytic sensors Analytical Chemistry 66 1994 1988 1992
    • (1994) Analytical Chemistry , vol.66 , pp. 1988-1992
    • Wang, J.1    Chen, Q.2    Renschler, C.L.3    White, C.4
  • 29
    • 70549086062 scopus 로고    scopus 로고
    • Effects of polymerization potential on the permselectivity of poly(o-phenylenediamine) coatings deposited on Pt-Ir electrodes for biosensor applications
    • S.A. Rothwell, C.P. McMahon, and R.D. O'Neill Effects of polymerization potential on the permselectivity of poly(o-phenylenediamine) coatings deposited on Pt-Ir electrodes for biosensor applications Electrochimica Acta 55 2010 1051 1060
    • (2010) Electrochimica Acta , vol.55 , pp. 1051-1060
    • Rothwell, S.A.1    McMahon, C.P.2    O'Neill, R.D.3
  • 30
    • 48049083545 scopus 로고    scopus 로고
    • Characterization of permselective coatings electrosynthesized on Pt-Ir from the three phenylenediamine isomers for biosensor applications
    • S.J. Killoran, and R.D. O'Neill Characterization of permselective coatings electrosynthesized on Pt-Ir from the three phenylenediamine isomers for biosensor applications Electrochimica Acta 53 2008 7303 7312
    • (2008) Electrochimica Acta , vol.53 , pp. 7303-7312
    • Killoran, S.J.1    O'Neill, R.D.2
  • 31
    • 0031272092 scopus 로고    scopus 로고
    • Approaches to the integration of electrochemistry and biotechnology. 1. Enzyme-modified reticulated vitreous carbon electrodes
    • P.N. Bartlett, D. Pletcher, and J. Zeng Approaches to the integration of electrochemistry and biotechnology. 1. Enzyme-modified reticulated vitreous carbon electrodes Journal of the Electrochemical Society 144 1997 3705 3710
    • (1997) Journal of the Electrochemical Society , vol.144 , pp. 3705-3710
    • Bartlett, P.N.1    Pletcher, D.2    Zeng, J.3
  • 32
    • 40949140177 scopus 로고    scopus 로고
    • Multi-walled carbon nanotubes with poly(methylene blue) composite film for the enhancement and separation of electroanalytical responses of catecholamine and ascorbic acid
    • U. Yogeswaran, and S.M. Chen Multi-walled carbon nanotubes with poly(methylene blue) composite film for the enhancement and separation of electroanalytical responses of catecholamine and ascorbic acid Sensors and Actuators B: Chemical 130 2008 739 749
    • (2008) Sensors and Actuators B: Chemical , vol.130 , pp. 739-749
    • Yogeswaran, U.1    Chen, S.M.2
  • 33
    • 60649087831 scopus 로고    scopus 로고
    • Selective detection of dopamine using a combined permselective film of electropolymerized (poly-tyramine and poly-pyrrole-1-propionic acid) on a boron-doped diamond electrode
    • F.J. Shang, Y.L. Liu, S. Hrapovic, J.D. Glennon, and J.H.T. Luong Selective detection of dopamine using a combined permselective film of electropolymerized (poly-tyramine and poly-pyrrole-1-propionic acid) on a boron-doped diamond electrode Analyst 134 2009 519 527
    • (2009) Analyst , vol.134 , pp. 519-527
    • Shang, F.J.1    Liu, Y.L.2    Hrapovic, S.3    Glennon, J.D.4    Luong, J.H.T.5
  • 34
    • 0000707017 scopus 로고
    • Electropolymerized 1,2-diaminobenzene as a means to prevent interferences and fouling and to stabilize immobilized enzyme in electrochemical biosensors
    • S.V. Sasso, R.J. Pierce, R. Walla, and A.M. Yacynych Electropolymerized 1,2-diaminobenzene as a means to prevent interferences and fouling and to stabilize immobilized enzyme in electrochemical biosensors Analytical Chemistry 62 1990 1111 1117
    • (1990) Analytical Chemistry , vol.62 , pp. 1111-1117
    • Sasso, S.V.1    Pierce, R.J.2    Walla, R.3    Yacynych, A.M.4
  • 35
    • 0001982269 scopus 로고
    • Structure-property relationships in poly(o-phenylenediamine) derivatives
    • M.-A. Goyette, and M. Leclerc Structure-property relationships in poly(o-phenylenediamine) derivatives Journal of Electroanalytical Chemistry 382 1995 17 23
    • (1995) Journal of Electroanalytical Chemistry , vol.382 , pp. 17-23
    • Goyette, M.-A.1    Leclerc, M.2
  • 36
    • 0037136460 scopus 로고    scopus 로고
    • Poly(1,2-diaminobenzene) and poly(1,3-diaminobenzene). Synthesis, characterization, and properties
    • C.O. Sánchez, and B.L. Rivas Poly(1,2-diaminobenzene) and poly(1,3-diaminobenzene). Synthesis, characterization, and properties Journal of Applied Polymer Science 85 2002 2564 2572
    • (2002) Journal of Applied Polymer Science , vol.85 , pp. 2564-2572
    • Sánchez, C.O.1    Rivas, B.L.2
  • 37
    • 4944240291 scopus 로고    scopus 로고
    • Analysis of the impedance spectra of Pt/poly(o-phenylenediamine) electrodes-hydrogen adsorption and the brush model of the polymer films
    • G.G. Lang, M. Ujvari, and G. Inzelt Analysis of the impedance spectra of Pt/poly(o-phenylenediamine) electrodes-hydrogen adsorption and the brush model of the polymer films Journal of Electroanalytical Chemistry 572 2004 283 297
    • (2004) Journal of Electroanalytical Chemistry , vol.572 , pp. 283-297
    • Lang, G.G.1    Ujvari, M.2    Inzelt, G.3
  • 38
    • 1042286383 scopus 로고    scopus 로고
    • Estimating the thickness of hydrated ultrathin poly(o-phenylenediamine) film by atomic force microscopy
    • C.-C. Wu, and H.-C. Chang Estimating the thickness of hydrated ultrathin poly(o-phenylenediamine) film by atomic force microscopy Analytica Chimica Acta 505 2004 239 246
    • (2004) Analytica Chimica Acta , vol.505 , pp. 239-246
    • Wu, C.-C.1    Chang, H.-C.2
  • 40
    • 84987564714 scopus 로고
    • Permeation of solutes through an electropolymerized ultrathin poly-o-phenylenediamine film used as an enzyme-entrapping membrane
    • D. Centonze, C. Malitesta, F. Palmisano, and P.G. Zambonin Permeation of solutes through an electropolymerized ultrathin poly-o-phenylenediamine film used as an enzyme-entrapping membrane Electroanalysis 6 1994 423 429
    • (1994) Electroanalysis , vol.6 , pp. 423-429
    • Centonze, D.1    Malitesta, C.2    Palmisano, F.3    Zambonin, P.G.4
  • 42
    • 30744432400 scopus 로고    scopus 로고
    • The brush model of the polymer films - Analysis of the impedance spectra of Au, Pt poly(o-phenylenediamine) electrodes
    • G.G. Lang, M. Ujvari, T.A. Rokob, and G. Inzelt The brush model of the polymer films - analysis of the impedance spectra of Au, Pt poly(o- phenylenediamine) electrodes Electrochimica Acta 51 2006 1680 1694
    • (2006) Electrochimica Acta , vol.51 , pp. 1680-1694
    • Lang, G.G.1    Ujvari, M.2    Rokob, T.A.3    Inzelt, G.4
  • 43
    • 1842453356 scopus 로고    scopus 로고
    • Comparisons of platinum, gold, palladium and glassy carbon as electrode materials in the design of biosensors for glutamate
    • R.D. O'Neill, S.-C. Chang, J.P. Lowry, and C.J. McNeil Comparisons of platinum, gold, palladium and glassy carbon as electrode materials in the design of biosensors for glutamate Biosensors and Bioelectronics 19 2004 1521 1528
    • (2004) Biosensors and Bioelectronics , vol.19 , pp. 1521-1528
    • O'Neill, R.D.1    Chang, S.-C.2    Lowry, J.P.3    McNeil, C.J.4
  • 44
    • 68249159417 scopus 로고    scopus 로고
    • Decreasing the polymerization potential improves the selectivity of PPD-coated disc biosensors for glutamate
    • S. Govindarajan, and C.J. McNeil Decreasing the polymerization potential improves the selectivity of PPD-coated disc biosensors for glutamate Analytical Letters 42 2009 739 745
    • (2009) Analytical Letters , vol.42 , pp. 739-745
    • Govindarajan, S.1    McNeil, C.J.2
  • 45
    • 0001372793 scopus 로고    scopus 로고
    • Reduction of interference response at a hydrogen peroxide detecting electrode using electropolymerized films of substituted naphthalenes
    • L.J. Murphy Reduction of interference response at a hydrogen peroxide detecting electrode using electropolymerized films of substituted naphthalenes Analytical Chemistry 70 1998 2928 2935
    • (1998) Analytical Chemistry , vol.70 , pp. 2928-2935
    • Murphy, L.J.1
  • 46
    • 27144547820 scopus 로고    scopus 로고
    • Real-time monitoring of l-glutamate release from mouse brain slices under ischemia with a glass capillary-based enzyme electrode
    • N. Nakamura, K. Negishi, A. Hirano, and M. Sugawara Real-time monitoring of l-glutamate release from mouse brain slices under ischemia with a glass capillary-based enzyme electrode Analytical and Bioanalytical Chemistry 383 2005 660 667
    • (2005) Analytical and Bioanalytical Chemistry , vol.383 , pp. 660-667
    • Nakamura, N.1    Negishi, K.2    Hirano, A.3    Sugawara, M.4
  • 47
  • 48
    • 66149114037 scopus 로고    scopus 로고
    • Contributions by a novel edge effect to the permselectivity of an electrosynthesized polymer for microbiosensor applications
    • S.A. Rothwell, M.E. Kinsella, Z.M. Zain, P.A. Serra, G. Rocchitta, J.P. Lowry, and R.D. O'Neill Contributions by a novel edge effect to the permselectivity of an electrosynthesized polymer for microbiosensor applications Analytical Chemistry 81 2009 3911 3918
    • (2009) Analytical Chemistry , vol.81 , pp. 3911-3918
    • Rothwell, S.A.1    Kinsella, M.E.2    Zain, Z.M.3    Serra, P.A.4    Rocchitta, G.5    Lowry, J.P.6    O'Neill, R.D.7
  • 49
    • 0000953523 scopus 로고
    • Characterization of glucose oxidase-modified poly(phenylenediamine)- coated electrodes in vitro and in vivo: Homogeneous interference by ascorbic acid in hydrogen peroxide detection
    • J.P. Lowry, K. McAteer, S.S. El Atrash, A. Duff, and R.D. O'Neill Characterization of glucose oxidase-modified poly(phenylenediamine)-coated electrodes in vitro and in vivo: homogeneous interference by ascorbic acid in hydrogen peroxide detection Analytical Chemistry 66 1994 1754 1761
    • (1994) Analytical Chemistry , vol.66 , pp. 1754-1761
    • Lowry, J.P.1    McAteer, K.2    El Atrash, S.S.3    Duff, A.4    O'Neill, R.D.5
  • 50
    • 33750708570 scopus 로고    scopus 로고
    • In vivo chemical sensors: Tackling biocompatibility
    • M. Frost, and M.E. Meyerhoff In vivo chemical sensors: tackling biocompatibility Analytical Chemistry 78 2006 7370 7377
    • (2006) Analytical Chemistry , vol.78 , pp. 7370-7377
    • Frost, M.1    Meyerhoff, M.E.2
  • 51
    • 79955031514 scopus 로고    scopus 로고
    • Poly-cobalt[tetrakis(o-aminophenyl)porphyrin] nanowire and single-walled carbon nanotube for the analysis of hydrogen peroxide
    • H. Jeong, M.S. Ahmed, and S. Jeon Poly-cobalt[tetrakis(o-aminophenyl) porphyrin] nanowire and single-walled carbon nanotube for the analysis of hydrogen peroxide Journal of Nanoscience and Nanotechnology 11 2011 987 993
    • (2011) Journal of Nanoscience and Nanotechnology , vol.11 , pp. 987-993
    • Jeong, H.1    Ahmed, M.S.2    Jeon, S.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.