Volumn 178, Issue , 2013, Pages 663-670

Interdigitated microelectrode biosensor for bacterial biofilm growth monitoring by impedance spectroscopy technique in 96-well microtiter plates

Author keywords

Biofilm detection; Catheter related sepsis; Impedance microbiology; In vitro real time monitoring; Interdigitated microelectrode; Intravascular access port

Indexed keywords

96-WELL MICROTITER PLATE; ACCESS PORTS; BACTERIAL BIOFILM; BIOLOGICAL EVOLUTION; CHRONIC INFECTION; HEALTH-CARE SYSTEM; HIGH COSTS; IMPEDANCE MICROBIOLOGY; IMPEDANCE SPECTROSCOPY; IMPLANTABLE DEVICES; IN-VITRO ASSAYS; IN-VIVO ANALYSIS; INTERDIGITATED MICROELECTRODES; INTRAVASCULAR; MONITORING TOOLS; PHYSIOLOGICAL PARAMETERS; REAL TIME MONITORING; STAPHYLOCOCCUS AUREUS; STAPHYLOCOCCUS EPIDERMIDIS; THERAPEUTIC TOOLS;

EID: 84873355103     PISSN: 09254005     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.snb.2013.01.027     Document Type: Article
Times cited : (64)

References (29)
  • 2
    • 0036711963 scopus 로고    scopus 로고
    • Biofilms: Microbial life on surfaces
    • R.M. Donlan Biofilms: microbial life on surfaces Emerging Infectious Diseases 8 2002 881 890
    • (2002) Emerging Infectious Diseases , vol.8 , pp. 881-890
    • Donlan, R.M.1
  • 4
    • 0035029378 scopus 로고    scopus 로고
    • Biofilms and device-associated infections
    • R.M. Donlan Biofilms and device-associated infections Emerging Infectious Diseases 7 2001 277 281
    • (2001) Emerging Infectious Diseases , vol.7 , pp. 277-281
    • Donlan, R.M.1
  • 6
    • 3142677892 scopus 로고    scopus 로고
    • Design and fabrication of a microimpedance biosensor for bacterial detection
    • S.M. Radke, and E.C. Alocilja Design and fabrication of a microimpedance biosensor for bacterial detection IEEE Sensors Journal 4 2004 434 440
    • (2004) IEEE Sensors Journal , vol.4 , pp. 434-440
    • Radke, S.M.1    Alocilja, E.C.2
  • 8
    • 0017879651 scopus 로고
    • Electrical impedance measurements: Rapid method for detecting and monitoring microorganisms
    • P. Cady, S.W. Dufour, J. Shaw, and S.J. Kraeger Electrical impedance measurements: rapid method for detecting and monitoring microorganisms Journal of Clinical Microbiology 7 1978 265 272
    • (1978) Journal of Clinical Microbiology , vol.7 , pp. 265-272
    • Cady, P.1    Dufour, S.W.2    Shaw, J.3    Kraeger, S.J.4
  • 10
    • 38349133990 scopus 로고    scopus 로고
    • Electrical/electrochemical impedance for rapid detection of food borne pathogenic bacteria
    • L. Yang, and R. Bashir Electrical/electrochemical impedance for rapid detection of food borne pathogenic bacteria Biotechnology Advances 26 2008 135 150
    • (2008) Biotechnology Advances , vol.26 , pp. 135-150
    • Yang, L.1    Bashir, R.2
  • 14
    • 67349115176 scopus 로고    scopus 로고
    • Interdigitated array microelectrodes based impedance biosensors for detection of bacterial cells
    • M. Varshney, and Y. Li Interdigitated array microelectrodes based impedance biosensors for detection of bacterial cells Biosensors and Bioelectronics 24 2009 2951 2960
    • (2009) Biosensors and Bioelectronics , vol.24 , pp. 2951-2960
    • Varshney, M.1    Li, Y.2
  • 15
    • 38149044839 scopus 로고    scopus 로고
    • Electrical impedance spectroscopy for detection of bacterial cells in suspensions using interdigitated microelectrodes
    • L. Yang Electrical impedance spectroscopy for detection of bacterial cells in suspensions using interdigitated microelectrodes Talanta 74 2008 1621 1629
    • (2008) Talanta , vol.74 , pp. 1621-1629
    • Yang, L.1
  • 16
    • 35748931751 scopus 로고    scopus 로고
    • A label-free, microfluidics and interdigitated array microelectrode-based impedance biosensor in combination with nanoparticles immuno separation for detection of Escherichia coli O157:H7 in food samples
    • M. Varshney, Y. Li, B. Srinivasan, and S. Tung A label-free, microfluidics and interdigitated array microelectrode-based impedance biosensor in combination with nanoparticles immuno separation for detection of Escherichia coli O157:H7 in food samples Sensors and Actuators B: Chemical 128 2007 99 107
    • (2007) Sensors and Actuators B: Chemical , vol.128 , pp. 99-107
    • Varshney, M.1    Li, Y.2    Srinivasan, B.3    Tung, S.4
  • 18
    • 11144231293 scopus 로고    scopus 로고
    • A high density microelectrode array biosensor for detection of E. coli O157:H7
    • S.M. Radke, and E.C. Alocilja A high density microelectrode array biosensor for detection of E. coli O157:H7 Biosensors and Bioelectronics 20 2005 1662 1667
    • (2005) Biosensors and Bioelectronics , vol.20 , pp. 1662-1667
    • Radke, S.M.1    Alocilja, E.C.2
  • 19
    • 79958172854 scopus 로고    scopus 로고
    • A new interdigitated array microelectrode-oxide-silicon sensor with label-free, high sensitivity and specificity for fast bacteria detection
    • X. Tang, D. Flandre, J. Raskin, Y. Nizet, L. Moreno-Hagelsieb, R. Pampin, and L.A. Francis A new interdigitated array microelectrode-oxide-silicon sensor with label-free, high sensitivity and specificity for fast bacteria detection Sensors and Actuators B: Chemical 156 2011 578 587
    • (2011) Sensors and Actuators B: Chemical , vol.156 , pp. 578-587
    • Tang, X.1    Flandre, D.2    Raskin, J.3    Nizet, Y.4    Moreno-Hagelsieb, L.5    Pampin, R.6    Francis, L.A.7
  • 20
    • 0037290582 scopus 로고    scopus 로고
    • Selective detection of viable bacteria using dielectrophoretic impedance measurement method
    • J. Suehiro, R. Hamada, D. Noutomi, M. Shutou, and M. Hara Selective detection of viable bacteria using dielectrophoretic impedance measurement method Journal of Electrostatics 57 2003 157 168
    • (2003) Journal of Electrostatics , vol.57 , pp. 157-168
    • Suehiro, J.1    Hamada, R.2    Noutomi, D.3    Shutou, M.4    Hara, M.5
  • 21
    • 33748289500 scopus 로고    scopus 로고
    • Selective detection of bacteria by a dielectrophoretic impedance measurement method using an antibody-immobilized electrode chip
    • J. Suehiro, A. Ohtsubo, T. Hatano, and M. Hara Selective detection of bacteria by a dielectrophoretic impedance measurement method using an antibody-immobilized electrode chip Sensors and Actuators B: Chemical 119 2006 319 326
    • (2006) Sensors and Actuators B: Chemical , vol.119 , pp. 319-326
    • Suehiro, J.1    Ohtsubo, A.2    Hatano, T.3    Hara, M.4
  • 22
    • 1642370490 scopus 로고    scopus 로고
    • Interdigitated microelectrode (IME) impedance sensor for the detection of viable Salmonella typhimurium
    • L. Yang, Y. Li, C.L. Griffis, and M.G. Johnson Interdigitated microelectrode (IME) impedance sensor for the detection of viable Salmonella typhimurium Biosensors and Bioelectronics 19 2004 1139 1147
    • (2004) Biosensors and Bioelectronics , vol.19 , pp. 1139-1147
    • Yang, L.1    Li, Y.2    Griffis, C.L.3    Johnson, M.G.4
  • 23
    • 37449021259 scopus 로고    scopus 로고
    • Double interdigitated array microelectrode-based impedance biosensor for detection of viable Escherichia coli O157:H7 in growth medium
    • M. Varshney, and Y. Li Double interdigitated array microelectrode-based impedance biosensor for detection of viable Escherichia coli O157:H7 in growth medium Talanta 74 2008 518 525
    • (2008) Talanta , vol.74 , pp. 518-525
    • Varshney, M.1    Li, Y.2
  • 24
    • 33646693907 scopus 로고    scopus 로고
    • Approved Standard M07-A8. Methods for dilution antimicrobial susceptibility test for bacteria that grow aerobically
    • Clinical and Laboratoy Standard Institute
    • Clinical and Laboratoy Standard Institute Approved Standard M07-A8. Methods for dilution antimicrobial susceptibility test for bacteria that grow aerobically Approved Standard 29 2009 16 19
    • (2009) Approved Standard , vol.29 , pp. 16-19
  • 25
    • 0032076903 scopus 로고    scopus 로고
    • Elimination of intraluminal colonization by antibiotic lock in silicone vascular catheters
    • D.A. Andris, E.A. Krzywda, C.E. Edmiston, C.J. Krepel, and C.M. Gohr Elimination of intraluminal colonization by antibiotic lock in silicone vascular catheters Nutrition 14 1998 427 432
    • (1998) Nutrition , vol.14 , pp. 427-432
    • Andris, D.A.1    Krzywda, E.A.2    Edmiston, C.E.3    Krepel, C.J.4    Gohr, C.M.5
  • 26
    • 84864383320 scopus 로고    scopus 로고
    • Real time monitoring of the impedance characteristics of Staphylococcal bacterial biofilm cultures with a modified CDC reactor system
    • J. Paredes, S. Becerro, F. Arizti, A. Aguinaga, J.L. Del Pozo, and S. Arana Real time monitoring of the impedance characteristics of Staphylococcal bacterial biofilm cultures with a modified CDC reactor system Biosensors and Bioelectronics 38 2012 226 232
    • (2012) Biosensors and Bioelectronics , vol.38 , pp. 226-232
    • Paredes, J.1    Becerro, S.2    Arizti, F.3    Aguinaga, A.4    Del Pozo, J.L.5    Arana, S.6
  • 28
    • 33947713763 scopus 로고    scopus 로고
    • Interdigitated array microelectrode based impedance biosensor coupled with magnetic nanoparticle-antibody conjugates for detection of Escherichia coli O157:H7 in food samples
    • M. Varshney, and Y. Li Interdigitated array microelectrode based impedance biosensor coupled with magnetic nanoparticle-antibody conjugates for detection of Escherichia coli O157:H7 in food samples Biosensors and Bioelectronics 22 2007 2408 2414
    • (2007) Biosensors and Bioelectronics , vol.22 , pp. 2408-2414
    • Varshney, M.1    Li, Y.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.