메뉴 건너뛰기




Volumn 11, Issue , 2012, Pages 1634-1637

Impact of microwave pulses on thermoacoustic imaging applications

Author keywords

Breast cancer detection; image resolution; pulse waveform; pulse width; thermoacoustic imaging (TAI)

Indexed keywords

ACOUSTIC PRESSURES; ACOUSTIC SIGNALS; BREAST CANCER DETECTION; DIFFERENT SIZES; FREQUENCY DOMAINS; IMAGE SPATIAL RESOLUTION; KEY PARAMETERS; MICROWAVE PULSE; PEAK VALUES; PEAK-TO-PEAK; PULSE WAVEFORMS; PULSEWIDTHS; SQUARE PULSE; THERMOACOUSTIC IMAGING; TIME DOMAIN; TIME INTERVAL; WAVE FORMS;

EID: 84873340559     PISSN: 15361225     EISSN: None     Source Type: Journal    
DOI: 10.1109/LAWP.2013.2237743     Document Type: Article
Times cited : (38)

References (10)
  • 1
    • 0033932015 scopus 로고    scopus 로고
    • Breast cancer in vivo: Contrast enhancement with thermo-acoustic CT at 434 MHz - Feasibility study
    • Jul
    • R. A. Kruger, K. D. Miller, H. E. Reynolds, W. L. Kiser, D. R. Reinecke, and G. A. Kruger, "Breast cancer in vivo: Contrast enhancement with thermo-acoustic CT at 434 MHz - Feasibility study," Radiology, vol. 216, no. 1, pp. 279-283, Jul. 2000.
    • (2000) Radiology , vol.216 , Issue.1 , pp. 279-283
    • Kruger, R.A.1    Miller, K.D.2    Reynolds, H.E.3    Kiser, W.L.4    Reinecke, D.R.5    Kruger, G.A.6
  • 2
    • 0032613955 scopus 로고    scopus 로고
    • Microwave-induced acoustic imaging of biological tissues
    • Sep
    • L.V.Wang,X.Zhao, H. Sun, andG.Ku, "Microwave-induced acoustic imaging of biological tissues," Rev. Sci. Instrum., vol. 70, no. 9, pp. 3744-3748, Sep. 1999.
    • (1999) Rev. Sci. Instrum. , vol.70 , Issue.9 , pp. 3744-3748
    • Wang, L.V.1    Zhao, X.2    Sun, H.3    Ku, G.4
  • 3
    • 0032807503 scopus 로고    scopus 로고
    • A new theoretical approach to photoacoustic signal generation
    • Aug
    • C. G. A. Hoelen and F. F. M. de Mul, "A new theoretical approach to photoacoustic signal generation," J. Acoust. Soc. Amer., vol. 106, no. 2, pp. 695-706, Aug. 1999.
    • (1999) J. Acoust. Soc. Amer. , vol.106 , Issue.2 , pp. 695-706
    • Hoelen, C.G.A.1    De Mul, F.F.M.2
  • 4
    • 84864276232 scopus 로고    scopus 로고
    • Spectroscopic thermoacoustic imaging of water and fat composition
    • Jul
    • D. R. Bauer, X. Wang, J. L. Vollin, H. Xin, and R. Witte, "Spectroscopic thermoacoustic imaging of water and fat composition," Appl. Phys. Lett., vol. 101, no. 3, pp. 033705-033705-4, Jul. 2012.
    • (2012) Appl. Phys. Lett. , vol.101 , Issue.3 , pp. 033705-033705
    • Bauer, D.R.1    Wang, X.2    Vollin, J.L.3    Xin, H.4    Witte, R.5
  • 5
    • 50449107101 scopus 로고    scopus 로고
    • Microwave-induced thermoacoustic scanning CT for high-contrast and noninvasive breast cancer imaging
    • Sep
    • L. Nie, D. Xing, Q. Zhou, D. Yang, and H. Guo, "Microwave-induced thermoacoustic scanning CT for high-contrast and noninvasive breast cancer imaging," Med. Phys., vol. 35, no. 9, pp. 4026-4032, Sep. 2008.
    • (2008) Med. Phys. , vol.35 , Issue.9 , pp. 4026-4032
    • Nie, L.1    Xing, D.2    Zhou, Q.3    Yang, D.4    Guo, H.5
  • 6
    • 80655128861 scopus 로고    scopus 로고
    • Effect of excitation pulse width on thermoacoustic signal characteristics and the corresponding algorithm for optimization of imaging resolution
    • Oct
    • C. Lou, L. Nie, and D. Xu, "Effect of excitation pulse width on thermoacoustic signal characteristics and the corresponding algorithm for optimization of imaging resolution," J. Appl. Phys., vol. 110, no. 8, p. 083101, Oct. 2011.
    • (2011) J. Appl. Phys. , vol.110 , Issue.8 , pp. 083101
    • Lou, C.1    Nie, L.2    Xu, D.3
  • 7
    • 84866526791 scopus 로고    scopus 로고
    • Microwave-induced thermoacoustic imagingmodel for potential breast cancer detection
    • Oct
    • X.Wang, D. R. Bauer, R.Witte, and H. Xin, "Microwave-induced thermoacoustic imagingmodel for potential breast cancer detection," IEEE Trans. Biomed. Eng., vol. 59, no. 10, pp. 2782-2791, Oct. 2012.
    • (2012) IEEE Trans. Biomed. Eng. , vol.59 , Issue.10 , pp. 2782-2791
    • Wang, X.1    Bauer, D.R.2    Witte, R.3    Xin, H.4
  • 8
    • 77956192926 scopus 로고    scopus 로고
    • Spectral difference between microwave radar andmicrowave-induced thermoacoustic signals
    • K. G. Zhu and M. Popovic, "Spectral difference between microwave radar andmicrowave-induced thermoacoustic signals," IEEE Antennas Wireless Propag. Lett., vol. 8, pp. 1259-1262, 2009.
    • (2009) IEEE Antennas Wireless Propag. Lett. , vol.8 , pp. 1259-1262
    • Zhu, K.G.1    Popovic, M.2
  • 9
    • 0036628475 scopus 로고    scopus 로고
    • Time-domain reconstruction for thermoacoustic tomography in a spherical geometry
    • Jul
    • M. Xu and L. V. Wang, "Time-domain reconstruction for thermoacoustic tomography in a spherical geometry," IEEE Trans. Med. Imag., vol. 21, no. 7, pp. 814-822, Jul. 2002.
    • (2002) IEEE Trans. Med. Imag. , vol.21 , Issue.7 , pp. 814-822
    • Xu, M.1    Wang, L.V.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.