메뉴 건너뛰기




Volumn 85, Issue 3, 2013, Pages 700-706

Relationship of imaging frequency and planning margin to account for intrafraction prostate motion: Analysis based on real-time monitoring data

Author keywords

[No Author keywords available]

Indexed keywords

ANTERIOR POSTERIORS; IMAGING PROTOCOL; INTENSITY MODULATED RADIATION THERAPY; MID-SAGITTAL PLANES; PROSTATE CANCERS; PROSTATE POSITION; REAL TIME MONITORING; SECOND IMAGING; TARGET COVERAGE; TREATMENT TIME; VECTOR DISPLACEMENT;

EID: 84873324971     PISSN: 03603016     EISSN: 1879355X     Source Type: Journal    
DOI: 10.1016/j.ijrobp.2012.05.044     Document Type: Article
Times cited : (41)

References (14)
  • 1
    • 37049030610 scopus 로고    scopus 로고
    • Planning target margin calculations for prostate radiotherapy based on intrafraction and interfraction motion using four localization methods
    • C. Beltran, M.G. Herman, and B.J. Davis Planning target margin calculations for prostate radiotherapy based on intrafraction and interfraction motion using four localization methods Int J Radiat Oncol Biol Phys 70 2008 289 295
    • (2008) Int J Radiat Oncol Biol Phys , vol.70 , pp. 289-295
    • Beltran, C.1    Herman, M.G.2    Davis, B.J.3
  • 2
    • 77952574013 scopus 로고    scopus 로고
    • Hypofractionated radiotherapy for favorable risk prostate cancer
    • N. Rene, S. Faria, and F. Cury Hypofractionated radiotherapy for favorable risk prostate cancer Int J Radiat Oncol Biol Phys 77 2010 805 810
    • (2010) Int J Radiat Oncol Biol Phys , vol.77 , pp. 805-810
    • Rene, N.1    Faria, S.2    Cury, F.3
  • 3
    • 34548684114 scopus 로고    scopus 로고
    • Prostate planning treatment volume margin calculation based on the ExacTrac X-Ray 6D image-guided system: Margins for various clinical implementations
    • S. Alonso-Arrizabalaga, L. Brualla González, and J.V. Roselló Ferrando Prostate planning treatment volume margin calculation based on the ExacTrac X-Ray 6D image-guided system: margins for various clinical implementations Int J Radiat Oncol Biol Phys 69 2007 936 943
    • (2007) Int J Radiat Oncol Biol Phys , vol.69 , pp. 936-943
    • Alonso-Arrizabalaga, S.1    Brualla González, L.2    Roselló Ferrando, J.V.3
  • 4
    • 42949150341 scopus 로고    scopus 로고
    • Dosimetric consequences of intrafraction prostate motion
    • H.S. Li, I.J. Chetty, and C.A. Enke Dosimetric consequences of intrafraction prostate motion Int J Radiat Oncol Biol Phys 71 2008 801 812
    • (2008) Int J Radiat Oncol Biol Phys , vol.71 , pp. 801-812
    • Li, H.S.1    Chetty, I.J.2    Enke, C.A.3
  • 5
    • 77958586799 scopus 로고    scopus 로고
    • Emerging technologies in prostate cancer radiation therapy: Improving the therapeutic window
    • M.C. Biagioli, and S.E. Hoffe Emerging technologies in prostate cancer radiation therapy: improving the therapeutic window Cancer Control 17 2010 223 232
    • (2010) Cancer Control , vol.17 , pp. 223-232
    • Biagioli, M.C.1    Hoffe, S.E.2
  • 6
    • 33645368752 scopus 로고    scopus 로고
    • Influence of intrafraction motion on margins for prostate radiotherapy
    • D.W. Litzenberg, J.M. Balter, and S.W. Hadley Influence of intrafraction motion on margins for prostate radiotherapy Int J Radiat Oncol Biol Phys 65 2006 548 553
    • (2006) Int J Radiat Oncol Biol Phys , vol.65 , pp. 548-553
    • Litzenberg, D.W.1    Balter, J.M.2    Hadley, S.W.3
  • 7
    • 33646487136 scopus 로고    scopus 로고
    • Target localization and real-time tracking using the Calypso 4D localization system in patients with localized prostate cancer
    • T.R. Willoughby, P.A. Kupelian, and J. Pouliot Target localization and real-time tracking using the Calypso 4D localization system in patients with localized prostate cancer Int J Radiat Oncol Biol Phys 65 2006 528 534
    • (2006) Int J Radiat Oncol Biol Phys , vol.65 , pp. 528-534
    • Willoughby, T.R.1    Kupelian, P.A.2    Pouliot, J.3
  • 8
    • 33847328730 scopus 로고    scopus 로고
    • Multi-institutional clinical experience with the Calypso System in localization and continuous, real-time monitoring of the prostate gland during external radiotherapy
    • P. Kupelian, T. Willoughby, and A. Mahadevan Multi-institutional clinical experience with the Calypso System in localization and continuous, real-time monitoring of the prostate gland during external radiotherapy Int J Radiat Oncol Biol Phys 67 2007 1088 1098
    • (2007) Int J Radiat Oncol Biol Phys , vol.67 , pp. 1088-1098
    • Kupelian, P.1    Willoughby, T.2    Mahadevan, A.3
  • 9
    • 45449088673 scopus 로고    scopus 로고
    • Observations on real-time prostate gland motion using electromagnetic tracking
    • K.M. Langen, T.R. Willoughby, and S.L. Meeks Observations on real-time prostate gland motion using electromagnetic tracking Int J Radiat Oncol Biol Phys 71 2008 1084 1090
    • (2008) Int J Radiat Oncol Biol Phys , vol.71 , pp. 1084-1090
    • Langen, K.M.1    Willoughby, T.R.2    Meeks, S.L.3
  • 10
    • 42949114786 scopus 로고    scopus 로고
    • Prostate intrafraction motion evaluation using kV fluoroscopy during treatment delivery: A feasibility and accuracy study
    • J. Adamson, and Q. Wu Prostate intrafraction motion evaluation using kV fluoroscopy during treatment delivery: a feasibility and accuracy study Med Phys 35 2008 1793 1806
    • (2008) Med Phys , vol.35 , pp. 1793-1806
    • Adamson, J.1    Wu, Q.2
  • 11
    • 78549259670 scopus 로고    scopus 로고
    • Assessment of planning target volume margins for intensity-modulated radiotherapy of the prostate gland: Role of daily inter- and intrafraction motion
    • J.A. Tanyi, T. He, and P.A. Summers Assessment of planning target volume margins for intensity-modulated radiotherapy of the prostate gland: role of daily inter- and intrafraction motion Int J Radiat Oncol Biol Phys 78 2010 1579 1585
    • (2010) Int J Radiat Oncol Biol Phys , vol.78 , pp. 1579-1585
    • Tanyi, J.A.1    He, T.2    Summers, P.A.3
  • 12
    • 49549093853 scopus 로고    scopus 로고
    • Intrafractional motion of the prostate during hypofractionated radiotherapy
    • Y. Xie, D. Djajaputra, and C.R. King Intrafractional motion of the prostate during hypofractionated radiotherapy Int J Radiat Oncol Biol Phys 72 2008 236 246
    • (2008) Int J Radiat Oncol Biol Phys , vol.72 , pp. 236-246
    • Xie, Y.1    Djajaputra, D.2    King, C.R.3
  • 13
    • 33748873299 scopus 로고    scopus 로고
    • IGRT of prostate cancer; Is the margin reduction gained from daily IG time-dependent?
    • M. Enmark, S. Korreman, and H. Nyström IGRT of prostate cancer; is the margin reduction gained from daily IG time-dependent? Acta Oncol 45 2006 907 914
    • (2006) Acta Oncol , vol.45 , pp. 907-914
    • Enmark, M.1    Korreman, S.2    Nyström, H.3
  • 14
    • 11144279948 scopus 로고    scopus 로고
    • Quantification of shape variation of prostate and seminal vesicles during external beam radiotherapy
    • K.E.I. Deurloo, R.J.H.M. Steenbakkers, and L.J. Zijp Quantification of shape variation of prostate and seminal vesicles during external beam radiotherapy Int J Radiat Oncol Biol Phys 61 2005 228 238
    • (2005) Int J Radiat Oncol Biol Phys , vol.61 , pp. 228-238
    • Deurloo, K.E.I.1    Steenbakkers, R.J.H.M.2    Zijp, L.J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.