메뉴 건너뛰기




Volumn 105, Issue , 2013, Pages 244-251

Utilization and performance evaluation of a surplus air heat pump system for greenhouse cooling and heating

Author keywords

Air source heat pump; Energy conservation; Greenhouse environmental control; Solar thermal energy; Surplus energy

Indexed keywords

AIR SOURCE HEAT PUMPS; ENERGY CONSERVATION; ENVIRONMENTAL MANAGEMENT; FOSSIL FUELS; GLOBAL WARMING; GREENHOUSES; HEAT PUMP SYSTEMS; SOLAR ENERGY;

EID: 84873324587     PISSN: 03062619     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.apenergy.2012.12.038     Document Type: Article
Times cited : (84)

References (33)
  • 2
    • 84873287526 scopus 로고    scopus 로고
    • BP. BP statistical review of world energy, June 2011;
    • BP. BP statistical review of world energy, June 2011; 2011.
    • (2011)
  • 3
    • 67349168409 scopus 로고    scopus 로고
    • Theoretical performance assessment of an integrated photovoltaic and earth air heat exchanger greenhouse using energy and exergy analysis methods
    • Nayak S., Tiwari G.N. Theoretical performance assessment of an integrated photovoltaic and earth air heat exchanger greenhouse using energy and exergy analysis methods. Energy Build 2009, 41:888-896.
    • (2009) Energy Build , vol.41 , pp. 888-896
    • Nayak, S.1    Tiwari, G.N.2
  • 5
    • 77955710386 scopus 로고    scopus 로고
    • Advances in heat pump systems: a review
    • Chua K.J., Chou S.K., Yang W.M. Advances in heat pump systems: a review. Appl Energy 2010, 87:3611-3624.
    • (2010) Appl Energy , vol.87 , pp. 3611-3624
    • Chua, K.J.1    Chou, S.K.2    Yang, W.M.3
  • 6
    • 84873303799 scopus 로고    scopus 로고
    • Heat recovery characteristics of the hot water supply system with exhaust heat recovery unit attached to the hot air heater for plant bed heating in the greenhouse
    • Kim Y.J., Ryou Y.S., Chang J.T., Kang K.C., Lee K.J., Shin C.W. Heat recovery characteristics of the hot water supply system with exhaust heat recovery unit attached to the hot air heater for plant bed heating in the greenhouse. J Biosyst Eng 2000, 25:221-226.
    • (2000) J Biosyst Eng , vol.25 , pp. 221-226
    • Kim, Y.J.1    Ryou, Y.S.2    Chang, J.T.3    Kang, K.C.4    Lee, K.J.5    Shin, C.W.6
  • 8
    • 0346154909 scopus 로고    scopus 로고
    • On the study of an energy-efficient greenhouse for heating, cooling and dehumidification applications
    • Chou S.K., Chua K.J., Ho J.C., Ooi C.L. On the study of an energy-efficient greenhouse for heating, cooling and dehumidification applications. Appl Energy 2004, 77:355-373.
    • (2004) Appl Energy , vol.77 , pp. 355-373
    • Chou, S.K.1    Chua, K.J.2    Ho, J.C.3    Ooi, C.L.4
  • 9
    • 57349161968 scopus 로고    scopus 로고
    • Evaluation of ground-source heat pump combined latent heat storage system performance in greenhouse heating
    • Benli H., Durmus A. Evaluation of ground-source heat pump combined latent heat storage system performance in greenhouse heating. Energy Build 2009, 41:220-228.
    • (2009) Energy Build , vol.41 , pp. 220-228
    • Benli, H.1    Durmus, A.2
  • 10
    • 22544459954 scopus 로고    scopus 로고
    • Underground water-source loop heat-pump air-conditioning system applied in a residential building in Beijing
    • Chen C., Sun F-l, Feng L., Liu M. Underground water-source loop heat-pump air-conditioning system applied in a residential building in Beijing. Appl Energy 2005, 82:331-344.
    • (2005) Appl Energy , vol.82 , pp. 331-344
    • Chen, C.1    Sun, F.-L.2    Feng, L.3    Liu, M.4
  • 11
    • 33845494054 scopus 로고    scopus 로고
    • System optimization and experimental research on air source heat pump water heater
    • Zhang J., Wang R.Z., Wu J.Y. System optimization and experimental research on air source heat pump water heater. Appl Therm Eng 2007, 27:1029-1035.
    • (2007) Appl Therm Eng , vol.27 , pp. 1029-1035
    • Zhang, J.1    Wang, R.Z.2    Wu, J.Y.3
  • 12
    • 77955715181 scopus 로고    scopus 로고
    • Study on performance of solar assisted air source heat pump systems for hot water production in Hong Kong
    • Li H., Yang H. Study on performance of solar assisted air source heat pump systems for hot water production in Hong Kong. Appl Energy 2010, 87:2818-2825.
    • (2010) Appl Energy , vol.87 , pp. 2818-2825
    • Li, H.1    Yang, H.2
  • 13
    • 79959816452 scopus 로고    scopus 로고
    • Experimental research and operation optimization of an air-source heat pump water heater
    • Guo J.J., Wu J.Y., Wang R.Z., Li S. Experimental research and operation optimization of an air-source heat pump water heater. Appl Energy 2011, 88:4128-4138.
    • (2011) Appl Energy , vol.88 , pp. 4128-4138
    • Guo, J.J.1    Wu, J.Y.2    Wang, R.Z.3    Li, S.4
  • 14
    • 80053895957 scopus 로고    scopus 로고
    • Transient behavior and dynamic performance of cascade heat pump water heater with thermal storage system
    • Wu J., Yang Z., Wu Q., Zhu Y. Transient behavior and dynamic performance of cascade heat pump water heater with thermal storage system. Appl Energy 2012, 91:187-196.
    • (2012) Appl Energy , vol.91 , pp. 187-196
    • Wu, J.1    Yang, Z.2    Wu, Q.3    Zhu, Y.4
  • 15
    • 71849114329 scopus 로고    scopus 로고
    • Optimal design of district heating and cooling pipe network of seawater-source heat pump
    • Li X-l, Duanmu L., Shu H-w Optimal design of district heating and cooling pipe network of seawater-source heat pump. Energy Build 2010, 42:100-104.
    • (2010) Energy Build , vol.42 , pp. 100-104
    • Li, X.-L.1    Duanmu, L.2    Shu, H.-W.3
  • 16
    • 1642381247 scopus 로고    scopus 로고
    • Solar and ground source heat-pump system
    • Bi Y., Guo T., Zhang L., Chen L. Solar and ground source heat-pump system. Appl Energy 2004, 78:231-245.
    • (2004) Appl Energy , vol.78 , pp. 231-245
    • Bi, Y.1    Guo, T.2    Zhang, L.3    Chen, L.4
  • 17
    • 4944221350 scopus 로고    scopus 로고
    • Experimental performance analysis of a solar assisted ground-source heat pump greenhouse heating system
    • Ozgener O., Hepbasli A. Experimental performance analysis of a solar assisted ground-source heat pump greenhouse heating system. Energy Build 2005, 37:101-110.
    • (2005) Energy Build , vol.37 , pp. 101-110
    • Ozgener, O.1    Hepbasli, A.2
  • 18
    • 77955716941 scopus 로고    scopus 로고
    • Study on hybrid ground-coupled heat pump system for air-conditioning in hot-weather areas like Hong Kong
    • Man Y., Yang H., Wang J. Study on hybrid ground-coupled heat pump system for air-conditioning in hot-weather areas like Hong Kong. Appl Energy 2010, 87:2826-2833.
    • (2010) Appl Energy , vol.87 , pp. 2826-2833
    • Man, Y.1    Yang, H.2    Wang, J.3
  • 19
    • 13444274595 scopus 로고    scopus 로고
    • A modular approach to study the performance of a two-stage heat pump system for drying
    • Chua K.J., Chou S.K. A modular approach to study the performance of a two-stage heat pump system for drying. Appl Therm Eng 2005, 25:1363-1379.
    • (2005) Appl Therm Eng , vol.25 , pp. 1363-1379
    • Chua, K.J.1    Chou, S.K.2
  • 20
    • 84873465180 scopus 로고    scopus 로고
    • Experimental investigation of a multi-function heat pump under various operating modes
    • Cho C., Min Choi J. Experimental investigation of a multi-function heat pump under various operating modes. Renew Energy 2012.
    • (2012) Renew Energy
    • Cho, C.1    Min Choi, J.2
  • 21
    • 79955475232 scopus 로고    scopus 로고
    • Experimental study of an air-source heat pump for simultaneous heating and cooling - part 2: dynamic behaviour and two-phase thermosiphon defrosting technique
    • Byrne P., Miriel J., Lenat Y. Experimental study of an air-source heat pump for simultaneous heating and cooling - part 2: dynamic behaviour and two-phase thermosiphon defrosting technique. Appl Energy 2011, 88:3072-3078.
    • (2011) Appl Energy , vol.88 , pp. 3072-3078
    • Byrne, P.1    Miriel, J.2    Lenat, Y.3
  • 22
    • 80052259995 scopus 로고    scopus 로고
    • Defrosting method adopting dual hot gas bypass for an air-to-air heat pump
    • Choi H.-J., Kim B.-S., Kang D., Kim K.C. Defrosting method adopting dual hot gas bypass for an air-to-air heat pump. Appl Energy 2011, 88:4544-4555.
    • (2011) Appl Energy , vol.88 , pp. 4544-4555
    • Choi, H.-J.1    Kim, B.-S.2    Kang, D.3    Kim, K.C.4
  • 23
    • 80052272949 scopus 로고    scopus 로고
    • Field test investigation of the characteristics for the air source heat pump under two typical mal-defrost phenomena
    • Wang W., Xiao J., Guo Q.C., Lu W.P., Feng Y.C. Field test investigation of the characteristics for the air source heat pump under two typical mal-defrost phenomena. Appl Energy 2011, 88:4470-4480.
    • (2011) Appl Energy , vol.88 , pp. 4470-4480
    • Wang, W.1    Xiao, J.2    Guo, Q.C.3    Lu, W.P.4    Feng, Y.C.5
  • 24
    • 80053513215 scopus 로고    scopus 로고
    • A study of the reverse cycle defrosting performance on a multi-circuit outdoor coil unit in an air source heat pump - part I: experiments
    • Qu M., Xia L., Deng S., Jiang Y. A study of the reverse cycle defrosting performance on a multi-circuit outdoor coil unit in an air source heat pump - part I: experiments. Appl Energy 2012, 91:122-129.
    • (2012) Appl Energy , vol.91 , pp. 122-129
    • Qu, M.1    Xia, L.2    Deng, S.3    Jiang, Y.4
  • 25
    • 80054866864 scopus 로고    scopus 로고
    • A study of the reverse cycle defrosting performance on a multi-circuit outdoor coil unit in an air source heat pump - part II: modeling analysis
    • Qu M., Pan D., Xia L., Deng S., Jiang Y. A study of the reverse cycle defrosting performance on a multi-circuit outdoor coil unit in an air source heat pump - part II: modeling analysis. Appl Energy 2012, 91:274-280.
    • (2012) Appl Energy , vol.91 , pp. 274-280
    • Qu, M.1    Pan, D.2    Xia, L.3    Deng, S.4    Jiang, Y.5
  • 26
    • 84862306943 scopus 로고    scopus 로고
    • An experimental investigation on reverse-cycle defrosting performance for an air source heat pump using an electronic expansion valve
    • Qu M., Xia L., Deng S., Jiang Y. An experimental investigation on reverse-cycle defrosting performance for an air source heat pump using an electronic expansion valve. Appl Energy 2012, 97:327-333.
    • (2012) Appl Energy , vol.97 , pp. 327-333
    • Qu, M.1    Xia, L.2    Deng, S.3    Jiang, Y.4
  • 27
    • 84873312834 scopus 로고    scopus 로고
    • Solar energy storage effectiveness on double layered single span plastic greenhouse
    • Lee S.H., Ryou Y.S., Moon J.P., Yun N.K., Kwon J.K., Lee S.J., et al. Solar energy storage effectiveness on double layered single span plastic greenhouse. J Biosyst Eng 2011, 36:217-222.
    • (2011) J Biosyst Eng , vol.36 , pp. 217-222
    • Lee, S.H.1    Ryou, Y.S.2    Moon, J.P.3    Yun, N.K.4    Kwon, J.K.5    Lee, S.J.6
  • 28
    • 84873282066 scopus 로고
    • Characteristics of the stored and released thermal energy in plastic greenhouse with underground heat exchange system
    • Lee C.H., Park S.J., Kim Y.H., Kim C.S., Rhee J.Y. Characteristics of the stored and released thermal energy in plastic greenhouse with underground heat exchange system. J Kor Soc Agric Mach 1994, 19:222-231.
    • (1994) J Kor Soc Agric Mach , vol.19 , pp. 222-231
    • Lee, C.H.1    Park, S.J.2    Kim, Y.H.3    Kim, C.S.4    Rhee, J.Y.5
  • 29
    • 84873281698 scopus 로고    scopus 로고
    • Heating and cooling system for utilization of surplus air thermal energy in greenhouse and its control logic
    • Yang S.H., Lee C.G., Lee W.K., Ashtiani A.A., Kim J.Y., Lee S.D., et al. Heating and cooling system for utilization of surplus air thermal energy in greenhouse and its control logic. J Biosyst Eng 2012, 37:19-27.
    • (2012) J Biosyst Eng , vol.37 , pp. 19-27
    • Yang, S.H.1    Lee, C.G.2    Lee, W.K.3    Ashtiani, A.A.4    Kim, J.Y.5    Lee, S.D.6
  • 30
    • 84873279750 scopus 로고    scopus 로고
    • Estimation of surplus solar energy in greenhouse (i) - case study based on 1-2w type
    • Suh W.M., Bae Y.H., Ryou Y.S., Lee S.H., Yoon Y.C. Estimation of surplus solar energy in greenhouse (i) - case study based on 1-2w type. J Kor Soc Agric Eng 2009, 51:79-86.
    • (2009) J Kor Soc Agric Eng , vol.51 , pp. 79-86
    • Suh, W.M.1    Bae, Y.H.2    Ryou, Y.S.3    Lee, S.H.4    Yoon, Y.C.5
  • 31
    • 84870728102 scopus 로고    scopus 로고
    • Energy analysis and thermoeconomic assessment of the closed greenhouse - the largest commercial solar building
    • Vadiee A., Martin V. Energy analysis and thermoeconomic assessment of the closed greenhouse - the largest commercial solar building. Appl Energy 2013, 102:1256-1266.
    • (2013) Appl Energy , vol.102 , pp. 1256-1266
    • Vadiee, A.1    Martin, V.2
  • 32
    • 84873321818 scopus 로고    scopus 로고
    • Effects of fan-aspirated radiation shield for temperature measurement in greenhouse environment
    • Yang S.H., Lee C.G., Kim J.Y., Lee W.K., Ashtiani A.A., Rhee J.Y. Effects of fan-aspirated radiation shield for temperature measurement in greenhouse environment. J Biosyst Eng 2012, 37:245-251.
    • (2012) J Biosyst Eng , vol.37 , pp. 245-251
    • Yang, S.H.1    Lee, C.G.2    Kim, J.Y.3    Lee, W.K.4    Ashtiani, A.A.5    Rhee, J.Y.6
  • 33
    • 85021249250 scopus 로고    scopus 로고
    • KMA. Monthly weather report. Korea Meteorological Administration;
    • KMA. Monthly weather report. Korea Meteorological Administration; 2011.
    • (2011)


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.