메뉴 건너뛰기




Volumn 32, Issue 2, 2013, Pages 306-316

A Robust Ultrashort TE (UTE) imaging method with corrected k-space trajectory by using parametric multiple function model of gradient waveform

Author keywords

Correction method; gradient hardware; image reconstruction; magnetic resonance imaging (MRI); ultrashort echo time

Indexed keywords

CLINICAL EXAMINATION; CLINICAL USE; CORRECTION METHOD; DECAY TIME; DELAY ERRORS; ECHO SIGNALS; ECHO TIME; GRADIENT STRENGTH; GRADIENT SYSTEMS; GRADIENT TIME; GRADIENT WAVEFORMS; IMAGE DEGRADATION; IMAGING METHOD; K-SPACE; MULTIPLE FUNCTION; RADIAL SAMPLING; SHORT T2; TRAJECTORY ERRORS; WAVEFORM DISTORTIONS;

EID: 84873308910     PISSN: 02780062     EISSN: None     Source Type: Journal    
DOI: 10.1109/TMI.2012.2226050     Document Type: Article
Times cited : (17)

References (22)
  • 1
    • 33751368661 scopus 로고    scopus 로고
    • Clinical ultrashort echo time imaging of bone and other connective tissues
    • DOI 10.1002/nbm.1100
    • M. D. Robson and G. M. Bydder, "Clinical ultrashort echo time imaging of bone and other connective tissues," NMR Biomed., vol. 19, pp. 765-780, Nov. 2006. (Pubitemid 44811542)
    • (2006) NMR in Biomedicine , vol.19 , Issue.7 , pp. 765-780
    • Robson, M.D.1    Bydder, G.M.2
  • 2
    • 33846799432 scopus 로고    scopus 로고
    • Magnetic resonance imaging with ultrashort TE (UTE) PULSE sequences: Technical considerations
    • DOI 10.1002/jmri.20851
    • D. J. Tyler, M. D. Robson, R. M. Henkelman, I. R. Young, and G. M. Bydder, "Magnetic resonance imaging with ultrashort TE (UTE) PULSE sequence: Technical considerations J. Magn. Reson Imag., vol. 25, pp. 279-289, Feb. 2007. (Pubitemid 46204578)
    • (2007) Journal of Magnetic Resonance Imaging , vol.25 , Issue.2 , pp. 279-289
    • Tyler, D.J.1    Robson, M.D.2    Henkelman, R.M.3    Young, I.R.4    Bydder, G.M.5
  • 3
    • 33846811674 scopus 로고    scopus 로고
    • Magnetic resonance imaging of entheses using Ultrashort TE (UTE) pulse sequences
    • DOI 10.1002/jmri.20825
    • M. Benjamin and G. M. Bydder, "Magnetic resonance imaging of entheses using ultrashort TE (UTE) pulse sequences J. Magn. Reson Imag., vol. 25, pp. 381-389, Feb. 2007. (Pubitemid 46204586)
    • (2007) Journal of Magnetic Resonance Imaging , vol.25 , Issue.2 , pp. 381-389
    • Benjamin, M.1    Bydder, G.M.2
  • 4
    • 84873289283 scopus 로고    scopus 로고
    • Ultrashort TEMRI of the osteochondral junction of the knee at 3 T: Identification of anatomic structures contributing to signal intensity
    • Honolulu, HI
    • W. C. Bae, J. R. Dwek, R. Znamirowski, S. Statum, J. C. Hermida, D. D. D'Lima, R. L. Sah, J. Du, and C. B. Chung, "Ultrashort TEMRI of the osteochondral junction of the knee at 3 T: Identification of anatomic structures contributing to signal intensity in Proc. 17th Annu.Meeting ISMRM, Honolulu, HI, 2009, p. 78.
    • (2009) Proc. 17th Annu.Meeting ISMRM , pp. 78
    • Bae, W.C.1    Dwek, J.R.2    Znamirowski, R.3    Statum, S.4    Hermida, J.C.5    D'Lima, D.D.6    Sah, R.L.7    Du, J.8    Chung, C.B.9
  • 5
    • 84873316549 scopus 로고    scopus 로고
    • Variability of meniscal T2&z.ast; Calculations using ultra-short echo (UTE) imaging
    • Honolulu, HI
    • M. F. Koff, A. Takahashi, and H. Potter, Variability of meniscal T2&z.ast; calculations using ultra-short echo (UTE) imaging in Proc. 17th Annual Meeting ISMRM, Honolulu, HI, 2009, p. 289.
    • (2009) Proc. 17th Annual Meeting ISMRM , pp. 289
    • Koff, M.F.1    Takahashi, A.2    Potter, H.3
  • 8
    • 0027093023 scopus 로고
    • Projection reconstruction techniques for reduction of motion effects in MRI
    • DOI 10.1002/mrm.1910280209
    • G. H. Glover and J. H. Pauly, Projection reconstruction techniques for reduction of motion effects in MRI Magn. Reson. Med., vol. 28, pp. 275-289, Dec. 1992. (Pubitemid 23027667)
    • (1992) Magnetic Resonance in Medicine , vol.28 , Issue.2 , pp. 275-289
    • Glover, G.H.1    Pauly, J.M.2
  • 9
    • 0038621306 scopus 로고    scopus 로고
    • The use of measured k-space trajectory for reconstruction of radial MRI data
    • Honolulu, HI
    • B. M. Dale and J. L. Duerk, The use of measured k-space trajectory for reconstruction of radial MRI data in Proc. 10th Annu. Meeting ISMRM, Honolulu, HI, 2002, p. 2334.
    • (2002) Proc. 10th Annu. Meeting ISMRM , pp. 2334
    • Dale, B.M.1    Duerk, J.L.2
  • 10
    • 73149111748 scopus 로고    scopus 로고
    • Characterizing and correcting gradient errors in non-cartesian imaging: Are gradient errors linear time-invariant (LTI)?
    • Dec.
    • E. K. Brodsky, A. A. Samsonov, and W. F. Block, Characterizing and correcting gradient errors in non-cartesian imaging: Are gradient errors linear time-invariant (LTI)? Magn. Reson Med., vol. 62, pp. 1466-1476, Dec. 2009.
    • (2009) Magn. Reson Med. , vol.62 , pp. 1466-1476
    • Brodsky, E.K.1    Samsonov, A.A.2    Block, W.F.3
  • 11
    • 0037925300 scopus 로고    scopus 로고
    • Centering the projection reconstruction trajectory: Reducing gradient delay errors
    • DOI 10.1002/mrm.10501
    • D. C. Peters, J. A. Derbyshire, and E. R. McVeigh, Centering the projection reconstruction trajectory: Reducing gradient delay errors Magn. Reson. Med., vol. 50, pp. 1-6, July 2003. (Pubitemid 36841852)
    • (2003) Magnetic Resonance in Medicine , vol.50 , Issue.1 , pp. 1-6
    • Peters, D.C.1    Derbyshire, J.A.2    McVeigh, E.R.3
  • 12
    • 0034762213 scopus 로고    scopus 로고
    • Temperature mapping of frozen tissue using eddy current compensated half excitation RF pulses
    • DOI 10.1002/mrm.1285
    • J. P. Wansapura, B. L. Daniel, J. Pauly, and K. Butts, Temperature mapping of frozen tissue using eddy current compensated half excitation RF pulses Magn. Reson. Med., vol. 46, pp. 985-992, Nov. 2001. (Pubitemid 33019923)
    • (2001) Magnetic Resonance in Medicine , vol.46 , Issue.5 , pp. 985-992
    • Wansapura, J.P.1    Daniel, B.L.2    Pauly, J.3    Butts, K.4
  • 13
    • 0026219520 scopus 로고
    • Selection of a convolution function for Fourier inversion using gridding
    • Sep
    • J. I. Jackson, G. H. Meyer, and D. G. Nishimura, Selection of a convolution function for Fourier inversion using gridding IEEE Trans. Med. Imag., vol. 10, no. 3, pp. 473-478, Sep. 1991.
    • (1991) IEEE Trans. Med. Imag. , vol.10 , Issue.3 , pp. 473-478
    • Jackson, J.I.1    Meyer, G.H.2    Nishimura, D.G.3
  • 14
    • 84873319748 scopus 로고    scopus 로고
    • Anisotropic gradient time delay correction for oblique radial readouts used in ultrashort TE (UTE) imaging
    • Stockholm, Sweden
    • A. M. Takahashi, Anisotropic gradient time delay correction for oblique radial readouts used in ultrashort TE (UTE) imaging in Proc. 18th Annu. Meeting ISMRM, Stockholm, Sweden, 2010, p. 3101.
    • (2010) Proc. 18th Annu. Meeting ISMRM , pp. 3101
    • Takahashi, A.M.1
  • 16
    • 0032059889 scopus 로고    scopus 로고
    • Simple Correction Method for k-Space Trajectory Deviations in MRI
    • J. H. Duyn, Y. Yang, J. A. Frank, and J. W. Veen, Simple correction method for k-space trajectory deviations in MRI J. Magn. Reson., vol. 132, pp. 150-153, May 1998. (Pubitemid 128450598)
    • (1998) Journal of Magnetic Resonance , vol.132 , Issue.1 , pp. 150-153
    • Duyn, J.H.1    Yang, Y.2    Frank, J.A.3    Van Der Veen, J.W.4
  • 17
    • 67049114284 scopus 로고    scopus 로고
    • Estimation of k-space trajectory in spiral MRI
    • Jun
    • H. Tan and C. H. Meyer, Estimation of k-space trajectory in spiral MRI Magn. Reson Med., vol. 61, pp. 1396-1404, Jun. 2009.
    • (2009) Magn. Reson Med. , vol.61 , pp. 1396-1404
    • Tan, H.1    Meyer, C.H.2
  • 18
    • 84873282913 scopus 로고    scopus 로고
    • Compensation of eddy current by an R-L-C circuit model of the gradient system
    • Toronto, Canada
    • S. H. Cho, P. K. Kim, J. W. Lim, S. Y. Jeon, and C. B. Ahn, Compensation of eddy current by an R-L-C circuit model of the gradient system in Proc. 16th Annu. Meeting ISMRM, Toronto, Canada, 2008, p. 1156.
    • (2008) Proc. 16th Annu. Meeting ISMRM , pp. 1156
    • Cho, S.H.1    Kim, P.K.2    Lim, J.W.3    Jeon, S.Y.4    Ahn, C.B.5
  • 19
    • 77952715712 scopus 로고    scopus 로고
    • Fast, simple gradient delay estimation for spiral MRI
    • Jun
    • R. K. Robison, A. Devaraj, and J. G. Pipe, Fast, simple gradient delay estimation for spiral MRI Magn. Reson. Med., vol. 63, pp. 1683-1690, Jun. 2010.
    • (2010) Magn. Reson. Med. , vol.63 , pp. 1683-1690
    • Robison, R.K.1    Devaraj, A.2    Pipe, J.G.3
  • 20
    • 84887843019 scopus 로고    scopus 로고
    • Robust correction algorithm for radial sampling on open MRI system
    • Sedona, AZ
    • M. Takizawa and T. Takahashi, Robust correction algorithm for radial sampling on open MRI system in Proc. ISMRM Workshop Non-Cartesian MR, Sedona, AZ, 2007, p. 3.
    • (2007) Proc. ISMRM Workshop Non-Cartesian MR , pp. 3
    • Takizawa, M.1    Takahashi, T.2
  • 22
    • 35448964383 scopus 로고    scopus 로고
    • Simple phase method for measurement of magnetic field gradient waveforms
    • DOI 10.1016/j.mri.2007.02.002, PII S0730725X07001397
    • P. Latta, M. L. H. Gruwel, V. Volotovsky, M. H. Weber, and B. Tomanek, Simple phase method for measurement of magnetic field gradient waveforms Magn. Reson. Imag., vol. 25, pp. 1272-1276, Nov. 2007. (Pubitemid 47625917)
    • (2007) Magnetic Resonance Imaging , vol.25 , Issue.9 , pp. 1272-1276
    • Latta, P.1    Gruwel, M.L.H.2    Volotovskyy, V.3    Weber, M.H.4    Tomanek, B.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.