The management of imaging dose during image-guided radiotherapy: Report of the AAPM Task Group 75
M.J. Murphy, J. Balter, and S. Balter The management of imaging dose during image-guided radiotherapy: report of the AAPM Task Group 75 Med Phys 34 2007 4041 4063
A phantom evaluation of a stereo-vision surface imaging system for radiotherapy patient setup
C. Bert, K.G. Metheany, and K. Doppke A phantom evaluation of a stereo-vision surface imaging system for radiotherapy patient setup Med Phys 32 2005 2753 2762
Clinical experience with a 3D surface patient setup system for alignment of partial-breast irradiation patients
C. Bert, K.G. Metheany, and K.P. Doppke Clinical experience with a 3D surface patient setup system for alignment of partial-breast irradiation patients Int J Radiat Oncol Biol Phys 64 2006 1265 1274
Technical performance of a commercial laser surface scanning system for patient setup correction in radiotherapy
T. Moser, S. Fleischhacker, and K. Schubert Technical performance of a commercial laser surface scanning system for patient setup correction in radiotherapy Phys Med 27 2011 224 232
Accuracy of a commercial optical 3D surface imaging system for realignment of patients for radiotherapy of the thorax
P.J. Schöffel, W. Harms, and G. Sroka-Perez Accuracy of a commercial optical 3D surface imaging system for realignment of patients for radiotherapy of the thorax Phys Med Biol 52 2007 3949 3963
Real-time opto-electronic verification of patient position in breast cancer radiotherapy
G. Baroni, G. Ferrigno, and R. Orecchia Real-time opto-electronic verification of patient position in breast cancer radiotherapy Comput Aided Surg 5 2000 296 306
Evaluation of methods for opto-electronic body surface sensing applied to patient position control in breast radiation therapy
G. Baroni, A. Troia, and M. Riboldi Evaluation of methods for opto-electronic body surface sensing applied to patient position control in breast radiation therapy Med Biol Eng Comput 41 2003 679 688
Comparison of target registration errors for multiple image-guided techniques in accelerated partial breast irradiation
D.P. Gierga, M. Riboldi, and J.C. Turcotte Comparison of target registration errors for multiple image-guided techniques in accelerated partial breast irradiation Int J Radiat Oncol Biol Phys 70 2008 1239 1246
Reproducibility of patient setup by surface image registration system in conformal radiotherapy of prostate cancer
M. Krengli, S. Gaiano, and E. Mones Reproducibility of patient setup by surface image registration system in conformal radiotherapy of prostate cancer Radiat Oncol 4 2009 9
Detection of setup uncertainties with 3D surface registration system for conformal radiotherapy of breast cancer
L. Deantonio, L. Masini, and G. Loi Detection of setup uncertainties with 3D surface registration system for conformal radiotherapy of breast cancer Rep Pract Oncol Radiother 16 2011 77 81
A comprehensive assessment by tumor site of patient setup using daily MVCT imaging from more than 3,800 helical tomotherapy treatments
L.K. Schubert, D.C. Westerly, and W.A. Tome A comprehensive assessment by tumor site of patient setup using daily MVCT imaging from more than 3,800 helical tomotherapy treatments Int J Radiat Oncol Biol Phys 73 2009 1260 1269
A phantom evaluation of Sentinel, a commercial laser/camera surface imaging system for patient setup verification in radiotherapy
S. Pallotta, L. Marrazzo, and M. Ceroti A phantom evaluation of Sentinel, a commercial laser/camera surface imaging system for patient setup verification in radiotherapy Med Phys 39 2012 706 712