메뉴 건너뛰기




Volumn 17, Issue 12, 2012, Pages

Three-dimensional imaging of normal skin and nonmelanoma skin cancer with cellular resolution using Gabor domain optical coherence microscopy

Author keywords

Biomedical optics; Imaging coherence; Imaging systems; Medical imaging

Indexed keywords

BIOMEDICAL OPTICS; CELLULAR RESOLUTION; GABOR DOMAINS; NONMELANOMA SKIN; OPTICAL COHERENCE MICROSCOPY; THREE DIMENSIONAL IMAGING; THREEDIMENSIONAL (3-D); VOLUMETRIC IMAGES;

EID: 84873276517     PISSN: 10833668     EISSN: 15602281     Source Type: Journal    
DOI: 10.1117/1.JBO.17.12.126006     Document Type: Article
Times cited : (53)

References (45)
  • 1
    • 17144475375 scopus 로고    scopus 로고
    • Basal cell carcinoma of the eyelids
    • J. Allali, F. D'Hermies, and G. Renard, "Basal cell carcinoma of the eyelids," Ophthalmologica 219(2), 57-71 (2005).
    • (2005) Ophthalmologica , vol.219 , Issue.2 , pp. 57-71
    • Allali, J.1    D'hermies, F.2    Renard, G.3
  • 3
    • 77949405816 scopus 로고    scopus 로고
    • Incidence estimate of nonmelanoma skin cancer in the United States, 2006
    • H.W. Rogers et al., "Incidence estimate of nonmelanoma skin cancer in the United States, 2006," Arch. Dermatol. 146(3), 283-287 (2010).
    • (2010) Arch. Dermatol. , vol.146 , Issue.3 , pp. 283-287
    • Rogers, H.W.1
  • 4
    • 0346458726 scopus 로고    scopus 로고
    • Optical coherence tomography versus ultrasound microscopy of conjunctival and eyelid lesions
    • H. J. Buchwald et al., "Optical coherence tomography versus ultrasound microscopy of conjunctival and eyelid lesions," Klin. Monatsbl. Augenheilk 220(12), 822-829 (2003).
    • (2003) Klin. Monatsbl. Augenheilk , vol.220 , Issue.12 , pp. 822-829
    • Buchwald, H.J.1
  • 5
    • 34247862209 scopus 로고    scopus 로고
    • High-resolution MRI of basal cell carcinomas of the face using a microscopy coil
    • H. Gufler, F. E. Franke, and W. S. Rau, "High-resolution MRI of basal cell carcinomas of the face using a microscopy coil," Am. J. Roentgenol 188(5), 480-484 (2007).
    • (2007) Am. J. Roentgenol , vol.188 , Issue.5 , pp. 480-484
    • Gufler, H.1    Franke, F.E.2    Rau, W.S.3
  • 6
    • 0032870590 scopus 로고    scopus 로고
    • In vivo confocal scanning laser microscopy of human skin II: Advances in instrumentation and comparison with histology
    • DOI 10.1046/j.1523-1747.1999.00690.x
    • M. Rajadhyaksha et al., "In vivo confocal laser microscopy of human skin II: advances in instrumentation and comparison with histology," J. Invest. Dermatol. 113(3), 293-303 (1999). (Pubitemid 29449064)
    • (1999) Journal of Investigative Dermatology , vol.113 , Issue.3 , pp. 293-303
    • Rajadhyaksha, M.1    Gonzalez, S.2    Zavislan, J.M.3    Anderson, R.R.4    Webb, R.H.5
  • 7
    • 0030927012 scopus 로고    scopus 로고
    • Multiphoton excitation fluorescence microscopy and spectroscopy of in vivo human skin
    • B. R. Masters, P. T. C. So, and E. Gratton, "Multiphoton excitation fluorescence microscopy and spectroscopy of in-vivo human skin," Biophys. J. 72(6), 2405-2412 (1997). (Pubitemid 27227578)
    • (1997) Biophysical Journal , vol.72 , Issue.6 , pp. 2405-2412
    • Masters, B.R.1    So, P.T.C.2    Gratton, E.3
  • 10
    • 0035188381 scopus 로고    scopus 로고
    • Optical coherence tomography in dermatology: A review
    • DOI 10.1034/j.1600-0846.2001.007001001.x
    • J. Welzel et al., "Optical coherence tomography in dermatology: a review," Skin Res. Technol. 7(1), 1-9 (2001). (Pubitemid 32060993)
    • (2001) Skin Research and Technology , vol.7 , Issue.1 , pp. 1-9
    • Welzel, J.1
  • 14
    • 77956642733 scopus 로고    scopus 로고
    • Multispectral in vivo three-dimensional optical coherence tomography of human skin
    • A. Alex et al., "Multispectral in vivo three-dimensional optical coherence tomography of human skin," J. Biomed. Opt. 15(2), 026025 (2010).
    • (2010) J. Biomed. Opt. , vol.15 , Issue.2 , pp. 026025
    • Alex, A.1
  • 17
    • 33746887804 scopus 로고    scopus 로고
    • Optical coherence tomography for the characterization of basal cell carcinoma in vivo: A pilot study
    • DOI 10.1016/j.jaad.2006.03.013, PII S0190962206008036
    • J. Olmedo, K. Warschaw, and J. Schmitt, "Optical coherence tomography for the characterization of basal cell carcinoma in vivo: a pilot study," J. Am. Acad. Dermatol. 55(3), 408-412 (2006). (Pubitemid 44189581)
    • (2006) Journal of the American Academy of Dermatology , vol.55 , Issue.3 , pp. 408-412
    • Olmedo, J.M.1    Warschaw, K.E.2    Schmitt, J.M.3    Swanson, D.L.4
  • 18
    • 34147176057 scopus 로고    scopus 로고
    • Correlation of thickness of basal cell carcinoma by optical coherence tomography in vivo and routine histologic findings: A pilot study
    • DOI 10.1111/j.1524-4725.2007.33088.x
    • J. M. Olmedo et al., "Correlation of thickness of basal cell carcinoma by optical coherence tomography in vivo and routine histologic findings: a pilot study," Dermatol. Surg. 33(4), 421-425 (2007). (Pubitemid 46570112)
    • (2007) Dermatologic Surgery , vol.33 , Issue.4 , pp. 421-425
    • Olmedo, J.M.1    Warschaw, K.E.2    Schmitt, J.M.3    Swanson, D.L.4
  • 21
    • 33645459019 scopus 로고    scopus 로고
    • Noninvasive imaging of oral premalignancy and malignancy
    • P.Wilder-Smith et al., "Noninvasive imaging of oral premalignancy and malignancy," J. Biomed. Opt. 10(5), 051601 (2005).
    • (2005) J. Biomed. Opt. , vol.10 , Issue.5 , pp. 051601
    • Wilder-Smith, P.1
  • 23
    • 84859577484 scopus 로고    scopus 로고
    • Preoperative characterization of basal cell carcinoma comparing tumour thickness measurement by optical coherence tomography 20-MHz ultrasound and histopathology
    • T. Hinz et al., "Preoperative characterization of basal cell carcinoma comparing tumour thickness measurement by optical coherence tomography 20-MHz ultrasound and histopathology," Acta Derm. Venereol. 92(3), 132-137 (2012).
    • (2012) Acta Derm. Venereol. , vol.92 , Issue.3 , pp. 132-137
    • Hinz, T.1
  • 24
    • 84855261735 scopus 로고    scopus 로고
    • Optical coherence tomography used as a modality to delineate basal cell carcinoma prior to Mohs micrographic surgery
    • R. Ponerantz et al., "Optical coherence tomography used as a modality to delineate basal cell carcinoma prior to Mohs micrographic surgery," Case Rep. Dermatol. 3(3), 212-218 (2011).
    • (2011) Case Rep. Dermatol. , vol.3 , Issue.3 , pp. 212-218
    • Ponerantz, R.1
  • 25
    • 70349334195 scopus 로고    scopus 로고
    • OCT imaging of skin cancer and other dermatological diseases
    • M. Mogensen et al., "OCT imaging of skin cancer and other dermatological diseases," J. Biophotonics 2(6-7), 442-451 (2009).
    • (2009) J. Biophotonics , vol.2 , Issue.6-7 , pp. 442-451
    • Mogensen, M.1
  • 26
    • 66449105802 scopus 로고    scopus 로고
    • Assessment of optical coherence tomography imaging in the diagnosis of non-melanoma skin cancer and benign lesions versus normal skin: Observer-blinded evaluation by dermatologists and pathologists
    • M. Mogensen et al., "Assessment of optical coherence tomography imaging in the diagnosis of non-melanoma skin cancer and benign lesions versus normal skin: observer-blinded evaluation by dermatologists and pathologists," Dermatol. Surg. 35(6), 965-972 (2009).
    • (2009) Dermatol. Surg. , vol.35 , Issue.6 , pp. 965-972
    • Mogensen, M.1
  • 27
    • 0242333241 scopus 로고    scopus 로고
    • High-resolution optical coherence microscopy for high-speed, in vivo cellular imaging
    • A. Aguirre et al., "High-resolution optical coherence microscopy for high-speed, in vivo cellular imaging," Opt. Lett. 28(21), 2064-2066 (2003).
    • (2003) Opt. Lett. , vol.28 , Issue.21 , pp. 2064-2066
    • Aguirre, A.1
  • 29
    • 37549069659 scopus 로고    scopus 로고
    • In vivo video-rate cellular-level full-field optical coherence tomography
    • M. Akiba and K. Chan, "In vivo video-rate cellular-level full-field optical coherence tomography," J. Biomed. Opt. 12(6), 064024 (2007).
    • (2007) J. Biomed. Opt. , vol.12 , Issue.6 , pp. 064024
    • Akiba, M.1    Chan, K.2
  • 30
    • 0000204268 scopus 로고    scopus 로고
    • Phase-resolved optical coherence tomography and optical Doppler tomography for imaging blood flow in human skin with fast scanning speed and high velocity sensitivity
    • Y. Zhao et al., "Phase-resolved optical coherence tomography and optical Doppler tomography for imaging blood flow in human skin with fast scanning speed and high velocity sensitivity," Opt. Lett. 25(2), 114-116 (2000).
    • (2000) Opt. Lett. , vol.25 , Issue.2 , pp. 114-116
    • Zhao, Y.1
  • 31
    • 33751319919 scopus 로고    scopus 로고
    • Doppler optical coherence tomography to monitor the effect of photodynamic therapy on tissue morphology and perfusion
    • M. C. Aalders et al., "Doppler optical coherence tomography to monitor the effect of photodynamic therapy on tissue morphology and perfusion," J. Biomed. Opt. 11(4), 044011 (2006).
    • (2006) J. Biomed. Opt. , vol.11 , Issue.4 , pp. 044011
    • Aalders, M.C.1
  • 32
    • 2442646774 scopus 로고    scopus 로고
    • Polarization-sensitive optical coherence tomography of invasive basal cell carcinoma
    • J. Strasswimmer et al., "Polarization-sensitive optical coherence tomography of invasive basal cell carcinoma," J. Biomed. Opt. 9(2), 292-298 (2004).
    • (2004) J. Biomed. Opt. , vol.9 , Issue.2 , pp. 292-298
    • Strasswimmer, J.1
  • 33
    • 79953219115 scopus 로고    scopus 로고
    • In vivo three-dimensional optical coherence elastography
    • B. F. Kennedy et al., "In vivo three-dimensional optical coherence elastography," Opt. Express 19(7), 6623-6634 (2011).
    • (2011) Opt. Express , vol.19 , Issue.7 , pp. 6623-6634
    • Kennedy, B.F.1
  • 34
    • 70349324220 scopus 로고    scopus 로고
    • Clinical optical coherence tomography combined with multiphoton tomography of patients with skin diseases
    • K. Konig et al., "Clinical optical coherence tomography combined with multiphoton tomography of patients with skin diseases," J. Biophotonics 2(6-7), 389-397 (2009).
    • (2009) J. Biophotonics , vol.2 , Issue.6-7 , pp. 389-397
    • Konig, K.1
  • 35
    • 82255174692 scopus 로고    scopus 로고
    • Multimodal photoacoustic and optical coherence tomography scanner using an all optical detection scheme for 3-D morphological skin imaging
    • E. Z. Zhang et al., "Multimodal photoacoustic and optical coherence tomography scanner using an all optical detection scheme for 3-D morphological skin imaging," Biomed. Opt. Express 2(8), 2202-2215 (2011).
    • (2011) Biomed. Opt. Express , vol.2 , Issue.8 , pp. 2202-2215
    • Zhang, E.Z.1
  • 36
    • 79959476269 scopus 로고    scopus 로고
    • Micron-class resolution optical coherence microscopy with high acquisition speed for in vivo human skin cell imaging
    • K. Lee et al., "Micron-class resolution optical coherence microscopy with high acquisition speed for in vivo human skin cell imaging," Opt. Lett. 36(12), 2221-2223 (2011).
    • (2011) Opt. Lett. , vol.36 , Issue.12 , pp. 2221-2223
    • Lee, K.1
  • 37
    • 77149153385 scopus 로고    scopus 로고
    • Gabor-based fusion technique for optical coherence microscopy
    • J. P. Rolland et al., "Gabor-based fusion technique for optical coherence microscopy," Opt. Express 18(4), 3632-3642 (2010).
    • (2010) Opt. Express , vol.18 , Issue.4 , pp. 3632-3642
    • Roll, J.P.1
  • 38
    • 58349094940 scopus 로고    scopus 로고
    • Three-dimensional adaptive microscopy using embedded liquid lens
    • S. Murali et al., "Three-dimensional adaptive microscopy using embedded liquid lens," Opt. Lett. 34(2), 145-147 (2009).
    • (2009) Opt. Lett. , vol.34 , Issue.2 , pp. 145-147
    • Murali, S.1
  • 39
    • 22144453873 scopus 로고    scopus 로고
    • Dispersion control with a Fourier-domain optical delay line in a fiber-optic imaging interferometer
    • DOI 10.1364/AO.44.004009
    • K. Lee et al., "Dispersion control with Fourier-domain optical delay line in a fiber optic imaging interferometer," Appl. Opt. 44(19), 4009-4022 (2005). (Pubitemid 40971994)
    • (2005) Applied Optics , vol.44 , Issue.19 , pp. 4009-4022
    • Lee, K.-S.1    Ceyhun Akcay, A.2    Delemos, T.3    Clarkson, E.4    Rolland, J.P.5
  • 40
    • 78149371241 scopus 로고    scopus 로고
    • Broadband astigmatism correction Czerny-Turner spectrometer
    • K. Lee et al., "Broadband astigmatism correction Czerny-Turner spectrometer," Opt. Express 18(22), 23378-23384 (2010).
    • (2010) Opt. Express , vol.18 , Issue.22 , pp. 23378-23384
    • Lee, K.1
  • 41
    • 77951734083 scopus 로고    scopus 로고
    • Assessment of a liquid lens enabled in vivo optical coherence microscope
    • S. Murali et al., "Assessment of a liquid lens enabled in vivo optical coherence microscope," Appl. Opt. 49(16), D145-D156 (2010).
    • (2010) Appl. Opt. , vol.49 , Issue.16
    • Murali, S.1
  • 42
    • 33644676530 scopus 로고    scopus 로고
    • Refractive indices of human skin tissues at eight wavelengths and estimated dispersion relations between 300 and 1600 nm
    • DOI 10.1088/0031-9155/51/6/008, PII S0031915506076925
    • H. Ding et al., "Refractive indeces of human skin tissues at eight wavelengths and estimated dispersion relations between 300 and 1600 nm," Phys. Med. Biol. 51(6), 1479-1489 (2006). (Pubitemid 43332349)
    • (2006) Physics in Medicine and Biology , vol.51 , Issue.6 , pp. 1479-1489
    • Ding, H.1    Lu, J.Q.2    Wooden, W.A.3    Kragel, P.J.4    Hu, X.-H.5
  • 43
    • 33751172945 scopus 로고    scopus 로고
    • In vivo data of epidermal thickness evaluated by optical coherence tomography: Effects of age, gender, skin type, and anatomic site
    • T. Gambichler et al., "In vivo data of epidermal thickness evaluated by optical coherence tomography: effects of age, gender, skin type, and anatomic site," J. Dermatol. Sci. 44(3), 145-152 (2006).
    • (2006) J. Dermatol. Sci. , vol.44 , Issue.3 , pp. 145-152
    • Gambichler, T.1
  • 45
    • 33645295820 scopus 로고    scopus 로고
    • Modelling cancer in human skin tissue
    • P. A. Khavari, "Modelling cancer in human skin tissue," Nat. Rev. Cancer 6(4), 270-280 (2006).
    • (2006) Nat. Rev. Cancer , vol.6 , Issue.4 , pp. 270-280
    • Khavari, P.A.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.