메뉴 건너뛰기




Volumn 134, Issue 12, 2012, Pages

Biomechanical measurements of surgical drilling force and torque in human versus artificial femurs

Author keywords

artificial femur; force; human femur; surgical drilling; torque

Indexed keywords

ARTIFICIAL BONES; ARTIFICIAL FEMUR; BIOMECHANICAL MEASUREMENT; BIOMECHANICAL STUDIES; BONE MINERAL DENSITY; BONE QUALITY; CNC MACHINE; EXPERIMENTAL STUDIES; FEED-RATES; FORCE; HUMAN BONES; HUMAN CORTICAL BONE; HUMAN FEMORA; HUMAN FEMUR; HUMAN SPECIMENS; LONG BONE; SPEED EFFECT; SPINDLE SPEED; STATISTICAL SIGNIFICANCE; SURGICAL DRILLING; THRUST FORCE AND TORQUE;

EID: 84873174465     PISSN: 01480731     EISSN: 15288951     Source Type: Journal    
DOI: 10.1115/1.4007953     Document Type: Article
Times cited : (43)

References (80)
  • 3
    • 0017403348 scopus 로고
    • Age and sex related changes in the structure and strength of the human femoral shaft
    • Martin, R. B., and Atkinson, P. J., 1977, "Age and Sex-Related Changes in the Structure and Strength of the Human Femoral Shaft," J. Biomech., 10, pp. 223-231. (Pubitemid 8100017)
    • (1977) Journal of Biomechanics , vol.10 , Issue.4 , pp. 223-231
    • Martin, R.B.1    Atkinson, P.J.2
  • 6
    • 78650832158 scopus 로고    scopus 로고
    • A biomechanical comparison of two triple-screw methods for femoral neck fracture fixation in a synthetic bone model
    • Zdero, R., Keast-Butler, O., and Schemitsch, E. H., 2010, "A Biomechanical Comparison of Two Triple-Screw Methods for Femoral Neck Fracture Fixation in a Synthetic Bone Model," J. Trauma, 69(6), pp. 1537-1544.
    • (2010) J. Trauma , vol.69 , Issue.6 , pp. 1537-1544
    • Zdero, R.1    Keast-Butler, O.2    Schemitsch, E.H.3
  • 8
    • 0033093073 scopus 로고    scopus 로고
    • Internal fixation of femoral neck fractures with posterior comminution: A biomechanical study
    • Kauffman, J. I., Simon, J. A., Kummer, F. J., Pearlman, C. J., Zuckerman, J. D., and Koval, K. J., 1999, "Internal Fixation of Femoral Neck Fractures With Posterior Comminution: A Biomechanical Study," J. Orthop. Trauma, 13, pp. 155-159.
    • (1999) J. Orthop. Trauma , vol.13 , pp. 155-159
    • Kauffman, J.I.1    Simon, J.A.2    Kummer, F.J.3    Pearlman, C.J.4    Zuckerman, J.D.5    Koval, K.J.6
  • 9
    • 0027943425 scopus 로고
    • Basicervical fractures of the proximal femur: A biomechanical study of 3 internal fixation techniques
    • Blair, B., Koval, K. J., Kummer, F., and Zuckerman, J. D., 1994, "Basicervical Fractures of the Proximal Femur: A Biomechanical Study of 3 Internal Fixation Techniques," Clin. Orthop. Relat. Res., 306, pp. 256-263. (Pubitemid 24324962)
    • (1994) Clinical Orthopaedics and Related Research , Issue.306 , pp. 256-263
    • Blair, B.1    Koval, K.J.2    Kummer, F.3    Zuckerman, J.D.4
  • 10
    • 34548455937 scopus 로고    scopus 로고
    • Vertically oriented femoral neck fractures: Mechanical analysis of four fixation techniques
    • DOI 10.1097/BOT.0b013e31814b822e, PII 0000513120070900000005
    • Aminian, A., Gao, F., Fedoriw, W. W., Zhang, L. Q., Kalainov, D. M., and Merk, B. R., 2007, "Vertically Oriented Femoral Neck Fractures: Mechanical Analysis of Four Fixation Techniques," J. Orthop. Trauma, 21, pp. 544-548. (Pubitemid 47367962)
    • (2007) Journal of Orthopaedic Trauma , vol.21 , Issue.8 , pp. 544-548
    • Aminian, A.1    Gao, F.2    Fedoriw, W.W.3    Zhang, L.-Q.4    Kalainov, D.M.5    Merk, B.R.6
  • 12
    • 0026341525 scopus 로고
    • Internal fixation of femoral neck fractures: A comparative biomechanical study of knowles pins and 6.5-mm cancellous screws
    • Springer, E. R., Lachiewicz, P. F., and Gilbert, J. A., 1991, "Internal Fixation of Femoral Neck Fractures: A Comparative Biomechanical Study of Knowles Pins and 6.5-mm Cancellous Screws," Clin. Orthop. Relat. Res., 267, pp. 85-92.
    • (1991) Clin. Orthop. Relat. Res , vol.267 , pp. 85-92
    • Springer, E.R.1    Lachiewicz, P.F.2    Gilbert, J.A.3
  • 14
    • 80051848718 scopus 로고    scopus 로고
    • The biomechanics of plate fixation of periprosthetic femoral fractures near the tip of a total hip implant: Cables, screws, or both?
    • Shah, S., Kim, S. Y. R., Dubov, A., Schemitsch, E. H., Bougherara, H., and Zdero, R., 2011, "The Biomechanics of Plate Fixation of Periprosthetic Femoral Fractures Near the Tip of a Total Hip Implant: Cables, Screws, or Both?," Proc. Inst. Mech. Eng., Part H: J. Eng. Med., 225(9), pp. 845-856.
    • (2011) Proc. Inst. Mech. Eng., Part H: J. Eng. Med , vol.225 , Issue.9 , pp. 845-856
    • Shah, S.1    Kim, S.Y.R.2    Dubov, A.3    Schemitsch, E.H.4    Bougherara, H.5    Zdero, R.6
  • 15
    • 80051856327 scopus 로고    scopus 로고
    • The biomechanics of plate repair of periprosthetic femur fractures near the tip of a total hip implant: The effect of cable-screw position
    • Dubov. A., Kim, S. Y. R., Shah, S., Schemitsch, E. H., Zdero, R., and Bougherara, H., 2011, "The Biomechanics of Plate Repair of Periprosthetic Femur Fractures Near the Tip of a Total Hip Implant: The Effect of Cable-Screw Position," Proc. Inst. Mech. Eng., Part H: J. Eng. Med., 225(9), pp. 857-865.
    • (2011) Proc. Inst. Mech. Eng., Part H: J. Eng. Med , vol.225 , Issue.9 , pp. 857-865
    • Dubov, A.1    Kim, S.Y.R.2    Shah, S.3    Schemitsch, E.H.4    Zdero, R.5    Bougherara, H.6
  • 17
    • 38749090538 scopus 로고    scopus 로고
    • Fixation of long bone segmental defects: A biomechanical study
    • Talbot, M., Zdero, R., Garneau, D., Cole, P. A., and Schemitsch, E. H., 2007, "Fixation of Long Bone Segmental Defects: A Biomechanical Study," Injury, 39, pp. 181-186.
    • (2007) Injury , vol.39 , pp. 181-186
    • Talbot, M.1    Zdero, R.2    Garneau, D.3    Cole, P.A.4    Schemitsch, E.H.5
  • 18
    • 77954774700 scopus 로고    scopus 로고
    • The biomechanical analysis of three plating fixation systems for periprosthetic femoral fracture near the tip of a total hip arthroplasty
    • Lever, J. P., Zdero, R., Nousiainen, M. T., Waddell, J. P., and Schemitsch, E. H., 2010, "The Biomechanical Analysis of Three Plating Fixation Systems for Periprosthetic Femoral Fracture Near the Tip of a Total Hip Arthroplasty," J. Orthop. Surg. Res., 5:45.
    • (2010) J. Orthop. Surg. Res , vol.5 , pp. 45
    • Lever, J.P.1    Zdero, R.2    Nousiainen, M.T.3    Waddell, J.P.4    Schemitsch, E.H.5
  • 20
    • 56149107509 scopus 로고    scopus 로고
    • The biomechanics of ipsilateral intertrochanteric and femoral shaft fractures: A comparison of 5 fracture fixation techniques
    • McConnell, A., Zdero, R., Syed, K., Peskun, C., and Schemitsch, E. H., 2008, "The Biomechanics of Ipsilateral Intertrochanteric and Femoral Shaft Fractures: A Comparison of 5 Fracture Fixation Techniques," J. Orthop. Trauma, 22(8), pp. 517-524.
    • (2008) J. Orthop. Trauma , vol.22 , Issue.8 , pp. 517-524
    • McConnell, A.1    Zdero, R.2    Syed, K.3    Peskun, C.4    Schemitsch, E.H.5
  • 22
    • 0348140582 scopus 로고    scopus 로고
    • Finite element analysis of a femoral retrograde intramedullary nail subject to gait loading
    • DOI 10.1016/j.medengphy.2003.10.006
    • Cheung, G., Zalzal, P., Bhandari, M., Spelt, J. K., and Papini, M., 2004, "Finite Element Analysis of a Femoral Retrograde Intramedullary Nail Subject to Gait Loading," Med. Eng. Phys., 26(2), pp. 93-108. (Pubitemid 38022001)
    • (2004) Medical Engineering and Physics , vol.26 , Issue.2 , pp. 93-108
    • Cheung, G.1    Zalzal, P.2    Bhandari, M.3    Spelt, J.K.4    Papini, M.5
  • 23
    • 84860581951 scopus 로고    scopus 로고
    • A biomechanical comparison of static versus dynamic lag screw modes for cephalomedullary nails used to fix unstable peritrochanteric fractures
    • Kuzyk, P. R. T., Shah, S., Zdero, R., Olsen, M., Waddell, J. P., and Schemitsch, E. H., 2012, "A Biomechanical Comparison of Static Versus Dynamic Lag Screw Modes for Cephalomedullary Nails Used to Fix Unstable Peritrochanteric Fractures," J. Trauma Acute Care Surg., 72(2), E65-E70.
    • (2012) J. Trauma Acute Care Surg , vol.72 , Issue.2
    • Kuzyk, P.R.T.1    Shah, S.2    Zdero, R.3    Olsen, M.4    Waddell, J.P.5    Schemitsch, E.H.6
  • 24
    • 84863496621 scopus 로고    scopus 로고
    • Femoral head lag screw position for cephalomedullary nails: A biomechanical analysis
    • Kuzyk, P. R. T., Zdero, R., Shah, S., Olsen, M., Waddell, J. P., and Schemitsch, E. H., 2012, "Femoral Head Lag Screw Position for Cephalomedullary Nails: A Biomechanical Analysis," J. Orthop. Trauma, 26(7), pp. 414-421.
    • (2012) J. Orthop. Trauma , vol.26 , Issue.7 , pp. 414-421
    • Kuzyk, P.R.T.1    Zdero, R.2    Shah, S.3    Olsen, M.4    Waddell, J.P.5    Schemitsch, E.H.6
  • 25
    • 0017115122 scopus 로고
    • Drilling of bone
    • Wiggins, K. L., and Malkin, S., 1976, "Drilling of Bone," J. Biomech., 9(9), pp. 553-559.
    • (1976) J. Biomech , vol.9 , Issue.9 , pp. 553-559
    • Wiggins, K.L.1    Malkin, S.2
  • 28
    • 0031380318 scopus 로고    scopus 로고
    • A hand-held drilling tool for orthopedic surgery
    • PII S1083443597090261
    • Allotta, B., Giacalone, G., and Rinaldi, L., 1997, "A Hand-Held Drilling Tool for Orthopedic Surgery," IEEE/ASME Trans. Mechatron., 2(4), pp. 218-229. (Pubitemid 127772341)
    • (1997) IEEE/ASME Transactions on Mechatronics , vol.2 , Issue.4 , pp. 218-229
    • Allotta, B.1    Giacalone, G.2    Rinaldi, L.3
  • 29
    • 0033654180 scopus 로고    scopus 로고
    • Evaluation of bone strength: Correlation between measurements of bone mineral density and drilling force
    • Ong, F. R., and Bouazza-Marouf, K., 2000, "Evaluation of Bone Strength: Correlation Between Measurements of Bone Mineral Density and Drilling Force," Proc. Inst. Mech. Eng., Part H: J. Eng. Med., 214, pp. 385-399.
    • (2000) Proc. Inst. Mech. Eng., Part H: J. Eng. Med , vol.214 , pp. 385-399
    • Ong, F.R.1    Bouazza-Marouf, K.2
  • 30
    • 0017101144 scopus 로고
    • A study of the bone machining process-drilling
    • Jacob, C. H., Berry, J. T., Pope, M. H., and Hoaglund, F. T., 1976, "A Study of the Bone Machining Process-Drilling," J. Biomech., 9(5), pp. 343-349.
    • (1976) J. Biomech , vol.9 , Issue.5 , pp. 343-349
    • Jacob, C.H.1    Berry, J.T.2    Pope, M.H.3    Hoaglund, F.T.4
  • 31
    • 0017642925 scopus 로고
    • Investigation of variable factors in drilling bone
    • Hobkirk, J. A., and Rusiniak, K., 1977, "Investigation of Variable Factors in Drilling Bone," J. Oral Surg., 35, pp. 968-973. (Pubitemid 8242795)
    • (1977) Journal of Oral Surgery , vol.35 , Issue.12 , pp. 968-973
    • Hobkirk, J.A.1    Rusiniak, K.2
  • 32
    • 79951775233 scopus 로고    scopus 로고
    • Experimental investigations of forces and torque in conventional and ultrasonically-assisted drilling of cortical bone
    • Alam, K., Mitrofanov, A. V., and Silberschmidt, V. V., 2011, "Experimental Investigations of Forces and Torque in Conventional and Ultrasonically-Assisted Drilling of Cortical Bone," Med. Eng. Phys., 33, pp. 234-239.
    • (2011) Med. Eng. Phys , vol.33 , pp. 234-239
    • Alam, K.1    Mitrofanov, A.V.2    Silberschmidt, V.V.3
  • 33
    • 0020000033 scopus 로고
    • Research on the mechanical impedance of human bone by a drilling test
    • DOI 10.1016/0021-9290(82)90069-0
    • Karalis, T., and Galanos, P., 1982, "Research on the Mechanical Impedance Of Human Bone by a Drilling Test," J. Biomech., 15, pp. 561-581. (Pubitemid 12009862)
    • (1982) Journal of Biomechanics , vol.15 , Issue.8 , pp. 561-581
    • Karalis, T.1    Galanos, P.2
  • 34
    • 69249202476 scopus 로고    scopus 로고
    • Finite element analysis of forces of plane cutting of cortical bone
    • Alam, K., Mitrofanov, A. V., and Silberschmidt, V. V., 2009, "Finite Element Analysis of Forces of Plane Cutting of Cortical Bone," Comput. Mater. Sci., 46, pp. 738-743.
    • (2009) Comput. Mater. Sci , vol.46 , pp. 738-743
    • Alam, K.1    Mitrofanov, A.V.2    Silberschmidt, V.V.3
  • 35
    • 0343168054 scopus 로고    scopus 로고
    • Temperature effects in the drilling of human and bovine bone
    • DOI 10.1016/S0924-0136(99)00155-7
    • Hillery, M. T., and Shuaib, I., 1999, "Temperature Effects in the Drilling of Human and Bovine Bone," J. Mater. Process. Technol., 92-93, pp. 302-308. (Pubitemid 30535040)
    • (1999) Journal of Materials Processing Technology , vol.92-93 , pp. 302-308
    • Hillery, M.T.1    Shuaib, I.2
  • 36
    • 84862801985 scopus 로고    scopus 로고
    • Modeling and experimentation of bone drilling forces
    • Lee, J., Gozen, B. A., and Ozdoganlar, O. B., 2012, "Modeling and Experimentation of Bone Drilling Forces," J. Biomech., 45, pp. 1076-1083.
    • (2012) J. Biomech , vol.45 , pp. 1076-1083
    • Lee, J.1    Gozen, B.A.2    Ozdoganlar, O.B.3
  • 37
    • 0029890494 scopus 로고    scopus 로고
    • Orthopaedic bone drills: Can they be improved?
    • Natali, C., Ingle, P., and Dowell, J., 1996, "Orthopaedic Bone Drills: Can They be Improved?," J. Bone Jt. Surg., Br. Vol., 78, pp. 357-362.
    • (1996) J. Bone Jt. Surg., Br. , vol.78 , pp. 357-362
    • Natali, C.1    Ingle, P.2    Dowell, J.3
  • 38
    • 35348910955 scopus 로고    scopus 로고
    • Bone drilling haptic interaction for orthopedic surgical simulator
    • DOI 10.1016/j.compbiomed.2007.04.006, PII S001048250700087X
    • Tsai, M.-D., Hsieh, M.-S., and Tsai, C.-H., 2007, "Bone Drilling Haptic Interaction for Orthopedic Surgical Simulator," Comput. Biol. Med., 37, pp. 1709-1718. (Pubitemid 47577479)
    • (2007) Computers in Biology and Medicine , vol.37 , Issue.12 , pp. 1709-1718
    • Tsai, M.-D.1    Hsieh, M.-S.2    Tsai, C.-H.3
  • 39
    • 14644424620 scopus 로고    scopus 로고
    • The design and function of surgical drills and K-wires
    • DOI 10.1016/j.cuor.2004.12.011
    • Karmani, S., and Lam, F., 2004, "The Design and Function of Surgical Drills and K-Wires," Curr. Orthop., 18, pp. 484-490. (Pubitemid 40311822)
    • (2004) Current Orthopaedics , vol.18 , Issue.6 , pp. 484-490
    • Karmani, S.1    Lam, F.2
  • 40
    • 0030262371 scopus 로고    scopus 로고
    • 2 laser irradiation
    • DOI 10.1016/S0030-3992(96)00006-0, PII S0030399296000060
    • Yilbas, B. S., Yilbas, Z., and Sami, M., 1996, "Thermal Processes Taking Place in the Bone During CO2 Laser Irradiation," Opt. Laser Technol., 48(7), pp. 513-519. (Pubitemid 126380450)
    • (1996) Optics and Laser Technology , vol.28 , Issue.7 , pp. 513-519
    • Yilbas, B.S.1    Yilbas, Z.2    Sami, M.3
  • 41
    • 77950299044 scopus 로고    scopus 로고
    • A modified adaptive controller design for teleoperation systems
    • Hosseini-Suny, K., Momeni, H., and Janabi-Sharifi, F., 2010, "A Modified Adaptive Controller Design for Teleoperation Systems," Rob. Auton. Syst., 58, pp. 676-683.
    • (2010) Rob. Auton. Syst , vol.58 , pp. 676-683
    • Hosseini-Suny, K.1    Momeni, H.2    Janabi-Sharifi, F.3
  • 42
    • 84873140510 scopus 로고    scopus 로고
    • Sawbones Worldwide Retrieved Aug 1 2012
    • Sawbones Worldwide, 2012, "Custom Orthopaedic Medical Models for Training," Retrieved Aug. 1, 2012, www.sawbones.com/catalog/pdf/us-catalog. pdf
    • (2012) Custom Orthopaedic Medical Models for Training
  • 43
    • 34248189246 scopus 로고    scopus 로고
    • The biomechanics of human femurs in axial and torsional loading: Comparison of finite element analysis, human cadaveric femurs, and synthetic femurs
    • DOI 10.1115/1.2401178
    • Papini, M., Zdero, R., Schemitsch, E. H., and Zalzal, P., 2007, "The Biomechanics of Human Femurs in Axial and Torsional Loading: Comparison of Finite Element Analysis, Human Cadaveric Femurs, and Synthetic Femurs," J. Biomech. Eng., 129(1), pp. 12-19. (Pubitemid 46712831)
    • (2007) Journal of Biomechanical Engineering , vol.129 , Issue.1 , pp. 12-19
    • Papini, M.1    Zdero, R.2    Schemitsch, E.H.3    Zalzal, P.4
  • 44
    • 0034922981 scopus 로고    scopus 로고
    • Structural properties of a new design of composite replicate femurs and tibias
    • DOI 10.1016/S0021-9290(01)00015-X, PII S002192900100015X
    • Heiner, A. D., and Brown, T. D., 2001, "Structural Properties of a New Design of Composite Replicate Femurs and Tibias," J. Biomech., 34, pp. 773-781. (Pubitemid 32674356)
    • (2001) Journal of Biomechanics , vol.34 , Issue.6 , pp. 773-781
    • Heiner, A.D.1    Brown, T.D.2
  • 45
    • 0030131155 scopus 로고    scopus 로고
    • Mechanical validation of whole bone composite femur models
    • DOI 10.1016/0021-9290(95)00084-4
    • Cristofolini, L., Viceconti, M., Cappello, A., and Toni, A., 1996, "Mechanical Validation of Whole Bone Composite Femur Models," J. Biomech., 29(4), pp. 525-535. (Pubitemid 26065734)
    • (1996) Journal of Biomechanics , vol.29 , Issue.4 , pp. 525-535
    • Cristofolini, L.1    Viceconti, M.2    Cappello, A.3    Toni, A.4
  • 46
    • 77949694324 scopus 로고    scopus 로고
    • Cortical screw purchase in synthetic and human femurs
    • Zdero, R., Elfallah, K., Olsen, M., and Schemitsch, E. H., 2009, "Cortical Screw Purchase in Synthetic and Human Femurs," J. Biomech. Eng., 131(9), p. 094503.
    • (2009) J. Biomech. Eng , vol.131 , Issue.9 , pp. 094503
    • Zdero, R.1    Elfallah, K.2    Olsen, M.3    Schemitsch, E.H.4
  • 47
    • 60549092945 scopus 로고    scopus 로고
    • Cancellous bone screw purchase: A comparison of synthetic femurs, human femurs, and finite element analysis
    • Zdero, R., Olsen, M., Bougherara, H., and Schemitsch, E. H., 2008, "Cancellous Bone Screw Purchase: A Comparison of Synthetic Femurs, Human Femurs, and Finite Element Analysis," Proc. Inst. Mech. Eng., Part H: J. Eng. Med., 222(H8), pp. 1175-1183.
    • (2008) Proc. Inst. Mech. Eng., Part H: J. Eng. Med , vol.222 , Issue.H8 , pp. 1175-1183
    • Zdero, R.1    Olsen, M.2    Bougherara, H.3    Schemitsch, E.H.4
  • 50
    • 33747372876 scopus 로고    scopus 로고
    • Effect of trabecular bone loss on cortical strain rate during impact in an in vitro model of avian femur
    • Reich, T., and Gefen, A., 2006, "Effect of Trabecular Bone Loss on Cortical Strain Rate During Impact in an In Vitro Model of Avian Femur," Biomed. Eng. Online, 5:45.
    • (2006) Biomed. Eng. Online , vol.5 , pp. 45
    • Reich, T.1    Gefen, A.2
  • 51
    • 16244407996 scopus 로고    scopus 로고
    • Trabecular bone contributes to strength of the proximal femur under mediolateral impact in the avian
    • DOI 10.1115/1.1835366
    • Passi, N., and Gefen, A., 2005, "Trabecular Bone Contributes to Strength of the Proximal Femur Under Mediolateral Impact in the Avian," J. Biomech. Eng., 127(1) pp. 198-203. (Pubitemid 40463494)
    • (2005) Journal of Biomechanical Engineering , vol.127 , Issue.1 , pp. 198-203
    • Passi, N.1    Gefen, A.2
  • 52
    • 84873163094 scopus 로고    scopus 로고
    • B.Sc. thesis, School of Science and Technology, SIM University, Singapore
    • Lim, T. Y., 2009, "Investigation on Animal Bone Strength," B.Sc. thesis, School of Science and Technology, SIM University, Singapore.
    • (2009) Investigation on Animal Bone Strength
    • Lim, T.Y.1
  • 55
    • 34548281756 scopus 로고    scopus 로고
    • Biomechanics of bone
    • 3rd ed. V. C. Mow and R. Huiskes, eds. Lippincott Williams and Wilkins, Philadelphia, PA
    • Huiskes, R., and Van Rietbergen, B., 2005, "Biomechanics of Bone," Basic Orthopaedic Biomechanics and Mechano-Biology, 3rd ed., V. C. Mow and R. Huiskes, eds., Lippincott Williams and Wilkins, Philadelphia, PA, pp. 123-179.
    • (2005) Basic Orthopaedic Biomechanics and Mechano-Biology , pp. 123-179
    • Huiskes, R.1    Van Rietbergen, B.2
  • 56
    • 0038481100 scopus 로고    scopus 로고
    • Theoretical analysis on chatter vibration in drilling and its suppression
    • Ema, S., and Marui, E., 2003, "Theoretical Analysis on Chatter Vibration in Drilling and its Suppression," J. Mater. Process. Technol., 138, pp. 572-583.
    • (2003) J. Mater. Process. Technol , vol.138 , pp. 572-583
    • Ema, S.1    Marui, E.2
  • 58
    • 80052925100 scopus 로고    scopus 로고
    • A biomechanical comparison of epiphyseal versus metaphyseal fixed bone-conserving hip arthroplasty
    • Olsen, M., Sellan, M., Zdero, R., Waddell, J. P., and Schemitsch, E. H., 2011, "A Biomechanical Comparison of Epiphyseal Versus Metaphyseal Fixed Bone-Conserving Hip Arthroplasty," J. Bone Jt. Surg., Am. Vol., 93(Suppl 2), pp. 122-127.
    • (2011) J. Bone Jt. Surg., Am. Vol , vol.93 , Issue.SUPPL. 2 , pp. 122-127
    • Olsen, M.1    Sellan, M.2    Zdero, R.3    Waddell, J.P.4    Schemitsch, E.H.5
  • 61
    • 28344455806 scopus 로고    scopus 로고
    • Influence of process parameters on cutting force and torque during drilling of glass-fiber polyester reinforced composites
    • DOI 10.1016/j.compstruct.2005.09.039, PII S0263822305002722, Fifth International Conference on Composite Science a Technology ICCST/5
    • Mohan, N. S., Ramachandra, A., and Kulkarni, S. M., 2005, "Influence of Process Parameters on Cutting Force and Torque During Drilling of Glass-Fiber Polyester Reinforced Composites," Compos. Struct., 71, pp. 407-413. (Pubitemid 41715431)
    • (2005) Composite Structures , vol.71 , Issue.3-4 , pp. 407-413
    • Mohan, N.S.1    Ramachandra, A.2    Kulkarni, S.M.3
  • 62
    • 1642552929 scopus 로고
    • Observations on the effects of static and impact loading on the human femur
    • Mather, B. S., 1968, "Observations on the Effects of Static and Impact Loading on the Human Femur," J. Biomech., 1(4), pp. 331-335.
    • (1968) J. Biomech , vol.1 , Issue.4 , pp. 331-335
    • Mather, B.S.1
  • 63
    • 63449111351 scopus 로고    scopus 로고
    • The effect of screw pullout rate on screw purchase in synthetic cancellous bone
    • Zdero, R., and Schemitsch, E. H., 2009, "The Effect of Screw Pullout Rate on Screw Purchase in Synthetic Cancellous Bone," J. Biomech. Eng., 131(2), p. 024501.
    • (2009) J. Biomech. Eng , vol.131 , Issue.2 , pp. 024501
    • Zdero, R.1    Schemitsch, E.H.2
  • 64
    • 77949764662 scopus 로고    scopus 로고
    • The effect of the screw pull-out rate on cortical screw purchase in unreamed and reamed synthetic long bones
    • Zdero, R., Shah, S., Mosli, M., Bougherara, H., and Schemitsch, E. H., 2010, "The Effect of the Screw Pull-Out Rate on Cortical Screw Purchase in Unreamed and Reamed Synthetic Long Bones," Proc. Inst. Mech. Eng., Part H: J. Eng. Med., 224(3), pp. 503-513.
    • (2010) Proc. Inst. Mech. Eng., Part H: J. Eng. Med , vol.224 , Issue.3 , pp. 503-513
    • Zdero, R.1    Shah, S.2    Mosli, M.3    Bougherara, H.4    Schemitsch, E.H.5
  • 65
    • 0015301831 scopus 로고
    • Temperatures measured in human cortical bone when drilling
    • Matthews, L. S., and Hirsch, C., 1972, "Temperatures Measured in Human Cortical Bone When Drilling," J. Bone Jt. Surg., Am. Vol., 54, pp. 297-308.
    • (1972) J. Bone Jt. Surg., Am. , vol.54 , pp. 297-308
    • Matthews, L.S.1    Hirsch, C.2
  • 66
    • 34249112008 scopus 로고    scopus 로고
    • Mathematical model to predict tool wear on the machining of glass fibre reinforced plastic composites
    • DOI 10.1016/j.matdes.2006.06.018, PII S0261306906002123
    • Palanikumar, K., and Paulo Davim, J., 2007, "Mathematical Model to Predict Tool Wear on the Machining of Glass Fibre Reinforced Plastic Composites," Mater. Des., 28, pp. 2008-2014. (Pubitemid 46796695)
    • (2007) Materials and Design , vol.28 , Issue.7 , pp. 2008-2014
    • Palanikumar, K.1    Paulo Davim, J.2
  • 67
    • 84873108700 scopus 로고    scopus 로고
    • Analysis of tool wear rate in drilling operation using scanning electron microscope (SEM
    • Jindal, A., 2012, "Analysis of Tool Wear Rate in Drilling Operation Using Scanning Electron Microscope (SEM)," J. Min. Mater. Charact. Eng., 11(1), pp. 43-54.
    • (2012) J. Min. Mater. Charact. Eng , vol.11 , Issue.1 , pp. 43-54
    • Jindal, A.1
  • 69
    • 0013864447 scopus 로고
    • Factors affecting the determination of the physical properties of femoral cortical bone
    • Sedlin, E. D., and Hirsch, C., 1966, "Factors Affecting the Determination of the Physical Properties of Femoral Cortical Bone," Acta Orthop. Scand., 37, pp. 29-48.
    • (1966) Acta Orthop. Scand , vol.37 , pp. 29-48
    • Sedlin, E.D.1    Hirsch, C.2
  • 70
    • 0000967513 scopus 로고
    • Histopathologic reaction of bone to surgical cutting
    • Moss, R. W., 1964, "Histopathologic Reaction of Bone to Surgical Cutting," Oral Surg., Oral Med., Oral Pathol., 17, pp. 405-414.
    • (1964) Oral Surg., Oral Med., Oral Pathol , vol.17 , pp. 405-414
    • Moss, R.W.1
  • 71
    • 0004998823 scopus 로고
    • A study of the effects of high-speed rotary instruments on bone repair in dogs
    • Costich, E. R., Youngblood, P. J., and Walden, J. M., 1964, "A Study of the Effects of High-Speed Rotary Instruments on Bone Repair in Dogs," Oral Surg., Oral Med., Oral Pathol., 17, pp. 563-571.
    • (1964) Oral Surg., Oral Med., Oral Pathol , vol.17 , pp. 563-571
    • Costich, E.R.1    Youngblood, P.J.2    Walden, J.M.3
  • 72
    • 84873207184 scopus 로고    scopus 로고
    • Influence of process parameters on cutting force and torque of drilling of glass fiber reinforced epoxy composites
    • Elias, G. K., Varadarajan, A. S., Rani, J., 2012, "Influence of Process Parameters on Cutting Force and Torque of Drilling of Glass Fiber Reinforced Epoxy Composites," Int. J. Comput. Technol. Electron. Eng., 2(2), pp. 26-31.
    • (2012) Int. J. Comput. Technol. Electron. Eng , vol.2 , Issue.2 , pp. 26-31
    • Elias, G.K.1    Varadarajan, A.S.2    Rani, J.3
  • 73
    • 0030296191 scopus 로고    scopus 로고
    • The tensile behavior of demineralized bovine cortical bone
    • DOI 10.1016/0021-9290(96)84546-5
    • Bowman, S. M., Zeind, J., Gibson, L. J., Hayes, W. C., and McMahon, T. A., 1996, "The Tensile Behavior of Demineralized Bovine Cortical Bone," J. Biomech., 29(11), pp. 1497-1501. (Pubitemid 26329200)
    • (1996) Journal of Biomechanics , vol.29 , Issue.11 , pp. 1497-1501
    • Bowman, S.M.1    Zeind, J.2    Gibson, L.J.3    Hayes, W.C.4    McMahon, T.A.5
  • 74
    • 0019844822 scopus 로고
    • Fatigue behavior of adult cortical bone: The influence of mean strain and strain range
    • Carter, D. R., Caler, W. E., Spengler, D. M., and Frankel, V. H., 1981, "Fatigue Behavior of Adult Cortical Bone: The Influence of Mean Strain and Strain Range," Acta Orthop. Scand., 52(5), pp. 481-490. (Pubitemid 12237998)
    • (1981) Acta Orthopaedica Scandinavica , vol.52 , Issue.5 , pp. 481-490
    • Carter, D.R.1    Caler, W.E.2    Spengler, D.M.3    Frankel, V.H.4
  • 75
    • 84859882942 scopus 로고    scopus 로고
    • The biomechanical effect of torsion on humeral shaft repair techniques for completed pathological fractures
    • Al-Jahwari, A., Schemitsch, E. H., Wunder, J. S., Ferguson, P. C., and Zdero, R., 2012, "The Biomechanical Effect of Torsion on Humeral Shaft Repair Techniques for Completed Pathological Fractures", J. Biomech. Eng., 134(2), p. 024501.
    • (2012) J. Biomech. Eng , vol.134 , Issue.2 , pp. 024501
    • Al-Jahwari, A.1    Schemitsch, E.H.2    Wunder, J.S.3    Ferguson, P.C.4    Zdero, R.5
  • 77
    • 0036793962 scopus 로고    scopus 로고
    • Mechanical properties of the periosteum in the pig, Sus scrofa
    • DOI 10.1016/S0003-9969(02)00065-1, PII S0003996902000651
    • Popowics, T. E., Zhub, Z., and Herring, S. W., 2002, "Mechanical Properties of the Periosteum in the Pig, Sus Scrofa," Arch. Oral Biol., 47, pp. 733-741. (Pubitemid 35175768)
    • (2002) Archives of Oral Biology , vol.47 , Issue.10 , pp. 733-741
    • Popowics, T.E.1    Zhu, Z.2    Herring, S.W.3
  • 78
    • 0032101656 scopus 로고    scopus 로고
    • Mechanics of avian fibrous periosteum: Tensile and adhesion properties during growth
    • DOI 10.1016/S8756-3282(98)00035-0
    • Bertram, J. E. A., Polevoy, Y., Cullinane, D. M., 1998, "Mechanics of Avian Fibrous Periosteum: Tensile and Adhesion Properties During Growth," Bone, 22, pp. 669-675. (Pubitemid 28284617)
    • (1998) Bone , vol.22 , Issue.6 , pp. 669-675
    • Bertram, J.E.A.1    Polevoy, Y.2    Cullinane, D.M.3
  • 79
    • 0032006915 scopus 로고    scopus 로고
    • Measurement of mechanical characteristics of tibial periosteum and evaluation of local differences
    • Uchiyama, E., Yamakoshi, K., and Sasaki, T., 1998, "Measurement of Mechanical Characteristics of Tibial Periosteum and Evaluation of Local Differences," J. Biomech. Eng., 120, pp. 85-91. (Pubitemid 28110443)
    • (1998) Journal of Biomechanical Engineering , vol.120 , Issue.1 , pp. 85-91
    • Uchiyama, E.1    Yamakoshi, K.2    Sasaki, T.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.