메뉴 건너뛰기




Volumn 6, Issue 1, 2013, Pages 86-91

Evaluation of renal blood flow using multi-phase echo-planar magnetic resonance imaging and signal targeting with alternating radiofrequency (EPISTAR) in 3-T magnetic resonance imaging

Author keywords

Arterial spin labeling; Magnetic resonance imaging; Renal blood flow; Renal perfusion

Indexed keywords

ARTICLE; CONTROLLED STUDY; ECHO PLANAR MAGNETIC RESONANCE IMAGING AND SIGNAL TARGETING WITH ALTERNATING RADIOFREQUENCY; HUMAN; HUMAN EXPERIMENT; KIDNEY BLOOD FLOW; KIDNEY CORTEX; KIDNEY PERFUSION; NORMAL HUMAN; NUCLEAR MAGNETIC RESONANCE IMAGING; PRIORITY JOURNAL; SPIN LABELING;

EID: 84873102004     PISSN: 18650333     EISSN: 18650341     Source Type: Journal    
DOI: 10.1007/s12194-012-0173-2     Document Type: Article
Times cited : (3)

References (24)
  • 1
    • 0024849139 scopus 로고
    • Estimation of Tc-99m-MAG3 plasma clearance in adults from one or two blood samples
    • 2531219 1:STN:280:DyaK3c%2FmtlOqtg%3D%3D
    • Russell CD, Taylor A, Eshima D. Estimation of Tc-99m-MAG3 plasma clearance in adults from one or two blood samples. J Nucl Med. 1989;30:1955-9.
    • (1989) J Nucl Med , vol.30 , pp. 1955-1959
    • Russell, C.D.1    Taylor, A.2    Eshima, D.3
  • 2
    • 0026781518 scopus 로고
    • Predicting glomerular function from adjusted serum creatinine
    • 1436333 10.1159/000187054 1:CAS:528:DyaK3sXjsFeqsw%3D%3D
    • Gault MH, Longerich LL, Harnett JD, Wesolowski C. Predicting glomerular function from adjusted serum creatinine. Nephron. 1992;62:249-56.
    • (1992) Nephron , vol.62 , pp. 249-256
    • Gault, M.H.1    Longerich, L.L.2    Harnett, J.D.3    Wesolowski, C.4
  • 3
    • 0017252235 scopus 로고
    • Comparison of inulin, iothalamate, and 99mTc-DTPA for measurement of glomerular filtration rate
    • 1255261 1:CAS:528:DyaE28XhslGru78%3D
    • Barbour GL, Crumb CK, Boyd CM, Reeves RD, Rastogi SP, Patterson RM. Comparison of inulin, iothalamate, and 99mTc-DTPA for measurement of glomerular filtration rate. J Nucl Med. 1976;17:317-20.
    • (1976) J Nucl Med , vol.17 , pp. 317-320
    • Barbour, G.L.1    Crumb, C.K.2    Boyd, C.M.3    Reeves, R.D.4    Rastogi, S.P.5    Patterson, R.M.6
  • 4
    • 0042829381 scopus 로고    scopus 로고
    • Noninvasive measurement of absolute renal perfusion by contrast medium-enhanced magnetic resonance imaging
    • 12960528 10.1097/01.RLI.0000077127.11949.8c 1:CAS:528: DC%2BD3sXntVOqs7o%3D
    • Montet X, Ivancevic MK, Belenger J, Jorge-Costa M, Pochon S, Pechère A, et al. Noninvasive measurement of absolute renal perfusion by contrast medium-enhanced magnetic resonance imaging. Invest Radiol. 2003;38:584-92.
    • (2003) Invest Radiol , vol.38 , pp. 584-592
    • Montet, X.1    Ivancevic, M.K.2    Belenger, J.3    Jorge-Costa, M.4    Pochon, S.5    Pechère, A.6
  • 5
    • 0025765943 scopus 로고
    • Measurement of tissue perfusion by dynamic computed tomography
    • 2036562 10.1259/0007-1285-64-761-409 1:STN:280:DyaK3M3kt12ruw%3D%3D
    • Miles KA. Measurement of tissue perfusion by dynamic computed tomography. Br J Radiol. 1991;64:409-12.
    • (1991) Br J Radiol , vol.64 , pp. 409-412
    • Miles, K.A.1
  • 6
    • 33645289942 scopus 로고    scopus 로고
    • Gadolinium: A specific trigger for the development of nephrogenic fibrosing dermopathy and nephrogenic systemic fibrosis
    • 16431890 10.1093/ndt/gfk062 1:CAS:528:DC%2BD28XivVOntb8%3D
    • Grobner T. Gadolinium: a specific trigger for the development of nephrogenic fibrosing dermopathy and nephrogenic systemic fibrosis. Nephrol Dial Transplant. 2006;21:1104-8.
    • (2006) Nephrol Dial Transplant , vol.21 , pp. 1104-1108
    • Grobner, T.1
  • 7
    • 73649086605 scopus 로고    scopus 로고
    • Nephrogenic systemic fibrosis versus contrast induced nephropathy: Risks and benefits of contrast-enhanced MR and CT in renally impaired patients
    • 19937934 10.1002/jmri.21968
    • Martin DR, Semelka RC, Chapman A, Peters H, Finn PJ, Kalb B, et al. Nephrogenic systemic fibrosis versus contrast induced nephropathy: risks and benefits of contrast-enhanced MR and CT in renally impaired patients. J Magn Reson Imaging. 2009;30(6):1350-6.
    • (2009) J Magn Reson Imaging , vol.30 , Issue.6 , pp. 1350-1356
    • Martin, D.R.1    Semelka, R.C.2    Chapman, A.3    Peters, H.4    Finn, P.J.5    Kalb, B.6
  • 8
    • 33747590330 scopus 로고    scopus 로고
    • Non-invasive measurement of perfusion: A critical review of arterial spin labelling techniques
    • 16861326 10.1259/bjr/67705974 1:STN:280:DC%2BD28vjs1Gjtw%3D%3D
    • Petersen ET, Zimine I, Ho YC, Golay X. Non-invasive measurement of perfusion: a critical review of arterial spin labelling techniques. Br J Radiol. 2006;79:688-701.
    • (2006) Br J Radiol , vol.79 , pp. 688-701
    • Petersen, E.T.1    Zimine, I.2    Ho, Y.C.3    Golay, X.4
  • 9
    • 0030725989 scopus 로고    scopus 로고
    • Implementation of quantitative perfusion imaging techniques for functional brain mapping using pulsed arterial spin labeling
    • 9430354 10.1002/(SICI)1099-1492(199706/08)10:4/5<237: AID-NBM475>3.0.CO;2-X 1:STN:280:DyaK1c%2FptVaiuw%3D%3D
    • Wong EC, Buxton RB, Frank LR. Implementation of quantitative perfusion imaging techniques for functional brain mapping using pulsed arterial spin labeling. NMR Biomed. 1997;10:237-49.
    • (1997) NMR Biomed , vol.10 , pp. 237-249
    • Wong, E.C.1    Buxton, R.B.2    Frank, L.R.3
  • 10
    • 0031019253 scopus 로고    scopus 로고
    • Perfusion imaging by a flow-sensitive alternating inversion recovery (FAIR) technique: Application to functional brain imaging
    • 9055234 10.1002/mrm.1910370321 1:STN:280:DyaK2s3gsl2qug%3D%3D
    • Kim SG, Tsekos NV. Perfusion imaging by a flow-sensitive alternating inversion recovery (FAIR) technique: application to functional brain imaging. Magn Reson Med. 1997;37:425-35.
    • (1997) Magn Reson Med , vol.37 , pp. 425-435
    • Kim, S.G.1    Tsekos, N.V.2
  • 11
    • 0033049396 scopus 로고    scopus 로고
    • Perfusion magnetic resonance imaging with continuous arterial spin labeling: Methods and clinical applications in the central nervous system
    • 10401592 10.1016/S0720-048X(99)00050-9 1:STN:280:DyaK1MzivFygtw%3D%3D
    • Detre JA, Alsop DC. Perfusion magnetic resonance imaging with continuous arterial spin labeling: methods and clinical applications in the central nervous system. Eur J Radiol. 1999;30:115-24.
    • (1999) Eur J Radiol , vol.30 , pp. 115-124
    • Detre, J.A.1    Alsop, D.C.2
  • 12
    • 0032857913 scopus 로고    scopus 로고
    • Pseudo-continuous arterial spin labeling technique for measuring CBF dynamics with high temporal resolution
    • 10467285 10.1002/(SICI)1522-2594(199909)42:3<425: AID-MRM3>3.0. CO;2-S 1:STN:280:DyaK1MzpvVGmsQ%3D%3D
    • Silva AC, Kim SG. Pseudo-continuous arterial spin labeling technique for measuring CBF dynamics with high temporal resolution. Magn Reson Med. 1999;42:425-9.
    • (1999) Magn Reson Med , vol.42 , pp. 425-429
    • Silva, A.C.1    Kim, S.G.2
  • 13
    • 77953049771 scopus 로고    scopus 로고
    • Perfusion MRI of brain tumours: A comparative study of pseudo-continuous arterial spin labelling and dynamic susceptibility contrast imaging
    • 19841916 10.1007/s00234-009-0616-6
    • Järnum H, Steffensen EG, Knutsson L, Fründ ET, Simonsen CW, Lundbye-Christensen S, et al. Perfusion MRI of brain tumours: a comparative study of pseudo-continuous arterial spin labelling and dynamic susceptibility contrast imaging. Neuroradiology. 2010;52(4):307-17.
    • (2010) Neuroradiology , vol.52 , Issue.4 , pp. 307-317
    • Järnum, H.1    Steffensen, E.G.2    Knutsson, L.3    Fründ, E.T.4    Simonsen, C.W.5    Lundbye-Christensen, S.6
  • 14
    • 33344460870 scopus 로고    scopus 로고
    • Perfusion MR imaging with FAIR true FISP spin labeling in patients with and without renal artery stenosis: Initial experience
    • 16439565 10.1148/radiol.2382041623
    • Fenchel M, Martirosian P, Langanke J, Giersch J, Miller S, Stauder NI, et al. Perfusion MR imaging with FAIR true FISP spin labeling in patients with and without renal artery stenosis: initial experience. Radiology. 2006;238:1013-21.
    • (2006) Radiology , vol.238 , pp. 1013-1021
    • Fenchel, M.1    Martirosian, P.2    Langanke, J.3    Giersch, J.4    Miller, S.5    Stauder, N.I.6
  • 16
    • 78349295250 scopus 로고    scopus 로고
    • Improved renal perfusion measurement with a dual navigator-gated Q2TIPS FAIR technique
    • 20593428 10.1002/mrm.22532
    • Song R, Loeffler RB, Hillenbrand CM. Improved renal perfusion measurement with a dual navigator-gated Q2TIPS FAIR technique. Magn Reson Med. 2010;64(5):1352-9.
    • (2010) Magn Reson Med , vol.64 , Issue.5 , pp. 1352-1359
    • Song, R.1    Loeffler, R.B.2    Hillenbrand, C.M.3
  • 17
    • 57149140646 scopus 로고    scopus 로고
    • A feasibility study on model-based evaluation of kidney perfusion measured by means of FAIR prepared true-FISP arterial spin labeling (ASL) on a 3 Tesla MR-scanner
    • 19064215 10.1016/j.acra.2008.04.024
    • Kiefer C, Schroth G, Gralla J, Diehm N, Baumgartner I, Husmann M. A feasibility study on model-based evaluation of kidney perfusion measured by means of FAIR prepared true-FISP arterial spin labeling (ASL) on a 3 Tesla MR-scanner. Acad Radiol. 2009;16(1):79-87.
    • (2009) Acad Radiol , vol.16 , Issue.1 , pp. 79-87
    • Kiefer, C.1    Schroth, G.2    Gralla, J.3    Diehm, N.4    Baumgartner, I.5    Husmann, M.6
  • 18
    • 0842285725 scopus 로고    scopus 로고
    • FAIR true-FISP perfusion imaging of the kidneys
    • 14755661 10.1002/mrm.10709
    • Martirosian P, Klose U, Mader I, Schick F. FAIR true-FISP perfusion imaging of the kidneys. Magn Reson Med. 2004;51:353-61.
    • (2004) Magn Reson Med , vol.51 , pp. 353-361
    • Martirosian, P.1    Klose, U.2    Mader, I.3    Schick, F.4
  • 19
    • 0033870368 scopus 로고    scopus 로고
    • Quantitation of renal perfusion using arterial spin labeling with FAIRUFLARE
    • 10.1016/S0730-725X(00)00155-7 1:STN:280:DC%2BD3cvntlyksg%3D%3D
    • Karger N, Biederer J, Lüsse S, Grimm J, Steffens J, Heller M, et al. Quantitation of renal perfusion using arterial spin labeling with FAIRUFLARE. Magn Reson Imag. 2000;18:641-7.
    • (2000) Magn Reson Imag. , vol.18 , pp. 641-647
    • Karger, N.1    Biederer, J.2    Lüsse, S.3    Grimm, J.4    Steffens, J.5    Heller, M.6
  • 20
    • 77952089937 scopus 로고    scopus 로고
    • Quantification of renal allograft perfusion using arterial spin labeling MRI: Initial results
    • 19949799 10.1007/s00330-009-1675-0
    • Lanzman RS, Wittsack HJ, Martirosian P, Zgoura P, Bilk P, Kröpil P, et al. Quantification of renal allograft perfusion using arterial spin labeling MRI: initial results. Eur Radiol. 2010;20(6):1485-91.
    • (2010) Eur Radiol , vol.20 , Issue.6 , pp. 1485-1491
    • Lanzman, R.S.1    Wittsack, H.J.2    Martirosian, P.3    Zgoura, P.4    Bilk, P.5    Kröpil, P.6
  • 21
    • 0027936294 scopus 로고
    • Quantitative mapping of cerebral blood flow and functional localization with echo-planar MR imaging and signal targeting with alternating radio-frequency
    • 8029425 1:STN:280:DyaK2czgt1antA%3D%3D
    • Edelman RR, Siewert B, Darby DG, Thangaraj V, Nobre AC, Mesulam MM, et al. Quantitative mapping of cerebral blood flow and functional localization with echo-planar MR imaging and signal targeting with alternating radio-frequency. Radiology. 1994;192:513-20.
    • (1994) Radiology , vol.192 , pp. 513-520
    • Edelman, R.R.1    Siewert, B.2    Darby, D.G.3    Thangaraj, V.4    Nobre, A.C.5    Mesulam, M.M.6
  • 22
    • 0035158457 scopus 로고    scopus 로고
    • A new method for fast multislice T1 mapping
    • 11697949 10.1006/nimg.2001.0886 1:STN:280:DC%2BD3Mnks1aqtw%3D%3D
    • Shah NJ, Zaitsev M, Steinhoff S, Zilles K. A new method for fast multislice T1 mapping. Neuroimage. 2001;14:1175-85.
    • (2001) Neuroimage , vol.14 , pp. 1175-1185
    • Shah, N.J.1    Zaitsev, M.2    Steinhoff, S.3    Zilles, K.4
  • 23
    • 35948969225 scopus 로고    scopus 로고
    • A theoretical and experimental investigation of the tagging efficiency of pseudocontinuous arterial spin labeling
    • 17969096 10.1002/mrm.21403
    • Wu WC, Fernandez-Seara M, Detre JA, Wehrli FW, Wang J. A theoretical and experimental investigation of the tagging efficiency of pseudocontinuous arterial spin labeling. Magn Reson Med. 2007;58:1020-7.
    • (2007) Magn Reson Med , vol.58 , pp. 1020-1027
    • Wu, W.C.1    Fernandez-Seara, M.2    Detre, J.A.3    Wehrli, F.W.4    Wang, J.5
  • 24
    • 0347363809 scopus 로고    scopus 로고
    • Transplant renal artery stenosis
    • 14694165 10.1097/01.ASN.0000099379.61001.F8
    • Bruno S, Remuzzi G, Ruggenenti P. Transplant renal artery stenosis. J Am Soc Nephrol. 2004;15:134-41.
    • (2004) J Am Soc Nephrol , vol.15 , pp. 134-141
    • Bruno, S.1    Remuzzi, G.2    Ruggenenti, P.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.