메뉴 건너뛰기




Volumn 46, Issue 4, 2013, Pages 1393-1398

Study on factors enhancing photobleaching effect of fluorescent dye

Author keywords

Fluorescent dye; Half life decay time; Measurement sensitivity; Photobleaching

Indexed keywords

BIOMEDICAL ENGINEERING; DIES; FLUORESCENCE; MICROFLUIDICS;

EID: 84873052771     PISSN: 02632241     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.measurement.2012.11.039     Document Type: Article
Times cited : (17)

References (20)
  • 1
    • 0001510349 scopus 로고    scopus 로고
    • Determination of accurate electroosmotic mobility and analyte effective mobility values in the presence of charged interacting agents in capillary electrophoresis
    • B.A. Williams, and G. Vigh Determination of accurate electroosmotic mobility and analyte effective mobility values in the presence of charged interacting agents in capillary electrophoresis Anal Chem. 69 1997 4445 4451
    • (1997) Anal Chem. , vol.69 , pp. 4445-4451
    • Williams, B.A.1    Vigh, G.2
  • 2
    • 0030242422 scopus 로고    scopus 로고
    • Method for the accelerated measurement of electroosmosis in chemically modified tubes for capillary electrophoresis
    • J.E. Sandoval, and S.M. Chen Method for the accelerated measurement of electroosmosis in chemically modified tubes for capillary electrophoresis Anal Chem. 68 1996 2771 2775
    • (1996) Anal Chem. , vol.68 , pp. 2771-2775
    • Sandoval, J.E.1    Chen, S.M.2
  • 3
    • 0030220537 scopus 로고    scopus 로고
    • Analysis of the overall accuracy in LDV measurement of film flow in an inclined channel
    • N. Aksel, and M. Schmidtchen Analysis of the overall accuracy in LDV measurement of film flow in an inclined channel Meas. Sci. Technol. 7 1996 1140 1147
    • (1996) Meas. Sci. Technol. , vol.7 , pp. 1140-1147
    • Aksel, N.1    Schmidtchen, M.2
  • 4
    • 0035357383 scopus 로고    scopus 로고
    • Three-dimensional particle-streak tracking (PST) velocity measurements of a heat exchanger inlet flow-a new method to measure all three air-flow velocity components in a plane is applied to a steady-state three-dimensional flow
    • D. Muller, B. Muller, and U. Renz Three-dimensional particle-streak tracking (PST) velocity measurements of a heat exchanger inlet flow-a new method to measure all three air-flow velocity components in a plane is applied to a steady-state three-dimensional flow Exp. Fluids 30 2001 645 656
    • (2001) Exp. Fluids , vol.30 , pp. 645-656
    • Muller, D.1    Muller, B.2    Renz, U.3
  • 5
    • 0141610073 scopus 로고    scopus 로고
    • Spatially averaged time-resolved particle-tracking velocimetry in microspace considering Brownian motion of submicron fluorescent particles
    • Y. Sato, S. Inaba, K. Hishida, and M. Maeda Spatially averaged time-resolved particle-tracking velocimetry in microspace considering Brownian motion of submicron fluorescent particles Exp. Fluids 35 2003 167 177
    • (2003) Exp. Fluids , vol.35 , pp. 167-177
    • Sato, Y.1    Inaba, S.2    Hishida, K.3    Maeda, M.4
  • 6
    • 10844243464 scopus 로고    scopus 로고
    • Microscale flow visualization
    • D. Sinton Microscale flow visualization Microfluid. Nanofluid. 1 2004 2 21
    • (2004) Microfluid. Nanofluid. , vol.1 , pp. 2-21
    • Sinton, D.1
  • 7
    • 3142690382 scopus 로고    scopus 로고
    • Optically sliced micro-PIV using confocal laser scanning microscopy (CLSM)
    • K.D. Kihm, J.S. Park, and C.K. Choi Optically sliced micro-PIV using confocal laser scanning microscopy (CLSM) Exp. Fluids 37 2004 105 119
    • (2004) Exp. Fluids , vol.37 , pp. 105-119
    • Kihm, K.D.1    Park, J.S.2    Choi, C.K.3
  • 8
    • 0025719702 scopus 로고
    • Flow-rate measurements in isolated perfused kidney-tubules by fluorescence photobleaching recovery
    • B. Flamion, P.M. Bungay, C.C. Gibson, and K.R. Spring Flow-rate measurements in isolated perfused kidney-tubules by fluorescence photobleaching recovery Biophys. J. 60 1991 1229 1242
    • (1991) Biophys. J. , vol.60 , pp. 1229-1242
    • Flamion, B.1    Bungay, P.M.2    Gibson, C.C.3    Spring, K.R.4
  • 9
    • 0036805884 scopus 로고    scopus 로고
    • Photobleached-fluorescence imaging of microflows
    • B.P. Mosier, J.I. Molho, and J.G. Santiago Photobleached-fluorescence imaging of microflows Exp. Fluids 33 2002 545 554
    • (2002) Exp. Fluids , vol.33 , pp. 545-554
    • Mosier, B.P.1    Molho, J.I.2    Santiago, J.G.3
  • 10
    • 17144410778 scopus 로고    scopus 로고
    • Laser induced fluorescence photobleaching anemometer for microfluidic devices
    • G.R. Wang Laser induced fluorescence photobleaching anemometer for microfluidic devices Lab Chip 5 2005 450 456
    • (2005) Lab Chip , vol.5 , pp. 450-456
    • Wang, G.R.1
  • 11
    • 41549130754 scopus 로고    scopus 로고
    • Photobleaching-based flow measurement in a commercial capillary electrophoresis chip instrument
    • G.R. Wang, I. Sas, H. Jiang, W.P. Janzen, and C.N. Hodge Photobleaching-based flow measurement in a commercial capillary electrophoresis chip instrument Electrophoresis 29 2008 1253 1263
    • (2008) Electrophoresis , vol.29 , pp. 1253-1263
    • Wang, G.R.1    Sas, I.2    Jiang, H.3    Janzen, W.P.4    Hodge, C.N.5
  • 12
    • 70349999417 scopus 로고    scopus 로고
    • Measuring flow velocity distribution in microchannels using molecular tracers
    • C.F. Kuang, G.R. Wang, W. Zhao, and F. Yang Measuring flow velocity distribution in microchannels using molecular tracers Microfluid. Nanofluid. 7 2009 509 517
    • (2009) Microfluid. Nanofluid. , vol.7 , pp. 509-517
    • Kuang, C.F.1    Wang, G.R.2    Zhao, W.3    Yang, F.4
  • 13
    • 68849123700 scopus 로고    scopus 로고
    • Study of the rise time in electroosmotic flow within a microcapillary
    • C.F. Kuang, G.R. Wang, F. Yang, and W. Zhao Study of the rise time in electroosmotic flow within a microcapillary Anal Chem. 81 2009 6590 6595
    • (2009) Anal Chem. , vol.81 , pp. 6590-6595
    • Kuang, C.F.1    Wang, G.R.2    Yang, F.3    Zhao, W.4
  • 14
    • 0017192686 scopus 로고
    • Mobility measurement by analysis of fluorescence photobleaching recovery kinetics
    • D. Axelrod, D.E. Koppel, J. Schlessinger, E. Elson, and W.W. Webb Mobility measurement by analysis of fluorescence photobleaching recovery kinetics Biophys. J. 16 1976 1055 1069
    • (1976) Biophys. J. , vol.16 , pp. 1055-1069
    • Axelrod, D.1    Koppel, D.E.2    Schlessinger, J.3    Elson, E.4    Webb, W.W.5
  • 15
    • 0029292981 scopus 로고
    • Photobleaching of disodium fluorescein in water
    • J.R. Saylor Photobleaching of disodium fluorescein in water Exp. Fluids 18 1995 445 447
    • (1995) Exp. Fluids , vol.18 , pp. 445-447
    • Saylor, J.R.1
  • 16
    • 0011254367 scopus 로고    scopus 로고
    • On high spatial resolution scalar measurement with LIF-Part 1: Photobleaching and thermal blooming
    • G.R. Wang, and H.E. Fiedler On high spatial resolution scalar measurement with LIF-Part 1: Photobleaching and thermal blooming Exp. Fluids 29 2000 257 264
    • (2000) Exp. Fluids , vol.29 , pp. 257-264
    • Wang, G.R.1    Fiedler, H.E.2
  • 17
    • 85027929461 scopus 로고    scopus 로고
    • Ultrafast measurement of transient electroosmotic flow in microfluidics
    • C. Kuang, R. Qiao, and G. Wang Ultrafast measurement of transient electroosmotic flow in microfluidics Microfluid. Nanofluid. 2011 1 6
    • (2011) Microfluid. Nanofluid. , pp. 1-6
    • Kuang, C.1    Qiao, R.2    Wang, G.3
  • 19
    • 0022160694 scopus 로고
    • Laser-induced fluorescence measurements of mixed fluid concentration in a liquid plane shear-layer
    • M.M. Koochesfahani, and P.E. Dimotakis Laser-induced fluorescence measurements of mixed fluid concentration in a liquid plane shear-layer AIAA J. 23 1985 1700 1707
    • (1985) AIAA J. , vol.23 , pp. 1700-1707
    • Koochesfahani, M.M.1    Dimotakis, P.E.2
  • 20
    • 34247489528 scopus 로고
    • Absorption and fluorescence properties of fluorescein
    • R. Sjoback, J. Nygren, and M. Kubista Absorption and fluorescence properties of fluorescein Spectrochim. Acta A 51 1995 L7 L21
    • (1995) Spectrochim. Acta A , vol.51
    • Sjoback, R.1    Nygren, J.2    Kubista, M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.