메뉴 건너뛰기




Volumn 9, Issue 1, 2013, Pages 23-31

Preventing power transformer failures through electrical incipient fault analysis

Author keywords

Dissolved gas analysis; Incipient faults; Low energy arcing; Partial discharge; Power transformer

Indexed keywords

DISSOLUTION; GAS CHROMATOGRAPHY; GASES; INSULATION; OIL FILLED TRANSFORMERS; POWER TRANSFORMERS; REGRESSION ANALYSIS;

EID: 84873019257     PISSN: 09731318     EISSN: 29938341     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (3)

References (10)
  • 1
    • 17044395044 scopus 로고    scopus 로고
    • Assessment of Transformer Insulation System by Evaluating Partial Discharge and Dissolved Gas Analysis
    • Verma, P., M. Roy, A. Verma, and V. Bhanot. Assessment of Transformer Insulation System by Evaluating Partial Discharge and Dissolved Gas Analysis. Journal of Scientific & Industrial Research, April 2005; 64: 262-267.
    • (2005) Journal of Scientific & Industrial Research, April , vol.64 , pp. 262-267
    • Verma, P.1    Roy, M.2    Verma, A.3    Bhanot, V.4
  • 2
    • 65949084059 scopus 로고    scopus 로고
    • Ph.D. Thesis, Thapar Institute of Engineering & Technology (Deemed University), Department of Electrical and Instrumentation Engineering
    • Verma, P., Condition Monitoring of Transformer Oil and Paper. Ph.D. Thesis, Thapar Institute of Engineering & Technology (Deemed University), Department of Electrical and Instrumentation Engineering, 2005.
    • (2005) Condition Monitoring of Transformer Oil and Paper
    • Verma, P.1
  • 4
    • 78751539665 scopus 로고    scopus 로고
    • Using Partial Discharge as Sample Signal Ssource to Identify Contamination Moisture Pattern in Power Transformer Insulating Oil
    • Glendale, AZ, Nov. 7-10
    • Veloso, G.F.C., L. E. B. Da Silva, I. Noronha, and G. L. Torres. Using Partial Discharge as Sample Signal Ssource to Identify Contamination Moisture Pattern in Power Transformer Insulating Oil. 36th Annual Conference on IEEE Industrial Electronics, Glendale, AZ, Nov. 7-10, 2010;1041-1044.
    • (2010) 36th Annual Conference on IEEE Industrial Electronics , pp. 1041-1044
    • Veloso, G.F.C.1    da Silva, L.E.B.2    Noronha, I.3    Torres, G.L.4
  • 7
    • 17644409075 scopus 로고    scopus 로고
    • Partial Discharge Monitoring of Power Transformers using UHF Sensors Part I: Sensors and Signal Interpretation
    • Judd, M. D., L. Yang, and I. B. B. Hunter. Partial Discharge Monitoring of Power Transformers using UHF Sensors Part I: Sensors and Signal Interpretation. IEEE Electrical Insulation Magazine 2005; 21(2): 5-14.
    • (2005) IEEE Electrical Insulation Magazine , vol.21 , Issue.2 , pp. 5-14
    • Judd, M.D.1    Yang, L.2    Hunter, I.B.B.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.