메뉴 건너뛰기




Volumn 178, Issue , 2013, Pages 339-342

Bismuth-based porous screen-printed carbon electrode with enhanced sensitivity for trace heavy metal detection by stripping voltammetry

Author keywords

Bismuth film; Cadmium(II); Lead(II); Porous screen printed carbon electrode; Stripping voltammetry

Indexed keywords

ACTIVE AREA; AG/AGCL; ANALYTES; BI FILMS; BISMUTH FILM; DETECTION LIMITS; ENHANCED SENSITIVITY; GLASSY CARBON ELECTRODES; LOW BACKGROUND; PRE-CONCENTRATION; ROUGH SURFACES; SCREEN-PRINTED CARBON ELECTRODES; STRIPPING VOLTAMMETRY; TRACE HEAVY METALS; WATER SAMPLES;

EID: 84872917986     PISSN: 09254005     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.snb.2012.12.109     Document Type: Article
Times cited : (77)

References (19)
  • 1
    • 0034661524 scopus 로고    scopus 로고
    • Bismuth-coated carbon electrodes for anodic stripping voltammetry
    • DOI 10.1021/ac000108x
    • J. Wang, J. Lu, S.B. Hocevar, P.A.M. Farias, and B. Ogorevc Bismuth-coated carbon electrodes for anodic stripping voltammetry Analytical Chemistry 72 2000 3218 3222 (Pubitemid 30482494)
    • (2000) Analytical Chemistry , vol.72 , Issue.14 , pp. 3218-3222
    • Wang, J.1    Lu, J.2    Hocevar, S.B.3    Farias, P.A.M.4    Ogorevc, B.5
  • 2
    • 77953131139 scopus 로고    scopus 로고
    • Determination of trace selenium by differential pulse adsorptive stripping voltammetry at a bismuth film electrode
    • Q. Zhang, X. Li, H. Shi, H. Zhou, and Z. Yuan Determination of trace selenium by differential pulse adsorptive stripping voltammetry at a bismuth film electrode Electrochimica Acta 55 2010 4717 4721
    • (2010) Electrochimica Acta , vol.55 , pp. 4717-4721
    • Zhang, Q.1    Li, X.2    Shi, H.3    Zhou, H.4    Yuan, Z.5
  • 3
    • 4544353415 scopus 로고    scopus 로고
    • Characterization and applications of a bismuth bulk electrode
    • R. Pauliukaite, S.B. Hočevar, B. Ogorevc, and J. Wang Characterization and applications of a bismuth bulk electrode Electroanalysis 16 2004 719 723
    • (2004) Electroanalysis , vol.16 , pp. 719-723
    • Pauliukaite, R.1    Hočevar, S.B.2    Ogorevc, B.3    Wang, J.4
  • 4
    • 79954624834 scopus 로고    scopus 로고
    • Disposable lithographically fabricated bismuth microelectrode arrays for stripping voltammetric detection of trace metals
    • C. Kokkinos, A. Economou, I. Raptis, and T. Speliotis Disposable lithographically fabricated bismuth microelectrode arrays for stripping voltammetric detection of trace metals Electrochemistry Communications 13 2011 391 395
    • (2011) Electrochemistry Communications , vol.13 , pp. 391-395
    • Kokkinos, C.1    Economou, A.2    Raptis, I.3    Speliotis, T.4
  • 5
    • 80052341295 scopus 로고    scopus 로고
    • Electroanalytical detection of Pb, Cd and traces of Cr at micro/nano-structured bismuth film electrodes
    • J. Saturno, D. Valera, H. Carrero, and L. Fernández Electroanalytical detection of Pb, Cd and traces of Cr at micro/nano-structured bismuth film electrodes Sensors and Actuators B 159 2011 92 96
    • (2011) Sensors and Actuators B , vol.159 , pp. 92-96
    • Saturno, J.1    Valera, D.2    Carrero, H.3    Fernández, L.4
  • 6
    • 79960116561 scopus 로고    scopus 로고
    • Anodic stripping voltammetry combined with sequential injection analysis for measurements of trace metal ions with bismuth- and antimony film electrodes under comparable conditions
    • V. Guzsvány, H. Nakajima, N. Soh, K. Nakano, I. Švancara, and K. Vytřas Anodic stripping voltammetry combined with sequential injection analysis for measurements of trace metal ions with bismuth- and antimony film electrodes under comparable conditions Electroanalysis 23 2011 1593 1601
    • (2011) Electroanalysis , vol.23 , pp. 1593-1601
    • Guzsvány, V.1    Nakajima, H.2    Soh, N.3    Nakano, K.4    Švancara, I.5    Vytřas, K.6
  • 7
    • 56249111620 scopus 로고    scopus 로고
    • Square-wave voltammetric determination of thallium using surface modified thick-film graphite electrode with Bi nanopowder
    • G.-J. Lee, H.M. Lee, Y.R. Uhm, M.K. Lee, and C.-K. Rhee Square-wave voltammetric determination of thallium using surface modified thick-film graphite electrode with Bi nanopowder Electrochemistry Communications 10 2008 1920 1923
    • (2008) Electrochemistry Communications , vol.10 , pp. 1920-1923
    • Lee, G.-J.1    Lee, H.M.2    Uhm, Y.R.3    Lee, M.K.4    Rhee, C.-K.5
  • 8
    • 27144435519 scopus 로고    scopus 로고
    • Novel electrode for electrochemical stripping analysis based on carbon paste modified with bismuth powder
    • DOI 10.1016/j.electacta.2005.05.023, PII S0013468605005049
    • S.B. Hocevar, I. Svancara, K. Vytras, and B. Ogorevc Novel electrode for electrochemical stripping analysis based on carbon paste modified with bismuth powder Electrochimica Acta 51 2005 706 710 (Pubitemid 41500060)
    • (2005) Electrochimica Acta , vol.51 , Issue.4 , pp. 706-710
    • Hocevar, S.B.1    Svancara, I.2    Vytras, K.3    Ogorevc, B.4
  • 9
    • 34548617820 scopus 로고    scopus 로고
    • Bismuth nano-powder electrode for trace analysis of heavy metals using anodic stripping voltammetry
    • DOI 10.1016/j.elecom.2007.07.030, PII S1388248107003165
    • G.-J. Lee, H.-M. Lee, and C.-K. Rhee Bismuth nano-powder electrode for trace analysis of heavy metals using anodic stripping voltammetry Electrochemistry Communications 9 2007 2514 2518 (Pubitemid 47405286)
    • (2007) Electrochemistry Communications , vol.9 , Issue.10 , pp. 2514-2518
    • Lee, G.-J.1    Lee, H.-M.2    Rhee, C.-K.3
  • 11
    • 0036947802 scopus 로고    scopus 로고
    • A study on operational parameters for advanced use of bismuth film electrode in anodic stripping voltammetry
    • S.B. Hočevar, B. Ogorevc, J. Wang, and B. Pihlar A study on operational parameters for advanced use of bismuth film electrode in anodic stripping voltammetry Electroanalysis 14 2002 1707 1712
    • (2002) Electroanalysis , vol.14 , pp. 1707-1712
    • Hočevar, S.B.1    Ogorevc, B.2    Wang, J.3    Pihlar, B.4
  • 13
    • 58149154816 scopus 로고    scopus 로고
    • Direct electron transfer of Horseradish peroxidase on porous structure of screen-printed electrode
    • Y. Teng, S. Zuo, and M. Lan Direct electron transfer of Horseradish peroxidase on porous structure of screen-printed electrode Biosensors and Bioelectronics 24 2009 1353 1357
    • (2009) Biosensors and Bioelectronics , vol.24 , pp. 1353-1357
    • Teng, Y.1    Zuo, S.2    Lan, M.3
  • 16
  • 17
    • 36448937502 scopus 로고    scopus 로고
    • Antimony film electrode for electrochemical stripping analysis
    • DOI 10.1021/ac070478m
    • S.B. Hocevar, I. Švancara, B. Ogorevc, and K. Vytřas Antimony film electrode for electrochemical stripping analysis Analytical Chemistry 79 2007 8639 8643 (Pubitemid 350171374)
    • (2007) Analytical Chemistry , vol.79 , Issue.22 , pp. 8639-8643
    • Hocevar, S.B.1    Svancara, I.2    Ogorevc, B.3    Vytras, K.4
  • 18
    • 79957696684 scopus 로고    scopus 로고
    • Simultaneous determination of ultratrace lead and cadmium by square wave stripping voltammetry with in situ depositing bismuth at Nafion-medical stone doped disposable electrode
    • H. Li, J. Li, Z. Yang, Q. Xu, C. Hou, J. Peng, and X. Hu Simultaneous determination of ultratrace lead and cadmium by square wave stripping voltammetry with in situ depositing bismuth at Nafion-medical stone doped disposable electrode Journal of Hazardous Materials 191 2011 26 31
    • (2011) Journal of Hazardous Materials , vol.191 , pp. 26-31
    • Li, H.1    Li, J.2    Yang, Z.3    Xu, Q.4    Hou, C.5    Peng, J.6    Hu, X.7
  • 19
    • 84862792988 scopus 로고    scopus 로고
    • Determination of cadmium(II) by square wave anodic stripping voltammetry using bismuth-antimony film electrode
    • W. Yi, Y. Li, G. Ran, H. Luo, and N. Li Determination of cadmium(II) by square wave anodic stripping voltammetry using bismuth-antimony film electrode Sensors and Actuators B 166-167 2012 544 548
    • (2012) Sensors and Actuators B , vol.166-167 , pp. 544-548
    • Yi, W.1    Li, Y.2    Ran, G.3    Luo, H.4    Li, N.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.