메뉴 건너뛰기




Volumn , Issue , 2012, Pages 2089-2095

Measurement of the physical PSF for an integrated PET/MR using targeted positron beams

Author keywords

[No Author keywords available]

Indexed keywords

HIGH SPATIAL RESOLUTION; HYPER-RESOLUTION; NUMBER OF ITERATIONS; POINT-SPREAD FUNCTION; PRECISE MEASUREMENTS; RADIAL COMPONENT; RADIOACTIVE SOURCES; SUPPRESSION OF NOISE;

EID: 84872734821     PISSN: 10957863     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/NSSMIC.2012.6551480     Document Type: Conference Paper
Times cited : (7)

References (8)
  • 1
    • 84872723047 scopus 로고    scopus 로고
    • Physics and applications of positron beams in an integrated PETIMR
    • submitted
    • C. C. Watson, L. Eriksson, and A. Kolb, "Physics and applications of positron beams in an integrated PETIMR," Phys. Med. Biol., 2012, submitted.
    • (2012) Phys. Med. Biol.
    • Watson, C.C.1    Eriksson, L.2    Kolb, A.3
  • 2
    • 0026837927 scopus 로고
    • A simple method for determining the modulation transfer function in digital radiography
    • Mar.
    • H. Fujita, D.-Y. Tsai, T. Itoh, K. Doi, J. Morishita, K. Ueda, and A. Ohtsuka, "A simple method for determining the modulation transfer function in digital radiography," IEEE Trans. Med. Img., Vol. 11, no. 1, pp. 34-39, Mar. 1992.
    • (1992) IEEE Trans. Med. Img. , vol.11 , Issue.1 , pp. 34-39
    • Fujita, H.1    Tsai, D.-Y.2    Itoh, T.3    Doi, K.4    Morishita, J.5    Ueda, K.6    Ohtsuka, A.7
  • 3
    • 84858637982 scopus 로고    scopus 로고
    • Estimating effective model kernel widths for PSF reconstruction in PET
    • M8-6
    • c. c. Watson, "Estimating effective model kernel widths for PSF reconstruction in PET," 2011 IEEE Nucl. Sci Symp. Conf. Rec, 2011, M8-6.
    • (2011) 2011 IEEE Nucl. Sci Symp. Conf. Rec
    • Watson, C.C.1
  • 4
    • 0023422273 scopus 로고
    • Noise and edge artifacts in maximum-likelihood reconstructions for emission tomography
    • Sep.
    • D. L. Snyder, M. l. Miller, J. Lewis J. Thomas, and D. G. Politte, "Noise and edge artifacts in maximum-likelihood reconstructions for emission tomography," IEEE Trans. Med. Img., Vol. MI-6, no. 3, pp. 228-238, Sep. 1987.
    • (1987) IEEE Trans. Med. Img. , vol.MI-6 , Issue.3 , pp. 228-238
    • Snyder, D.L.1    Miller, M.J.2    Lewis, J.3    Thomas, J.4    Politte, D.G.5
  • 5
    • 70149107292 scopus 로고    scopus 로고
    • Iterative image reconstruction for positron emission tomography based on detector response function estimated from point source measurements
    • Jun.
    • M. S. Tohme and J. Qi, "Iterative image reconstruction for positron emission tomography based on detector response function estimated from point source measurements," Phys. Med. Biol., Vol. 54, no. 12, pp. 3709-3725, Jun. 2009.
    • (2009) Phys. Med. Biol. , vol.54 , Issue.12 , pp. 3709-3725
    • Tohme, M.S.1    Qi, J.2
  • 6
    • 33746191812 scopus 로고    scopus 로고
    • Fully 3-D PET reconstruction with system matrix derived from point source measurements
    • Jul.
    • Y Y Panin, F. Kehren, C. Michel, and M. E. Casey, "Fully 3-D PET reconstruction with system matrix derived from point source measurements," IEEE Trans. Med. Img., Vol. 25, no. 7, pp. 907-921, Jul. 2006.
    • (2006) IEEE Trans. Med. Img. , vol.25 , Issue.7 , pp. 907-921
    • Panin, Y.Y.1    Kehren, F.2    Michel, C.3    Casey, M.E.4
  • 7
    • 84881605639 scopus 로고    scopus 로고
    • Y Y Panin and H. Rothfuss, 2012, private communication
    • Y Y Panin and H. Rothfuss, 2012, private communication.
  • 8
    • 0033059817 scopus 로고    scopus 로고
    • Calculation of positron range and its effect on the fundamental limit of positron emission tomography system spatial resolution
    • C. S. Levin and E. J. Hoffman, "Calculation of positron range and its effect on the fundamental limit of positron emission tomography system spatial resolution," Phys. Med. Biol., Vol. 44, pp. 781-799, 1999.
    • (1999) Phys. Med. Biol. , vol.44 , pp. 781-799
    • Levin, C.S.1    Hoffman, E.J.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.