메뉴 건너뛰기




Volumn 110, Issue 2, 2013, Pages 201-206

Left ventricular volume and ejection fraction assessment with transoesophageal echocardiography: 2D vs 3D imaging

Author keywords

2D echocardiography; 3D echocardiography; cardiac surgery; echocardiography, transoesophageal

Indexed keywords

ADULT; AGED; ARTICLE; CARDIAC PATIENT; CLINICAL ASSESSMENT; CONTROLLED STUDY; FEMALE; HEART EJECTION FRACTION; HEART LEFT VENTRICLE ENDDIASTOLIC VOLUME; HEART LEFT VENTRICLE VOLUME; HEART SURGERY; HUMAN; INTERMETHOD COMPARISON; INTERRATER RELIABILITY; INTRARATER RELIABILITY; MAJOR CLINICAL STUDY; MALE; MEIBOMIAN GLAND; PRIORITY JOURNAL; REAL TIME ECHOGRAPHY; REPRODUCIBILITY; STANDARD; STATISTICAL SIGNIFICANCE; SURGICAL PATIENT; THREE DIMENSIONAL ECHOCARDIOGRAPHY; TRANSESOPHAGEAL ECHOCARDIOGRAPHY; TWO DIMENSIONAL ECHOCARDIOGRAPHY; VALIDATION PROCESS;

EID: 84872719045     PISSN: 00070912     EISSN: 14716771     Source Type: Journal    
DOI: 10.1093/bja/aes350     Document Type: Article
Times cited : (18)

References (12)
  • 2
    • 77952480402 scopus 로고    scopus 로고
    • Perioperative monitoring of left ventricular function what is the role of recent developments in echocardiography?
    • Ng A, Swanevelder J. Perioperative monitoring of left ventricular function: What is the role of recent developments in echocardiography?Br J Anaesth 2010; 104: 669-72
    • (2010) Br J Anaesth , vol.104 , pp. 669-672
    • Ng, A.1    Swanevelder, J.2
  • 3
    • 77953202133 scopus 로고    scopus 로고
    • Core review: Three-dimensional transesophageal echocardiography is a major advance for intraoperative clinical management of patients undergoing cardiac surgery: A core review
    • Vegas A, Meineri M. Core review: Three-dimensional transesophageal echocardiography is a major advance for intraoperative clinical management of patients undergoing cardiac surgery: A core review. Anesth Analg 2010; 110: 1548-73
    • (2010) Anesth Analg , vol.110 , pp. 1548-1573
    • Vegas, A.1    Meineri, M.2
  • 4
    • 29644445829 scopus 로고    scopus 로고
    • Role of real time 3D echocardiography in evaluating the left ventricle
    • DOI 10.1136/hrt.2004.058388
    • Monaghan MJ. Role of real time 3D echocardiography in evaluating the left ventricle. Heart 2006; 92: 131-6 (Pubitemid 43021881)
    • (2006) Heart , vol.92 , Issue.1 , pp. 131-136
    • Monaghan, M.J.1
  • 5
    • 33847251987 scopus 로고    scopus 로고
    • 3D echocardiography: A review of the current status and future directions
    • Hung J, Lang R, Flachskampf F, et al. 3D echocardiography: A review of the current status and future directions. J Am Soc Echocardiogr 2007; 20: 213-33
    • (2007) J Am Soc Echocardiogr , vol.20 , pp. 213-233
    • Hung, J.1    Lang, R.2    Flachskampf, F.3
  • 8
    • 41149156955 scopus 로고    scopus 로고
    • Feasibility and clinical decision-making with 3D echocardiography in routine practice
    • DOI 10.1136/hrt.2007.123570
    • Hare JL, Jenkins C, Nakatani S, Ogawa A, Yu CM, Marwick TH. Feasibility and clinical decision-Making with 3D echocardiography in routine practice. Heart 2008; 94: 440-5 (Pubitemid 351441397)
    • (2008) Heart , vol.94 , Issue.4 , pp. 440-445
    • Hare, J.L.1    Jenkins, C.2    Nakatani, S.3    Ogawa, A.4    Yu, C.-M.5    Marwick, T.H.6
  • 10
    • 58149171451 scopus 로고    scopus 로고
    • Left ventricular volume measurement with echocardiography: A comparison of left ventricular opacification, three-dimensional echocardiography, or both with magnetic resonance imaging
    • Jenkins C, Moir S, Chan J, Rakhit D, Haluska B, Marwick TH. Left ventricular volume measurement with echocardiography: A comparison of left ventricular opacification, three-dimensional echocardiography, or both with magnetic resonance imaging. Eur Heart J 2009; 30: 98-106
    • (2009) Eur Heart J , vol.30 , pp. 98-106
    • Jenkins, C.1    Moir, S.2    Chan, J.3    Rakhit, D.4    Haluska, B.5    Marwick, T.H.6
  • 11
    • 4143108001 scopus 로고    scopus 로고
    • Reproducibility and accuracy of echocardiographic measurements of left ventricular parameters using real-time three-dimensional echocardiography
    • DOI 10.1016/j.jacc.2004.05.050, PII S0735109704011179
    • Jenkins C, Bricknell K, Hanekom L, Marwick TH. Reproducibility and accuracy of echocardiographic measurements of left ventricular parameters using real-Time three-dimensional echocardiography. J Am Coll Cardiol 2004; 44: 878-86 (Pubitemid 39099588)
    • (2004) Journal of the American College of Cardiology , vol.44 , Issue.4 , pp. 878-886
    • Jenkins, C.1    Bricknell, K.2    Hanekom, L.3    Marwick, T.H.4
  • 12
    • 0000540770 scopus 로고    scopus 로고
    • Real-Time three-dimensional echocardiographic study of left ventricular function after infarct exclusion surgery for ischemic cardiomyopathy
    • III101-6
    • Qin JX, Shiota T, McCarthy PM, et al. Real-Time three-dimensional echocardiographic study of left ventricular function after infarct exclusion surgery for ischemic cardiomyopathy. Circulation 2000; 102(Suppl. 3): III101-6
    • (2000) Circulation , vol.102 , Issue.SUPPL. 3
    • Qin, J.X.1    Shiota, T.2    McCarthy, P.M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.