메뉴 건너뛰기




Volumn 31, Issue 1, 2013, Pages 113-118

Real-time near-body drug screening during autopsy I: Use of the Randox biochip drugs of abuse DOA i and DOA II immunoassays

Author keywords

Drugs of abuse; Immunoassay; Liver; Muscle; Postmortem; Vitreous humor

Indexed keywords

3,4 METHYLENEDIOXYMETHAMPHETAMINE; AMPHETAMINE; BARBITURIC ACID DERIVATIVE; BENZODIAZEPINE; BENZOYLECGONINE; BUPRENORPHINE; CANNABINOID; DEXTROPROPOXYPHENE; DIETHYLAMINE; FENTANYL; KETAMINE; LYSERGIC ACID; METHADONE; METHAMPHETAMINE; METHAQUALONE; OPIATE; OXYCODONE; PHENCYCLIDINE;

EID: 84872686529     PISSN: 18608965     EISSN: 18608973     Source Type: Journal    
DOI: 10.1007/s11419-012-0149-2     Document Type: Conference Paper
Times cited : (11)

References (18)
  • 1
    • 37549009899 scopus 로고    scopus 로고
    • Urine drug screening: Practical guide for clinicians
    • 10.4065/83.1.66
    • Moeller KE, Lee KC, Kissack JC (2008) Urine drug screening: practical guide for clinicians. Mayo Clin Proc 86:66-76
    • (2008) Mayo Clin Proc , vol.86 , pp. 66-76
    • Moeller, K.E.1    Lee, K.C.2    Kissack, J.C.3
  • 2
    • 37649022048 scopus 로고    scopus 로고
    • The U.S. mandatory guidelines for federal workplace drug testing programs: Current status and future considerations
    • 17434274 10.1016/j.forsciint.2007.03.008
    • Bush DM (2007) The U.S. mandatory guidelines for federal workplace drug testing programs: current status and future considerations. Forensic Sci Int 174:111-119
    • (2007) Forensic Sci Int , vol.174 , pp. 111-119
    • Bush, D.M.1
  • 3
    • 76149092860 scopus 로고    scopus 로고
    • Protocol for accuracy of point of care (POC) or in-office urine drug testing (immunoassay) in chronic pain patients: A prospective analysis of immunoassay and liquid chromatography tandem mass spectrometry (LC/MS/MS)
    • Manchikanti L, Malla Y, Wargo BW, Cash KA, Pampati V, Damron KS, McCanus CD, Brandon DE (2010) Protocol for accuracy of point of care (POC) or in-office urine drug testing (immunoassay) in chronic pain patients: a prospective analysis of immunoassay and liquid chromatography tandem mass spectrometry (LC/MS/MS). Pain Phys 13:1-22
    • (2010) Pain Phys , vol.13 , pp. 1-22
    • Manchikanti, L.1    Malla, Y.2    Wargo, B.W.3    Cash, K.A.4    Pampati, V.5    Damron, K.S.6    McCanus, C.D.7    Brandon, D.E.8
  • 5
    • 80052701177 scopus 로고    scopus 로고
    • Perceptions of near virtual autopsies
    • 21907933 10.1016/j.jflm.2011.06.006
    • Rutty GN, Rutty JE (2011) Perceptions of near virtual autopsies. J Forensic Leg Med 18:306-309
    • (2011) J Forensic Leg Med , vol.18 , pp. 306-309
    • Rutty, G.N.1    Rutty, J.E.2
  • 6
    • 33847238467 scopus 로고    scopus 로고
    • Are autopsies necessary? the role of computed tomography as a possible alternative to invasive autopsies
    • 10.1007/s00194-006-0408-9
    • Rutty GN (2007) Are autopsies necessary? The role of computed tomography as a possible alternative to invasive autopsies. Rechtsmedizine 17:21-28
    • (2007) Rechtsmedizine , vol.17 , pp. 21-28
    • Rutty, G.N.1
  • 7
    • 68349098967 scopus 로고    scopus 로고
    • Application of the Cozart DDS system to postmortem screening of drugs of abuse in vitreous humor
    • 10.1007/s11419-009-0071-4 1:CAS:528:DC%2BD1MXos1Cgs7g%3D
    • Fernandez AA, Amigo N, Carbone MT, Mora A, Pinto M, Beltran J, Gasso S (2009) Application of the Cozart DDS system to postmortem screening of drugs of abuse in vitreous humor. Forensic Toxicol 27:90-97
    • (2009) Forensic Toxicol , vol.27 , pp. 90-97
    • Fernandez, A.A.1    Amigo, N.2    Carbone, M.T.3    Mora, A.4    Pinto, M.5    Beltran, J.6    Gasso, S.7
  • 8
    • 0031877305 scopus 로고
    • Applications of an HPLC-DAD drug screening system based on retention indices and UV spectra
    • Elliott SP, Hale KA (1988) Applications of an HPLC-DAD drug screening system based on retention indices and UV spectra. J Anal Toxicol 22:280-290
    • (1988) J Anal Toxicol , vol.22 , pp. 280-290
    • Elliott, S.P.1    Hale, K.A.2
  • 9
    • 77950361130 scopus 로고    scopus 로고
    • Identification and quantitation of amphetamine, methamphetamine, MDMA, pseudophedrine, and ephedrine in blood, plasma, and serum using gas chromatography-mass spectrometry (GC/MS)
    • 10.1007/978-1-60761-459-3-4 1:CAS:528:DC%2BC3cXnt12ks78%3D
    • Gunn J, Kriger S, Terrell AR (2010) Identification and quantitation of amphetamine, methamphetamine, MDMA, pseudophedrine, and ephedrine in blood, plasma, and serum using gas chromatography-mass spectrometry (GC/MS). Clin Appl Mass Spectrom 603:37-43
    • (2010) Clin Appl Mass Spectrom , vol.603 , pp. 37-43
    • Gunn, J.1    Kriger, S.2    Terrell, A.R.3
  • 10
    • 43049176789 scopus 로고    scopus 로고
    • Phencyclidine and cannabinoids in vitreous humor
    • 10.1016/j.legalmed.2008.01.002 1:CAS:528:DC%2BD1cXlvVWhtrk%3D
    • Jenkins AJ, Oblock J (2008) Phencyclidine and cannabinoids in vitreous humor. Leg Med 10:201-203
    • (2008) Leg Med , vol.10 , pp. 201-203
    • Jenkins, A.J.1    Oblock, J.2
  • 11
    • 0034993161 scopus 로고    scopus 로고
    • The use of vitreous humor as an alternative to whole blood for the analysis of benzodiazepines
    • Scott KS, Oliver JS (2001) The use of vitreous humor as an alternative to whole blood for the analysis of benzodiazepines. J Forensic Sci 46:694-697 (Pubitemid 32520597)
    • (2001) Journal of Forensic Sciences , vol.46 , Issue.3 , pp. 694-697
    • Scott, K.S.1    Oliver, J.S.2
  • 12
    • 0031899535 scopus 로고    scopus 로고
    • Analytical confirmation of error in false positive amphetamine immunoassays and results
    • 9582976 1:STN:280:DyaK1c3ktlOqtQ%3D%3D
    • Schutz H, Erdmann F, Magiera ES, Weiler G (1998) Analytical confirmation of error in false positive amphetamine immunoassays and results. Arch Kriminol 201:93-96
    • (1998) Arch Kriminol , vol.201 , pp. 93-96
    • Schutz, H.1    Erdmann, F.2    Magiera, E.S.3    Weiler, G.4
  • 13
    • 0036825774 scopus 로고    scopus 로고
    • Choice of an ELISA assay for screening postmortem blood for amphetamine and/or methamphetamine
    • Kupiec T, DeCicco L, Spiehler V, Sneed G, Kemp P (2002) Choice of an ELISA assay for screening postmortem blood for amphetamine and/or methamphetamine. J Anal Toxicol 26:513-518 (Pubitemid 36206788)
    • (2002) Journal of Analytical Toxicology , vol.26 , Issue.7 , pp. 513-518
    • Kupiec, T.1    DeCicco, L.2    Spiehler, V.3    Sneed, G.4    Kemp, P.5
  • 14
    • 0037623886 scopus 로고    scopus 로고
    • Comparison and evaluation of DRI® methamphetamine, DRI ecstasy, abuscreen® ONLINE amphetamine, and a modified abuscreen ONLINE amphetamine screening immunoassays for the detection of amphetamine (AMP), methamphetamine (MTH), 3,4-methylenedioxyamphetamine (MDA), and 3,4- methylenedioxymethamphetamine (MDMA) in human urine
    • Stout PR, Klette KL, Wiegand R (2003) Comparison and evaluation of DRI methamphetamine, DRI ecstasy, Abuscreen ONLINE amphetamine, and a modified Abuscreen ONLINE amphetamine screening immunoassays for the detection of amphetamine (AMP), methamphetamine (MTH), 3,4-methylenedioxyamphetamine (MDA), and 3,4-methylenedioxymethamphetamine (MDMA) in human urine. J Anal Toxicol 27:265-269 (Pubitemid 36877168)
    • (2003) Journal of Analytical Toxicology , vol.27 , Issue.5 , pp. 265-269
    • Stout, P.R.1    Klette, K.L.2    Wiegand, R.3
  • 15
    • 4744344181 scopus 로고    scopus 로고
    • Diagnostic efficiency of different amphetamine screening tests - The search for an optimal cutoff
    • DOI 10.1515/CCLM.2004.213
    • Savoca R, Rentsch KM, Hubert AR (2004) Diagnostic efficiency of different amphetamine screening tests - the search for an optimal cutoff. Clin Chem Lab Med 42:1063-1065 (Pubitemid 39307399)
    • (2004) Clinical Chemistry and Laboratory Medicine , vol.42 , Issue.9 , pp. 1063-1065
    • Savoca, R.1    Rentsch, K.M.2    Huber, A.R.3
  • 16
    • 34248210037 scopus 로고    scopus 로고
    • Matrix effect and cross-reactivity of select amphetamine-type substances, designer analogues, and putrefactive amines using the bio-quant direct ELISA presumptive assays for amphetamine and methamphetamine
    • Apollonio LG, Whittall IR, Pianca DJ, Kyd JM, Maher WA (2007) Matrix effect and cross-reactivity of select amphetamine-type substances, designer analogues, and putrefactive amines using the Bio-Quant direct ELISA presumptive assays for amphetamine and methamphetamine. J Anal Toxicol 31:208-213 (Pubitemid 46708661)
    • (2007) Journal of Analytical Toxicology , vol.31 , Issue.4 , pp. 208-213
    • Apollonio, L.G.1    Whittall, I.R.2    Pianca, D.J.3    Kyd, J.M.4    Maher, W.A.5
  • 17
    • 84872685857 scopus 로고    scopus 로고
    • Interpretation of amphetamines screening and confirmation testing
    • Broussard L (2008) Interpretation of amphetamines screening and confirmation testing. Bioanalysis 1:937-952
    • (2008) Bioanalysis , vol.1 , pp. 937-952
    • Broussard, L.1
  • 18
    • 67349102253 scopus 로고    scopus 로고
    • ® Drug of Abuse Panel: The cause of the unusual phenomenon with experimental analyses
    • 10.1007/s00414-008-0304-9
    • ® Drug of Abuse Panel: the cause of the unusual phenomenon with experimental analyses. Int J Leg Med 123:247-252
    • (2009) Int J Leg Med , vol.123 , pp. 247-252
    • Hikiji, W.1    Kudo, K.2    Sato, S.3    Usumoto, Y.4    Tsuji, A.5    Ikeda, N.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.