메뉴 건너뛰기




Volumn 46, Issue 3, 2013, Pages 561-566

Mechanical response of animal abdominal walls in vitro: Evaluation of the influence of a hernia defect and a repair with a mesh implanted intraperitoneally

Author keywords

Biomechanics; Contact loading; Digital image correlation; Mesh repair; Pressure

Indexed keywords

AIR PRESSURES; CONTACT LOADING; DIGITAL IMAGE CORRELATIONS; EXTERNAL SURFACES; GLOBAL STIFFNESS; IN-VITRO; INTRAPERITONEAL; INTRAPERITONEALLY; LOCAL STRAIN FIELD; LOCAL STRAINS; MECHANICAL RESPONSE; MESH REPAIR;

EID: 84872613485     PISSN: 00219290     EISSN: 18732380     Source Type: Journal    
DOI: 10.1016/j.jbiomech.2012.09.014     Document Type: Article
Times cited : (35)

References (23)
  • 1
    • 34548118301 scopus 로고    scopus 로고
    • Biomechanical analyses of overlap and mesh dislocation in an incisional hernia model in vitro
    • Binnebösel M., Rosch R., Junge K., Flanagan T.C., Schwab R., Schumpelick V., Klinge U. Biomechanical analyses of overlap and mesh dislocation in an incisional hernia model in vitro. Surgery 2007, 142(3):365-371.
    • (2007) Surgery , vol.142 , Issue.3 , pp. 365-371
    • Binnebösel, M.1    Rosch, R.2    Junge, K.3    Flanagan, T.C.4    Schwab, R.5    Schumpelick, V.6    Klinge, U.7
  • 3
    • 1542646308 scopus 로고    scopus 로고
    • Incisional herniorrhaphy with intraperitoneal composite mesh: a report of 95 cases
    • Cobb W.S., Harris J.B., Lokey J.S., McGill E.S., Klove K.V. Incisional herniorrhaphy with intraperitoneal composite mesh: a report of 95 cases. American Surgeon 2003, 69(9):784-787.
    • (2003) American Surgeon , vol.69 , Issue.9 , pp. 784-787
    • Cobb, W.S.1    Harris, J.B.2    Lokey, J.S.3    McGill, E.S.4    Klove, K.V.5
  • 10
    • 33845625586 scopus 로고    scopus 로고
    • Measurement of the tensile strength of the ventral abdominal wall in comparison with scar tissue
    • Hollinsky C., Sandberg S. Measurement of the tensile strength of the ventral abdominal wall in comparison with scar tissue. Clinical Biomechanics 2007, 22(1):88-92.
    • (2007) Clinical Biomechanics , vol.22 , Issue.1 , pp. 88-92
    • Hollinsky, C.1    Sandberg, S.2
  • 11
    • 0034759309 scopus 로고    scopus 로고
    • Elasticity of the anterior abdominal wall and impact for reparation of incisional hernias using mesh implants
    • Junge K., Klinge U., Prescher A., Giboni P., Niewiera M., Schumpelick V. Elasticity of the anterior abdominal wall and impact for reparation of incisional hernias using mesh implants. Hernia 2001, 5(3):113-118.
    • (2001) Hernia , vol.5 , Issue.3 , pp. 113-118
    • Junge, K.1    Klinge, U.2    Prescher, A.3    Giboni, P.4    Niewiera, M.5    Schumpelick, V.6
  • 12
    • 0001834414 scopus 로고    scopus 로고
    • Application of three-dimensional stereography to assess abdominal wall mobility
    • Klinge U., Muller M., Brucker C., Schumpelick V. Application of three-dimensional stereography to assess abdominal wall mobility. Hernia 1998, 2:11-14.
    • (1998) Hernia , vol.2 , pp. 11-14
    • Klinge, U.1    Muller, M.2    Brucker, C.3    Schumpelick, V.4
  • 14
    • 84864564028 scopus 로고    scopus 로고
    • Biomechanical and histological evaluation of abdominal wall compliance with intraperitoneal onlay mesh implants in rabbits: a comparison of six different state-of-the-art meshes
    • Konerding M.A., Chantereau P., Delventhal V., Holste J.L., Ackermann M. Biomechanical and histological evaluation of abdominal wall compliance with intraperitoneal onlay mesh implants in rabbits: a comparison of six different state-of-the-art meshes. Medical Engineering and Physics 2012, 34(7):806-816.
    • (2012) Medical Engineering and Physics , vol.34 , Issue.7 , pp. 806-816
    • Konerding, M.A.1    Chantereau, P.2    Delventhal, V.3    Holste, J.L.4    Ackermann, M.5
  • 16
    • 0000460856 scopus 로고    scopus 로고
    • Abdominal wall compliance after Marlex mesh implantation for incisional hernia repair
    • Müller M., Klinge U., Conze J., Schumpelick V. Abdominal wall compliance after Marlex mesh implantation for incisional hernia repair. Hernia 1998, 2:113-117.
    • (1998) Hernia , vol.2 , pp. 113-117
    • Müller, M.1    Klinge, U.2    Conze, J.3    Schumpelick, V.4
  • 18
    • 34250165786 scopus 로고    scopus 로고
    • Biomechanical properties of vaginal tissue. Part 1: new experimental protocol
    • Rubod C., Boukerrou M., Brieu M., Dubois P., Cosson M. Biomechanical properties of vaginal tissue. Part 1: new experimental protocol. Journal of Urology 2007, 178(1):320-325.
    • (2007) Journal of Urology , vol.178 , Issue.1 , pp. 320-325
    • Rubod, C.1    Boukerrou, M.2    Brieu, M.3    Dubois, P.4    Cosson, M.5
  • 22
    • 84856410937 scopus 로고    scopus 로고
    • Investigation of abdomen surface deformation due to life excitation: Implications for implant selection and orientation in laparoscopic ventral hernia repair
    • Szymczak C., Lubowiecka I., Tomaszewska A., Smietański M. Investigation of abdomen surface deformation due to life excitation: Implications for implant selection and orientation in laparoscopic ventral hernia repair. Clinical Biomechanics 2012, 27(2):105-110.
    • (2012) Clinical Biomechanics , vol.27 , Issue.2 , pp. 105-110
    • Szymczak, C.1    Lubowiecka, I.2    Tomaszewska, A.3    Smietański, M.4
  • 23
    • 0034143859 scopus 로고    scopus 로고
    • Quantifying skeletal muscle properties in cadaveric test specimens: effects of mechanical loading, postmortem time, and freezer storage
    • Van Ee C.A., Chasse A.L., Myers B.S. Quantifying skeletal muscle properties in cadaveric test specimens: effects of mechanical loading, postmortem time, and freezer storage. Journal of Biomechanical Engineering 2000, 122(1):9-14.
    • (2000) Journal of Biomechanical Engineering , vol.122 , Issue.1 , pp. 9-14
    • Van Ee, C.A.1    Chasse, A.L.2    Myers, B.S.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.