메뉴 건너뛰기




Volumn 46, Issue 3, 2013, Pages 567-573

Kinematic differences between optical motion capture and biplanar videoradiography during a jump-cut maneuver

Author keywords

Biomechanics; In vivo; Knee; Soft tissue artifact; X ray

Indexed keywords

ANATOMICAL COORDINATE SYSTEMS; BIPLANAR; CUTTING ACTIVITIES; GROUND CONTACTS; IN-VIVO; KNEE; KNEE JOINT KINEMATICS; KNEE KINEMATICS; MOTION CAPTURE; NON-CONTACT; OPTICAL MOTION CAPTURE; ROTATIONAL AXES; SOFT TISSUE ARTIFACTS; VIDEORADIOGRAPHY;

EID: 84872598483     PISSN: 00219290     EISSN: 18732380     Source Type: Journal    
DOI: 10.1016/j.jbiomech.2012.09.023     Document Type: Article
Times cited : (106)

References (30)
  • 1
    • 77951974556 scopus 로고    scopus 로고
    • Non-invasive assessment of soft-tissue artifact and its effect on knee joint kinematics during functional activity
    • Akbarshahi M., Schache A.G., Fernandez J.W., Baker R., Banks S., Pandy M.G. Non-invasive assessment of soft-tissue artifact and its effect on knee joint kinematics during functional activity. Journal of Biomechanics 2010, 43:1292-1301.
    • (2010) Journal of Biomechanics , vol.43 , pp. 1292-1301
    • Akbarshahi, M.1    Schache, A.G.2    Fernandez, J.W.3    Baker, R.4    Banks, S.5    Pandy, M.G.6
  • 5
    • 73149097417 scopus 로고    scopus 로고
    • Implications of using hierarchical and six degree-of-freedom models for normal gait analyses
    • Buczek F.L., Rainbow M.J., Cooney K.M., Walker M.R., Sanders J.O. Implications of using hierarchical and six degree-of-freedom models for normal gait analyses. Gait and Posture 2010, 31:57-63.
    • (2010) Gait and Posture , vol.31 , pp. 57-63
    • Buczek, F.L.1    Rainbow, M.J.2    Cooney, K.M.3    Walker, M.R.4    Sanders, J.O.5
  • 7
    • 0029310701 scopus 로고
    • A procedure for determining rigid body transformation parameters
    • Challis J.H. A procedure for determining rigid body transformation parameters. Journal of Biomechanics 1995, 28:733-737.
    • (1995) Journal of Biomechanics , vol.28 , pp. 733-737
    • Challis, J.H.1
  • 8
    • 0034308399 scopus 로고    scopus 로고
    • Segment inertial properties of Chinese adults determined from magnetic resonance imaging
    • Cheng C.-K., Chen H.-H., Chen C.-S., Lee C.-L., Chen C.-Y. Segment inertial properties of Chinese adults determined from magnetic resonance imaging. Clinical Biomechanics 2000, 15:559-566.
    • (2000) Clinical Biomechanics , vol.15 , pp. 559-566
    • Cheng, C.-K.1    Chen, H.-H.2    Chen, C.-S.3    Lee, C.-L.4    Chen, C.-Y.5
  • 14
    • 0020759032 scopus 로고
    • A joint coordinate system for the clinical description of three-dimensional motions: application to the knee
    • Grood E.S., Suntay W.J. A joint coordinate system for the clinical description of three-dimensional motions: application to the knee. Journal of Biomechanical Engineering 1983, 105:136-144.
    • (1983) Journal of Biomechanical Engineering , vol.105 , pp. 136-144
    • Grood, E.S.1    Suntay, W.J.2
  • 18
    • 0025690854 scopus 로고
    • Important features associated with acute anterior cruciate ligament injury
    • McNair P.J., Marshall R.N., Matheson J.A. Important features associated with acute anterior cruciate ligament injury. The New Zealand Medical Journal 1990, 103:537-539.
    • (1990) The New Zealand Medical Journal , vol.103 , pp. 537-539
    • McNair, P.J.1    Marshall, R.N.2    Matheson, J.A.3
  • 19
    • 77952584125 scopus 로고    scopus 로고
    • Automatic determination of anatomical coordinate systems for three-dimensional bone models of the isolated human knee
    • Miranda D.L., Rainbow M.J., Leventhal E.L., Crisco J.J., Fleming B.C. Automatic determination of anatomical coordinate systems for three-dimensional bone models of the isolated human knee. Journal of Biomechanics 2010, 43:1623-1626.
    • (2010) Journal of Biomechanics , vol.43 , pp. 1623-1626
    • Miranda, D.L.1    Rainbow, M.J.2    Leventhal, E.L.3    Crisco, J.J.4    Fleming, B.C.5
  • 25
    • 0027897660 scopus 로고
    • Determining the movements of the skeleton using well-configured markers
    • Söderkvist I., Wedin P.A. Determining the movements of the skeleton using well-configured markers. Journal of Biomechanics 1993, 26:1473-1477.
    • (1993) Journal of Biomechanics , vol.26 , pp. 1473-1477
    • Söderkvist, I.1    Wedin, P.A.2
  • 26
    • 0037396234 scopus 로고    scopus 로고
    • In-vivo measurement of dynamic joint motion using high speed biplane radiography and CT: application to canine ACL deficiency
    • Tashman S., Anderst W. In-vivo measurement of dynamic joint motion using high speed biplane radiography and CT: application to canine ACL deficiency. Journal of Biomechanical Engineering 2003, 125:238-245.
    • (2003) Journal of Biomechanical Engineering , vol.125 , pp. 238-245
    • Tashman, S.1    Anderst, W.2
  • 30
    • 79953016279 scopus 로고    scopus 로고
    • Effects of soft tissue artifacts on the calculated kinematics and kinetics of the knee during stair-ascent
    • Tsai T.-Y., Lu T.-W., Kuo M.-Y., Lin C.-C. Effects of soft tissue artifacts on the calculated kinematics and kinetics of the knee during stair-ascent. Journal of Biomechanics 2011, 44:1182-1188.
    • (2011) Journal of Biomechanics , vol.44 , pp. 1182-1188
    • Tsai, T.-Y.1    Lu, T.-W.2    Kuo, M.-Y.3    Lin, C.-C.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.