메뉴 건너뛰기




Volumn 38, Issue 6, 2012, Pages 747-750

Removal of fractured dental implant screw using a new technique: A case report

Author keywords

Dental implant; Osseointegration; Screw loosening

Indexed keywords

ADULT; ARTICLE; CASE REPORT; DENTAL SURGERY; DEVICE REMOVAL; HUMAN; INSTRUMENTATION; MALE; TOOTH IMPLANT; TOOTH PROSTHESIS;

EID: 84872509555     PISSN: 01606972     EISSN: 15481336     Source Type: Journal    
DOI: 10.1563/AAID-JOI-D-10-00195     Document Type: Article
Times cited : (30)

References (14)
  • 2
    • 39749137508 scopus 로고    scopus 로고
    • Retrieval of a fractured abutment screw thread from an implant: A case report
    • Satterthwaite J, Rickman L. Retrieval of a fractured abutment screw thread from an implant: a case report. Br Dent J. 2008;204:177-180.
    • (2008) Br Dent J , vol.204 , pp. 177-180
    • Satterthwaite, J.1    Rickman, L.2
  • 3
    • 0030236468 scopus 로고    scopus 로고
    • An analysis and management of fractured implants: A clinical report
    • Balshi TJ. An analysis and management of fractured implants: a clinical report. Int J Oral Maxillofac Implants. 1996;11: 660-666.
    • (1996) Int J Oral Maxillofac Implants , vol.11 , pp. 660-666
    • Balshi, T.J.1
  • 4
    • 2942551102 scopus 로고    scopus 로고
    • Removal of a fractured implant abutment screw: A clinical report
    • Nergiz I, Schmage P, Shahin R. Removal of a fractured implant abutment screw: a clinical report. J Prosthet Dent. 2004;91: 513-517.
    • (2004) J Prosthet Dent , vol.91 , pp. 513-517
    • Nergiz, I.1    Schmage, P.2    Shahin, R.3
  • 5
    • 0025471133 scopus 로고
    • The longitudinal clinical effectiveness of osseointegrated dental implants: The Toronto study. Part III: Problems and complications encountered
    • Zarb GA, Schmitt A. The longitudinal clinical effectiveness of osseointegrated dental implants: the Toronto study. Part III: problems and complications encountered. J Prosthet Dent. 1990;64: 185-194.
    • (1990) J Prosthet Dent , vol.64 , pp. 185-194
    • Zarb, G.A.1    Schmitt, A.2
  • 6
    • 35948932580 scopus 로고    scopus 로고
    • Technical complications of implant-supported fixed partial dentures in partially edentulous cases after an average observation period of 5 years
    • Kreissl ME, Gerds T, Muche R, Heydecke G, Strub Jr. Technical complications of implant-supported fixed partial dentures in partially edentulous cases after an average observation period of 5 years. Clin Oral Implants Res. 2007;18:720-726.
    • (2007) Clin Oral Implants Res , vol.18 , pp. 720-726
    • Kreissl, M.E.1    Gerds, T.2    Muche, R.3    Heydecke, G.4    Strub, J.R.5
  • 7
    • 0029262468 scopus 로고
    • Branemark single tooth implants: A preliminary report of 76 implants
    • Haas R, Mensdorff-Pouilly N, Mailath G, Watzek G. Branemark single tooth implants: a preliminary report of 76 implants. J Prosthet Dent. 1995;73:274-279.
    • (1995) J Prosthet Dent , vol.73 , pp. 274-279
    • Haas, R.1    Mensdorff-Pouilly, N.2    Mailath, G.3    Watzek, G.4
  • 8
    • 0036043045 scopus 로고    scopus 로고
    • Fracture of dental implants: Literature review and report of a case
    • Green NT, Machtei EE, Horwitz J, Peled M. Fracture of dental implants: literature review and report of a case. Implant Dent. 2002;11:137-143.
    • (2002) Implant Dent , vol.11 , pp. 137-143
    • Green, N.T.1    MacHtei, E.E.2    Horwitz, J.3    Peled, M.4
  • 9
    • 0034268455 scopus 로고    scopus 로고
    • Analysis of incidence and associated factors with fractured implants: A retrospective study
    • Eckert SE, Meraw SJ, Cal E, Ow RK. Analysis of incidence and associated factors with fractured implants: a retrospective study. Int J Oral Maxillofac Implants. 2000;15:662-667.
    • (2000) Int J Oral Maxillofac Implants , vol.15 , pp. 662-667
    • Eckert, S.E.1    Meraw, S.J.2    Cal, E.3    Ow, R.K.4
  • 10
    • 0033630481 scopus 로고    scopus 로고
    • Biomaterials and biomechanics of oral and maxillofacial implants: Current status and future developments
    • Brunski JB, Puleo DA, Nanci A. Biomaterials and biomechanics of oral and maxillofacial implants: current status and future developments. Int J Oral Maxillofac Implants. 2000;15:15-46.
    • (2000) Int J Oral Maxillofac Implants , vol.15 , pp. 15-46
    • Brunski, J.B.1    Puleo, D.A.2    Nanci, A.3
  • 11
    • 0029303075 scopus 로고
    • Occlusal force and oral tactile sensibility measured in partially edentulous patients with ITI implants
    • Mericske SR, Assal P, Mericske E, Burgin W. Occlusal force and oral tactile sensibility measured in partially edentulous patients with ITI implants. Int J Oral Maxillofac Implants. 1995;10:345-354.
    • (1995) Int J Oral Maxillofac Implants , vol.10 , pp. 345-354
    • Mericske, S.R.1    Assal, P.2    Mericske, E.3    Burgin, W.4
  • 12
    • 0031296495 scopus 로고    scopus 로고
    • Comparison of strength and failure mode of seven implant systems: An in vitro test
    • Mollersten L, Lockowandt P, Linden LA. Comparison of strength and failure mode of seven implant systems: an in vitro test. J Prosthet Dent. 1997;78:582-591.
    • (1997) J Prosthet Dent , vol.78 , pp. 582-591
    • Mollersten, L.1    Lockowandt, P.2    Linden, L.A.3
  • 14
    • 77957297984 scopus 로고    scopus 로고
    • Retrieval of a stripped abutment screw: A clinical report
    • Maalhagh-Fard A, Jacobs LC. Retrieval of a stripped abutment screw: a clinical report. J Prosthet Dent. 2010;104:212-215.
    • (2010) J Prosthet Dent , vol.104 , pp. 212-215
    • Maalhagh-Fard, A.1    Jacobs, L.C.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.