-
2
-
-
84872372831
-
Hypothalamic pituitary gonadal axis function in men with type 2 diabetes mellitus
-
Knoblovits P, Suárez SM, Scaglia HE, Zylbersztein CC, Litwak LE, Costanzo PR. Hypothalamic pituitary gonadal axis function in men with type 2 diabetes mellitus. Annual Meeting of Endocrine Society. P3-218, 2011
-
(2011)
Annual Meeting of Endocrine Society
, pp. 3-218
-
-
Knoblovits, P.1
Suárez, S.M.2
Scaglia, H.E.3
Zylbersztein, C.C.4
Litwak, L.E.5
Costanzo, P.R.6
-
3
-
-
0024340648
-
Prevention of the transient adverse effects of a gonadotropin-releasing hormone analogue (buserelin) in metastatic prostatic carcinoma by administration of an antioandrogen (nilutamide)
-
Kuhn JM, Billebaud T, Navratil H, Moulonguet A, Fiet J, Grise P, Louis J-F, Costa P, Husson L-M, Dahan R, Bertagna C, Edelstein R. Prevention of the transient adverse effects of a gonadotropin-releasing hormone analogue (buserelin) in metastatic prostatic carcinoma by administration of an antioandrogen (nilutamide). N Engl J Med 321:413-418, 1989
-
(1989)
N Engl J Med
, vol.321
, pp. 413-418
-
-
Kuhn, J.M.1
Billebaud, T.2
Navratil, H.3
Moulonguet, A.4
Fiet, J.5
Grise, P.6
Louis, J.-F.7
Costa, P.8
Husson, L.-M.9
Dahan, R.10
Bertagna, C.11
Edelstein, R.12
-
5
-
-
1442303475
-
Androgen excess in women: Experience with over 1000 consecutive patients
-
Azzis R, Sanchez LA, Knochenhauer ES, Moran C, Lazenby J, Stephens KC, Taylor K, Boots LR. Androgen excess in women: experience with over 1000 consecutive patients J Clin Endocrinol Metab 89: 453-462, 2004
-
(2004)
J Clin Endocrinol Metab
, vol.89
, pp. 453-462
-
-
Azzis, R.1
Sanchez, L.A.2
Knochenhauer, E.S.3
Moran, C.4
Lazenby, J.5
Stephens, K.C.6
Taylor, K.7
Boots, L.R.8
-
6
-
-
0001217801
-
Diagnostic criteria for polycystic ovary syndrome: Toward a rational approach
-
Dunaif A, Givens JR, Haseltine FP, Merriam GR, eds. Boston: Blackwell Scientific
-
Zawadski JK, Dunaif A. Diagnostic criteria for polycystic ovary syndrome: Toward a rational approach. In Dunaif A, Givens JR, Haseltine FP, Merriam GR, eds. Polycystic Ovary Syndrome, Boston: Blackwell Scientific, 377-384, 1992
-
(1992)
Polycystic Ovary Syndrome
, pp. 377-384
-
-
Zawadski, J.K.1
Dunaif, A.2
-
7
-
-
2442462758
-
Revised 2003 consensus on diagnostic criteria and long term health risks to PCOS
-
The Rötterdam ESHRE/ASRM- sposored PCOS consensus workshop group
-
The Rötterdam ESHRE/ASRM- sposored PCOS consensus workshop group. Revised 2003 consensus on diagnostic criteria and long term health risks to PCOS. Hum Reprod 19: 41-47, 2004
-
(2004)
Hum Reprod
, vol.19
, pp. 41-47
-
-
-
8
-
-
59349098805
-
The Androgen Excess and PCOS Society criteria for the POCS: The complete task force report
-
Azziz R, Carmina E, Dewailly D, Diamanti-Kandarakis E, Escobar-Morreale HF, Futterweit W, Janssen OE, Legro RS,Norman RJ, Taylor AE, Witchel SF. The Androgen Excess and PCOS Society criteria for the POCS: the complete task force report. Fert Steril 91: 456-488, 2009
-
(2009)
Fert Steril
, vol.91
, pp. 456-488
-
-
Azziz, R.1
Carmina, E.2
Dewailly, D.3
Diamanti-Kandarakis, E.4
Escobar-Morreale, H.F.5
Futterweit, W.6
Janssen, O.E.7
Legro, R.S.8
Norman, R.J.9
Taylor, A.E.10
Witchel, S.F.11
-
9
-
-
33846991956
-
Position Statement: Utility, limitations and pitfalls in measuring testosterone; An Endocrine Society position statement
-
Rosner W, Auchus RJ, Azziz R, Sluss PM, Raff H. Position Statement: Utility, limitations and pitfalls in measuring testosterone; An Endocrine Society position statement. J Clin Endocrinol Metab 92:405-413, 2007
-
(2007)
J Clin Endocrinol Metab
, vol.92
, pp. 405-413
-
-
Rosner, W.1
Auchus, R.J.2
Azziz, R.3
Sluss, P.M.4
Raff, H.5
-
10
-
-
12644305063
-
Clinical assessment of body hair growth in women
-
Ferriman D, Gallwey JD. Clinical assessment of body hair growth in women J Clin Endocrinol Metab 21:1440-1447, 1961
-
(1961)
J Clin Endocrinol Metab
, vol.21
, pp. 1440-1447
-
-
Ferriman, D.1
Gallwey, J.D.2
-
12
-
-
84908219488
-
Statistical methods for assessing agreement between two methods of clinical measurement
-
Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1:307-310, 1986
-
(1986)
Lancet
, vol.1
, pp. 307-310
-
-
Bland, J.M.1
Altman, D.G.2
-
13
-
-
0032999776
-
Neccesary sample sixe for method comparison studies based on regression analysis
-
Linnet K. Neccesary sample sixe for method comparison studies based on regression analysis. Clin Chem. 45:882-894, 1999
-
(1999)
Clin Chem.
, vol.45
, pp. 882-894
-
-
Linnet, K.1
-
14
-
-
0036375971
-
Generic serial and parallel on-line direct - Injection using turbulent flow liquid chromatography/tandem mass spectrometry
-
Grant RP, Cameron C, Mackenzie-McMurter S. Generic serial and parallel on-line direct - injection using turbulent flow liquid chromatography/tandem mass spectrometry. Rapid Commun Mass Spectrom. 16:1785-1792, 2002
-
(2002)
Rapid Commun Mass Spectrom.
, vol.16
, pp. 1785-1792
-
-
Grant, R.P.1
Cameron, C.2
Mackenzie-McMurter, S.3
-
15
-
-
0031906157
-
Measurement of total serum testosterone levels using commercially avaible kits: High degree of between - Kit variability
-
Boots LR, Potter S, Potter D, Azziz R. Measurement of total serum testosterone levels using commercially avaible kits: high degree of between - kit variability.Fert Steril 69:286-292, 1998
-
(1998)
Fert Steril
, vol.69
, pp. 286-292
-
-
Boots, L.R.1
Potter, S.2
Potter, D.3
Azziz, R.4
-
16
-
-
0042868816
-
Testosterone measurement by 10 immunoassay and by isotope-dilution gas chromatography-mass spectrometry in sera from 116 men, women and children
-
Taieb J, Mathian B, Millot F, Patricot M-C, Mathieb E, Queyrel N, Lacroix I, Somma-Delpero C, Boudou P. Testosterone measurement by 10 immunoassay and by isotope-dilution gas chromatography-mass spectrometry in sera from 116 men, women and children. Clin Chem 49:1381-1395, 2003
-
(2003)
Clin Chem
, vol.49
, pp. 1381-1395
-
-
Taieb, J.1
Mathian, B.2
Millot, F.3
Patricot, M.-C.4
Mathieb, E.5
Queyrel, N.6
Lacroix, I.7
Somma-Delpero, C.8
Boudou, P.9
-
17
-
-
0029964463
-
Serum total testosterone, immunoassay compared with negative chemical ionization gas chromatography
-
Fitzgerald RL, Herold DA. Serum total testosterone, immunoassay compared with negative chemical ionization gas chromatography. Clin Chem 42:749-755, 1996
-
(1996)
Clin Chem
, vol.42
, pp. 749-755
-
-
Fitzgerald, R.L.1
Herold, D.A.2
-
18
-
-
33751526500
-
Position statement: Criteria for defining polycystic ovary syndrome as a predominantly hyperandrogenic syndrome: An Androgen Excess Society guideline
-
Azziz R, Carmina E, Dewailly D, Diamanti-Kandarakis E, Escobar-Morreale HF, Futterweit W, Janssen OE, Legro RS, Norman RJ, Taylor AE, Witchel SF. Position statement: criteria for defining polycystic ovary syndrome as a predominantly hyperandrogenic syndrome: An Androgen Excess Society guideline. J Clin Endocrinol Metab 91:4237-4245, 2006
-
(2006)
J Clin Endocrinol Metab
, vol.91
, pp. 4237-4245
-
-
Azziz, R.1
Carmina, E.2
Dewailly, D.3
Diamanti-Kandarakis, E.4
Escobar-Morreale, H.F.5
Futterweit, W.6
Janssen, O.E.7
Legro, R.S.8
Norman, R.J.9
Taylor, A.E.10
Witchel, S.F.11
-
19
-
-
0018757751
-
Determination of steroid hormones by the use of istope dilution-mass spectrometry: A definitive method in clinical chemistry
-
Siekmann L. Determination of steroid hormones by the use of istope dilution-mass spectrometry: a definitive method in clinical chemistry. J Steroid Biochem 11:117-123, 1979
-
(1979)
J Steroid Biochem
, vol.11
, pp. 117-123
-
-
Siekmann, L.1
-
20
-
-
0022086552
-
International Federation of Clinical Chemistry (IFCC). Office for Reference Methodos and Materials (ORMM) Methodological aspects on quantitative mass spectrometry used for accuracy control in clinical chemistry
-
Lawson AM, Gaskell SJ, Hjelm M. International Federation of Clinical Chemistry (IFCC). Office for Reference Methodos and Materials (ORMM) Methodological aspects on quantitative mass spectrometry used for accuracy control in clinical chemistry. J Clin Chem Clin Biochem 23:433-441, 1985
-
(1985)
J Clin Chem Clin Biochem
, vol.23
, pp. 433-441
-
-
Lawson, A.M.1
Gaskell, S.J.2
Hjelm, M.3
-
21
-
-
0034130651
-
A new modular chemiluminescence immunoassay analyser evaluated
-
Ognibene A, Drake CJ, Jeng KY, Pascucci TE, Hsu S, Luceri F. A new modular chemiluminescence immunoassay analyser evaluated. Clin Chem Lab Med 38:254-260, 2000
-
(2000)
Clin Chem Lab Med
, vol.38
, pp. 254-260
-
-
Ognibene, A.1
Drake, C.J.2
Jeng, K.Y.3
Pascucci, T.E.4
Hsu, S.5
Luceri, F.6
-
22
-
-
0025097893
-
No SHBG interference with coat - A tube total testosteronedirect RIA kit
-
Bodlaender, P. No SHBG interference with coat - A tube total testosteronedirect RIA kit. Clin Chem 36:173, 1990
-
(1990)
Clin Chem
, vol.36
, pp. 173
-
-
Bodlaender, P.1
-
23
-
-
0041460935
-
Endocrine fuction
-
Tietz NW eds. WB Saunders Philadelphia
-
Chattoraj S. Endocrine fuction. Tietz NW eds. WB Saunders Philadelphia Fundamentals of clinical chemistry 699-817, 1976.
-
(1976)
Fundamentals of Clinical Chemistry
, pp. 699-817
-
-
Chattoraj, S.1
-
24
-
-
0019735805
-
Transport of steroid hormones: Interaction of 70 drugs with testosterone - Binding globulin and corticosteroid - binding globulin in human plasma
-
Pugeat MM, Dunn JF, Nisula BC. Transport of steroid hormones: Interaction of 70 drugs with testosterone - binding globulin and corticosteroid - binding globulin in human plasma. J Clin Endocrinol Metab 53:69-75, 1981
-
(1981)
J Clin Endocrinol Metab
, vol.53
, pp. 69-75
-
-
Pugeat, M.M.1
Dunn, J.F.2
Nisula, B.C.3
-
25
-
-
0028834526
-
Serum binding of steroid tracers and its possible effects on direct steroid immunoassay
-
Micallef JV, Hayes MM Ltif A, Ahsan R, Sufi SB. Serum binding of steroid tracers and its possible effects on direct steroid immunoassay. Ann Clin Biochem 32:566-574, 1995
-
(1995)
Ann Clin Biochem
, vol.32
, pp. 566-574
-
-
Micallef, J.V.1
Hayes, M.M.2
Ltif, A.3
Ahsan, R.4
Sufi, S.B.5
-
26
-
-
84872425532
-
Extractive and chromatographic procedures on serum samples of normal women for testosterone measurement did not improve the high results variability observed among available methods
-
Abstract P2-623
-
Scaglia HE, Role N, Neira F, Fuillerat S, Corthey C, Riesco O, Scaglia J, Zylbersztein CC, Chichizola C and Aquilano DR. Extractive and chromatographic procedures on serum samples of normal women for testosterone measurement did not improve the high results variability observed among available methods. The Endocrine Society's 88 th Annual Meeting. Boston, Massachusetts, USA, june 24-27, 2006. Abstract P2-623
-
The Endocrine Society's 88 Th Annual Meeting. Boston, Massachusetts, USA, June 24-27, 2006
-
-
Scaglia, H.E.1
Role, N.2
Neira, F.3
Fuillerat, S.4
Corthey, C.5
Riesco, O.6
Scaglia, J.7
Zylbersztein, C.C.8
Chichizola, C.9
Aquilano, D.R.10
-
27
-
-
77955428229
-
Standardization of testosterone measurements in humans
-
Vesper HW, Botelho JC. Standardization of testosterone measurements in humans. J Steroid Bioch Mol Biology 121:513-519, 2010
-
(2010)
J Steroid Bioch Mol Biology
, vol.121
, pp. 513-519
-
-
Vesper, H.W.1
Botelho, J.C.2
-
28
-
-
66549112943
-
Traceability in laboratory medicine
-
Vesper HW, Thienpont LM, Traceability in laboratory medicine. Clin Chem 55:1067-1075, 2009
-
(2009)
Clin Chem
, vol.55
, pp. 1067-1075
-
-
Vesper, H.W.1
Thienpont, L.M.2
-
29
-
-
84872377366
-
Impact of sample preparation procedures of testosterone measurement by isoopic-dilution liquid chromatography-tandem mass spectrometry
-
Abstract 122
-
Botelho JC, Shacklady C, Razdan R Wesper HW. Impact of sample preparation procedures of testosterone measurement by isoopic-dilution liquid chromatography-tandem mass spectrometry. Clin Chem 54 Abstract 122, 2008
-
(2008)
Clin Chem
, vol.54
-
-
Botelho, J.C.1
Shacklady, C.2
Razdan, R.3
Wesper, H.W.4
-
30
-
-
48949106598
-
State-of-the-art of serum testosterone measurement by isoopic-dilution liquid chromatography-tandem mass spectrometry
-
Thienpont LM, Van Uytfanghe AL, Blincko S, Ramsay CS,Xie H, Doss RC, Keevil BG, Owen LJ, Rockwood AI, Kushnir MM, Chun KY, Chandler HP, Field PM, Sluss PM. State-of-the-art of serum testosterone measurement by isoopic-dilution liquid chromatography-tandem mass spectrometry. Clin Chem 54:1290-1297, 2008
-
(2008)
Clin Chem
, vol.54
, pp. 1290-1297
-
-
Thienpont, L.M.1
Van Uytfanghe, A.L.2
Blincko, S.3
Ramsay, C.S.4
Xie, H.5
Doss, R.C.6
Keevil, B.G.7
Owen, L.J.8
Rockwood, A.I.9
Kushnir, M.M.10
Chun, K.Y.11
Chandler, H.P.12
Field, P.M.13
Sluss, P.M.14
-
31
-
-
62149150656
-
Interlaboratory comparison study of serum total testosterone measurements performed by mass spectrometry methods
-
Vesper HW, Bhasin S, Wang C, Tai SS, Dodge LA, Sinh RJ, Nelson J, Ohorodnik S, Clarke NJ, Parker Jr CR, Razdan R, Monsell EA, Myers GL. Interlaboratory comparison study of serum total testosterone measurements performed by mass spectrometry methods. Steroids 74:498-503, 2009
-
(2009)
Steroids
, vol.74
, pp. 498-503
-
-
Vesper, H.W.1
Bhasin, S.2
Wang, C.3
Tai, S.S.4
Dodge, L.A.5
Sinh, R.J.6
Nelson, J.7
Ohorodnik, S.8
Clarke, N.J.9
Parker Jr., C.R.10
Razdan, R.11
Monsell, E.A.12
Myers, G.L.13
|