메뉴 건너뛰기




Volumn 44, Issue 1, 2013, Pages 128-134

A simple audio-visual prompt device can improve CPR performance

Author keywords

cardiopulmonary resuscitation; chest compression; emergency medical technician; manikin; ventilation

Indexed keywords

ADULT; ARTICLE; AUDIOVISUAL EQUIPMENT; BREATHING RATE; FEMALE; HUMAN; HYPERVENTILATION; MALE; PRIORITY JOURNAL; RESCUE PERSONNEL; RESUSCITATION; TIDAL VOLUME;

EID: 84872351122     PISSN: 07364679     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.jemermed.2011.09.033     Document Type: Article
Times cited : (8)

References (20)
  • 1
    • 77950868240 scopus 로고    scopus 로고
    • Predictors of survival from out-of-hospital cardiac arrest: A systemic review and meta-Analysis
    • C. Sasson, M.A. Rogers, J. Dahl, and A.L. Kellermann Predictors of survival from out-of-hospital cardiac arrest: A systemic review and meta-Analysis Circ Cardiovasc Qual Outcomes 3 2010 63 81
    • (2010) Circ Cardiovasc Qual Outcomes , vol.3 , pp. 63-81
    • Sasson, C.1    Rogers, M.A.2    Dahl, J.3    Kellermann, A.L.4
  • 2
    • 0037118665 scopus 로고    scopus 로고
    • Adverse outcomes of interrupted precordial compression during automated defibrillation
    • T. Yu, M.H. Weil, and W. Tang Adverse outcomes of interrupted precordial compression during automated defibrillation Circulation 106 2002 368 372
    • (2002) Circulation , vol.106 , pp. 368-372
    • Yu, T.1    Weil, M.H.2    Tang, W.3
  • 3
    • 12244295495 scopus 로고    scopus 로고
    • Quality of cardiopulmonary resuscitation during out-of-hospital cardiac arrest
    • L. Wik, J. Kramer-Johansen, and H. Myklebust Quality of cardiopulmonary resuscitation during out-of-hospital cardiac arrest JAMA 293 2005 299 304
    • (2005) JAMA , vol.293 , pp. 299-304
    • Wik, L.1    Kramer-Johansen, J.2    Myklebust, H.3
  • 4
    • 12244267087 scopus 로고    scopus 로고
    • Quality of cardiopulmonary resuscitation during in-hospital cardiac arrest
    • B.S. Abella, J.P. Alvarado, and H. Myklebust Quality of cardiopulmonary resuscitation during in-hospital cardiac arrest JAMA 293 2005 305 310
    • (2005) JAMA , vol.293 , pp. 305-310
    • Abella, B.S.1    Alvarado, J.P.2    Myklebust, H.3
  • 5
    • 13444274527 scopus 로고    scopus 로고
    • Chest compression rates during cardiopulmonary resuscitation are suboptimal: A prospective study during in-hospital cardiac arrest
    • B.S. Abella, N. Sandbo, and P. Vassilatos Chest compression rates during cardiopulmonary resuscitation are suboptimal: A prospective study during in-hospital cardiac arrest Circulation 111 2005 428 434
    • (2005) Circulation , vol.111 , pp. 428-434
    • Abella, B.S.1    Sandbo, N.2    Vassilatos, P.3
  • 6
    • 78149244181 scopus 로고    scopus 로고
    • Part 5: Adult basic life support: 2010 International Consensus on Cardiopulmonary Resuscitation and Emergency Cardiovascular Care Science with Treatment Recommendations
    • M.R. Sayre, R.W. Koster, and M. Botha Part 5: Adult basic life support: 2010 International Consensus on Cardiopulmonary Resuscitation and Emergency Cardiovascular Care Science With Treatment Recommendations Circulation 122 2010 S298 S324
    • (2010) Circulation , vol.122
    • Sayre, M.R.1    Koster, R.W.2    Botha, M.3
  • 7
    • 12944326281 scopus 로고    scopus 로고
    • Evaluating the quality of prehospital cardiopulmonary resuscitation by reviewing automated external defibrillator records and survival for out-of-hospital witnessed arrests
    • P.C. Ko, W.J. Chen, C.H. Lin, M.H. Ma, and F.Y. Lin Evaluating the quality of prehospital cardiopulmonary resuscitation by reviewing automated external defibrillator records and survival for out-of-hospital witnessed arrests Resuscitation 64 2005 163 169
    • (2005) Resuscitation , vol.64 , pp. 163-169
    • Ko, P.C.1    Chen, W.J.2    Lin, C.H.3    Ma, M.H.4    Lin, F.Y.5
  • 8
    • 33646154863 scopus 로고    scopus 로고
    • The quality of chest compressions by trained personnel: The effect of feedback, via the CPREzy, in a randomized controlled trial using a manikin model
    • G.J. Noordergraaf, B.W. Drinkwaard, and P.F. van Berkom The quality of chest compressions by trained personnel: the effect of feedback, via the CPREzy, in a randomized controlled trial using a manikin model Resuscitation 69 2006 241 252
    • (2006) Resuscitation , vol.69 , pp. 241-252
    • Noordergraaf, G.J.1    Drinkwaard, B.W.2    Van Berkom, P.F.3
  • 9
    • 0036296601 scopus 로고    scopus 로고
    • Improvement in timing and effectiveness of external cardiac compressions with a new non-invasive device: The CPR-Ezy
    • A.J. Boyle, A.M. Wilson, K. Connelly, L. McGuigan, J. Wilson, and R. Whitbourn Improvement in timing and effectiveness of external cardiac compressions with a new non-invasive device: the CPR-Ezy Resuscitation 54 2002 63 67
    • (2002) Resuscitation , vol.54 , pp. 63-67
    • Boyle, A.J.1    Wilson, A.M.2    Connelly, K.3    McGuigan, L.4    Wilson, J.5    Whitbourn, R.6
  • 10
    • 0034839402 scopus 로고    scopus 로고
    • An automated voice advisory manikin system for training in basic life support without an instructor. A novel approach to CPR training
    • L. Wik, J. Thowsen, and P.A. Steen An automated voice advisory manikin system for training in basic life support without an instructor. A novel approach to CPR training Resuscitation 50 2001 167 172
    • (2001) Resuscitation , vol.50 , pp. 167-172
    • Wik, L.1    Thowsen, J.2    Steen, P.A.3
  • 11
    • 0032031072 scopus 로고    scopus 로고
    • The study of the effectiveness of chest compressions using the CPR-plus
    • C. Elding, P. Baskett, and A. Hughes The study of the effectiveness of chest compressions using the CPR-plus Resuscitation 36 1998 169 173
    • (1998) Resuscitation , vol.36 , pp. 169-173
    • Elding, C.1    Baskett, P.2    Hughes, A.3
  • 13
    • 0035856551 scopus 로고    scopus 로고
    • Adverse hemodynamic effects of interrupting chest compressions for rescue breathing during cardiopulmonary resuscitation for ventricular fibrillation cardiac arrest
    • R.A. Berg, A.B. Sanders, and K.B. Kern Adverse hemodynamic effects of interrupting chest compressions for rescue breathing during cardiopulmonary resuscitation for ventricular fibrillation cardiac arrest Circulation 104 2001 2465 2470
    • (2001) Circulation , vol.104 , pp. 2465-2470
    • Berg, R.A.1    Sanders, A.B.2    Kern, K.B.3
  • 15
    • 33751254313 scopus 로고    scopus 로고
    • Quality of out-of-hospital cardiopulmonary resuscitation with real time automated feedback: A prospective interventional study
    • J. Kramer-Johansen, H. Myklebust, and L. Wik Quality of out-of-hospital cardiopulmonary resuscitation with real time automated feedback: A prospective interventional study Resuscitation 71 2006 283 292
    • (2006) Resuscitation , vol.71 , pp. 283-292
    • Kramer-Johansen, J.1    Myklebust, H.2    Wik, L.3
  • 16
    • 0020512294 scopus 로고
    • Relationship of blood pressure and flow during CPR to chest compression amplitude: Evidence for an effective compression threshold
    • C.F. Babbs, W.D. Voorhees, K.R. Fitzgerald, H.R. Holmes, and L.A. Geddes Relationship of blood pressure and flow during CPR to chest compression amplitude: evidence for an effective compression threshold Ann Emerg Med 12 1983 527 532
    • (1983) Ann Emerg Med , vol.12 , pp. 527-532
    • Babbs, C.F.1    Voorhees, W.D.2    Fitzgerald, K.R.3    Holmes, H.R.4    Geddes, L.A.5
  • 17
    • 0021364531 scopus 로고
    • Coronary blood flow during cardiopulmonary resuscitation in swine
    • R.F. Bellamy, L.R. DeGuzman, and D.C. Pedersen Coronary blood flow during cardiopulmonary resuscitation in swine Circulation 69 1984 174 180
    • (1984) Circulation , vol.69 , pp. 174-180
    • Bellamy, R.F.1    Deguzman, L.R.2    Pedersen, D.C.3
  • 18
    • 33847383005 scopus 로고    scopus 로고
    • CPR quality improvement during in-hospital cardiac arrest using a real-time audiovisual feedback system
    • B.S. Abella, D.P. Edelson, and S. Kim CPR quality improvement during in-hospital cardiac arrest using a real-time audiovisual feedback system Resuscitation 73 2007 54 61
    • (2007) Resuscitation , vol.73 , pp. 54-61
    • Abella, B.S.1    Edelson, D.P.2    Kim, S.3
  • 19
    • 67349126997 scopus 로고    scopus 로고
    • Skin and soft tissue damage caused by use of feedback-sensor during chest compressions
    • G.C. Cho Skin and soft tissue damage caused by use of feedback-sensor during chest compressions Resuscitation 80 2009 600
    • (2009) Resuscitation , vol.80 , pp. 600
    • Cho, G.C.1
  • 20
    • 67349166152 scopus 로고    scopus 로고
    • The use of CPR feedback/prompt devices during training and CPR performance: A systematic review
    • J. Yeung, R. Meeks, D. Edelson, F. Gao, J. Soar, and G.D. Perkins The use of CPR feedback/prompt devices during training and CPR performance: A systematic review Resuscitation 80 2009 743 751
    • (2009) Resuscitation , vol.80 , pp. 743-751
    • Yeung, J.1    Meeks, R.2    Edelson, D.3    Gao, F.4    Soar, J.5    Perkins, G.D.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.