메뉴 건너뛰기




Volumn 178, Issue , 2013, Pages 101-106

Use of hemoglobin as alternative to peroxidases in cholesterol amperometric biosensors

Author keywords

Amperometric measurements; Biosensor; Cholesterol; Enzymes; Hemoglobin; LbL film

Indexed keywords

AMPEROMETRIC BIOSENSORS; AMPEROMETRIC MEASUREMENTS; CHICKEN EGG YOLK; CHOLESTEROL OXIDASE; ELECTRON MEDIATOR; INTERFERENTS; LAYER-BY-LAYER METHODS; LOW COSTS; MOLECULAR ARCHITECTURE; OPTIMIZATION PROCEDURES; PHOSPHOLIPID LIPOSOMES; POLY(ALLYLAMINE HYDROCHLORIDE); POLYETHYLENEIMINE; REAL SAMPLES;

EID: 84872342188     PISSN: 09254005     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.snb.2012.12.005     Document Type: Article
Times cited : (19)

References (33)
  • 1
    • 0033662988 scopus 로고    scopus 로고
    • Electrochemical diagnostic strip device for total cholesterol and its subfractions
    • R. Foster, J. Cassidy, and E. O'Donoghue Electrochemical diagnostic strip device for total cholesterol and its subfractions Electroanalysis 12 2000 716 721
    • (2000) Electroanalysis , vol.12 , pp. 716-721
    • Foster, R.1    Cassidy, J.2    O'Donoghue, E.3
  • 2
    • 0033104357 scopus 로고    scopus 로고
    • Abnormalities of membrane function and lipid metabolism in hypertension: A review
    • DOI 10.1016/S0895-7061(98)00178-2, PII S0895706198001782
    • J. Zicha, J. Kuneš, and M.-A. Devynck Abnormalities of membrane function and lipid metabolism in hypertension: a review American Journal of Hypertension 12 1999 315 331 (Pubitemid 29147359)
    • (1999) American Journal of Hypertension , vol.12 , Issue.3 , pp. 315-331
    • Zicha, J.1    Kunes, J.2    Devynck, M.-A.3
  • 3
    • 11844266646 scopus 로고    scopus 로고
    • An amperometric cholesterol biosensor based on multiwalled carbon nanotubes and organically modified sol-gel/chitosan hybrid composite film
    • DOI 10.1016/j.ab.2004.10.040, PII S0003269704008590
    • X. Tan, M. Li, P. Cai, L. Luo, and X. Zou An amperometric cholesterol biosensor based on multiwalled carbon nanotubes and organically modified sol-gel/chitosan hybrid composite film Analytical Biochemistry 337 2005 111 120 (Pubitemid 40092786)
    • (2005) Analytical Biochemistry , vol.337 , Issue.1 , pp. 111-120
    • Tan, X.1    Li, M.2    Cai, P.3    Luo, L.4    Zou, X.5
  • 4
    • 0034773242 scopus 로고    scopus 로고
    • Cholesterol biosensors prepared by layer-by-layer technique
    • DOI 10.1016/S0956-5663(01)00208-1, PII S0956566301002081
    • M.K. Ram, P. Bertoncello, H. Ding, S. Paddeu, and C. Nicolini Cholesterol biosensors prepared by layer-by-layer technique Biosensors and Bioelectronics 16 2001 849 856 (Pubitemid 33009323)
    • (2001) Biosensors and Bioelectronics , vol.16 , Issue.9-12 , pp. 849-856
    • Ram, M.Ku.1    Bertoncello, P.2    Ding, H.3    Paddeu, S.4    Nicolini, C.5
  • 6
    • 77952951832 scopus 로고    scopus 로고
    • Preparation of an electrochemical biosensor based on lipid membranes in nanoporous alumina
    • J.-B. Largueze, K.E. Kirat, and S. Morandat Preparation of an electrochemical biosensor based on lipid membranes in nanoporous alumina Colloids and Surfaces B 79 2010 33 40
    • (2010) Colloids and Surfaces B , vol.79 , pp. 33-40
    • Largueze, J.-B.1    Kirat, K.E.2    Morandat, S.3
  • 8
    • 1642300447 scopus 로고    scopus 로고
    • Direct electrochemistry and electrocatalysis of hemoglobin immobilized on carbon paste electrode by silica sol-gel film
    • DOI 10.1016/j.bios.2003.11.012, PII S095656630300410X
    • Q. Wang, G. Lu, and B. Yang Direct electrochemistry and electrocatalysis of hemoglobin immobilized on carbon paste electrode by silica sol-gel film Biosensors and Bioelectronics 19 2004 1269 1275 (Pubitemid 38376389)
    • (2004) Biosensors and Bioelectronics , vol.19 , Issue.10 , pp. 1269-1275
    • Wang, Q.1    Lu, G.2    Yang, B.3
  • 9
    • 77950791949 scopus 로고    scopus 로고
    • Smart electrochemical biosensors: From advanced materials to ultrasensitive devices
    • O.A. Sadik, S.K. Mwilu, and A. Aluoch Smart electrochemical biosensors: from advanced materials to ultrasensitive devices Electrochimica Acta 55 2010 4287 4295
    • (2010) Electrochimica Acta , vol.55 , pp. 4287-4295
    • Sadik, O.A.1    Mwilu, S.K.2    Aluoch, A.3
  • 10
    • 23044437622 scopus 로고    scopus 로고
    • Sensor and biosensor preparation, optimisation and applications of Prussian Blue modified electrodes
    • DOI 10.1016/j.bios.2004.12.001, PII S0956566304005883
    • F. Ricci, and G. Palleschi Sensor and biosensor preparation, optimisation and applications of Prussian Blue modified electrodes Biosensors and Bioelectronics 21 2005 389 407 (Pubitemid 41074928)
    • (2005) Biosensors and Bioelectronics , vol.21 , Issue.3 , pp. 389-407
    • Ricci, F.1    Palleschi, G.2
  • 11
    • 0032154501 scopus 로고    scopus 로고
    • The electrocatalytic activity of Prussian blue in hydrogen peroxide reduction studied using a wall-jet electrode with continuous flow
    • PII S0022072898002022
    • A.A. Karyakin, E.E. Karyakina, and L. Gorton The electrocatalytic activity of Prussian blue in hydrogen peroxide reduction studied using a wall-jet electrode with continuous flow Journal of Electroanalytical Chemistry 456 1998 97 104 (Pubitemid 128424586)
    • (1998) Journal of Electroanalytical Chemistry , vol.456 , Issue.1-2 , pp. 97-104
    • Karyakin, A.A.1    Karyakina, E.E.2    Gorton, L.3
  • 12
    • 0036797270 scopus 로고    scopus 로고
    • Electrochemical preparation and characterisation of bilayer films composed by Prussian Blue and conducting polymer
    • S. Lupu, C. Mihailciuc, L. Pigani, R. Seeber, N. Totir, and C. Zanardi Electrochemical preparation and characterisation of bilayer films composed by Prussian Blue and conducting polymer Electrochemistry Communications 4 2002 753 758
    • (2002) Electrochemistry Communications , vol.4 , pp. 753-758
    • Lupu, S.1    Mihailciuc, C.2    Pigani, L.3    Seeber, R.4    Totir, N.5    Zanardi, C.6
  • 13
    • 0034896783 scopus 로고    scopus 로고
    • An electrochemical multienzymatic biosensor for determination of cholesterol
    • DOI 10.1016/S0302-4598(01)00105-2, PII S0302459801001052
    • C. Bongiovanni, T. Ferri, A. Poscia, M. Varalli, R. Santucci, and A. Desideri An electrochemical multienzymatic biosensor for determination of cholesterol Bioelectrochemistry 54 2001 17 22 (Pubitemid 32739227)
    • (2001) Bioelectrochemistry , vol.54 , Issue.1 , pp. 17-22
    • Bongiovanni, C.1    Ferri, T.2    Poscia, A.3    Varalli, M.4    Santucci, R.5    Desideri, A.6
  • 14
    • 53049109034 scopus 로고    scopus 로고
    • Highly sensitive and selective cholesterol biosensor based on direct electron transfer of hemoglobin
    • C. Zhao, L. Wan, L. Jiang, Q. Wang, and K. Jiao Highly sensitive and selective cholesterol biosensor based on direct electron transfer of hemoglobin Analytical Biochemistry 383 2008 25 30
    • (2008) Analytical Biochemistry , vol.383 , pp. 25-30
    • Zhao, C.1    Wan, L.2    Jiang, L.3    Wang, Q.4    Jiao, K.5
  • 15
    • 84863555039 scopus 로고    scopus 로고
    • Poly(neutral red)/cholesterol oxidase modified carbon film electrode for cholesterol biosensing
    • A.C. Torres, M.E. Ghica, and C.M.A. Brett Poly(neutral red)/cholesterol oxidase modified carbon film electrode for cholesterol biosensing Electroanalysis 24 2012 1547 1553
    • (2012) Electroanalysis , vol.24 , pp. 1547-1553
    • Torres, A.C.1    Ghica, M.E.2    Brett, C.M.A.3
  • 16
    • 39449101194 scopus 로고    scopus 로고
    • Potential application of hemoglobin as an alternative to peroxidase in a phenol biosensor
    • DOI 10.1016/j.tsf.2007.04.123, PII S004060900700733X
    • A.K.M. Kafi, D.-Y. Lee, S.-H. Park, and Y.-S. Kwon Potential application of hemoglobin as an alternative to peroxidase in a phenol biosensor Thin Solid Films 516 2008 2816 2821 (Pubitemid 351273365)
    • (2008) Thin Solid Films , vol.516 , Issue.9 , pp. 2816-2821
    • Kafi, A.K.M.1    Lee, D.-Y.2    Park, S.-H.3    Kwon, Y.-S.4
  • 17
    • 67349219101 scopus 로고    scopus 로고
    • Amperometric biosensor for hydrogen peroxide and nitrite based on hemoglobin immobilized on one-dimensional gold nanoparticle
    • J. Hong, and Z. Dai Amperometric biosensor for hydrogen peroxide and nitrite based on hemoglobin immobilized on one-dimensional gold nanoparticle Sensors and Actuators B 140 2009 222 226
    • (2009) Sensors and Actuators B , vol.140 , pp. 222-226
    • Hong, J.1    Dai, Z.2
  • 19
    • 34547538271 scopus 로고    scopus 로고
    • Assembly of layer-by-layer films of electroactive hemoglobin and surfactant didodecyldimethylammonium bromide
    • DOI 10.1016/j.jcis.2007.05.057, PII S0021979707006455
    • Y. Hu, H. Sun, and N. Hu Assembly of layer-by-layer films of electroactive hemoglobin and surfactant didodecyldimethylammonium bromide Journal of Colloid and Interface Science 314 2007 131 140 (Pubitemid 47187423)
    • (2007) Journal of Colloid and Interface Science , vol.314 , Issue.1 , pp. 131-140
    • Hu, Y.1    Sun, H.2    Hu, N.3
  • 20
    • 39749123171 scopus 로고    scopus 로고
    • Self-assembly of electroactive layer-by-layer films of heme proteins with anionic surfactant dihexadecyl phosphate
    • W. Shan, H. Liu, J. Shi, L. Yang, and N. Hu Self-assembly of electroactive layer-by-layer films of heme proteins with anionic surfactant dihexadecyl phosphate Biophysical Chemistry 134 2008 101 109
    • (2008) Biophysical Chemistry , vol.134 , pp. 101-109
    • Shan, W.1    Liu, H.2    Shi, J.3    Yang, L.4    Hu, N.5
  • 21
    • 34547544901 scopus 로고    scopus 로고
    • Immobilization of uricase in layer-by-layer films used in amperometric biosensors for uric acid
    • DOI 10.1007/s10008-007-0314-4
    • M.L. Moraes, U.P. Rodrigues Filho, O.N. Oliveira, and M. Ferreira Immobilization of uricase in layer-by-layer films used in amperometric biosensors for uric acid Journal of Solid State Electrochemistry 11 2007 1489 1495 (Pubitemid 47179820)
    • (2007) Journal of Solid State Electrochemistry , vol.11 , Issue.11 , pp. 1489-1495
    • Moraes, M.L.1    Rodrigues Filho, U.P.2    Oliveira Jr., O.N.3    Ferreira, M.4
  • 22
    • 41449109306 scopus 로고    scopus 로고
    • Phytase immobilization on modified electrodes for amperometric biosensing
    • DOI 10.1016/j.snb.2007.11.004, PII S0925400507009239
    • M.L. Moraes, O.N. Oliveira Jr., U.P.R. Filho, and M. Ferreira Phytase immobilization on modified electrodes for amperometric biosensing Sensors and Actuators B: Chemical 131 2008 210 215 (Pubitemid 351458644)
    • (2008) Sensors and Actuators, B: Chemical , vol.131 , Issue.1 , pp. 210-215
    • Moraes, M.L.1    Oliveira Jr., O.N.2    Filho, U.P.R.3    Ferreira, M.4
  • 23
    • 0034213780 scopus 로고    scopus 로고
    • Co-immobilization of cholesterol oxidase and horseradish peroxidase in a sol-gel film
    • DOI 10.1016/S0003-2670(00)00792-3, PII S0003267000007923
    • A. Kumar, R. Malhotra, B.D. Malhotra, and S.K. Grover Co-immobilization of cholesterol oxidase and horseradish peroxidase in a sol-gel film Analytica Chimica Acta 414 2000 43 50 (Pubitemid 30251892)
    • (2000) Analytica Chimica Acta , vol.414 , Issue.1-2 , pp. 43-50
    • Kumar, A.1    Malhotra, R.2    Malhotra, B.D.3    Grover, S.K.4
  • 24
    • 0032812358 scopus 로고    scopus 로고
    • Flow injection potentiometry for enzymatic assay of cholesterol with a tungsten electrode sensor
    • M. Situmorang, P.W. Alexander, and D.B. Hibbert Flow injection potentiometry for enzymatic assay of cholesterol with a tungsten electrode sensor Talanta 49 1999 639 649
    • (1999) Talanta , vol.49 , pp. 639-649
    • Situmorang, M.1    Alexander, P.W.2    Hibbert, D.B.3
  • 25
    • 0028313712 scopus 로고
    • Fabrication and characterization of a screen-printed, disposable, amperometric cholesterol biosensor
    • M.A.T. Gilmartin, and J.P. Hart Fabrication and characterization of a screen-printed, disposable, amperometric cholesterol biosensor Analyst 119 1994 2331
    • (1994) Analyst , vol.119 , pp. 2331
    • Gilmartin, M.A.T.1    Hart, J.P.2
  • 27
    • 33747111321 scopus 로고    scopus 로고
    • Multienzymatic-rotating biosensor for total cholesterol determination in a FIA system
    • DOI 10.1016/j.talanta.2006.02.043, PII S0039914006001639
    • E. Salinas, V. Rivero, A.A.J. Torriero, D. Benuzzi, M.I. Sanz, and J. Raba Multienzymatic-rotating biosensor for total cholesterol determination in a FIA system Talanta 70 2006 244 250 (Pubitemid 44223621)
    • (2006) Talanta , vol.70 , Issue.2 , pp. 244-250
    • Salinas, E.1    Rivero, V.2    Torriero, A.A.J.3    Benuzzi, D.4    Sanz, M.I.5    Raba, J.6
  • 28
    • 80053239966 scopus 로고    scopus 로고
    • Potassium-doped carbon nanotubes toward the direct electrochemistry of cholesterol oxidase and its application in highly sensitive cholesterol biosensor
    • X.-R. Li, J.-J. Xu, and H.-Y. Chen Potassium-doped carbon nanotubes toward the direct electrochemistry of cholesterol oxidase and its application in highly sensitive cholesterol biosensor Electrochimica Acta 56 2011 9378 9385
    • (2011) Electrochimica Acta , vol.56 , pp. 9378-9385
    • Li, X.-R.1    Xu, J.-J.2    Chen, H.-Y.3
  • 29
    • 78650259107 scopus 로고    scopus 로고
    • Development of an amperometric cholesterol biosensor based on graphene-Pt nanoparticle hybrid material
    • R.S. Dey, and C.R. Raj Development of an amperometric cholesterol biosensor based on graphene-Pt nanoparticle hybrid material Journal of Physical Chemistry C 114 2010 21427 21433
    • (2010) Journal of Physical Chemistry C , vol.114 , pp. 21427-21433
    • Dey, R.S.1    Raj, C.R.2
  • 30
    • 72649100529 scopus 로고    scopus 로고
    • Direct electrochemistry of cholesterol oxidase immobilized on a conducting polymer: Application for a cholesterol biosensor
    • A.A. Abdelwahab, M.-S. Won, and Y.-B. Shim Direct electrochemistry of cholesterol oxidase immobilized on a conducting polymer: application for a cholesterol biosensor Electroanalysis 22 2010 21 25
    • (2010) Electroanalysis , vol.22 , pp. 21-25
    • Abdelwahab, A.A.1    Won, M.-S.2    Shim, Y.-B.3
  • 31
    • 84866251800 scopus 로고    scopus 로고
    • An amperometric bienzymatic cholesterol biosensor based on functionalized graphene modified electrode and its electrocatalytic activity towards total cholesterol determination
    • R. Manjunatha, G. Shivappa Suresh, J. Savio Melo, S.F. D'Souza, and T. Venkatarangaiah Venkatesha An amperometric bienzymatic cholesterol biosensor based on functionalized graphene modified electrode and its electrocatalytic activity towards total cholesterol determination Talanta 99 2012 302 309
    • (2012) Talanta , vol.99 , pp. 302-309
    • Manjunatha, R.1    Shivappa Suresh, G.2    Savio Melo, J.3    D'Souza, S.F.4    Venkatarangaiah Venkatesha, T.5
  • 32
    • 63749111814 scopus 로고    scopus 로고
    • An amperometric glucose biosensor based on the immobilization of glucose oxidase on the ZnO nanotubes
    • T. Kong, Y. Chen, Y. Ye, K. Zhang, Z. Wang, and X. Wang An amperometric glucose biosensor based on the immobilization of glucose oxidase on the ZnO nanotubes Sensors and Actuators B: Chemical 138 2009 344 350
    • (2009) Sensors and Actuators B: Chemical , vol.138 , pp. 344-350
    • Kong, T.1    Chen, Y.2    Ye, Y.3    Zhang, K.4    Wang, Z.5    Wang, X.6
  • 33
    • 84868347946 scopus 로고    scopus 로고
    • Information visualization to enhance sensitivity and selectivity in biosensing
    • 10.1007/s13758-012-0053-7
    • O.N. Oliveira, F.J. Pavinatto, C.J.L. Constantino, F.V. Paulovich, and M.C.F. Oliveira Information visualization to enhance sensitivity and selectivity in biosensing Biointerphases 7 53 2012 1 15 10.1007/s13758-012-0053-7
    • (2012) Biointerphases , vol.7 , Issue.53 , pp. 1-15
    • Oliveira, O.N.1    Pavinatto, F.J.2    Constantino, C.J.L.3    Paulovich, F.V.4    Oliveira, M.C.F.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.