Volumn 107, Issue , 2013, Pages 95-100

A short review on radioactivity in drinking water as assessed by radiometric and Inductively Coupled Plasma-Mass Spectrometry techniques

Author keywords

Quadrupole inductively coupled plasma mass spectrometry; Radiometric techniques; Radionuclides in water; Sector field inductively coupled plasma mass spectrometry

Indexed keywords


EID: 84872172898     PISSN: 0026265X     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.microc.2012.07.014     Document Type: Article
Times cited : (18)

References (44)
  • 1
    • 0003183341 scopus 로고    scopus 로고
    • Council of the European Union Council Directive 98/83/EC of 3 November 1998 on the quality of water intended for human consumption
    • (05.12.1998)
    • Council of the European Union Council Directive 98/83/EC of 3 November 1998 on the quality of water intended for human consumption. Off. J. Eur. Comm. 1998, L330:32-54. (05.12.1998).
    • (1998) Off. J. Eur. Comm. , vol.L330 , pp. 32-54
  • 2
    • 84872191671 scopus 로고    scopus 로고
    • Council Directive 98/83/EC on the quality of water intended for human consumption: calculation of derived activity concentrations, Rapporti ISTISAN 2000/16, (available at).
    • S. Risica, S. Grande, Council Directive 98/83/EC on the quality of water intended for human consumption: calculation of derived activity concentrations, Rapporti ISTISAN 2000/16, 47 pp (available at www.iss.it).
    • Risica, S.1    Grande, S.2
  • 3
    • 78650390245 scopus 로고    scopus 로고
    • Radium isotopes in Estonian groundwater: measurements, analytical correlations, population dose and a proposal for a monitoring strategy
    • Forte M., Bagnato L., Caldognetto E., Risica S., Trotti F., Rusconi R. Radium isotopes in Estonian groundwater: measurements, analytical correlations, population dose and a proposal for a monitoring strategy. J. Radiol. Prot. 2010, 30:761-780.
    • (2010) J. Radiol. Prot. , vol.30 , pp. 761-780
    • Forte, M.1    Bagnato, L.2    Caldognetto, E.3    Risica, S.4    Trotti, F.5    Rusconi, R.6
  • 4
    • 18844428583 scopus 로고    scopus 로고
    • Commission of the European Communities Commission Recommendation of 20 December 2001 on the protection of the public against exposure to radon in drinking water supplies (2001/928/Euratom)
    • (28.12.)
    • Commission of the European Communities Commission Recommendation of 20 December 2001 on the protection of the public against exposure to radon in drinking water supplies (2001/928/Euratom). Off. J. Eur. Comm. 2001, L344:85-88. (28.12.).
    • (2001) Off. J. Eur. Comm. , vol.L344 , pp. 85-88
  • 5
    • 84872201341 scopus 로고    scopus 로고
    • World Health Organization
    • WHO Geneva, 539pp.
    • World Health Organization Guidelines for drinking-water quality 2011, WHO Geneva, 539pp. Fourth edition.
    • (2011) Guidelines for drinking-water quality
  • 6
    • 84872171501 scopus 로고    scopus 로고
    • US Department of Energy (DOE)
    • US Department of Energy (DOE) HASL-300 EML Procedures Manual February 1997, http://www.orau.org/ptp/PTP%20Library/library/DOE/eml/hasl300/HASL300TOC.htm. 28th edition.
    • (1997) HASL-300 EML Procedures Manual
  • 8
    • 63249108528 scopus 로고    scopus 로고
    • ISO 9696 Water quality - Measurement of gross alpha activity in non-saline water -- Thick source method
    • 11 pages
    • ISO 9696 Water quality - Measurement of gross alpha activity in non-saline water -- Thick source method 2007, 11 pages, www.iso.org. II edition.
    • (2007)
  • 9
    • 63249108528 scopus 로고    scopus 로고
    • ISO 9697 Water quality - Measurement of gross beta activity in non-saline water -- Thick source method
    • 11 pages
    • ISO 9697 Water quality - Measurement of gross beta activity in non-saline water -- Thick source method 2008, 11 pages, www.iso.org. II edition.
    • (2008)
  • 10
    • 84872200613 scopus 로고    scopus 로고
    • ASTM Standard D1943
    • ASTM International, West Conshohocken, PA, 5 pages
    • ASTM Standard D1943 Standard Test Method for Alpha Particle Radioactivity of Water 2005, ASTM International, West Conshohocken, PA, 5 pages, www.astm.org. 10.1520/D1943-05.
    • (2005) Standard Test Method for Alpha Particle Radioactivity of Water
  • 11
    • 84872176319 scopus 로고    scopus 로고
    • ASTM Standard D1890
    • ASTM International, West Conshohocken, PA, 6 pages
    • ASTM Standard D1890 Standard Test Method for Beta Particle Radioactivity of Wate 2005, ASTM International, West Conshohocken, PA, 6 pages, www.astm.org. 10.1520/D1890-05.
    • (2005) Standard Test Method for Beta Particle Radioactivity of Wate
  • 12
    • 84872178065 scopus 로고    scopus 로고
    • ISO 11704 Water quality -Measurement of gross alpha and beta activity concentration in non saline water - Liquid scintillation counting method
    • ISO 11704 Water quality -Measurement of gross alpha and beta activity concentration in non saline water - Liquid scintillation counting method 2010-07-01, www.iso.org. First edition.
    • (2007)
  • 13
    • 84872177140 scopus 로고    scopus 로고
    • ASTM Standard D7283 Standard Test Method for Alpha - and Beta - Activity in Water by Liquid Scintillation Counting
    • ASTM International, West Conshohocken, PA, 10 pages
    • ASTM Standard D7283 Standard Test Method for Alpha - and Beta - Activity in Water by Liquid Scintillation Counting 2006, ASTM International, West Conshohocken, PA, 10 pages, www.astm.org. 10.1520/D7283-06.
    • (2006)
  • 14
    • 84872180632 scopus 로고    scopus 로고
    • ASTM Standard D3865
    • ASTM International, West Conshohocken, PA, 7 pages
    • ASTM Standard D3865 Standard Test Method for Plutonium in Water 2009, ASTM International, West Conshohocken, PA, 7 pages, www.astm.org. 10.1520/D3865-09.
    • (2009) Standard Test Method for Plutonium in Water
  • 15
    • 84872178446 scopus 로고    scopus 로고
    • ASTM Standard D3454
    • ASTM International, West Conshohocken, PA, 9 pages
    • ASTM Standard D3454 Standard Test Method for Radium-226 in Water 2011, ASTM International, West Conshohocken, PA, 9 pages, www.astm.org. 10.1520/D3454-11.
    • (2011) Standard Test Method for Radium-226 in Water
  • 16
    • 84872172256 scopus 로고    scopus 로고
    • ASTM Standard D5811
    • ASTM International, West Conshohocken, PA, 6 pages
    • ASTM Standard D5811 Standard Test Method for Strontium-90 in Water 2008, ASTM International, West Conshohocken, PA, 6 pages, www.astm.org. 10.1520/D5811-08.
    • (2008) Standard Test Method for Strontium-90 in Water
  • 18
    • 84872176658 scopus 로고    scopus 로고
    • ASTM D6239 Standard Test Method for Uranium in Drinking Water by High-Resolution Alpha-Liquid-Scintillation Spectrometry
    • ASTM International, West Conshohocken, PA, 8 pages
    • ASTM D6239 Standard Test Method for Uranium in Drinking Water by High-Resolution Alpha-Liquid-Scintillation Spectrometry 2009, ASTM International, West Conshohocken, PA, 8 pages, www.astm.org. 10.1520/D6239-09.
    • (2009)
  • 20
    • 77952953878 scopus 로고    scopus 로고
    • Evaluation of procedures for determination of Ra-226 in water by α-particle spectrometry with emphasis on the recovery
    • Benedik L., Repinc U., Štrok M. Evaluation of procedures for determination of Ra-226 in water by α-particle spectrometry with emphasis on the recovery. Appl. Radiat. Isot. 2010, 68:1221-1225.
    • (2010) Appl. Radiat. Isot. , vol.68 , pp. 1221-1225
    • Benedik, L.1    Repinc, U.2    Štrok, M.3
  • 21
    • 77949263030 scopus 로고    scopus 로고
    • Chang-Kyu Kim, Determination of Pu isotopes by alpha spectrometry: a review of analytical methodology
    • Vajda N. Chang-Kyu Kim, Determination of Pu isotopes by alpha spectrometry: a review of analytical methodology. J. Radioanal. Nucl. Chem. 2009, 283:203-223.
    • (2009) J. Radioanal. Nucl. Chem. , vol.283 , pp. 203-223
    • Vajda, N.1
  • 22
    • 77953019688 scopus 로고    scopus 로고
    • 241Am isotope: a review of analytical methodology
    • 241Am isotope: a review of analytical methodology. J. Radioanal. Nucl. Chem. 2010, 284:341-366.
    • (2010) J. Radioanal. Nucl. Chem. , vol.284 , pp. 341-366
    • Vajda, N.1
  • 23
    • 33750210045 scopus 로고    scopus 로고
    • Natural radionuclides measurements in Lombardia drinking water by liquid scintillation counting
    • Maidstone (UK), Proc. 9th Symp
    • Forte M., Rusconi R., Di Caprio R.E., Bellinzona S., Sgorbati G. Natural radionuclides measurements in Lombardia drinking water by liquid scintillation counting. Environ. Radiochem. Anal. September 2002, 128-141. Maidstone (UK).
    • (2002) Environ. Radiochem. Anal. , pp. 128-141
    • Forte, M.1    Rusconi, R.2    Di Caprio, R.E.3    Bellinzona, S.4    Sgorbati, G.5
  • 27
    • 0000814061 scopus 로고    scopus 로고
    • Application of a hexapole collision and reaction cell in ICP-MS. Part I. Instrumental aspects and operational optimization, Fresenius'
    • Feldmann I., Jakubowski N., Stuwer D. Application of a hexapole collision and reaction cell in ICP-MS. Part I. Instrumental aspects and operational optimization, Fresenius'. J. Anal. Chem. 1999, 365:415-421.
    • (1999) J. Anal. Chem. , vol.365 , pp. 415-421
    • Feldmann, I.1    Jakubowski, N.2    Stuwer, D.3
  • 28
    • 0000621636 scopus 로고    scopus 로고
    • Application of a hexapole collision and reaction cell in ICP-MS. Part II. Analytical figures of merits and first applications, Fresenius'
    • Feldmann I., Jakubowski N., Thomas C., Stuwer D. Application of a hexapole collision and reaction cell in ICP-MS. Part II. Analytical figures of merits and first applications, Fresenius'. J. Anal. Chem. 1999, 365:422-428.
    • (1999) J. Anal. Chem. , vol.365 , pp. 422-428
    • Feldmann, I.1    Jakubowski, N.2    Thomas, C.3    Stuwer, D.4
  • 29
    • 27144460594 scopus 로고    scopus 로고
    • Improved calibration strategy for measurement of trace elements in biological and clinical whole blood reference materials via collision-cell inductively coupled plasma mass spectrometry
    • Christopher S.J., Day R.D., Bryan C.E., Turk G.C. Improved calibration strategy for measurement of trace elements in biological and clinical whole blood reference materials via collision-cell inductively coupled plasma mass spectrometry. J. Anal. At. Spectrom. 2005, 20:1035-1043.
    • (2005) J. Anal. At. Spectrom. , vol.20 , pp. 1035-1043
    • Christopher, S.J.1    Day, R.D.2    Bryan, C.E.3    Turk, G.C.4
  • 33
    • 0032670430 scopus 로고    scopus 로고
    • Application of double-focusing sector field ICP mass spectrometry with shielded torch using different nebulizers for ultratrace and precise isotope analysis of long-lived radionuclides
    • J. Sa. Becker, H.-J. Dietze, Application of double-focusing sector field ICP mass spectrometry with shielded torch using different nebulizers for ultratrace and precise isotope analysis of long-lived radionuclides, J. Anal. At. Spectrom. 14 (1999) 1493-1500.
    • (1999) J. Anal. At. Spectrom , vol.14 , pp. 1493-1500
    • Becker, J.S.1    Dietze, H.-J.2
  • 34
    • 84872173827 scopus 로고    scopus 로고
    • The ultratrace determination of iodine 129 in aqueous samples using the 7700x ICP-MS with oxygen reaction mode, Application Note, Agilent Technologies, Inc, June 30, 2011. Publication number 59908171EN.
    • K. Nakano, Y. Shikamori, N. Sugiyama, S. Kakuta, The ultratrace determination of iodine 129 in aqueous samples using the 7700x ICP-MS with oxygen reaction mode, Application Note, Agilent Technologies, Inc, June 30, 2011. Publication number 59908171EN.
    • Nakano, K.1    Shikamori, Y.2    Sugiyama, N.3    Kakuta, S.4
  • 35
    • 0035908608 scopus 로고    scopus 로고
    • Ultratrace and isotopic analysis of long-lived radionuclides by double-focusing sector field inductively coupled plasma mass spectrometry using direct liquid sample introduction
    • J.A. McLean, J. Sa. Becker, S.F. Boulyga, H.J. Dietze, A. Montaser, Ultratrace and isotopic analysis of long-lived radionuclides by double-focusing sector field inductively coupled plasma mass spectrometry using direct liquid sample introduction, Int. J. Mass Spectrom. 208 (2001) 193-204.
    • (2001) Int. J. Mass Spectrom , vol.208 , pp. 193-204
    • McLean, J.A.1    Becker, J.S.2    Boulyga, S.F.3    Dietze, H.J.4    Montaser, A.5
  • 36
    • 0142149148 scopus 로고    scopus 로고
    • Mass spectrometry of long-lived radionuclides, Spectrochim
    • Acta Part B 58
    • J. Sa. Becker, Mass spectrometry of long-lived radionuclides, Spectrochim. Acta Part B 58 (2003) 1757-1784.
    • (2003) , pp. 1757-1784
    • Becker, J.S.1
  • 37
    • 1842483831 scopus 로고    scopus 로고
    • Reduction of UH+ formation for 236U/238U isotope ratio measurements at ultratrace level in double focusing sector field ICP-MS using D2O as solvent, J. Anal. At. Spectrom.
    • M.V. Zoriy, L. Halicz, M.E. Ketterer, C. Pickhardt, P. Ostapczuk, J. Sa. Becker, Reduction of UH+ formation for 236U/238U isotope ratio measurements at ultratrace level in double focusing sector field ICP-MS using D2O as solvent, J. Anal. At. Spectrom. 19 (2004) 362-367.
    • (2004) , vol.19 , pp. 362-367
    • Zoriy, M.V.1    Halicz, L.2    Ketterer, M.E.3    Pickhardt, C.4    Ostapczuk, P.5    Becker, J.S.6
  • 38
    • 0035127497 scopus 로고    scopus 로고
    • Ultra-trace determination of 226-Ra in thermal waters by highsensitivity quadrupole ICP-mass spectrometry following selective extraction and concentration using radium-specific membrane disks, J. Anal. At. Spectrom
    • S. Joannon, C. Pin, Ultra-trace determination of 226-Ra in thermal waters by highsensitivity quadrupole ICP-mass spectrometry following selective extraction and concentration using radium-specific membrane disks, J. Anal. At. Spectrom. 16 (2001) 32-37.
    • (2001) , vol.16 , pp. 32-37
    • Joannon, S.1    Pin, C.2
  • 40
    • 84872171339 scopus 로고    scopus 로고
    • Determinazione di elementi a livello di traccia e di ultratraccia in campioni di acque
    • C. Minoia, M. Bettinelli, A. Ronchi, S. Spezia Applicazioni dell'ICP-MS nel Laboratorio Chimico e Tossicologico, Morgan Edizioni Tecniche
    • M. Bettinelli, S. Spezia, G. Bizzarri, Determinazione di elementi a livello di traccia e di ultratraccia in campioni di acque, in: C. Minoia, M. Bettinelli, A. Ronchi, S. Spezia Applicazioni dell'ICP-MS nel Laboratorio Chimico e Tossicologico, Morgan Edizioni Tecniche, 2000, pp. 265-296.
    • (2000) , pp. 265-296
    • Bettinelli, M.1    Spezia, S.2    Bizzarri, G.3
  • 41
    • 4344694270 scopus 로고    scopus 로고
    • Determination of thorium and light rare-earth elements in soil water and its high molecular mass organic fractions by inductively coupled plasma mass spectrometry and on-line-coupled size-exclusion chromatography, Anal. Bioanal. Chem.
    • E.A. Casartelli, N. Miekeley, Determination of thorium and light rare-earth elements in soil water and its high molecular mass organic fractions by inductively coupled plasma mass spectrometry and on-line-coupled size-exclusion chromatography, Anal. Bioanal. Chem. 377 (2003) 58-64.
    • (2003) , vol.377 , pp. 58-64
    • Casartelli, E.A.1    Miekeley, N.2
  • 42
    • 0036253604 scopus 로고    scopus 로고
    • Determination of uranium 235, uranium 238 and thorium 232 in urine by magnetic sector inductively coupled plasmamass spectrometry
    • R.S. Pappas, B.G. Ting, J.M. Jarrett, D.C. Paschal, S.P. Caudill, D.T. Miller, Determination of uranium 235, uranium 238 and thorium 232 in urine by magnetic sector inductively coupled plasmamass spectrometry, J. Anal. At. Spectrom. 17 (2002) 131-134.
    • (2002) J. Anal. At. Spectrom , vol.17 , pp. 131-134
    • Pappas, R.S.1    Ting, B.G.2    Jarrett, J.M.3    Paschal, D.C.4    Caudill, S.P.5    Miller, D.T.6
  • 43
    • 14844347963 scopus 로고    scopus 로고
    • Inductively coupled plasma mass spectrometry (ICP-MS) and laser ablation ICP-MS for isotope analysis of long-lived radionuclides International, J. Mass Spectrom.
    • J. Sa. Becker, Inductively coupled plasma mass spectrometry (ICP-MS) and laser ablation ICP-MS for isotope analysis of long-lived radionuclides International, J. Mass Spectrom. 242 (2005) 183-195.
    • (2005) , vol.242 , pp. 183-195
    • Becker, J.S.1
  • 44
    • 7544244254 scopus 로고    scopus 로고
    • Determination of uraniumand thoriumat trace and ultratrace levels in urine by laser ablation ICP MS, At. Spectrosc.
    • J. Sa. Becker, M. Burow, M. Zoriy, C. Pickhardt, P. Ostapczuk, R. Hille, Determination of uraniumand thoriumat trace and ultratrace levels in urine by laser ablation ICP MS, At. Spectrosc. 25 (2004) 197-202.
    • (2004) , vol.25 , pp. 197-202
    • Becker, J.S.1    Burow, M.2    Zoriy, M.3    Pickhardt, C.4    Ostapczuk, P.5    Hille, R.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.