메뉴 건너뛰기




Volumn 59, Issue 1, 2013, Pages 75-80

Initial experience with a juvenile sheep model for evaluation of the pediatric intracorporeal ventricular assist services

Author keywords

animal model; left ventricular assist devices; pediatric

Indexed keywords

ACTIVATED CLOTTING TIME; ANIMAL MODEL; ANTICOAGULATION THERAPY; BLOOD PUMP; CARDIOPULMONARY BYPASS; CLINICAL APPLICATION; GASTROINTESTINAL BLEEDING; IN-VIVO EXPERIMENTS; LEFT VENTRICLES; PEDIATRIC VENTRICULAR ASSIST DEVICE; RENAL FAILURE; SHEEP MODEL; SOURCE MATERIAL; WEIGHT LOSS;

EID: 84872171913     PISSN: 10582916     EISSN: 1538943X     Source Type: Journal    
DOI: 10.1097/MAT.0b013e31827986fe     Document Type: Article
Times cited : (7)

References (13)
  • 1
    • 50249171777 scopus 로고    scopus 로고
    • Registry of the international society for heart and lung transplantation: Eleventh offi¬cial pediatric heart transplantation reportY2008
    • Kirk R, Edwards LB, Aurora P, et al: Registry of the International Society for Heart and Lung Transplantation: Eleventh offi¬cial pediatric heart transplantation reportY2008. J Heart Lung Transplant 27: 970-977, 2008.
    • (2008) J Heart Lung Transplant , vol.27 , pp. 970-977
    • Kirk, R.1    Edwards, L.B.2    Aurora, P.3
  • 2
    • 61549112147 scopus 로고    scopus 로고
    • Waiting list mortal¬ity among children listed for heart transplantation in the United States
    • Almond CS, Thiagarajan RR, Piercey GE, et al: Waiting list mortal¬ity among children listed for heart transplantation in the United States. Circulation 119: 717-727, 2009.
    • (2009) Circulation , vol.119 , pp. 717-727
    • Almond, C.S.1    Thiagarajan, R.R.2    Piercey, G.E.3
  • 3
    • 77957126904 scopus 로고    scopus 로고
    • Use of ventricular assist devices in children across the United States: Analysis of 7.5 mil¬lion pediatric hospitalizations
    • discussion 1318
    • Morales DL, Zafar F, Rossano JW, et al: Use of ventricular assist devices in children across the United States: Analysis of 7.5 mil¬lion pediatric hospitalizations. Ann Thorac Surg 90: 1313-8; discussion 1318, 2010.
    • (2010) Ann Thorac Surg , vol.90 , pp. 1313-1318
    • Morales, D.L.1    Zafar, F.2    Rossano, J.W.3
  • 4
    • 33644854087 scopus 로고    scopus 로고
    • The national heart, lung, and blood institute pediatric circulatory support program
    • DOI 10.1161/CIRCULATIONAHA.105.571422, PII 0000301720060103000023
    • Baldwin JT, Borovetz HS, Duncan BW, et al: The National Heart, Lung, and Blood Institute Pediatric Circulatory Support Program. Circulation 113: 147-155, 2006. (Pubitemid 43958501)
    • (2006) Circulation , vol.113 , Issue.1 , pp. 147-155
    • Baldwin, J.T.1    Borovetz, H.S.2    Duncan, B.W.3    Gartner, M.J.4    Jarvik, R.K.5    Weiss, W.J.6    Hoke, T.R.7
  • 5
    • 78649940536 scopus 로고    scopus 로고
    • Children are not necessarily quot;small" adults: The grow¬ing field of miniaturized mechanical circulatory support
    • Griffith BP: Children are not necessarily "small" adults: The grow¬ing field of miniaturized mechanical circulatory support. J Heart Lung Transplant 30: 9-11, 2011.
    • (2011) J Heart Lung Transplant , vol.30 , pp. 9-11
    • Griffith, B.P.1
  • 6
    • 62449095278 scopus 로고    scopus 로고
    • Animal models for pediatric circulatory support device pre-clinical testing national heart, lung, and blood institute pediatric assist device contractor's meeting animal models working group
    • Animal Models Working Group
    • Carney E, Litwak K, Weiss W; Animal Models Working Group: Animal models for pediatric circulatory support device pre-clinical testing: National Heart, Lung, and Blood Institute Pediatric Assist Device Contractor's Meeting Animal Models Working Group. ASAIO J 55: 6-9, 2009.
    • (2009) ASAIO J , vol.55 , pp. 6-9
    • Carney, E.1    Litwak, K.2    Weiss, W.3
  • 7
    • 67650799652 scopus 로고    scopus 로고
    • In vivo preclinical anticoagulation regi¬mens after implantation of ventricular assist devices
    • Saeed D, Fukamachi K: In vivo preclinical anticoagulation regi¬mens after implantation of ventricular assist devices. Artif Organs 33: 491-503, 2009.
    • (2009) Artif Organs , vol.33 , pp. 491-503
    • Saeed, D.1    Fukamachi, K.2
  • 8
    • 0036630272 scopus 로고    scopus 로고
    • Evaluation of platelet and coagulation function in different animal species using the Xylum Clot Signature Analyzer
    • Sato M, Harasaki H: Evaluation of platelet and coagulation func¬tion in different animal species using the xylum clot signature analyzer. ASAIO J 48: 360-364, 2002. (Pubitemid 35006964)
    • (2002) ASAIO Journal , vol.48 , Issue.4 , pp. 360-364
    • Sato, M.1    Harasaki, H.2
  • 9
    • 33744967067 scopus 로고    scopus 로고
    • Total heart replacement using dual intracorporeal continuous-flow pumps in a chronic bovine model: A feasibility study
    • DOI 10.1097/01.mat.0000196827.61241.07, PII 0000248020060300000005
    • Frazier OH, Tuzun E, Cohn WE, Conger JL, Kadipasaoglu KA: Total heart replacement using dual intracorporeal continuous-flow pumps in a chronic bovine model: A feasibility study. ASAIO J 52: 145-149, 2006. (Pubitemid 44309496)
    • (2006) ASAIO Journal , vol.52 , Issue.2 , pp. 145-149
    • Frazier, O.H.1    Tuzun, E.2    Cohn, W.E.3    Conger, J.L.4    Kadipasaoglu, K.A.5
  • 12
    • 77954956547 scopus 로고    scopus 로고
    • In vivo experience of the child-size pediatric Jarvik 2000 heart: Update
    • Gibber M, Wu ZJ, Chang WB, et al: In vivo experience of the child-size pediatric Jarvik 2000 heart: update. ASAIO J 56: 369-376, 2010.
    • (2010) ASAIO J , vol.56 , pp. 369-376
    • Gibber, M.1    Wu, Z.J.2    Chang, W.B.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.