메뉴 건너뛰기




Volumn 8452, Issue , 2012, Pages

Performance of the SCUBA-2 dry dilution refrigerator: 4 Years of operation at the JCMT

Author keywords

Dry dilution refrigerator; SCUBA 2; Submillimetre astronomy; TES

Indexed keywords

BASE TEMPERATURE; COMMISSIONING PHASE; CONTINUOUS OPERATION; COOLING POWER; CRYOCOOLERS; DETECTOR ARRAYS; DILUTION REFRIGERATOR; LIQUID HELIUM; PULSE TUBES; SCUBA-2; SQUID AMPLIFIERS; SUBMILLIMETRE; SUBMILLIMETRE ASTRONOMY; TES;

EID: 84872082362     PISSN: 0277786X     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1117/12.926540     Document Type: Conference Paper
Times cited : (6)

References (5)
  • 1
    • 84871561739 scopus 로고    scopus 로고
    • A new era of wide-field submillimetre imaging: On-sky performance of SCUBA-2
    • J. Dempsey et al., A new era of wide-field submillimetre imaging: on-sky performance of SCUBA-2. Proc. SPIE 8452 (2012)
    • (2012) Proc. SPIE , vol.8452
    • Dempsey, J.1
  • 2
    • 84872072398 scopus 로고    scopus 로고
    • Scaling the summit of the submillimetre: Instrument performance of SCUBA-2
    • D. Bintley et al., Scaling the summit of the submillimetre: instrument performance of SCUBA-2. Proc. SPIE 8452 (2012)
    • (2012) Proc. SPIE , vol.8452
    • Bintley, D.1
  • 3
    • 52249097611 scopus 로고    scopus 로고
    • Performance of the SCUBA-2 dilution refrigerator
    • M. Hollister, A. L. Woodcraft, W. S. Holland et al., Performance of the SCUBA-2 dilution refrigerator, Proc SPIE, 7020 (2008)
    • (2008) Proc SPIE , vol.7020
    • Hollister, M.1    Woodcraft, A.L.2    Holland, W.S.3
  • 4
    • 0036474899 scopus 로고    scopus 로고
    • 3He 4He dilution refrigerator with pulse-tube refrigerator precooling
    • K. Uhlig, 3He 4He dilution refrigerator with pulse-tube refrigerator precooling, Cryogenics 42, 73-77 (2002)
    • (2002) Cryogenics , vol.42 , pp. 73-77
    • Uhlig, K.1
  • 5
    • 43249111426 scopus 로고    scopus 로고
    • Condensation stage of a pulse tube pre-cooled dilution refrigerator
    • K. Uhlig, Condensation stage of a pulse tube pre-cooled dilution refrigerator, Cryogenics, 48, 138-141 (2008)
    • (2008) Cryogenics , vol.48 , pp. 138-141
    • Uhlig, K.1