메뉴 건너뛰기




Volumn 38, Issue 12, 2012, Pages 2026-2031

The repeatability of Stewart's parameters and anion gap in a cohort of critically ill adult patients

Author keywords

Anion gap; Least significant change; Repeatability; Smallest detectable difference; Stewart's parameters; Within coefficient of variation

Indexed keywords

ALBUMIN; ANION;

EID: 84872059488     PISSN: 03424642     EISSN: 14321238     Source Type: Journal    
DOI: 10.1007/s00134-012-2679-9     Document Type: Article
Times cited : (3)

References (18)
  • 1
    • 0345117164 scopus 로고    scopus 로고
    • Acid-base and electrolyte analysis in critically ill patients: Are we ready for the new millennium?
    • DOI 10.1097/00075198-200312000-00002
    • Gunnerson KJ, Kellum JA (2003) Aidbase and electrolyte analysis in critically ill patients: are we ready for the new millennium? Curr Opin Crit Care 9:468-473 (Pubitemid 37518645)
    • (2003) Current Opinion in Critical Care , vol.9 , Issue.6 , pp. 468-473
    • Gunnerson, K.J.1    Kellum, J.A.2
  • 4
    • 0025913301 scopus 로고
    • The role of serum proteins in acid-base equilibria
    • Figge J, Rossing TH, Fencl V (1991) The role of serum proteins in acid-base equilibria. J Lab Clin Med 117:453-467
    • (1991) J Lab Clin Med , vol.117 , pp. 453-467
    • Figge, J.1    Rossing, T.H.2    Fencl, V.3
  • 5
    • 0026476264 scopus 로고
    • Serum proteins and acid-base equilibria: A follow-up
    • Figge J, Mydosh T, Fencl V (1992) Serum proteins and acid-base equilibria: a follow-up. J Lab Clin Med 120:713-719
    • (1992) J Lab Clin Med , vol.120 , pp. 713-719
    • Figge, J.1    Mydosh, T.2    Fencl, V.3
  • 6
    • 34248650685 scopus 로고    scopus 로고
    • Conventional or physicochemical approach in intensive care unit patients with metabolic acidosis
    • Moviat M, Van Haren F, van der Hoeven H (2003) Conventional or physicochemical approach in intensive care unit patients with metabolic acidosis. Crit Care 7:R41-R45
    • (2003) Crit Care , vol.7
    • Moviat, M.1    Van Haren, F.2    Van Der Hoeven, H.3
  • 7
    • 67650835574 scopus 로고    scopus 로고
    • Acid-base disorders evaluation in critically ill patients: We can improve our diagnostic ability
    • Boniatti MM, Cardoso PR, Castilho RK, Vieira SR (2009) Acid-base disorders evaluation in critically ill patients: we can improve our diagnostic ability. Intensive Care Med 35:1377-1382
    • (2009) Intensive Care Med , vol.35 , pp. 1377-1382
    • Boniatti, M.M.1    Cardoso, P.R.2    Castilho, R.K.3    Vieira, S.R.4
  • 9
    • 19744364550 scopus 로고    scopus 로고
    • Uncertainty of measurement in quantitative medical testing: A laboratory implementation guide
    • White GH, Farrance I (2004) Uncertainty of measurement in quantitative medical testing: a laboratory implementation guide. Clin Biochem Rev 25:S1-24
    • (2004) Clin Biochem Rev , vol.25
    • White, G.H.1    Farrance, I.2
  • 10
    • 0029063868 scopus 로고
    • Strong ion gap: A methodology for exploring unexplained anions
    • Kellum JA, Kramer DJ, Pinsky MR (1995) Strong ion gap: a methodology for exploring unexplained anions. J Crit Care 10:51-55
    • (1995) J Crit Care , vol.10 , pp. 51-55
    • Kellum, J.A.1    Kramer, D.J.2    Pinsky, M.R.3
  • 11
    • 0031734311 scopus 로고    scopus 로고
    • Anion gap and hypoalbuminemia
    • Figge J, Jabor A, Kazda A, Fencl V (1998) Anion gap and hypoalbuminemia. Crit Care Med 26:1807-1810 (Pubitemid 28527690)
    • (1998) Critical Care Medicine , vol.26 , Issue.11 , pp. 1807-1810
    • Fencl, V.1
  • 12
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • PII S0140673686908378
    • Bland JM, Altman DG (1986) Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1:307-310 (Pubitemid 16134762)
    • (1986) Lancet , vol.1 , Issue.8476 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2
  • 13
    • 48249153186 scopus 로고
    • Intraclass correlations: Uses in assessing rater reliability
    • Shrout PE, Fleiss JL (1979) Intraclass correlations: uses in assessing rater reliability. Psychol Bull 86:420-428
    • (1979) Psychol Bull , vol.86 , pp. 420-428
    • Shrout, P.E.1    Fleiss, J.L.2
  • 15
    • 0344131882 scopus 로고    scopus 로고
    • Monitoring skeletal changes by radiological techniques
    • Glüer CC (1999) Monitoring skeletal changes by radiological techniques. J Bone Miner Res 14:1952-1962
    • (1999) J Bone Miner Res , vol.14 , pp. 1952-1962
    • Glüer, C.C.1
  • 16
    • 0037407607 scopus 로고    scopus 로고
    • Comparison of point-of-care versus central laboratory measurement of electrolyte concentrations on calculations of the anion gap and the strong ion difference
    • DOI 10.1097/00000542-200305000-00009
    • Morimatsu H, Rocktäschel J, Bellomo R, Uchino S, Goldsmith D, Gutteridge G (2003) Comparison of point-of-care versus central laboratory measurement of electrolyte concentrations on calculations of the anion gap and the strong ion difference. Anesthesiology 98:1077-1084 (Pubitemid 36520194)
    • (2003) Anesthesiology , vol.98 , Issue.5 , pp. 1077-1084
    • Morimatsu, H.1    Rocktaschel, J.2    Bellomo, R.3    Uchino, S.4    Goldsmith, D.5    Gutteridge, G.6
  • 18
    • 0025048927 scopus 로고
    • A note on the use of the intraclass correlation coefficient in the evaluation of agreement between two methods of measurement
    • DOI 10.1016/0010-4825(90)90013-F
    • Bland JM, Altman DG (1990) A note on the use of the intraclass correlation coefficient in the evaluation of agreement between two methods of measurement. Comput Biol Med 20:337-340 (Pubitemid 20350333)
    • (1990) Computers in Biology and Medicine , vol.20 , Issue.5 , pp. 337-340
    • Bland, J.M.1    Altman, D.G.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.