메뉴 건너뛰기




Volumn 82, Issue 2, 2013, Pages

A reduced contrast volume acquisition regimen based on cardiovascular dynamics improves visualisation of head and neck vasculature with carotid MDCT angiography

Author keywords

Carotid CT angiography; Contrast media; Neuroradiology; Stroke

Indexed keywords

ADULT; AGED; ARTICLE; CAROTID ARTERIOGRAPHY; COMPUTED TOMOGRAPHIC ANGIOGRAPHY; COMPUTED TOMOGRAPHY SCANNER; CONTRAST ENHANCEMENT; CONTROLLED STUDY; FEMALE; HUMAN; MAJOR CLINICAL STUDY; MALE; MULTIDETECTOR COMPUTED TOMOGRAPHY; PRIORITY JOURNAL; RECEIVER OPERATING CHARACTERISTIC;

EID: 84871924120     PISSN: 0720048X     EISSN: 18727727     Source Type: Journal    
DOI: 10.1016/j.ejrad.2012.09.016     Document Type: Article
Times cited : (19)

References (20)
  • 2
    • 3242803772 scopus 로고    scopus 로고
    • What is the best hydration regimen to prevent contrast media-induced nephrotoxicity?
    • B.D. Bader, E.D. Berger, and M.B. Heede What is the best hydration regimen to prevent contrast media-induced nephrotoxicity? Clinical Nephrology 62 1 2004 1 7
    • (2004) Clinical Nephrology , vol.62 , Issue.1 , pp. 1-7
    • Bader, B.D.1    Berger, E.D.2    Heede, M.B.3
  • 4
    • 0842302434 scopus 로고    scopus 로고
    • Non-invasive 16-row multislice CT coronary angiography: Usefulness of saline chaser
    • F. Cademartiri, N. Mollet, and A. van der Lugt Non-invasive 16-row multislice CT coronary angiography: usefulness of saline chaser European Radiology 14 2 2004 178 183
    • (2004) European Radiology , vol.14 , Issue.2 , pp. 178-183
    • Cademartiri, F.1    Mollet, N.2    Van Der Lugt, A.3
  • 5
    • 2442644258 scopus 로고    scopus 로고
    • Multisection CT angiography compared with catheter angiography in diagnosing vertebral artery dissection
    • C.J. Chen, Y.C. Tseng, T.H. Lee, H.L. Hsu, and L.C. See Multisection CT angiography compared with catheter angiography in diagnosing vertebral artery dissection American Journal of Neuroradiology 25 5 2004 769 774
    • (2004) American Journal of Neuroradiology , vol.25 , Issue.5 , pp. 769-774
    • Chen, C.J.1    Tseng, Y.C.2    Lee, T.H.3    Hsu, H.L.4    See, L.C.5
  • 6
    • 27144471343 scopus 로고    scopus 로고
    • Sixteen-detector row CT angiography of carotid arteries: Comparison of different volumes of contrast material with and without a bolus chaser
    • C. de Monye, F. Cademartiri, T.T. de Weert, D.A. Siepman, D.W. Dippel, and A. van Der Lugt Sixteen-detector row CT angiography of carotid arteries: comparison of different volumes of contrast material with and without a bolus chaser Radiology 237 2 2005 555 562
    • (2005) Radiology , vol.237 , Issue.2 , pp. 555-562
    • De Monye, C.1    Cademartiri, F.2    De Weert, T.T.3    Siepman, D.A.4    Dippel, D.W.5    Van Der Lugt, A.6
  • 7
    • 0842345513 scopus 로고    scopus 로고
    • Use of high-concentration contrast media in multiple-detector-row CT: Principles and rationale
    • D. Fleischmann Use of high-concentration contrast media in multiple-detector-row CT: principles and rationale European Radiology 13 Suppl. 5 2003 M14 M20
    • (2003) European Radiology , vol.13 , Issue.SUPPL. 5
    • Fleischmann, D.1
  • 8
    • 77953034723 scopus 로고    scopus 로고
    • CT angiography covering both cervical and cerebral arteries using high iodine concentration contrast material with dose reduction on a 16 multidetector-row system
    • A. Fujikawa, K. Tsuchiya, M. Imai, and T. Nitatori CT angiography covering both cervical and cerebral arteries using high iodine concentration contrast material with dose reduction on a 16 multidetector-row system Neuroradiology 52 4 2010 291 295
    • (2010) Neuroradiology , vol.52 , Issue.4 , pp. 291-295
    • Fujikawa, A.1    Tsuchiya, K.2    Imai, M.3    Nitatori, T.4
  • 9
    • 0942298139 scopus 로고    scopus 로고
    • Contrast-enhanced magnetic resonance angiography of the carotid arteries: Influence of injection rates and volumes on arterial-venous transit time
    • T. Herold, C. Paetzel, and M. Volk Contrast-enhanced magnetic resonance angiography of the carotid arteries: influence of injection rates and volumes on arterial-venous transit time Investigative Radiology 39 2 2004 65 72
    • (2004) Investigative Radiology , vol.39 , Issue.2 , pp. 65-72
    • Herold, T.1    Paetzel, C.2    Volk, M.3
  • 10
    • 19144371567 scopus 로고    scopus 로고
    • A comparison of the Dorfman-Berbaum-Metz and Obuchowski-Rockette methods for receiver operating characteristic (ROC) data
    • S.L. Hillis, N.A. Obuchowski, K.M. Schartz, and K.S. Berbaum A comparison of the Dorfman-Berbaum-Metz and Obuchowski-Rockette methods for receiver operating characteristic (ROC) data Statistics in Medicine 24 10 2005 1579 1607
    • (2005) Statistics in Medicine , vol.24 , Issue.10 , pp. 1579-1607
    • Hillis, S.L.1    Obuchowski, N.A.2    Schartz, K.M.3    Berbaum, K.S.4
  • 11
    • 75749153024 scopus 로고    scopus 로고
    • Sixty-four-section multidetector CT angiography of carotid arteries: A systematic analysis of image quality and artifacts
    • J.J. Kim, W.P. Dillon, C.M. Glastonbury, J.M. Provenzale, and M. Wintermark Sixty-four-section multidetector CT angiography of carotid arteries: a systematic analysis of image quality and artifacts American Journal of Neuroradiology 31 1 2010 91 99
    • (2010) American Journal of Neuroradiology , vol.31 , Issue.1 , pp. 91-99
    • Kim, J.J.1    Dillon, W.P.2    Glastonbury, C.M.3    Provenzale, J.M.4    Wintermark, M.5
  • 13
    • 0029047087 scopus 로고
    • A proposed blood circulation model for reference man
    • R.W. Leggett, and L.R. Williams A proposed blood circulation model for reference man Health Physics 69 2 1995 187 201
    • (1995) Health Physics , vol.69 , Issue.2 , pp. 187-201
    • Leggett, R.W.1    Williams, L.R.2
  • 14
    • 77649126524 scopus 로고    scopus 로고
    • Heart disease and stroke statistics - 2010 update: A report from the American Heart Association
    • D. Lloyd-Jones, R.J. Adams, and T.M. Brown Heart disease and stroke statistics - 2010 update: a report from the American Heart Association Circulation 121 7 2010 e46 e215
    • (2010) Circulation , vol.121 , Issue.7
    • Lloyd-Jones, D.1    Adams, R.J.2    Brown, T.M.3
  • 15
    • 0030661687 scopus 로고    scopus 로고
    • Acute renal failure after coronary intervention: Incidence, risk factors, and relationship to mortality
    • P.A. McCullough, R. Wolyn, L.L. Rocher, R.N. Levin, and W.W. O'Neill Acute renal failure after coronary intervention: incidence, risk factors, and relationship to mortality American Journal of Medicine 103 5 1997 368 375
    • (1997) American Journal of Medicine , vol.103 , Issue.5 , pp. 368-375
    • McCullough, P.A.1    Wolyn, R.2    Rocher, L.L.3    Levin, R.N.4    O'Neill, W.W.5
  • 16
    • 34547409756 scopus 로고    scopus 로고
    • Multidetector-row CT angiography in the study of atherosclerotic carotid arteries
    • L. Saba, R. Sanfilippo, R. Pirisi, L. Pascalis, R. Montisci, and G. Mallarini Multidetector-row CT angiography in the study of atherosclerotic carotid arteries Neuroradiology 49 8 2007 623 637
    • (2007) Neuroradiology , vol.49 , Issue.8 , pp. 623-637
    • Saba, L.1    Sanfilippo, R.2    Pirisi, R.3    Pascalis, L.4    Montisci, R.5    Mallarini, G.6
  • 17
    • 12144266434 scopus 로고    scopus 로고
    • Latest techniques in head and neck CT angiography
    • B. Schuknecht Latest techniques in head and neck CT angiography Neuroradiology 46 Suppl. 2 2004 s208 s213
    • (2004) Neuroradiology , vol.46 , Issue.SUPPL. 2
    • Schuknecht, B.1
  • 18
    • 79961209366 scopus 로고    scopus 로고
    • A systematic review of stenting and angioplasty of symptomatic extracranial vertebral artery stenosis
    • A.N. Stayman, R.G. Nogueira, and R. Gupta A systematic review of stenting and angioplasty of symptomatic extracranial vertebral artery stenosis Stroke 42 8 2011 2212 2216
    • (2011) Stroke , vol.42 , Issue.8 , pp. 2212-2216
    • Stayman, A.N.1    Nogueira, R.G.2    Gupta, R.3
  • 19
    • 54349129560 scopus 로고    scopus 로고
    • Comparison of 40 and 60 milliliters of contrast in assessment of the carotid artery by computed tomography angiography
    • N. Takeyama, Y. Ohgiya, and H. Itokawa Comparison of 40 and 60 milliliters of contrast in assessment of the carotid artery by computed tomography angiography Acta Radiologica 49 9 2008 1068 1078
    • (2008) Acta Radiologica , vol.49 , Issue.9 , pp. 1068-1078
    • Takeyama, N.1    Ohgiya, Y.2    Itokawa, H.3
  • 20
    • 34748824211 scopus 로고    scopus 로고
    • Effects of right- versus left-arm injections of contrast material on computed tomography of the head and neck
    • S.Y. You, D.Y. Yoon, and C.S. Choi Effects of right- versus left-arm injections of contrast material on computed tomography of the head and neck Journal of Computer Assisted Tomography 31 5 2007 677 681
    • (2007) Journal of Computer Assisted Tomography , vol.31 , Issue.5 , pp. 677-681
    • You, S.Y.1    Yoon, D.Y.2    Choi, C.S.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.