메뉴 건너뛰기




Volumn 946, Issue , 2013, Pages 1-13

Detection of mycoplasma contaminations

Author keywords

Bacteria; Cell lines; Contamination; Mycoplasma; PCR

Indexed keywords

MYCOPLASMA;

EID: 84871868877     PISSN: 10643745     EISSN: None     Source Type: Book Series    
DOI: 10.1007/978-1-62703-128-8_1     Document Type: Article
Times cited : (55)

References (8)
  • 1
    • 0035465472 scopus 로고    scopus 로고
    • Prevention of mycoplasma contamination in leukemia-lym-phoma cell lines
    • Uphoff CC, Drexler HG (2001) Prevention of mycoplasma contamination in leukemia-lym-phoma cell lines. Hum Cell 14:244-247
    • (2001) Hum Cell , vol.14 , pp. 244-247
    • Uphoff, C.C.1    Drexler, H.G.2
  • 2
    • 0037883756 scopus 로고    scopus 로고
    • Mycoplasma contamination of cell cultures: Incidence, sources, effects, detection, elimination, prevention
    • Drexler HG, Uphoff CC (2002) Mycoplasma contamination of cell cultures: incidence, sources, effects, detection, elimination, prevention. Cytotechnology 39:23-38
    • (2002) Cytotechnology , vol.39 , pp. 23-38
    • Drexler, H.G.1    Uphoff, C.C.2
  • 4
    • 0036102188 scopus 로고    scopus 로고
    • Comparative PCR analysis for detection of mycoplasma infections in continuous cell lines
    • Uphoff CC, Drexler HG (2002) Comparative PCR analysis for detection of mycoplasma infections in continuous cell lines. In Vitro Cell Dev Biol Animal 38:79-85
    • (2002) Vitro Cell Dev Biol Animal , vol.38 , pp. 79-85
    • Uphoff, C.C.1    Drexler, H.G.2
  • 5
    • 84871907776 scopus 로고    scopus 로고
    • European Pharmacopoeia suppl. 5.6. Council of Europe, Strasbourg, France
    • European Pharmacopoeia (2008) General chapter 2.6.7., Mycoplasmas, suppl. 5.6. Council of Europe, Strasbourg, France
    • (2008) General Chapter 2.6.7., Mycoplasmas
  • 6
    • 0033287840 scopus 로고    scopus 로고
    • Detection of mycoplasma contamination in cell cultures by PCR analysis
    • Uphoff CC, Drexler HG (1999) Detection of mycoplasma contamination in cell cultures by PCR analysis. Hum Cell 12:229-236
    • (1999) Hum Cell , vol.12 , pp. 229-236
    • Uphoff, C.C.1    Drexler, H.G.2
  • 8
    • 0027228144 scopus 로고
    • Specificity and sensitivity of polymerase chain reaction (PCR) in comparison with other methods for the detection of mycoplasma contamination in cell lines
    • Hopert A, Uphoff CC, Wirth M, Hauser H, Drexler HG (1993) Specificity and sensitivity of polymerase chain reaction (PCR) in comparison with other methods for the detection of mycoplasma contamination in cell lines. J Immunol Methods 164:91-100
    • (1993) J Immunol Methods , vol.164 , pp. 91-100
    • Hopert, A.1    Uphoff, C.C.2    Wirth, M.3    Hauser, H.4    Drexler, H.G.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.