메뉴 건너뛰기




Volumn 49, Issue 1, 2013, Pages 309-315

Open gradient magnetic red blood cell sorter evaluation on model cell mixtures

Author keywords

Biomagnetics; cellular biophysics; fluid dynamics; magnetic susceptibility; permanent magnets

Indexed keywords

ADVANCED DESIGNS; BIOLOGICAL CELLS; BIOMAGNETICS; CELL MIXTURES; CELLULAR BIOPHYSICS; CIRCULATING TUMOR CELLS; DIAGNOSTIC APPLICATIONS; DIAGNOSTIC TESTS; EMERGING APPLICATIONS; IMMUNOMAGNETIC CELL SEPARATION; IRON CONTENT; LABEL FREE; LOW COSTS; MAGNETIC CELL SEPARATIONS; MAGNETIC FORCE; MAGNETIC NANOPARTICLES; MICRO-SCALES; NORMAL MEAN; POTENTIAL APPLICATIONS; PROGENITOR CELL; RED BLOOD CELL; TOTAL ANALYTICAL SYSTEMS; WHITE BLOOD CELLS; WHOLE BLOOD;

EID: 84871822725     PISSN: 00189464     EISSN: None     Source Type: Journal    
DOI: 10.1109/TMAG.2012.2225098     Document Type: Article
Times cited : (19)

References (42)
  • 1
    • 33947634515 scopus 로고    scopus 로고
    • Magnetophoretic separation of blood cells at the microscale
    • DOI 10.1088/0022-3727/40/5/001, PII S0022372707309364, 001
    • E. P. Furlani, "Magnetophoretic separation of blood cells at the microscale, " J. Phys. D, vol. 40, pp. 1313-1319, 2007. (Pubitemid 46485729)
    • (2007) Journal of Physics D: Applied Physics , vol.40 , Issue.5 , pp. 1313-1319
    • Furlani, E.P.1
  • 2
    • 84865297464 scopus 로고    scopus 로고
    • On-chip bioanalysis with magnetic particles
    • N. Pamme, "On-chip bioanalysis with magnetic particles, " Curr. Opin. Chem. Biol., vol. 16, pp. 436-443, 2012.
    • (2012) Curr. Opin. Chem. Biol , vol.16 , pp. 436-443
    • Pamme, N.1
  • 3
    • 77957348327 scopus 로고    scopus 로고
    • Six-stage cascade paramagnetic mode magnetophoretic separation system for human blood samples
    • Y. Jung, Y. Choi, K. H. Ham, and A. B. Frazier, "Six-stage cascade paramagnetic mode magnetophoretic separation system for human blood samples, " Biomed. Microdevices, vol. 12, pp. 637-645, 2010.
    • (2010) Biomed. Microdevices , vol.12 , pp. 637-645
    • Jung, Y.1    Choi, Y.2    Ham, K.H.3    Frazier, A.B.4
  • 4
    • 84859376767 scopus 로고    scopus 로고
    • Label-free separation using a tunable magnetophoretic repulsion force
    • F. Shen, H. Hwang, Y. K. Hahn, and J. K. Park, "Label-free separation using a tunable magnetophoretic repulsion force, " Anal. Chem., vol. 84, pp. 3075-3081, 2012.
    • (2012) Anal. Chem , vol.84 , pp. 3075-3081
    • Shen, F.1    Hwang, H.2    Hahn, Y.K.3    Park, J.K.4
  • 6
    • 0000094068 scopus 로고
    • The magnetic properties and structure of hemoglobin, oxyhemoglobin and carbonmonoxyhemoglobin
    • L. Pauling and C. D. Coryell, "The magnetic properties and structure of hemoglobin, oxyhemoglobin and carbonmonoxyhemoglobin, " Proc. Nat. Acad. Sci. USA, vol. 22, pp. 210-216, 1936.
    • (1936) Proc. Nat. Acad. Sci. USA , vol.22 , pp. 210-216
    • Pauling, L.1    Coryell, C.D.2
  • 10
    • 0035299150 scopus 로고    scopus 로고
    • Theoretical and experimental analysis of the accuracy and reproducibility of cell tracking velocimetry
    • DOI 10.1007/s003480000211
    • M. Nakamura, M. Zborowski, L. C. Lasky, S. Margel, and J. J. Chalmers, "Theoretical and experimental analysis of the accuracy and reproducibility of cell tracking velocimetry, " Exp. Fluids, vol. 30, pp. 371-380, 2001. (Pubitemid 32782557)
    • (2001) Experiments in Fluids , vol.30 , Issue.4 , pp. 371-380
    • Nakamura, M.1    Zborowski, M.2    Lasky, L.C.3    Margel, S.4    Chalmers, J.J.5
  • 11
    • 0000094069 scopus 로고
    • The magnetic properties of the hemochromogens and related substances
    • L. Pauling and C. Coryell, "The magnetic properties of the hemochromogens and related substances, " Proc. Nat. Acad. Sci. USA, vol. 22, pp. 159-163, 1936.
    • (1936) Proc. Nat. Acad. Sci. USA , vol.22 , pp. 159-163
    • Pauling, L.1    Coryell, C.2
  • 12
    • 0021177231 scopus 로고
    • Magnetic susceptibility of oxy-and carbonmonoxyhemoglobins
    • J. P. Savicki, G. Lang, and M. Ikeda-Saito, "Magnetic susceptibility of oxy-and carbonmonoxyhemoglobins, " Proc. Nat. Acad. Sci. USA, vol. 81, pp. 5417-5419, 1984.
    • (1984) Proc. Nat. Acad. Sci. USA , vol.81 , pp. 5417-5419
    • Savicki, J.P.1    Lang, G.2    Ikeda-Saito, M.3
  • 13
    • 0035095912 scopus 로고    scopus 로고
    • 2, and non-Lorentzian signal behavior
    • DOI 10.1002/mrm.1072
    • W. M. Spees, D. A. Yablonskiy, M. C. Oswood, and J. J. Ackerman, "Water proton MR properties of human blood at 1. 5 tesla: Magnetic susceptibility, T(1), T(2), T, non-Lorentzian signal behavior, " Magn. Reson. Med., vol. 45, pp. 533-542, 2001. (Pubitemid 32260072)
    • (2001) Magnetic Resonance in Medicine , vol.45 , Issue.4 , pp. 533-542
    • Spees, W.M.1    Yablonskiy, D.A.2    Oswood, M.C.3    Ackerman, J.J.H.4
  • 14
    • 56549113011 scopus 로고    scopus 로고
    • Differences in magnetically induced motion of diamagnetic, paramagnetic, superparamagnetic microparticles detected by cell tracking velocimetry
    • X. Jin, Y. Zhao, A. Richardson, L. Moore, P. S. Williams, M. Zborowski, and J. J. Chalmers, "Differences in magnetically induced motion of diamagnetic, paramagnetic, superparamagnetic microparticles detected by cell tracking velocimetry, " Analyst, vol. 133, pp. 1767-1775, 2008.
    • (2008) Analyst , vol.133 , pp. 1767-1775
    • Jin, X.1    Zhao, Y.2    Richardson, A.3    Moore, L.4    Williams, P.S.5    Zborowski, M.6    Chalmers, J.J.7
  • 15
    • 0037444539 scopus 로고    scopus 로고
    • Splitter imperfections in annular split-flow thin separation channels: Effect on nonspecific crossover
    • DOI 10.1021/ac020649h
    • P. S. Williams, L. R. Moore, J. J. Chalmers, and M. Zborowski, "Splitter imperfections in annular split-flow thin separation channels: Effect on nonspecific crossover, " Anal. Chem., vol. 75, pp. 1365-1373, 2003. (Pubitemid 36397168)
    • (2003) Analytical Chemistry , vol.75 , Issue.6 , pp. 1365-1373
    • Williams, P.S.1    Moore, L.R.2    Chalmers, J.J.3    Zborowski, M.4
  • 16
    • 0033199374 scopus 로고    scopus 로고
    • Flow rate optimization for the quadrupole magnetic cell sorter
    • P. S. Williams, M. Zborowski, and J. J. Chalmers, "Flow rate optimization for the quadrupole magnetic cell sorter, " Anal. Chem., vol. 71, pp. 3799-3807, 1999.
    • (1999) Anal. Chem , vol.71 , pp. 3799-3807
    • Williams, P.S.1    Zborowski, M.2    Chalmers, J.J.3
  • 18
    • 79251581577 scopus 로고    scopus 로고
    • Magnetic pressure as a scalar representation of field effects in magnetic suspensions
    • M. Zborowski, L. R. Moore, P. S. Williams, and J. J. Chalmers, "Magnetic pressure as a scalar representation of field effects in magnetic suspensions, " in Proc. Amer. Inst. Physics Conf., 2010, vol. 1311, pp. 111-117.
    • (2010) Proc. Amer. Inst. Physics Conf. , vol.1311 , pp. 111-117
    • Zborowski, M.1    Moore, L.R.2    Williams, P.S.3    Chalmers, J.J.4
  • 23
    • 0021208799 scopus 로고
    • Comparison of volume and surface mechanisms for magnetic filtration of blood cells
    • M. D. Graham, "Comparison of volume and surface mechanisms for magnetic filtration of blood cells, " J. Phys., Colloq. C. 1, vol. 45, pp. C1/779-C1/784, 1984, (Suppl. ).
    • (1984) J. Phys., Colloq. C. 1 , vol.45 , Issue.SUPPL.
    • Graham, M.D.1
  • 24
    • 0016862462 scopus 로고
    • Direct magnetic separation of red cells from whole blood
    • D. Melville, F. Paul, and S. Roath, "Direct magnetic separation of red cells from whole blood, " Nature, vol. 255, p. 706, 1975.
    • (1975) Nature , vol.255 , pp. 706
    • Melville, D.1    Paul, F.2    Roath, S.3
  • 25
    • 0017873457 scopus 로고
    • High gradient magnetic separation of erythrocytes
    • C. S. Owen, "High gradient magnetic separation of erythrocytes, " Biophys. J., vol. 22, pp. 171-178, 1978. (Pubitemid 8324070)
    • (1978) Biophysical Journal , vol.22 , Issue.2 , pp. 171-178
    • Owen, C.S.1
  • 27
    • 0028710162 scopus 로고
    • Specific capture of targeted hematopoietic cells by high gradient magnetic separation by the use of ordered wire array filters and tetrameric antibody complexes linked to a dextran iron particle
    • S. Roath, T. E. Thomas, J. H. Watson, P. M. Lansdorp, R. J. Smith, and A. J. Richards, "Specific capture of targeted hematopoietic cells by high gradient magnetic separation by the use of ordered wire array filters and tetrameric antibody complexes linked to a dextran iron particle, " Progr. Clin. Biol. Res., vol. 389, pp. 155-163, 1994.
    • (1994) Progr. Clin. Biol. Res , vol.389 , pp. 155-163
    • Roath, S.1    Thomas, T.E.2    Watson, J.H.3    Lansdorp, P.M.4    Smith, R.J.5    Richards, A.J.6
  • 28
    • 0034298375 scopus 로고    scopus 로고
    • Separation of red blood cells by magnetic means
    • J. Svoboda, "Separation of red blood cells by magnetic means, " J. Magn. Magn. Mater., vol. 220, pp. L103-L105, 2000.
    • (2000) J. Magn. Magn. Mater , vol.220
    • Svoboda, J.1
  • 29
    • 33747606476 scopus 로고    scopus 로고
    • Continuous magnetic separation of blood components from whole blood
    • M. Takayasu, D. R. Kelland, and J. V. Minervini, "Feasibility of direct magnetic separation of white cells and plasma from whole blood, " IEEE Trans. Appl. Supercond., vol. 10, no. 1, pp. 927-930, Mar. 2000. (Pubitemid 30585094)
    • (2000) IEEE Transactions on Applied Superconductivity , vol.10 , Issue.1 , pp. 927-930
    • Takayasu, M.1    Kelland, D.R.2    Minervini, J.V.3
  • 30
    • 35448954102 scopus 로고    scopus 로고
    • Preliminary 3-D analysis of a high gradient magnetic separator for biomedical applications
    • DOI 10.1016/j.jmmm.2007.06.001, PII S0304885307007494
    • H. Chen, D. Bockenfeld, D. Rempfer, M. D. Kaminski, X. Liu, and A. J. Rosengart, "Preliminary 3-D analysis of a high gradient magnetic separator for biomedical applications, " J. Magn. Magn. Mater., vol. 320, pp. 279-284, 2008. (Pubitemid 47625772)
    • (2008) Journal of Magnetism and Magnetic Materials , vol.320 , Issue.3-4 , pp. 279-284
    • Chen, H.1    Bockenfeld, D.2    Rempfer, D.3    Kaminski, M.D.4    Liu, X.5    Rosengart, A.J.6
  • 31
    • 40149098347 scopus 로고    scopus 로고
    • Analytical model for the magnetophoretic capture of magnetic microspheres in microfluidic devices
    • K. Nandy, S. Chaudhuri, R. Ganguly, and I. K. Puri, "Analytical model for the magnetophoretic capture of magnetic microspheres in microfluidic devices, " J. Magn. Magn. Mater., vol. 320, pp. 1398-1405, 2008.
    • (2008) J. Magn. Magn. Mater , vol.320 , pp. 1398-1405
    • Nandy, K.1    Chaudhuri, S.2    Ganguly, R.3    Puri, I.K.4
  • 32
    • 33645323506 scopus 로고    scopus 로고
    • Microsystems for isolation and electrophysiological analysis of breast cancer cells from blood
    • K. H. Han, A. Han, and A. B. Frazier, "Microsystems for isolation and electrophysiological analysis of breast cancer cells from blood, " Biosens. Bioelectron., vol. 21, pp. 1907-1914, 2006.
    • (2006) Biosens. Bioelectron , vol.21 , pp. 1907-1914
    • Han, K.H.1    Han, A.2    Frazier, A.B.3
  • 33
    • 6944229651 scopus 로고    scopus 로고
    • Enrichment of rare cancer cells through depletion of normal cells using density and flow-through, immunomagnetic cell separation
    • DOI 10.1016/j.exphem.2004.07.007, PII S0301472X04002498
    • O. Lara, X. Tong, M. Zborowski, and J. J. Chalmers, "Enrichment of rare cancer cells through depletion of normal cells using density and flow-through, immunomagnetic cell separation, " Exp. Hematol., vol. 32, pp. 891-904, 2004. (Pubitemid 39410703)
    • (2004) Experimental Hematology , vol.32 , Issue.10 , pp. 891-904
    • Lara, O.1    Tong, X.2    Zborowski, M.3    Chalmers, J.J.4
  • 34
    • 0036488905 scopus 로고    scopus 로고
    • Magnetic field design for selecting and aligning immunomagnetic labeled cells
    • DOI 10.1002/cyto.10060
    • A. G. J. Tibbe, B. G. de Grooth, J. Greve, G. J. Dolan, C. Rao, and L. W. M. M. Terstappen, "Magnetic field design for selecting and aligning immunomagnetic labeled cells, " Cytometry, vol. 47, pp. 163-172, 2002. (Pubitemid 34242029)
    • (2002) Cytometry , vol.47 , Issue.3 , pp. 163-172
    • Tibbe, A.G.J.1    De Grooth, B.G.2    Greve, J.3    Dolan, G.J.4    Rao, C.5    Terstappen, L.W.M.M.6
  • 35
    • 0000801943 scopus 로고
    • The axial drift of the red cells when blood flows in a narrow tube
    • L. E. Bayliss, "The axial drift of the red cells when blood flows in a narrow tube, " J. Physiology, vol. 149, pp. 593-613, 1959.
    • (1959) J. Physiology , vol.149 , pp. 593-613
    • Bayliss, L.E.1
  • 36
    • 34547210645 scopus 로고
    • Radial particle displacements in Poiseuille flow of suspensions
    • G. Segré and A. Silberberg, "Radial particle displacements in Poiseuille flow of suspensions, " Nature, vol. 189, pp. 209-210, 1961.
    • (1961) Nature , vol.189 , pp. 209-210
    • Segré, G.1    Silberberg, A.2
  • 37
    • 84954733866 scopus 로고
    • The lift on a small sphere in a shear flow
    • P. G. Saffman, "The lift on a small sphere in a shear flow, " J. Fluid Mech., vol. 22, p. 385, 1965.
    • (1965) J. Fluid Mech , vol.22 , pp. 385
    • Saffman, P.G.1
  • 38
    • 0037051429 scopus 로고    scopus 로고
    • Slip velocity and lift
    • D. D. Joseph and D. Ocando, "Slip velocity and lift, " J. Fluid Mech., vol. 454, pp. 263-286, 2002.
    • (2002) J. Fluid Mech , vol.454 , pp. 263-286
    • Joseph, D.D.1    Ocando, D.2
  • 39
    • 0030271188 scopus 로고    scopus 로고
    • Biophysical aspects of blood flow in the microvasculature
    • DOI 10.1016/0008-6363(96)00065-X
    • A. R. Pries, T. W. Secomb, and P. Gaehtgens, "Biophysical aspects of blood flow in the microvasculature, " Cardiovas. Res., vol. 32, pp. 654-667, 1996. (Pubitemid 26332305)
    • (1996) Cardiovascular Research , vol.32 , Issue.4 , pp. 654-667
    • Pries, A.R.1    Secomb, T.W.2    Gaehtgens, P.3
  • 40
    • 0000880815 scopus 로고    scopus 로고
    • Lift force and dynamical unbinding of adhering vesicles under shear flow
    • I. Cantat and C. Misbah, "Lift force and dynamical unbinding of adhering vesicles under shear flow, " Phys. Rev. Lett., vol. 83, pp. 880-883, 1999. (Pubitemid 129689681)
    • (1999) Physical Review Letters , vol.83 , Issue.4 , pp. 880-883
    • Cantat, I.1    Misbah, C.2
  • 41
    • 33947700943 scopus 로고    scopus 로고
    • Microfluidic depletion of red blood cells from whole blood in high-aspect-ratio microchannels
    • DOI 10.1007/s10404-006-0104-9
    • R. D. Jäggi, R. Sandoz, and C. S. Effenhauser, "Microfluidic depletion of red blood cells from whole blood in high-aspect-ratio microchannels, " Microfluid. Nanofluid., vol. 3, pp. 47-53, 2007. (Pubitemid 46486897)
    • (2007) Microfluidics and Nanofluidics , vol.3 , Issue.1 , pp. 47-53
    • Jaggi, R.D.1    Sandoz, R.2    Effenhauser, C.S.3
  • 42
    • 51949090453 scopus 로고    scopus 로고
    • Characterization of nonspecific crossover in split-flow thin channel fractionation
    • P. S. Williams, M. Hoyos, P. Kurowski, D. Salhi, L. R. Moore, and M. Zborowski, "Characterization of nonspecific crossover in split-flow thin channel fractionation, " Anal. Chem., vol. 80, pp. 7105-7115, 2008.
    • (2008) Anal. Chem , vol.80 , pp. 7105-7115
    • Williams, P.S.1    Hoyos, M.2    Kurowski, P.3    Salhi, D.4    Moore, L.R.5    Zborowski, M.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.