메뉴 건너뛰기




Volumn 177, Issue , 2013, Pages 710-716

A highly sensitive and selective bulk optode based on dithiacyclooctadecane derivative incorporating chromoionophore v for determination of ultra trace amount of Hg(II)

Author keywords

Bulk optode; Dithiacyclooctadecane derivative; Mercury(II); Spectrophotometry

Indexed keywords

ABSORBANCES; BULK OPTODE; CHROMO-IONOPHORE; COLD VAPOR ATOMIC ABSORPTION SPECTROMETRY; LIMIT OF DETECTION; MERCURY ION; RELATIVE STANDARD DEVIATIONS; SELECTIVE DETERMINATION; TOMATO LEAVES; ULTRA TRACE AMOUNT; ULTRATRACES; WATER SAMPLES;

EID: 84871777704     PISSN: 09254005     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.snb.2012.11.089     Document Type: Article
Times cited : (12)

References (38)
  • 3
    • 0030682094 scopus 로고    scopus 로고
    • Solid phase extraction and determination of ultra trace amounts of mercury(II) using octadecyl silica membrane disks modified by hexathia-18-crown-6-tetraone and cold vapour atomic absorption spectrometry
    • DOI 10.1016/S0003-2670(97)81613-3, PII S0003267097004765
    • Y. Yamini, N. Alizadeh, and M. Shamsipur Solid phase extraction and determination of ultra trace amounts of mercury(II) using octadecyl silica membrane disks modified by hexathia-18-crown-6-tetraone and cold vapour atomic absorption spectrometry Analytica Chimica Acta 355 1997 69 74 (Pubitemid 27528811)
    • (1997) Analytica Chimica Acta , vol.355 , Issue.1 , pp. 69-74
    • Yamini, Y.1    Alizadeh, N.2    Shamsipur, M.3
  • 4
    • 0033038828 scopus 로고    scopus 로고
    • Determination of total mercury in hydrocarbons and natural gas condensate by atomic fluorescence spectrometry
    • DOI 10.1039/a809679a
    • A. Shafawi, L. Eddon, M. Foulkes, P. Stockwell, and W. Corns Determination of total mercury in hydrocarbons and natural gas condensate by atomic fluorescence spectrometry Analyst 124 1999 185 189 (Pubitemid 29092400)
    • (1999) Analyst , vol.124 , Issue.2 , pp. 185-189
    • Shafawi, A.1    Ebdon, L.2    Foulkes, M.3    Stockwell, P.4    Corns, W.5
  • 5
    • 0000128629 scopus 로고    scopus 로고
    • Determination of Trace Mercury in Saltwaters at Screen-Printed Electrodes Modified with Sumichelate Q10R
    • P. Ugo, L. Mortto, P. Bertoncello, and J. Wang Voltammetric determination of mercury(II) in salt waters with sumichelate Q10R Electroanalysis 10 1998 1017 1021 (Pubitemid 128441163)
    • (1998) Electroanalysis , vol.10 , Issue.15 , pp. 1017-1021
    • Ugo, P.1    Moretto, L.M.2    Bertoncello, P.3    Wang, J.4
  • 6
    • 30144442999 scopus 로고    scopus 로고
    • Study of an organically modified clay: Selective adsorption of heavy metal ions and voltammetric determination of mercury(II)
    • N.L. Dias, and F.D.R. do-Carmo Study of an organically modified clay: selective adsorption of heavy metal ions and voltammetric determination of mercury(II) Talanta 68 2006 919 927
    • (2006) Talanta , vol.68 , pp. 919-927
    • Dias, N.L.1    Do-Carmo, F.D.R.2
  • 7
    • 12344308211 scopus 로고    scopus 로고
    • Time-based on-line preconcentration cold vapour generation procedure for ultra-trace mercury determination with inductively coupled plasma atomic emission spectrometry
    • DOI 10.1007/s00216-004-2593-2
    • A.N. Anthemidis, G.A. Zachariadis, C.E. Michos, and J.A. Stratis Time-based on-line preconcentration cold vapour generation procedure for ultra-trace mercury determination with inductively coupled plasma atomic emission spectrometry Analytical and Bioanalytical Chemistry 379 2004 764 769 (Pubitemid 40871492)
    • (2004) Analytical and Bioanalytical Chemistry , vol.379 , Issue.5-6 , pp. 764-769
    • Anthemidis, A.N.1    Zachariadis, G.A.2    Michos, C.E.3    Stratis, J.A.4
  • 8
    • 0000107884 scopus 로고
    • Inductively coupled plasma mass spectrometry with direct injection nebulization for mercury analysis of drinking water
    • M.J. Powell, E.S.K. Quan, W.W. Boomer, and D.R. Wiederin Inductively coupled plasma mass spectrometry with direct injection nebulization for mercury analysis of drinking water Analytical Chemistry 64 1992 2253 2257
    • (1992) Analytical Chemistry , vol.64 , pp. 2253-2257
    • Powell, M.J.1    Quan, E.S.K.2    Boomer, W.W.3    Wiederin, D.R.4
  • 9
    • 0031188897 scopus 로고    scopus 로고
    • Determination of mercury by total-reflection X-ray fluorescence using amalgamation with gold
    • L. Bennun, and J. Gomez Determination of mercury by total-reflection X-ray fluorescence using amalgamation with gold Spectrochimica Acta B 52 1997 1195 1201
    • (1997) Spectrochimica Acta B , vol.52 , pp. 1195-1201
    • Bennun, L.1    Gomez, J.2
  • 10
    • 71749114630 scopus 로고    scopus 로고
    • Highly selective optical-sensing film for lead(II) determination in water samples
    • A.A. Ensafi, A. Katiraei Far, and S. Meghdadi Highly selective optical-sensing film for lead(II) determination in water samples Journal of Hazardous Materials 172 2009 1069 1075
    • (2009) Journal of Hazardous Materials , vol.172 , pp. 1069-1075
    • Ensafi, A.A.1    Katiraei Far, A.2    Meghdadi, S.3
  • 12
    • 0026630286 scopus 로고
    • Theoretical aspects of bulk optode membranes
    • K. Seiler, and W. Simon Theoretical aspects of bulk optode membranes Analytica Chimica Acta 266 1992 73 87
    • (1992) Analytica Chimica Acta , vol.266 , pp. 73-87
    • Seiler, K.1    Simon, W.2
  • 13
    • 0001342171 scopus 로고
    • Selectivity of ion-sensitive bulk optodes
    • E. Bakker, and W. Simon Selectivity of ion-sensitive bulk optodes Analytical Chemistry 64 1992 1805 1812
    • (1992) Analytical Chemistry , vol.64 , pp. 1805-1812
    • Bakker, E.1    Simon, W.2
  • 14
    • 0001249646 scopus 로고
    • Lead-selective bulk optodes based on neutral ionophores with subnanomolar detection limits
    • M. Lerchi, E. Bakker, B. Rusterholz, and W. Simon Lead-selective bulk optodes based on neutral ionophores with subnanomolar detection limits Analytical Chemistry 64 1992 1534 1540
    • (1992) Analytical Chemistry , vol.64 , pp. 1534-1540
    • Lerchi, M.1    Bakker, E.2    Rusterholz, B.3    Simon, W.4
  • 15
    • 0034213125 scopus 로고    scopus 로고
    • Development of a new bulk optode membrane for the determination of mercury(II)
    • DOI 10.1016/S0003-2670(00)00809-6, PII S0003267000008096
    • C. Sanchez-Pedreno, J.A. Ortuno, M.I. Albero, M.S. Garcia, and M.V. Valero Development of a new bulk optode membrane for the determination of mercury(II) Analytica Chimica Acta 414 2000 195 203 (Pubitemid 30251908)
    • (2000) Analytica Chimica Acta , vol.414 , Issue.1-2 , pp. 195-203
    • Sanchez-Pedreno, C.1    Ortuno, J.A.2    Albero, M.I.3    Garcia, M.S.4    Valero, M.V.5
  • 16
    • 33845977776 scopus 로고    scopus 로고
    • A PVC-membrane bulk optode for gallium(III) ion determination
    • DOI 10.1016/j.talanta.2006.04.029, PII S0039914006002670
    • A. Safavi, and M. Sadeghi A PVC-membrane bulk optode for gallium(III) ion determination Talanta 71 2007 339 343 (Pubitemid 46043491)
    • (2007) Talanta , vol.71 , Issue.1 , pp. 339-343
    • Safavi, A.1    Sadeghi, M.2
  • 17
    • 29244432162 scopus 로고    scopus 로고
    • Development of a mercury optical sensor based on immobilization of 4-(2-pyridylazo)-resorcinol on a triacetylcellulose membrane
    • DOI 10.1016/j.snb.2005.02.027, PII S0925400505002145
    • A.A. Ensafi, and M. Fooladgar Development of a mercury optical sensor based on immobilization of 4-(2-pyridylazo)-resorcinol on a triacetylcellulose membrane Sensors and Actuators B 113 2006 88 93 (Pubitemid 41831273)
    • (2006) Sensors and Actuators, B: Chemical , vol.113 , Issue.1 , pp. 88-93
    • Ensafi, A.A.1    Fouladgar, M.2
  • 18
    • 77956443333 scopus 로고    scopus 로고
    • A sensitive and selective fluorescent sensor for the determination of mercury(II) based on a novel triazine-thione derivative
    • N. Aksuner, B. Basaran, E. Henden, I. Yilmaz, and A. Cukurovali A sensitive and selective fluorescent sensor for the determination of mercury(II) based on a novel triazine-thione derivative Dyes and Pigments 88 2011 143 148
    • (2011) Dyes and Pigments , vol.88 , pp. 143-148
    • Aksuner, N.1    Basaran, B.2    Henden, E.3    Yilmaz, I.4    Cukurovali, A.5
  • 19
    • 71649099743 scopus 로고    scopus 로고
    • A sensitive and selective bulk optode for determination of Hg(II) based on hexathiacyclooctadecane and chromoionophore v
    • A.A. Ensafi, and M. Fouladgar A sensitive and selective bulk optode for determination of Hg(II) based on hexathiacyclooctadecane and chromoionophore V Sensors and Actuators B 136 2009 326 331
    • (2009) Sensors and Actuators B , vol.136 , pp. 326-331
    • Ensafi, A.A.1    Fouladgar, M.2
  • 20
    • 77955322704 scopus 로고    scopus 로고
    • Optical sensor based on 1,3-di(2-methoxyphenyl)triazene for monitoring trace amounts of mercury(II) in water samples
    • M.B. Gholivand, M. Mohammadi, and M. Kazem Rofouei Optical sensor based on 1,3-di(2-methoxyphenyl)triazene for monitoring trace amounts of mercury(II) in water samples Materials Science and Engineering C 30 2010 847 852
    • (2010) Materials Science and Engineering C , vol.30 , pp. 847-852
    • Gholivand, M.B.1    Mohammadi, M.2    Kazem Rofouei, M.3
  • 22
    • 64549150521 scopus 로고    scopus 로고
    • Highly selective sensing of mercury (II) by development and characterization of a PVC-based optical sensor
    • A. Yari, and F. Papi Highly selective sensing of mercury (II) by development and characterization of a PVC-based optical sensor Sensors and Actuators B 138 2009 467 473
    • (2009) Sensors and Actuators B , vol.138 , pp. 467-473
    • Yari, A.1    Papi, F.2
  • 23
    • 84856911553 scopus 로고    scopus 로고
    • A highly selective optode for determination of Hg (II) by a modified immobilization of indigo carmine on a triacetylcellulose membrane
    • H. Tavallali, E. Shaabanpur, and P. Vahdati A highly selective optode for determination of Hg (II) by a modified immobilization of indigo carmine on a triacetylcellulose membrane Spectrochimica Acta A 89 2012 216 221
    • (2012) Spectrochimica Acta A , vol.89 , pp. 216-221
    • Tavallali, H.1    Shaabanpur, E.2    Vahdati, P.3
  • 24
    • 2342630452 scopus 로고    scopus 로고
    • Design and characteristics of a mercury (II) optode based on immobilization of dithizone on a triacetylcellulose membrane
    • A. Safavi, and M. Bagheri Design and characteristics of a mercury (II) optode based on immobilization of dithizone on a triacetylcellulose membrane Sensors and Actuators B 99 2004 608 612
    • (2004) Sensors and Actuators B , vol.99 , pp. 608-612
    • Safavi, A.1    Bagheri, M.2
  • 25
    • 81155152244 scopus 로고    scopus 로고
    • Ultra trace mercury(II) detection by a highly selective new optical sensor
    • A. Yari, and F. Papi Ultra trace mercury(II) detection by a highly selective new optical sensor Sensors and Actuators B 160 2011 698 704
    • (2011) Sensors and Actuators B , vol.160 , pp. 698-704
    • Yari, A.1    Papi, F.2
  • 26
    • 46449095435 scopus 로고    scopus 로고
    • Highly selective optical sensor for mercury assay based on covalent immobilization of 4-hydroxy salophen on a triacetylcellulose membrane
    • Ali A. Ensafi, A. Katiraei Far, and S. Meghdadi Highly selective optical sensor for mercury assay based on covalent immobilization of 4-hydroxy salophen on a triacetylcellulose membrane Sensors and Actuators B 133 2008 84 90
    • (2008) Sensors and Actuators B , vol.133 , pp. 84-90
    • Ensafi, A.A.1    Katiraei Far, A.2    Meghdadi, S.3
  • 27
    • 38749093384 scopus 로고    scopus 로고
    • Highly selective potentiometrie membrane sensor for Hg(II) based on bis(benzoyl acetone) diethylene triamine
    • DOI 10.1109/JSEN.2007.913146
    • A.A. Ensafi, S. Meghdadi, and A.R. Allafchian Highly selective potentiometric membrane sensor for Hg(II) based on bis(benzoyl acetone) diethylene triamine IEEE Sensors Journal 8 2008 248 254 (Pubitemid 351185400)
    • (2008) IEEE Sensors Journal , vol.8 , Issue.3 , pp. 248-254
    • Ensafi, A.A.1    Meghdadi, S.2    Allafchian, A.R.3
  • 28
    • 79751536464 scopus 로고    scopus 로고
    • A new Schiff's base ligand immobilized agarose membrane optical sensor for selective monitoring of mercury ion
    • K. Alizadeh, R. Parooi, P. Hashemi, B. Rezaei, and M.R. Ganjali A new Schiff's base ligand immobilized agarose membrane optical sensor for selective monitoring of mercury ion Journal of Hazardous Materials 186 2011 1794 1800
    • (2011) Journal of Hazardous Materials , vol.186 , pp. 1794-1800
    • Alizadeh, K.1    Parooi, R.2    Hashemi, P.3    Rezaei, B.4    Ganjali, M.R.5
  • 29
    • 34247558638 scopus 로고    scopus 로고
    • Development of a disposable mercury ion-selective optode based on trityl-picolinamide as ionophore
    • DOI 10.1016/j.aca.2007.03.064, PII S0003267007006551
    • B. Kuswandi, Nuriman, H.H. Dam, D.N. Reinhoudt, and W. Verboom Development of a disposable mercury ion-selective optode based on trityl-picolinamide as ionophore Analytica Chimica Acta 591 2007 208 213 (Pubitemid 46671540)
    • (2007) Analytica Chimica Acta , vol.591 , Issue.2 , pp. 208-213
    • Kuswandi, B.1    Nuriman2    Dam, H.H.3    Reinhoudt, D.N.4    Verboom, W.5
  • 30
    • 60249095920 scopus 로고    scopus 로고
    • An optical sensor for mercury ion based on the fluorescence quenching of tetra(p-dimethylaminophenyl)porphyrin
    • Y. Yang, J. Jiang, G. Shen, and R. Yu An optical sensor for mercury ion based on the fluorescence quenching of tetra(p-dimethylaminophenyl)porphyrin Analytica Chimica Acta 636 2009 83 88
    • (2009) Analytica Chimica Acta , vol.636 , pp. 83-88
    • Yang, Y.1    Jiang, J.2    Shen, G.3    Yu, R.4
  • 31
    • 42949099311 scopus 로고    scopus 로고
    • Development of a highly sensitive and selective optical chemical sensor for batch and flow-through determination of mercury ion
    • DOI 10.1016/j.snb.2007.12.008, PII S0925400507010064
    • M.K. Amini, B. Khezri, and A.R. Firooz Development of a highly sensitive and selective optical chemical sensor for batch and flow-through determination of mercury ion Sensors and Actuators B 131 2008 470 478 (Pubitemid 351609349)
    • (2008) Sensors and Actuators, B: Chemical , vol.131 , Issue.2 , pp. 470-478
    • Amini, M.K.1    Khezri, B.2    Firooz, A.R.3
  • 32
    • 41149109979 scopus 로고    scopus 로고
    • An optical chemical sensor for mercury ion based on 2-mercaptopyrimidine in PVC membrane
    • B. Khezri, M.K. Amini, and A.R. Firooz An optical chemical sensor for mercury ion based on 2-mercaptopyrimidine in PVC membrane Analytical and Bioanalytical Chemistry 390 2008 1943 1950
    • (2008) Analytical and Bioanalytical Chemistry , vol.390 , pp. 1943-1950
    • Khezri, B.1    Amini, M.K.2    Firooz, A.R.3
  • 33
    • 84864289248 scopus 로고    scopus 로고
    • Selective and sensitive optical chemical sensor for the determination of Hg(II) ions based on tetrathia-12-crown-4 and chromoionophore i
    • A.R. Firooz, M. Movahedi, and A.A. Ensafi Selective and sensitive optical chemical sensor for the determination of Hg(II) ions based on tetrathia-12-crown-4 and chromoionophore I Sensors and Actuators B 171-172 2012 492 498
    • (2012) Sensors and Actuators B , vol.171-172 , pp. 492-498
    • Firooz, A.R.1    Movahedi, M.2    Ensafi, A.A.3
  • 35
    • 1642307572 scopus 로고    scopus 로고
    • Efficient synthesis of new sulfur macrocyclic diamides
    • H. Sharghi, and Z. Paziraee Efficient synthesis of new sulfur macrocyclic diamides Synthesis 4 2004 600 604 (Pubitemid 38393352)
    • (2004) Synthesis , Issue.4 , pp. 600-604
    • Sharghi, H.1    Paziraee, Z.2
  • 36
    • 0028905316 scopus 로고
    • Fluorimetric determination of mercury with a water-soluble porphyrin and porphyrin-doped sol-gel films
    • M. Plaschke, R. Czolk, and H.J. Ache Fluorimetric determination of mercury with a water-soluble porphyrin and porphyrin-doped sol-gel films Analytica Chimica Acta 304 1995 107 113
    • (1995) Analytica Chimica Acta , vol.304 , pp. 107-113
    • Plaschke, M.1    Czolk, R.2    Ache, H.J.3
  • 37
    • 4544366331 scopus 로고    scopus 로고
    • Carrier-based ion-selective electrodes and bulk optodes. 1. General characteristics
    • E. Bakker, P. Buhlmann, and E. Pretsch Carrier-based ion-selective electrodes and bulk optodes. 1. General characteristics Chemical Reviews 97 1997 3083 3132 (Pubitemid 127667408)
    • (1997) Chemical Reviews , vol.97 , Issue.8 , pp. 3083-3132
    • Bakker, E.1    Buhlmann, P.2    Pretsch, E.3
  • 38
    • 0032145855 scopus 로고    scopus 로고
    • Cesium-selective optode membrane based on the lipophilic calix[4]biscrown in the 1,3-alternate conformation
    • DOI 10.1016/S0039-9140(98)00023-X, PII S003991409800023X
    • H. Zeng, and B. Dureault Cesium-selective optode membrane based on the lipophilic calix[4]biscrown in the 13-alternate conformation Talanta 46 1998 1485 1491 (Pubitemid 28335830)
    • (1998) Talanta , vol.46 , Issue.6 , pp. 1485-1491
    • Zeng, H.1    Dureault, B.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.