1
-
-
38849108040
-
Design and evaluation of a HDR skin applicator with flattening filter
-
Granero D., Pérez-Calatayud J., Jimeno J., Ballester F., Casal E., Crispín V., et al. Design and evaluation of a HDR skin applicator with flattening filter. Med Phys 2008, 35:495-503.
-
(2008)
Med Phys
, vol.35
, pp. 495-503
-
-
Granero, D.1
Pérez-Calatayud, J.2
Jimeno, J.3
Ballester, F.4
Casal, E.5
Crispín, V.6
-
2
-
-
18944373369
-
A dosimetric study of the Leipzig applicators
-
Pérez-Calatayud J., Granero D., Ballester F., Puchades V., Casal E., Soriano A., et al. A dosimetric study of the Leipzig applicators. Int J Rad Oncol Biol Phys 2005, 62:579-584.
-
(2005)
Int J Rad Oncol Biol Phys
, vol.62
, pp. 579-584
-
-
Pérez-Calatayud, J.1
Granero, D.2
Ballester, F.3
Puchades, V.4
Casal, E.5
Soriano, A.6
-
3
-
-
11244289512
-
Dosimetric characteristics of the Leipzig surface applicators used in the high dose rate brachy radiotherapy
-
Niu H., His W.C., Chu J.C.H., Kirk MC. Dosimetric characteristics of the Leipzig surface applicators used in the high dose rate brachy radiotherapy. Med Phys 2004, 31:3372-3377.
-
(2004)
Med Phys
, vol.31
, pp. 3372-3377
-
-
Niu, H.1
His, W.C.2
Chu, J.C.H.3
Kirk, M.C.4
-
4
-
-
0041701638
-
Alternative effective modality of Leipzig applicator with an electron beam for the treatment of superficial malignancies
-
Hwang I.M., Lin S.Y., Lin L.C., Chuang K.S., Ding H.J. Alternative effective modality of Leipzig applicator with an electron beam for the treatment of superficial malignancies. Nuc Inst Meth A 2003, 508:460-466.
-
(2003)
Nuc Inst Meth A
, vol.508
, pp. 460-466
-
-
Hwang, I.M.1
Lin, S.Y.2
Lin, L.C.3
Chuang, K.S.4
Ding, H.J.5
-
5
-
-
0030928967
-
Surface applicators for high dose rate brachytherapy in aids-related Kaposís sarcoma
-
Evans M.D.C., Yassa M., Podgorsak E.B., Roman T.N., Schreiner L.J., Souhami L. Surface applicators for high dose rate brachytherapy in aids-related Kaposís sarcoma. Int J Radiat Oncol Biol Phys 1997, 39:769-774.
-
(1997)
Int J Radiat Oncol Biol Phys
, vol.39
, pp. 769-774
-
-
Evans, M.D.C.1
Yassa, M.2
Podgorsak, E.B.3
Roman, T.N.4
Schreiner, L.J.5
Souhami, L.6
-
6
-
-
22544440841
-
Precise radiochromic film dosimetry using a flat bed document scanner
-
Devic S., Seuntjens J., Sham E., Podgorsak E.B., Schmidtlein C.R., Kirov A.S., Soares C.G. Precise radiochromic film dosimetry using a flat bed document scanner. Med Phys 2005, 32:2245-2253.
-
(2005)
Med Phys
, vol.32
, pp. 2245-2253
-
-
Devic, S.1
Seuntjens, J.2
Sham, E.3
Podgorsak, E.B.4
Schmidtlein, C.R.5
Kirov, A.S.6
Soares, C.G.7
-
7
-
-
0038377458
-
GEANT4 - A simulation Toolkit
-
See also, last accessed 14 November 2011
-
Agostinelli S., Allison J., Amako K., Apostolakis J., Araujo H., Arce P., et al. GEANT4 - A simulation Toolkit. Nuc Ins Meth A 2003, 506:250-303. See also, last accessed 14 November 2011. http://geant4.web.cern.ch/geant4.
-
(2003)
Nuc Ins Meth A
, vol.506
, pp. 250-303
-
-
Agostinelli, S.1
Allison, J.2
Amako, K.3
Apostolakis, J.4
Araujo, H.5
Arce, P.6
-
8
-
-
0023514509
-
Monte Carlo evaluation of kerma at a point for photon transport problems
-
Williamson J.F. Monte Carlo evaluation of kerma at a point for photon transport problems. Med Phys 1987, 14:567-576.
-
(1987)
Med Phys
, vol.14
, pp. 567-576
-
-
Williamson, J.F.1
|