Volumn 124, Issue 4, 2012, Pages 250-255

Accuracy of noninvasive and invasive point-of-care total blood hemoglobin measurement in an outpatient setting

Author keywords

Anemia; Hemoglobin; Monitoring; Outpatients; Physiologic; Point of care technology; Pulse oximetry

Indexed keywords

HEMOGLOBIN;

EID: 84871708732     PISSN: 00325481     EISSN: 19419260     Source Type: Journal    
DOI: 10.3810/pgm.2012.07.2584     Document Type: Article
Times cited : (42)

References (16)
  • 1
    • 79953174576 scopus 로고    scopus 로고
    • A comparison of three methods of hemoglobin monitoring in patients undergoing spine surgery
    • Miller RD, Ward TA, Shiboski SC, Cohen NH. A comparison of three methods of hemoglobin monitoring in patients undergoing spine surgery. Anesth Analg. 2011;112(4):858-863.
    • (2011) Anesth Analg , vol.112 , Issue.4 , pp. 858-863
    • Miller, R.D.1    Ward, T.A.2    Shiboski, S.C.3    Cohen, N.H.4
  • 2
    • 79955688079 scopus 로고    scopus 로고
    • Validation of noninvasive hemoglobin measurements using the Masimo Radical-7 SpHb Station
    • Causey MW, Miller S, Foster A, Beekley A, Zenger D, Martin M. Validation of noninvasive hemoglobin measurements using the Masimo Radical-7 SpHb Station. Am J Surg. 2011;201(5): 590-596.
    • (2011) Am J Surg , vol.201 , Issue.5 , pp. 590-596
    • Causey, M.W.1    Miller, S.2    Foster, A.3    Beekley, A.4    Zenger, D.5    Martin, M.6
  • 3
    • 82255179454 scopus 로고    scopus 로고
    • Continuous noninvasive hemoglobin monitoring during complex spine surgery
    • Berkow L, Rotolo S, Mirski E. Continuous noninvasive hemoglobin monitoring during complex spine surgery. Anesth Analg. 2011;113(6):1396-1402.
    • (2011) Anesth Analg , vol.113 , Issue.6 , pp. 1396-1402
    • Berkow, L.1    Rotolo, S.2    Mirski, E.3
  • 4
    • 80052968149 scopus 로고    scopus 로고
    • Accuracy of a continuous noninvasive hemoglobin monitor in intensive care unit patients
    • Frasca D, Dahyot-Fizelier C, Catherine K, Levrat Q, Debaene B, Mimoz O. Accuracy of a continuous noninvasive hemoglobin monitor in intensive care unit patients. Crit Care Med. 2011;39(10): 2277-2282.
    • (2011) Crit Care Med , vol.39 , Issue.10 , pp. 2277-2282
    • Frasca, D.1    Dahyot-Fizelier, C.2    Catherine, K.3    Levrat, Q.4    Debaene, B.5    Mimoz, O.6
  • 6
    • 80051948894 scopus 로고    scopus 로고
    • Clinical and Laboratory Standards Institute, Approved guidelines, fourth edition. Wayne, PA: Clinical and Laboratory Standards Institute. Document number H18-A4
    • Clinical and Laboratory Standards Institute. Procedures for the handling and processing of blood specimens for common laboratory tests. Approved guidelines, fourth edition. Wayne, PA: Clinical and Laboratory Standards Institute. Document number H18-A4. 2010.
    • (2010) Procedures For the Handling and Processing of Blood Specimens For Common Laboratory Tests
  • 7
    • 0023146804 scopus 로고
    • International Committee for Standardization in Haematology; Expert Panel on Haemoglobinometry
    • Recommendations for reference method for haemoglobinometry in human blood (ICSH standard 1986) and specifications for international haemiglobincyanide reference preparation (3rd edition)
    • Recommendations for reference method for haemoglobinometry in human blood (ICSH standard 1986) and specifications for international haemiglobincyanide reference preparation (3rd edition). International Committee for Standardization in Haematology; Expert Panel on Haemoglobinometry. Clin Lab Haematol. 1987;9(1):73-79.
    • (1987) Clin Lab Haematol , vol.9 , Issue.1 , pp. 73-79
  • 8
    • 84876573570 scopus 로고    scopus 로고
    • Update in anesthesia, Accessed August 25
    • Ickeringill M. The HemoCue B-haemoglobin analyser. Update in anesthesia. http://www.nda.ox.ac.uk/wfsa/html/u13/u1305_01.htm#tpf. Accessed August 25, 2011.
    • (2011) The HemoCue B-haemoglobin Analyser
    • Ickeringill, M.1
  • 9
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet. 1986;1(8476): 307-310.
    • (1986) Lancet , vol.1 , Issue.8476 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2
  • 10
    • 80055096355 scopus 로고    scopus 로고
    • The accuracy of noninvasive hemoglobin measurement by multiwavelength pulse oximetry after cardiac surgery
    • Nguyen BV, Vincent JL, Nowak E, et al. The accuracy of noninvasive hemoglobin measurement by multiwavelength pulse oximetry after cardiac surgery. Anesth Analg. 2011;113(5):1052-1057.
    • (2011) Anesth Analg , vol.113 , Issue.5 , pp. 1052-1057
    • Nguyen, B.V.1    Vincent, J.L.2    Nowak, E.3
  • 11
    • 79953178906 scopus 로고    scopus 로고
    • Performance evaluation of a noninvasive hemoglobin monitoring device
    • Gayat E, Bodin A, Sportiello C, et al. Performance evaluation of a noninvasive hemoglobin monitoring device. Ann Emerg Med. 2011;57(4):330-333.
    • (2011) Ann Emerg Med , vol.57 , Issue.4 , pp. 330-333
    • Gayat, E.1    Bodin, A.2    Sportiello, C.3
  • 12
    • 79959399044 scopus 로고    scopus 로고
    • Response to Gayat, et al
    • O'Reilly M. Response to Gayat, et al. Ann Emerg Med. 2011;58(1):106-107.
    • (2011) Ann Emerg Med , vol.58 , Issue.1 , pp. 106-107
    • O'Reilly, M.1
  • 13
    • 84855465225 scopus 로고    scopus 로고
    • Non-invasive measurement of hemoglobin: Assessment of two different point-of-care technologies
    • Gayat E, Aulagnier J, Matthieu E, Boisson M, Fischler M. Non-invasive measurement of hemoglobin: assessment of two different point-of-care technologies. PLoS One. 2012;7(1):e30065.
    • (2012) PLoS One , vol.7 , Issue.1
    • Gayat, E.1    Aulagnier, J.2    Matthieu, E.3    Boisson, M.4    Fischler, M.5
  • 14
    • 80052177803 scopus 로고    scopus 로고
    • Comparison of the accuracy of noninvasive hemoglobin monitoring by spectrophotometry (SpHb) and HemoCue(R) with automated laboratory hemoglobin measurement
    • Lamhaut L, Apriotesei R, Combes X, Lejay M, Carli P, Vivien B. Comparison of the accuracy of noninvasive hemoglobin monitoring by spectrophotometry (SpHb) and HemoCue(R) with automated laboratory hemoglobin measurement. Anesthesiology. 2011;115(3):548-554.
    • (2011) Anesthesiology , vol.115 , Issue.3 , pp. 548-554
    • Lamhaut, L.1    Apriotesei, R.2    Combes, X.3    Lejay, M.4    Carli, P.5    Vivien, B.6
  • 15


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.