메뉴 건너뛰기




Volumn 27, Issue 3, 2012, Pages 513-522

Load-dependent heat development, thermal effects, duration, and soft tissue preservation in piezosurgical implant site preparation: An experimental ex vivo study

Author keywords

Dental implant; Implant site preparation; Piezosurgery; Sinus floor elevation; Thermal tissue alteration; Time duration

Indexed keywords

ANIMAL; ARTICLE; BODY TEMPERATURE; BONE; DENTAL PROCEDURE; HEAT; INJURY; MAXILLARY SINUS; NOSE MUCOSA; OPERATION DURATION; ORAL SURGERY; PIEZOSURGERY; SKULL; SWINE; TIME; TOOTH IMPLANT;

EID: 84871679486     PISSN: 08822786     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (13)

References (50)
  • 1
    • 0022069236 scopus 로고
    • Thermally induced bone necrosis in rabbits: Relation to implant failure in humans
    • Albrektsson T, Eriksson A. Thermally induced bone necrosis in rabbits: Relation to implant failure in humans. Clin Orthop Relat Res 1985;195: 311-312.
    • (1985) Clin Orthop Relat Res , vol.195 , pp. 311-312
    • Albrektsson, T.1    Eriksson, A.2
  • 2
    • 0031217840 scopus 로고    scopus 로고
    • Effects of drill speed on heat production and the rate and quality of bone formation in dental implant osteotomies. Part I: Relationship between drill speed and heat production
    • Iyer S, Weiss C, Mehta A. Effects of drill speed on heat production and the rate and quality of bone formation in dental implant osteotomies. Part I: Relationship between drill speed and heat production. Int J Prosthodont 1997;10: 411-414.
    • (1997) Int J Prosthodont , vol.10 , pp. 411-414
    • Iyer, S.1    Weiss, C.2    Mehta, A.3
  • 3
    • 0031264521 scopus 로고    scopus 로고
    • Effects of drill speed on heat production and the rate and quality of bone formation in dental implant osteotomies. Part II: Relationship between drill speed and healing
    • Iyer S, Weiss C, Mehta A. Effects of drill speed on heat production and the rate and quality of bone formation in dental implant osteotomies. Part II: Relationship between drill speed and healing. Int J Prosthodont 1997;10: 536-540.
    • (1997) Int J Prosthodont , vol.10 , pp. 536-540
    • Iyer, S.1    Weiss, C.2    Mehta, A.3
  • 4
    • 3042787506 scopus 로고    scopus 로고
    • Effects of sealing the perforated sinus membrane with a resorbable collagen membrane: A pilot study in humans
    • Proussaefs P, Lozada J, Kim J. Effects of sealing the perforated sinus membrane with a resorbable collagen membrane: A pilot study in humans. J Oral Implantol 2003;29: 235-241.
    • (2003) J Oral Implantol , vol.29 , pp. 235-241
    • Proussaefs, P.1    Lozada, J.2    Kim, J.3
  • 5
    • 0344466474 scopus 로고    scopus 로고
    • A simplified classification and repair system for sinus membrane perforations
    • Fugazzotto PA, Vlassis J. A simplified classification and repair system for sinus membrane perforations. J Periodontol 2003;74: 1534-1541.
    • (2003) J Periodontol , vol.74 , pp. 1534-1541
    • Fugazzotto, P.A.1    Vlassis, J.2
  • 7
    • 43449110744 scopus 로고    scopus 로고
    • Micromorphometrical analysis of conventional osteotomy techniques and ultrasonic osteotomy at the rabbit skull
    • Maurer P, Kriwalsky MS, Block Veras R, Vogel J, Syrowatka F, Heiss C. Micromorphometrical analysis of conventional osteotomy techniques and ultrasonic osteotomy at the rabbit skull. Clin Oral Implants Res 2008;19: 570-575.
    • (2008) Clin Oral Implants Res , vol.19 , pp. 570-575
    • Maurer, P.1    Kriwalsky, M.S.2    Block Veras, R.3    Vogel, J.4    Syrowatka, F.5    Heiss, C.6
  • 8
    • 34948872517 scopus 로고    scopus 로고
    • Light microscopic examination of rabbit skulls following conventional and Piezosurgery osteotomy
    • Maurer P, Kriwalsky MS, Block Veras R, Brandt J, Heiss C. Light microscopic examination of rabbit skulls following conventional and Piezosurgery osteotomy. Biomed Tech (Berl) 2007;52: 351-355.
    • (2007) Biomed Tech (Berl) , vol.52 , pp. 351-355
    • Maurer, P.1    Kriwalsky, M.S.2    Block Veras, R.3    Brandt, J.4    Heiss, C.5
  • 11
    • 0035751049 scopus 로고    scopus 로고
    • The piezoelectric bony window osteotomy and sinus membrane elevation: Introduction of a new technique for simplification of the sinus augmentation procedure
    • Vercellotti T, De Paoli S, Nevins M. The piezoelectric bony window osteotomy and sinus membrane elevation: Introduction of a new technique for simplification of the sinus augmentation procedure. Int J Periodontics Restorative Dent 2001;21: 561-567.
    • (2001) Int J Periodontics Restorative Dent , vol.21 , pp. 561-567
    • Vercellotti, T.1    De Paoli, S.2    Nevins, M.3
  • 12
    • 35348948034 scopus 로고    scopus 로고
    • Schneiderian membrane perforation rate during sinus elevation using piezosurgery: Clinical results of 100 consecutive cases
    • Wallace SS, Mazor Z, Froum SJ, Cho SC, Tarnow DP. Schneiderian membrane perforation rate during sinus elevation using piezosurgery: Clinical results of 100 consecutive cases. Int J Periodontics Restorative Dent 2007;27: 413-419.
    • (2007) Int J Periodontics Restorative Dent , vol.27 , pp. 413-419
    • Wallace, S.S.1    Mazor, Z.2    Froum, S.J.3    Cho, S.C.4    Tarnow, D.P.5
  • 13
    • 42149085649 scopus 로고    scopus 로고
    • Osteotomy and membrane elevation during the maxillary sinus augmentation procedure. A comparative study: Piezoelectric device vs. conventional rotative instruments
    • Barone A, Santini S, Marconcini S, Giacomelli L, Gherlone E, Covani U. Osteotomy and membrane elevation during the maxillary sinus augmentation procedure. A comparative study: Piezoelectric device vs. conventional rotative instruments. Clin Oral Implants Res 2008;19: 511-515.
    • (2008) Clin Oral Implants Res , vol.19 , pp. 511-515
    • Barone, A.1    Santini, S.2    Marconcini, S.3    Giacomelli, L.4    Gherlone, E.5    Covani, U.6
  • 14
    • 0032601842 scopus 로고    scopus 로고
    • Factors affecting heat generation during implant site preparation: A review of biologic observations and future considerations
    • Tehemar SH. Factors affecting heat generation during implant site preparation: A review of biologic observations and future considerations. Int J Oral Maxillofac Implants 1999;14: 127-136.
    • (1999) Int J Oral Maxillofac Implants , vol.14 , pp. 127-136
    • Tehemar, S.H.1
  • 15
    • 34247893755 scopus 로고    scopus 로고
    • Cytokines and growth factors involved in the osseointegration of oral titanium implants positioned using piezoelectric bone surgery versus a drill technique: A pilot study in minipigs
    • Preti G, Martinasso G, Peirone B, et al. Cytokines and growth factors involved in the osseointegration of oral titanium implants positioned using piezoelectric bone surgery versus a drill technique: A pilot study in minipigs. J Periodontol 2007;78: 716-722.
    • (2007) J Periodontol , vol.78 , pp. 716-722
    • Preti, G.1    Martinasso, G.2    Peirone, B.3
  • 16
    • 79952279004 scopus 로고    scopus 로고
    • Comparison of Er: YAG laser and piezoelectric osteotomy: An animal study in sheep
    • Stubinger S, Nuss K, Pongratz M, et al. Comparison of Er: YAG laser and piezoelectric osteotomy: An animal study in sheep. Lasers Surg Med 2010;42: 743-751.
    • (2010) Lasers Surg Med , vol.42 , pp. 743-751
    • Stubinger, S.1    Nuss, K.2    Pongratz, M.3
  • 17
    • 77956666910 scopus 로고    scopus 로고
    • Comparison of Er: YAG laser, piezoelectric, and drill osteotomy for dental implant site preparation: A biomechanical and histological analysis in sheep
    • Stubinger S, Biermeier K, Bachi B, Ferguson SJ, Sader R, von Rechenberg B. Comparison of Er: YAG laser, piezoelectric, and drill osteotomy for dental implant site preparation: A biomechanical and histological analysis in sheep. Lasers Surg Med 2010;42: 652-661.
    • (2010) Lasers Surg Med , vol.42 , pp. 652-661
    • Stubinger, S.1    Biermeier, K.2    Bachi, B.3    Ferguson, S.J.4    Sader, R.5    von Rechenberg, B.6
  • 18
    • 38449087448 scopus 로고    scopus 로고
    • Ultrasound bone cutting for surgically assisted rapid maxillary expansion under local anesthesia. Preliminary results
    • Robiony M, Polini F, Costa F, Zerman N, Politi M. Ultrasound bone cutting for surgically assisted rapid maxillary expansion under local anesthesia. Preliminary results. Minerva Stomatol 2007;56: 359-368.
    • (2007) Minerva Stomatol , vol.56 , pp. 359-368
    • Robiony, M.1    Polini, F.2    Costa, F.3    Zerman, N.4    Politi, M.5
  • 21
    • 0004998823 scopus 로고
    • A study of the effects of high-speed rotary instruments on bone repair in dogs
    • Costich ER, Youngblood PJ, Walden JM. A study of the effects of high-speed rotary instruments on bone repair in dogs. Oral Surg Oral Med Oral Pathol 1964;17: 563-571.
    • (1964) Oral Surg Oral Med Oral Pathol , vol.17 , pp. 563-571
    • Costich, E.R.1    Youngblood, P.J.2    Walden, J.M.3
  • 22
    • 0020322562 scopus 로고
    • Thermal injury to bone. A vital-microscopic description of heat effects
    • Eriksson A, Albrektsson T, Grane B, McQueen D. Thermal injury to bone. A vital-microscopic description of heat effects. Int J Oral Surg 1982;11: 115-121.
    • (1982) Int J Oral Surg , vol.11 , pp. 115-121
    • Eriksson, A.1    Albrektsson, T.2    Grane, B.3    McQueen, D.4
  • 23
    • 0020790218 scopus 로고
    • Temperature threshold levels for heatinduced bone tissue injury: A vital-microscopic study in the rabbit
    • Eriksson AR, Albrektsson T. Temperature threshold levels for heatinduced bone tissue injury: A vital-microscopic study in the rabbit. J Prosthet Dent 1983;50: 101-107.
    • (1983) J Prosthet Dent , vol.50 , pp. 101-107
    • Eriksson, A.R.1    Albrektsson, T.2
  • 24
    • 0021685213 scopus 로고
    • The effect of heat on bone regeneration: An experimental study in the rabbit using the bone growth chamber
    • Eriksson RA, Albrektsson T. The effect of heat on bone regeneration: An experimental study in the rabbit using the bone growth chamber. J Oral Maxillofac Surg 1984;42: 705-711.
    • (1984) J Oral Maxillofac Surg , vol.42 , pp. 705-711
    • Eriksson, R.A.1    Albrektsson, T.2
  • 25
    • 0019033815 scopus 로고
    • Effect of internal irrigation on frictional heat generated from bone drilling
    • Lavelle C, Wedgwood D. Effect of internal irrigation on frictional heat generated from bone drilling. J Oral Surg 1980;38: 499-503.
    • (1980) J Oral Surg , vol.38 , pp. 499-503
    • Lavelle, C.1    Wedgwood, D.2
  • 26
    • 0015445231 scopus 로고
    • Heat and bone tissue. An experimental investigation of the thermal properties of bone and threshold levels for thermal injury
    • Lundskog J. Heat and bone tissue. An experimental investigation of the thermal properties of bone and threshold levels for thermal injury. Scand J Plast Reconstr Surg 1972;9: 1-80.
    • (1972) Scand J Plast Reconstr Surg , vol.9 , pp. 1-80
    • Lundskog, J.1
  • 27
    • 0015301831 scopus 로고
    • Temperatures measured in human cortical bone when drilling
    • Matthews LS, Hirsch C. Temperatures measured in human cortical bone when drilling. J Bone Joint Surg Am 1972;54: 297-308.
    • (1972) J Bone Joint Surg Am , vol.54 , pp. 297-308
    • Matthews, L.S.1    Hirsch, C.2
  • 30
    • 0029683215 scopus 로고    scopus 로고
    • The effect of speed, pressure, and time on bone temperature during the drilling of implant sites
    • Brisman DL. The effect of speed, pressure, and time on bone temperature during the drilling of implant sites. Int J Oral Maxillofac Implants 1996;11: 35-37.
    • (1996) Int J Oral Maxillofac Implants , vol.11 , pp. 35-37
    • Brisman, D.L.1
  • 31
    • 0031088297 scopus 로고    scopus 로고
    • Heat generation during implant site preparation: An in vitro study
    • Cordioli G, Majzoub Z. Heat generation during implant site preparation: An in vitro study. Int J Oral Maxillofac Implants 1997;12: 186-193.
    • (1997) Int J Oral Maxillofac Implants , vol.12 , pp. 186-193
    • Cordioli, G.1    Majzoub, Z.2
  • 32
    • 0031152012 scopus 로고    scopus 로고
    • Influence of different parameters on bone heating and drilling time in implantology
    • Reingewirtz Y, Szmukler-Moncler S, Senger B. Influence of different parameters on bone heating and drilling time in implantology. Clin Oral Implants Res 1997;8: 189-197.
    • (1997) Clin Oral Implants Res , vol.8 , pp. 189-197
    • Reingewirtz, Y.1    Szmukler-Moncler, S.2    Senger, B.3
  • 33
    • 33644910906 scopus 로고    scopus 로고
    • Piezoelectric osteotomies in craniofacial procedures: A series of 15 pediatric patients. Technical note
    • Kramer FJ, Ludwig HC, Materna T, Gruber R, Merten HA, Schliephake H. Piezoelectric osteotomies in craniofacial procedures: A series of 15 pediatric patients. Technical note. J Neurosurg 2006;104: 68-71.
    • (2006) J Neurosurg , vol.104 , pp. 68-71
    • Kramer, F.J.1    Ludwig, H.C.2    Materna, T.3    Gruber, R.4    Merten, H.A.5    Schliephake, H.6
  • 34
    • 4444267748 scopus 로고    scopus 로고
    • Piezosurgery: An ultrasound device for cutting bone and its use and limitations in maxillofacial surgery
    • Eggers G, Klein J, Blank J, Hassfeld S. Piezosurgery: An ultrasound device for cutting bone and its use and limitations in maxillofacial surgery. Br J Oral Maxillofac Surg 2004;42: 451-453.
    • (2004) Br J Oral Maxillofac Surg , vol.42 , pp. 451-453
    • Eggers, G.1    Klein, J.2    Blank, J.3    Hassfeld, S.4
  • 35
    • 33947545768 scopus 로고    scopus 로고
    • Using the Piezosurgery device: Basics and possibilities
    • Garg AK. Using the Piezosurgery device: Basics and possibilities. Dent Implantol Update 2007;18: 1-4.
    • (2007) Dent Implantol Update , vol.18 , pp. 1-4
    • Garg, A.K.1
  • 36
    • 0030186488 scopus 로고    scopus 로고
    • Temperature changes in bovine mandibular bone during implant site preparation: An assessment using infrared thermography
    • Benington IC, Biagioni PA, Crossey PJ, Hussey DL, Sheridan S, Lamey PJ. Temperature changes in bovine mandibular bone during implant site preparation: An assessment using infrared thermography. J Dent 1996;24: 263-267.
    • (1996) J Dent , vol.24 , pp. 263-267
    • Benington, I.C.1    Biagioni, P.A.2    Crossey, P.J.3    Hussey, D.L.4    Sheridan, S.5    Lamey, P.J.6
  • 37
    • 33750977835 scopus 로고    scopus 로고
    • Sensitivity of the inferior lip and chin following mandibular bilateral sagittal split osteotomy using Piezosurgery
    • Geha HJ, Gleizal AM, Nimeskern NJ, Beziat JL. Sensitivity of the inferior lip and chin following mandibular bilateral sagittal split osteotomy using Piezosurgery. Plast Reconstr Surg 2006;118: 1598-1607.
    • (2006) Plast Reconstr Surg , vol.118 , pp. 1598-1607
    • Geha, H.J.1    Gleizal, A.M.2    Nimeskern, N.J.3    Beziat, J.L.4
  • 38
    • 0027352853 scopus 로고
    • Effects of drill cooling and bone structure on IMZ implant fixation
    • Haider R, Watzek G, Plenk H. Effects of drill cooling and bone structure on IMZ implant fixation. Int J Oral Maxillofac Implants 1993;8: 83-91.
    • (1993) Int J Oral Maxillofac Implants , vol.8 , pp. 83-91
    • Haider, R.1    Watzek, G.2    Plenk, H.3
  • 40
    • 0025874485 scopus 로고
    • Increase of temperature during osteotomy. In vitro and in vivo investigations
    • Wachter R, Stoll P. Increase of temperature during osteotomy. In vitro and in vivo investigations. Int J Oral Maxillofac Surg 1991;20: 245-249.
    • (1991) Int J Oral Maxillofac Surg , vol.20 , pp. 245-249
    • Wachter, R.1    Stoll, P.2
  • 41
    • 21844443546 scopus 로고    scopus 로고
    • Ultrasonic surgery-An alternative way in orthognathic surgery of the mandible. A pilot study
    • Gruber RM, Kramer FJ, Merten HA, Schliephake H. Ultrasonic surgery-An alternative way in orthognathic surgery of the mandible. A pilot study. Int J Oral Maxillofac Surg 2005;34: 590-593.
    • (2005) Int J Oral Maxillofac Surg , vol.34 , pp. 590-593
    • Gruber, R.M.1    Kramer, F.J.2    Merten, H.A.3    Schliephake, H.4
  • 42
    • 34548634088 scopus 로고    scopus 로고
    • Endoscopically assisted intraoral vertical ramus osteotomy and piezoelectric surgery in mandibular prognathism
    • Robiony M, Polini F, Costa F, Sembronio S, Zerman N, Politi M. Endoscopically assisted intraoral vertical ramus osteotomy and piezoelectric surgery in mandibular prognathism. J Oral Maxillofac Surg 2007;65: 2119-2124.
    • (2007) J Oral Maxillofac Surg , vol.65 , pp. 2119-2124
    • Robiony, M.1    Polini, F.2    Costa, F.3    Sembronio, S.4    Zerman, N.5    Politi, M.6
  • 43
    • 58149204335 scopus 로고    scopus 로고
    • Piezoosteotomy in orthognathic surgery versus conventional saw and chisel osteotomy
    • Landes CA, Stubinger S, Ballon A, Sader R. Piezoosteotomy in orthognathic surgery versus conventional saw and chisel osteotomy. Oral Maxillofac Surg 2008;12: 139-147.
    • (2008) Oral Maxillofac Surg , vol.12 , pp. 139-147
    • Landes, C.A.1    Stubinger, S.2    Ballon, A.3    Sader, R.4
  • 44
    • 40749115567 scopus 로고    scopus 로고
    • Critical evaluation of piezoelectric osteotomy in orthognathic surgery: Operative technique, blood loss, time requirement, nerve and vessel integrity
    • Landes CA, Stubinger S, Rieger J, Williger B, Ha TK, Sader R. Critical evaluation of piezoelectric osteotomy in orthognathic surgery: Operative technique, blood loss, time requirement, nerve and vessel integrity. J Oral Maxillofac Surg 2008;66: 657-674.
    • (2008) J Oral Maxillofac Surg , vol.66 , pp. 657-674
    • Landes, C.A.1    Stubinger, S.2    Rieger, J.3    Williger, B.4    Ha, T.K.5    Sader, R.6
  • 45
    • 37249066156 scopus 로고    scopus 로고
    • Piezosurgery in the excision of middle-ear tumors: Effects on mineralized and nonmineralized tissues
    • Salami A, Dellepiane M, Salzano FA, Mora R. Piezosurgery in the excision of middle-ear tumors: Effects on mineralized and nonmineralized tissues. Med Sci Monit 2007;13: 25-29.
    • (2007) Med Sci Monit , vol.13 , pp. 25-29
    • Salami, A.1    Dellepiane, M.2    Salzano, F.A.3    Mora, R.4
  • 46
    • 42249083920 scopus 로고    scopus 로고
    • A novel approach to facial nerve decompression: Use of Piezosurgery
    • Salami A, Dellepiane M, Mora R. A novel approach to facial nerve decompression: Use of Piezosurgery. Acta Otolaryngol 2008;128: 530-533.
    • (2008) Acta Otolaryngol , vol.128 , pp. 530-533
    • Salami, A.1    Dellepiane, M.2    Mora, R.3
  • 49
    • 79955412920 scopus 로고    scopus 로고
    • Evaluation of different methods of indirect sinus floor elevation for elevation heights of 10 mm: An experimental ex vivo study
    • Jun
    • Stelzle F, Benner KU. Evaluation of different methods of indirect sinus floor elevation for elevation heights of 10 mm: An experimental ex vivo study. Clin Implant Dent Relat Res 2011 Jun;13(2): 124-133.
    • (2011) Clin Implant Dent Relat Res , vol.13 , Issue.2 , pp. 124-133
    • Stelzle, F.1    Benner, K.U.2
  • 50
    • 78349231698 scopus 로고    scopus 로고
    • An animal model for sinus floor elevation with great elevation heights. Macroscopic, microscopic, radiological and micro-CT analysis: Ex vivo
    • Stelzle F, Benner KU. An animal model for sinus floor elevation with great elevation heights. Macroscopic, microscopic, radiological and micro-CT analysis: Ex vivo. Clin Oral Implants Res 2010;21: 1370-1378.
    • (2010) Clin Oral Implants Res , vol.21 , pp. 1370-1378
    • Stelzle, F.1    Benner, K.U.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.