The achievable uncertainty for balance-based force standard machines in the range from micronewton to Newton

Author keywords

Electromagnetically compensated balance; Force standard machine; Force transducer; ISO 376; Small forces; Traceability

Indexed keywords

FORCE STANDARD MACHINES; FORCE TRANSDUCERS; ISO 376; SMALL FORCES; TRACEABILITY;

EID: 84871450362     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: None     Document Type: Conference Paper
Times cited : (7)

References (10)
  • 1
    • 27444435640 scopus 로고    scopus 로고
    • A new force measuring facility from the Range of 10 mN to 10 N
    • Dubrovnik
    • S. Niehe, "A New Force Measuring Facility from the Range of 10 mN to 10 N", Proc. of the XVII IMEKO World Congress, Dubrovnik, 2003, pp. 335-340
    • (2003) Proc. of the XVII IMEKO World Congress , pp. 335-340
    • Niehe, S.1
  • 2
    • 84877785713 scopus 로고    scopus 로고
    • Research for a national force standard machine in the range from micro Newton to Newton relying on force compensation
    • September 17-22, Rio de Janeiro
    • J. Illemann, R. Kumme, "Research for a national force standard machine in the range from micro Newton to Newton relying on force compensation," IMEKO 2006 XVIII World Congress, September 17-22, 2006, Rio de Janeiro
    • (2006) IMEKO 2006 XVIII World Congress
    • Illemann, J.1    Kumme, R.2
  • 3
    • 0003492094 scopus 로고
    • Guide to the expression of uncertainty in measurement
    • BIPMIECIFCCISOIUPACIUPAPOIML, ISBN 92-67-10188-9, corrected and reprinted
    • BIPM,IEC,IFCC,ISO,IUPAC,IUPAP,OIML, "Guide to the expression of uncertainty in measurement", Genf 1995, ISBN 92-67-10188-9, corrected and reprinted
    • (1995) Genf
  • 7
    • 0018158694 scopus 로고
    • An investigation on parasitic effects on force standard machines
    • A. Bray, C. Ferrero, R. Levi, C. Marinari, "An investigation on parasitic effects on force standard machines," VDI-Berichte Nr. 312, 1978
    • (1978) VDI-Berichte , Issue.312
    • Bray, A.1    Ferrero, C.2    Levi, R.3    Marinari, C.4
  • 9
    • 4444329666 scopus 로고    scopus 로고
    • Fast torque calibrations using continuous procedures
    • Celle, Germany
    • A. Brüe, "Fast Torque Calibrations Using Continuous Procedures," Proc. of the Joint Int. Conf. IMEKO TC3/TC5/TC20, Celle, Germany, 2002, pp.343-348
    • (2002) Proc. of the Joint Int. Conf. IMEKO TC3/TC5/TC20 , pp. 343-348
    • Brüe, A.1