메뉴 건너뛰기




Volumn 46, Issue 1, 2013, Pages 165-169

Serial analysis of lumen geometry and hemodynamics in human arteriovenous fistula for hemodialysis using magnetic resonance imaging and computational fluid dynamics

Author keywords

Arteriovenous fistula; Computational fluid dynamics; Hemodialysis; Magnetic resonance imaging; Wall shear stress

Indexed keywords

ANATOMICAL LANDMARKS; ARTERIOVENOUS FISTULAS; CENTERLINES; COMPUTATIONAL FLUID DYNAMICS MODELING; CROSS SECTIONAL AREA; DATA SETS; HEMODIALYSIS; HEMODYNAMIC CHANGES; HEMODYNAMIC FORCES; HEMODYNAMIC PARAMETERS; OSCILLATORY SHEAR INDEX; PHASE CONTRAST MRI; PROSPECTIVE STUDY; VASCULAR ACCESS; VOLUMETRIC FLOW RATE; WALL SHEAR STRESS; WSS GRADIENTS;

EID: 84871444979     PISSN: 00219290     EISSN: 18732380     Source Type: Journal    
DOI: 10.1016/j.jbiomech.2012.09.005     Document Type: Article
Times cited : (71)

References (9)
  • 1
    • 38649143671 scopus 로고    scopus 로고
    • The natural history of autologous fistulas as first-time dialysis access in the KDOQI era
    • discussion 420-421
    • Biuckians A., Scott E.C., Meier G.H., Panneton J.M., Glickman M.H. The natural history of autologous fistulas as first-time dialysis access in the KDOQI era. Journal of Vascular Surgery 2008, 47(2):415-421. discussion 420-421.
    • (2008) Journal of Vascular Surgery , vol.47 , Issue.2 , pp. 415-421
    • Biuckians, A.1    Scott, E.C.2    Meier, G.H.3    Panneton, J.M.4    Glickman, M.H.5
  • 2
    • 0035991977 scopus 로고    scopus 로고
    • Low-pressure environment and remodelling of the forearm vein in brescia-cimino haemodialysis access
    • Corpataux J.M., Haesler E., Silacci P., Ris H.B., Hayoz D. Low-pressure environment and remodelling of the forearm vein in brescia-cimino haemodialysis access. Nephrology Dialysis Transplantation 2002, 17(6):1057-1062.
    • (2002) Nephrology Dialysis Transplantation , vol.17 , Issue.6 , pp. 1057-1062
    • Corpataux, J.M.1    Haesler, E.2    Silacci, P.3    Ris, H.B.4    Hayoz, D.5
  • 5
    • 0030087598 scopus 로고    scopus 로고
    • Pulsatile flow in the human left coronary artery bifurcation: average conditions
    • He X., Ku D.N. Pulsatile flow in the human left coronary artery bifurcation: average conditions. Journal of Biomechanical Engineering 1996, 118(1):74-82.
    • (1996) Journal of Biomechanical Engineering , vol.118 , Issue.1 , pp. 74-82
    • He, X.1    Ku, D.N.2
  • 6
    • 84863316356 scopus 로고    scopus 로고
    • Computational fluid dynamics simulation of A-V fistulas: from MRI and ultrasound scans to numeric evaluation of hemodynamics
    • Niemann A.K., Thrysoe S., Nygaard J.V., Hasenkam J.M., Petersen S.E. Computational fluid dynamics simulation of A-V fistulas: from MRI and ultrasound scans to numeric evaluation of hemodynamics. The Journal of Vascular Access 2012, 13(1):36-44.
    • (2012) The Journal of Vascular Access , vol.13 , Issue.1 , pp. 36-44
    • Niemann, A.K.1    Thrysoe, S.2    Nygaard, J.V.3    Hasenkam, J.M.4    Petersen, S.E.5
  • 7
    • 0029329172 scopus 로고
    • Computer simulation of local blood flow and vessel mechanics in a compliant carotid artery bifurcation model
    • Perktold K., Rappitsch G. Computer simulation of local blood flow and vessel mechanics in a compliant carotid artery bifurcation model. Journal of Biomechanics 1995, 28(7):845-856.
    • (1995) Journal of Biomechanics , vol.28 , Issue.7 , pp. 845-856
    • Perktold, K.1    Rappitsch, G.2
  • 8
    • 57049089436 scopus 로고    scopus 로고
    • Longitudinal assessment of hyperplasia using magnetic resonance imaging without contrast in a porcine arteriovenous graft model
    • Terry C.M., Kim S.E., Li L., Goodrich K.C., Hadley J.R., Blumenthal D.K., Parker D.L., Cheung A.K. Longitudinal assessment of hyperplasia using magnetic resonance imaging without contrast in a porcine arteriovenous graft model. Academic Radiology 2009, 16(1):96-107.
    • (2009) Academic Radiology , vol.16 , Issue.1 , pp. 96-107
    • Terry, C.M.1    Kim, S.E.2    Li, L.3    Goodrich, K.C.4    Hadley, J.R.5    Blumenthal, D.K.6    Parker, D.L.7    Cheung, A.K.8
  • 9
    • 28444487454 scopus 로고    scopus 로고
    • Comparison of the hemodynamics in 6mm and 4-7mm hemodialysis grafts by means of CFD
    • Van Tricht I., De Wachter D., Tordoir J., Verdonck P. Comparison of the hemodynamics in 6mm and 4-7mm hemodialysis grafts by means of CFD. Journal of Biomechanics 2006, 39(2):226-236.
    • (2006) Journal of Biomechanics , vol.39 , Issue.2 , pp. 226-236
    • Van Tricht, I.1    De Wachter, D.2    Tordoir, J.3    Verdonck, P.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.