-
1
-
-
0028284239
-
Plate and screw fixation for atlanto-axial subluxation
-
DOI 10.1007/BF01400872
-
A. Goel, and V. Laheri Plate and screw fixation for atlantoaxial subluxation Acta Neurochir (Wien) 129 1994 47 53 (Pubitemid 24225619)
-
(1994)
Acta Neurochirurgica
, vol.129
, Issue.1-2
, pp. 47-53
-
-
Goel, A.1
Laheri, V.2
-
2
-
-
0035890208
-
Posterior C1-C2 fusion with polyaxial screw and rod fixation
-
DOI 10.1097/00007632-200111150-00014
-
J. Harms, and R.P. Melcher Posterior C1-C2 fusion with polyaxial screw and rod fixation Spine (Phila Pa 1976) 26 2001 2467 2471 (Pubitemid 33065058)
-
(2001)
Spine
, vol.26
, Issue.22
, pp. 2467-2471
-
-
Harms, J.1
Melcher, R.P.2
-
3
-
-
40949125097
-
Stabilization of the atlantoaxial complex via C-1 lateral mass and C-2 pedicle screw fixation in a multicenter clinical experience in 102 patients: Modification of the Harms and Goel techniques
-
DOI 10.3171/SPI/2008/8/3/222
-
H.E. Aryan, C.B. Newman, and E.W. Nottmeier Stabilization of the atlantoaxial complex via C-1 lateral mass and C-2 pedicle screw fixation in a multicenter clinical experience in 102 patients: modification of the Harms and Goel techniques J Neurosurg Spine 8 2008 222 229 (Pubitemid 351413950)
-
(2008)
Journal of Neurosurgery: Spine
, vol.8
, Issue.3
, pp. 222-229
-
-
Aryan, H.E.1
Newman, C.B.2
Nottmeier, E.W.3
Acosta Jr., F.L.4
Wang, V.Y.5
Ames, C.P.6
-
4
-
-
58149105507
-
Posterior atlantal lateral mass fixation technique with polyaxial screw and rod fixation system
-
T. Calişaneller, C. Yilmaz, and O. Ozdemir Posterior atlantal lateral mass fixation technique with polyaxial screw and rod fixation system Turk Neurosurg 18 2008 142 148
-
(2008)
Turk Neurosurg
, vol.18
, pp. 142-148
-
-
Calişaneller, T.1
Yilmaz, C.2
Ozdemir, O.3
-
5
-
-
18244378742
-
Atlantal lateral mass screws for posterior spinal reconstruction: Technical note and case series
-
A.J. Fiore, R.W. Haid, and G.E. Rodts Atlantal lateral mass screws for posterior spinal reconstruction: technical note and case series Neurosurg Focus 12 2002 E5
-
(2002)
Neurosurg Focus
, vol.12
, pp. 5
-
-
Fiore, A.J.1
Haid, R.W.2
Rodts, G.E.3
-
6
-
-
0036954405
-
Atlantoaxial fixation using plate and screw method: A report of 160 treated patients
-
A. Goel, K.I. Desai, and D. Mazumdar Atlantoaxial fixation using plate and screw method: a report of 160 treated patients Neurosurgery 51 2002 1351 1356
-
(2002)
Neurosurgery
, vol.51
, pp. 1351-1356
-
-
Goel, A.1
Desai, K.I.2
Mazumdar, D.3
-
7
-
-
77952545543
-
Clinical and radiological comparison of treatment of atlantoaxial instability by posterior C1-C2 transarticular screw fixation or C1 lateral mass-C2 pedicle screw fixation
-
S.H. Lee, E.S. Kim, and J.K. Sung Clinical and radiological comparison of treatment of atlantoaxial instability by posterior C1-C2 transarticular screw fixation or C1 lateral mass-C2 pedicle screw fixation J Clin Neurosci 17 2010 886 892
-
(2010)
J Clin Neurosci
, vol.17
, pp. 886-892
-
-
Lee, S.H.1
Kim, E.S.2
Sung, J.K.3
-
8
-
-
70349673304
-
Ideal screw entry point and projection angles for posterior lateral mass fixation of the atlas: An anatomical study
-
S. Simsek, K. Yigitkanli, and H. Seçkin Ideal screw entry point and projection angles for posterior lateral mass fixation of the atlas: an anatomical study Eur Spine J 18 2009 1321 1325
-
(2009)
Eur Spine J
, vol.18
, pp. 1321-1325
-
-
Simsek, S.1
Yigitkanli, K.2
Seçkin, H.3
-
9
-
-
77951106026
-
C1 lateral mass screw-induced occipital neuralgia: A report of two cases
-
E. Conroy, A. Laing, and R. Kenneally C1 lateral mass screw-induced occipital neuralgia: a report of two cases Eur Spine J 19 2010 474 476
-
(2010)
Eur Spine J
, vol.19
, pp. 474-476
-
-
Conroy, E.1
Laing, A.2
Kenneally, R.3
-
10
-
-
34249794838
-
The use of C1 lateral mass screws in complex cervical spine surgery: Indications, techniques, and outcome in a prospective consecutive series of 25 cases
-
DOI 10.1097/01.bsd.0000211291.21766.4d, PII 0002472020070600000009
-
T. Gunnarsson, E.M. Massicotte, and P.V. Govender The use of C1 lateral mass screws in complex cervical spine surgery: indications, techniques, and outcome in a prospective consecutive series of 25 cases J Spinal Disord Tech 20 2007 308 316 (Pubitemid 46849992)
-
(2007)
Journal of Spinal Disorders and Techniques
, vol.20
, Issue.4
, pp. 308-316
-
-
Gunnarsson, T.1
Massicotte, E.M.2
Govender, P.V.3
Raja Rampersaud, Y.4
Fehlings, M.G.5
-
11
-
-
0036481526
-
C1-C2 pedicle screw fixation with rigid cantilever beam construct: Case report and technical note
-
DOI 10.1097/00006123-200202000-00039
-
D.K. Resnick, and E.C. Benzel C1-C2 pedicle screw fixation with rigid cantilever beam construct: case report and technical note Neurosurgery 50 2002 426 428 (Pubitemid 41672607)
-
(2002)
Neurosurgery
, vol.50
, Issue.2
, pp. 426-428
-
-
Resnick, D.K.1
Benzel, E.C.2
-
12
-
-
34047125860
-
Working area, safety zones, and angles of approach for posterior C-1 lateral mass screw placement: A quantitative anatomical and morphometric evaluation
-
DOI 10.3171/spi.2007.6.3.247
-
R. Rocha, S. Safavi-Abbasi, and C. Reis Working area, safety zones, and angles of approach for posterior C-1 lateral mass screw placement: a quantitative anatomical and morphometric evaluation J Neurosurg Spine 6 2007 247 254 (Pubitemid 47066077)
-
(2007)
Journal of Neurosurgery: Spine
, vol.6
, Issue.3
, pp. 247-254
-
-
Rocha, R.1
Safavi-Abbasi, S.2
Reis, C.3
Theodore, N.4
Bambakidis, N.5
De Oliveira, E.6
Sonntag, V.K.H.7
Crawford, N.R.8
-
13
-
-
22144490815
-
Anatomic considerations for the pedicle screw placement in the first cervical vertebra
-
X.Y. Ma, Q.S. Yin, and Z.H. Wu Anatomic considerations for the pedicle screw placement in the first cervical vertebra Spine (Phila Pa 1976) 30 2005 1519 1523
-
(2005)
Spine (Phila Pa 1976)
, vol.30
, pp. 1519-1523
-
-
Ma, X.Y.1
Yin, Q.S.2
Wu, Z.H.3
-
14
-
-
77957999305
-
C1 lateral mass screw insertion with protection of C1-C2 venous sinus: Technical note and review of the literature
-
J. Pan, L. Li, and L. Qian C1 lateral mass screw insertion with protection of C1-C2 venous sinus: technical note and review of the literature Spine (Phila Pa 1976) 35 2010 E1133 E1136
-
(2010)
Spine (Phila Pa 1976)
, vol.35
-
-
Pan, J.1
Li, L.2
Qian, L.3
-
15
-
-
34247350051
-
Atlantoaxial fixation using the polyaxial screw-rod system
-
DOI 10.1007/s00586-006-0241-6
-
J. Stulik, T. Vyskocil, and P. Sebesta Atlantoaxial fixation using the polyaxial screw-rod system Eur Spine J 16 2007 479 484 (Pubitemid 46628647)
-
(2007)
European Spine Journal
, vol.16
, Issue.4
, pp. 479-484
-
-
Stulik, J.1
Vyskocil, T.2
Sebesta, P.3
Kryl, J.4
-
16
-
-
77951112945
-
Troublesome occipital neuralgia developed by c1-c2 harms construct
-
W.T. Rhee, S.H. You, and S.K. Kim Troublesome occipital neuralgia developed by c1-c2 harms construct J Korean Neurosurg Soc 43 2008 111 113
-
(2008)
J Korean Neurosurg Soc
, vol.43
, pp. 111-113
-
-
Rhee, W.T.1
You, S.H.2
Kim, S.K.3
-
17
-
-
77956927445
-
C1 lateral mass screw placement with intentional sacrifice of the C2 ganglion: Functional outcomes and morbidity in elderly patients
-
J. Squires, and R.W. Molinari C1 lateral mass screw placement with intentional sacrifice of the C2 ganglion: functional outcomes and morbidity in elderly patients Eur Spine J 19 2010 1318 1324
-
(2010)
Eur Spine J
, vol.19
, pp. 1318-1324
-
-
Squires, J.1
Molinari, R.W.2
-
18
-
-
0037626143
-
Morphometric evaluation of screw fixation in atlas via posterior arch and lateral mass
-
DOI 10.1097/00007632-200305010-00010
-
M. Tan, H. Wang, and Y. Wang Morphometric evaluation of screw fixation in atlas via posterior arch and lateral mass Spine (Phila Pa 1976) 28 2003 888 895 (Pubitemid 36542756)
-
(2003)
Spine
, vol.28
, Issue.9
, pp. 888-895
-
-
Tan, M.1
Wang, H.2
Wang, Y.3
Zhang, G.4
Yi, P.5
Li, Z.6
Wei, H.7
Yang, F.8
-
19
-
-
64749096163
-
C1 pedicle screws versus C1 lateral mass screws: Comparisons of pullout strengths and biomechanical stabilities
-
X.Y. Ma, Q.S. Yin, and Z.H. Wu C1 pedicle screws versus C1 lateral mass screws: comparisons of pullout strengths and biomechanical stabilities Spine (Phila Pa 1976) 34 2009 371 377
-
(2009)
Spine (Phila Pa 1976)
, vol.34
, pp. 371-377
-
-
Ma, X.Y.1
Yin, Q.S.2
Wu, Z.H.3
-
20
-
-
33751099827
-
The feasibility of inserting atlas lateral mass screws via the posterior arch
-
DOI 10.1097/01.brs.0000245902.93084.12, PII 0000763220061115000009
-
M.J. Lee, E. Cassinelli, and K.D. Riew The feasibility of inserting atlas lateral mass screws via the posterior arch Spine (Phila Pa 1976) 31 2006 2798 2801 (Pubitemid 44772780)
-
(2006)
Spine
, vol.31
, Issue.24
, pp. 2798-2801
-
-
Lee, M.J.1
Cassinelli, E.2
Riew, K.D.3
-
21
-
-
33750714051
-
Biomechanical comparison of two new atlantoaxial fixation techniques with C1-2 transarticular screw-graft fixation
-
DOI 10.3171/spi.2006.5.4.336
-
R. Härtl, R.H. Chamberlain, and M.S. Fifield Biomechanical comparison of two new atlantoaxial fixation techniques with C1-2 transarticular screw-graft fixation J Neurosurg Spine 5 2006 336 342 (Pubitemid 47325373)
-
(2006)
Journal of Neurosurgery: Spine
, vol.5
, Issue.4
, pp. 336-342
-
-
Hartl, R.1
Chamberlain, R.H.2
Fifield, M.S.3
Chou, D.4
Sonntag, V.K.H.5
Crawford, N.R.6
-
23
-
-
34948893936
-
Biomechanical comparison of unicortical versus bicortical C1 lateral mass screw fixation
-
DOI 10.1097/BSD.0b013e318031af8b, PII 0002472020071000000004
-
J.C. Eck, M.P. Walker, and B.L. Currier Biomechanical comparison of unicortical versus bicortical C1 lateral mass screw fixation J Spinal Disord Tech 20 2007 505 508 (Pubitemid 47524955)
-
(2007)
Journal of Spinal Disorders and Techniques
, vol.20
, Issue.7
, pp. 505-508
-
-
Eck, J.C.1
Walker, M.P.2
Currier, B.L.3
Chen, Q.4
Yaszemski, M.J.5
An, K.-N.6
|