메뉴 건너뛰기




Volumn 387, Issue 1-2, 2013, Pages 303-307

Standardisation of metalloimmunoassay protocols for assessment of silver nanoparticle antibody conjugates

Author keywords

Cardiac markers; Immunoassay; Metalloimmunoassay; Point of care diagnostics; Silver nanoparticles; Troponin

Indexed keywords

ANTIBODY CONJUGATE; SILVER NANOPARTICLE; THIOCYANIC ACID DERIVATIVE;

EID: 84871406783     PISSN: 00221759     EISSN: 18727905     Source Type: Journal    
DOI: 10.1016/j.jim.2012.08.001     Document Type: Article
Times cited : (9)

References (12)
  • 1
    • 52649134531 scopus 로고    scopus 로고
    • Ischaemic heart disease - the universal definition of myocardial infarction: a consensus document
    • Alpert J.S., Thygesen K., Jaffe A., White H.D. Ischaemic heart disease - the universal definition of myocardial infarction: a consensus document. Heart 2008, 94:1335.
    • (2008) Heart , vol.94 , pp. 1335
    • Alpert, J.S.1    Thygesen, K.2    Jaffe, A.3    White, H.D.4
  • 3
    • 72849140901 scopus 로고    scopus 로고
    • The use of nanoparticles in electroanalysis: an updated review
    • Campbell F.W., Compton R.G. The use of nanoparticles in electroanalysis: an updated review. Anal. Bioanal. Chem. 2010, 396:241.
    • (2010) Anal. Bioanal. Chem. , vol.396 , pp. 241
    • Campbell, F.W.1    Compton, R.G.2
  • 4
    • 0034669305 scopus 로고    scopus 로고
    • An electrochemical metalloimmunoassay based on a colloidal gold label
    • Dequaire M., Degrand C., Limoges B. An electrochemical metalloimmunoassay based on a colloidal gold label. Anal. Chem. 2000, 72:5521.
    • (2000) Anal. Chem. , vol.72 , pp. 5521
    • Dequaire, M.1    Degrand, C.2    Limoges, B.3
  • 5
    • 23044501741 scopus 로고    scopus 로고
    • Combining different biochemical markers of myocardial ischemia does not improve risk stratification in chest pain patients compared to troponin I alone
    • Eggers K.M., Oldgren J., Nordenskjold A., Lindahl B. Combining different biochemical markers of myocardial ischemia does not improve risk stratification in chest pain patients compared to troponin I alone. Coron. Artery Dis. 2005, 16:315.
    • (2005) Coron. Artery Dis. , vol.16 , pp. 315
    • Eggers, K.M.1    Oldgren, J.2    Nordenskjold, A.3    Lindahl, B.4
  • 6
    • 70649110007 scopus 로고    scopus 로고
    • Dynamic light scattering as a powerful tool for gold nanoparticle bioconjugation and biomolecular binding studies
    • Jans H., Liu X., Austin L., Maes G., Huo Q. Dynamic light scattering as a powerful tool for gold nanoparticle bioconjugation and biomolecular binding studies. Anal. Chem. 2009, 81:9425.
    • (2009) Anal. Chem. , vol.81 , pp. 9425
    • Jans, H.1    Liu, X.2    Austin, L.3    Maes, G.4    Huo, Q.5
  • 7
    • 58149267695 scopus 로고    scopus 로고
    • Evaluation of high-sensitivity assays for cardiac troponin
    • Morrow D.A., Antman E.M. Evaluation of high-sensitivity assays for cardiac troponin. Clin. Chem. 2009, 55:5.
    • (2009) Clin. Chem. , vol.55 , pp. 5
    • Morrow, D.A.1    Antman, E.M.2
  • 11
    • 74249110829 scopus 로고    scopus 로고
    • Electrochemical dissolution of silver nanoparticles and its application in metalloimmunoassay
    • Szymanski M., Turner A.P.F., Porter R. Electrochemical dissolution of silver nanoparticles and its application in metalloimmunoassay. Electroanalysis 2009, 22:191.
    • (2009) Electroanalysis , vol.22 , pp. 191
    • Szymanski, M.1    Turner, A.P.F.2    Porter, R.3
  • 12
    • 21844471002 scopus 로고    scopus 로고
    • Point-of-care immunotesting: approaching the analytical performance of central laboratory methods
    • von Lode P. Point-of-care immunotesting: approaching the analytical performance of central laboratory methods. Clin. Biochem. 2005, 38:591.
    • (2005) Clin. Biochem. , vol.38 , pp. 591
    • von Lode, P.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.