메뉴 건너뛰기




Volumn 5, Issue 12, 2012, Pages 1198-1200

Application of 3D echocardiography to everyday practice: Development of normal ranges is step 1

Author keywords

3 dimensional echocardiography; ejection fraction; LV volumes

Indexed keywords

AUTOMATION; CONTRAST ENHANCEMENT; ENDOCARDIUM; GENDER; HEART AFTERLOAD; HEART EJECTION FRACTION; HEART LEFT VENTRICLE VOLUME; HEART RATE; HUMAN; IMAGE QUALITY; OPTICAL RESOLUTION; PRACTICE GUIDELINE; PRIORITY JOURNAL; RACE; REFERENCE VALUE; REVIEW; THREE DIMENSIONAL ECHOCARDIOGRAPHY; TWO DIMENSIONAL ECHOCARDIOGRAPHY;

EID: 84871373578     PISSN: 1936878X     EISSN: 18767591     Source Type: Journal    
DOI: 10.1016/j.jcmg.2012.09.005     Document Type: Editorial
Times cited : (10)

References (12)
  • 1
    • 79951887922 scopus 로고    scopus 로고
    • Current and evolving echocardiographic techniques for the quantitative evaluation of cardiac mechanics: ASE/EAE consensus statement on methodology and indications endorsed by the Japanese Society of Echocardiography
    • V. Mor-Avi, R.M. Lang, L.P. Badano Current and evolving echocardiographic techniques for the quantitative evaluation of cardiac mechanics: ASE/EAE consensus statement on methodology and indications endorsed by the Japanese Society of Echocardiography J Am Soc Echocardiogr 24 2011 277 313
    • (2011) J Am Soc Echocardiogr , vol.24 , pp. 277-313
    • Mor-Avi, V.1    Lang, R.M.2    Badano, L.P.3
  • 2
    • 84863986165 scopus 로고    scopus 로고
    • Meta-analysis of accuracy of left ventricular mass measurement by three-dimensional echocardiography
    • Y.J. Shimada, T. Shiota Meta-analysis of accuracy of left ventricular mass measurement by three-dimensional echocardiography Am J Cardiol 110 2012 445 452
    • (2012) Am J Cardiol , vol.110 , pp. 445-452
    • Shimada, Y.J.1    Shiota, T.2
  • 3
    • 78650113495 scopus 로고    scopus 로고
    • A meta-analysis and investigation for the source of bias of left ventricular volumes and function by three-dimensional echocardiography in comparison with magnetic resonance imaging
    • Y.J. Shimada, T. Shiota A meta-analysis and investigation for the source of bias of left ventricular volumes and function by three-dimensional echocardiography in comparison with magnetic resonance imaging Am J Cardiol 107 2011 126 138
    • (2011) Am J Cardiol , vol.107 , pp. 126-138
    • Shimada, Y.J.1    Shiota, T.2
  • 5
    • 76649113752 scopus 로고    scopus 로고
    • Reference values for left ventricular volumes with real-time 3-dimensional echocardiography
    • E. Aune, M. Baekkevar, O. Rodevand, J.E. Otterstad Reference values for left ventricular volumes with real-time 3-dimensional echocardiography Scand Cardiovasc J 44 2010 24 30
    • (2010) Scand Cardiovasc J , vol.44 , pp. 24-30
    • Aune, E.1    Baekkevar, M.2    Rodevand, O.3    Otterstad, J.E.4
  • 6
    • 84860157001 scopus 로고    scopus 로고
    • Normal values of real-time 3-dimensional echocardiographic parameters in a healthy Japanese population: The JAMP-3D Study
    • S. Fukuda, H. Watanabe, M. Daimon Normal values of real-time 3-dimensional echocardiographic parameters in a healthy Japanese population: the JAMP-3D Study Circ J 76 2012 1177 1181
    • (2012) Circ J , vol.76 , pp. 1177-1181
    • Fukuda, S.1    Watanabe, H.2    Daimon, M.3
  • 7
    • 47349116645 scopus 로고    scopus 로고
    • Real-time 3-dimensional echocardiographic quantification of left ventricular volumes: Multicenter study for validation with magnetic resonance imaging and investigation of sources of error
    • V. Mor-Avi, C. Jenkins, H.P. Kühl Real-time 3-dimensional echocardiographic quantification of left ventricular volumes: multicenter study for validation with magnetic resonance imaging and investigation of sources of error J Am Coll Cardiol Img 1 2008 413 423
    • (2008) J Am Coll Cardiol Img , vol.1 , pp. 413-423
    • Mor-Avi, V.1    Jenkins, C.2    Kühl, H.P.3
  • 8
    • 84863342262 scopus 로고    scopus 로고
    • Feasibility, accuracy, and reproducibility of real-time full-volume 3D transthoracic echocardiography to measure LV volumes and systolic function: A fully automated endocardial contouring algorithm in sinus rhythm and atrial fibrillation
    • P. Thavendiranathan, S. Liu, D. Verhaert Feasibility, accuracy, and reproducibility of real-time full-volume 3D transthoracic echocardiography to measure LV volumes and systolic function: a fully automated endocardial contouring algorithm in sinus rhythm and atrial fibrillation J Am Coll Cardiol Img 5 2012 239 251
    • (2012) J Am Coll Cardiol Img , vol.5 , pp. 239-251
    • Thavendiranathan, P.1    Liu, S.2    Verhaert, D.3
  • 9
    • 58149171451 scopus 로고    scopus 로고
    • Left ventricular volume measurement with echocardiography: A comparison of left ventricular opacification, three-dimensional echocardiography, or both with magnetic resonance imaging
    • C. Jenkins, S. Moir, J. Chan, D. Rakhit, B. Haluska, T.H. Marwick Left ventricular volume measurement with echocardiography: a comparison of left ventricular opacification, three-dimensional echocardiography, or both with magnetic resonance imaging Eur Heart J 30 2009 98 106
    • (2009) Eur Heart J , vol.30 , pp. 98-106
    • Jenkins, C.1    Moir, S.2    Chan, J.3    Rakhit, D.4    Haluska, B.5    Marwick, T.H.6
  • 10
    • 33748090271 scopus 로고    scopus 로고
    • Accuracy and feasibility of online 3-dimensional echocardiography for measurement of left ventricular parameters
    • C. Jenkins, J. Chan, L. Hanekom, T.H. Marwick Accuracy and feasibility of online 3-dimensional echocardiography for measurement of left ventricular parameters J Am Soc Echocardiogr 19 2006 1119 1128
    • (2006) J Am Soc Echocardiogr , vol.19 , pp. 1119-1128
    • Jenkins, C.1    Chan, J.2    Hanekom, L.3    Marwick, T.H.4
  • 11
    • 48949098859 scopus 로고    scopus 로고
    • 2008 focused update incorporated into the ACC/AHA 2006 guidelines for the management of patients with valvular heart disease: A report of the American College of Cardiology
    • American Heart Association Task Force on Practice Guidelines (Writing Committee to Revise the 1998 Guidelines for the Management of Patients with Valvular Heart Disease) Endorsed by the Society of Cardiovascular Anesthesiologists, Society for Cardiovascular Angiography and Interventions, and Society of Thoracic SurgeonsAmerican College of Cardiology/American Heart Association Task Force on Practice Guidelines
    • R.O. Bonow, B.A. Carabello, K. Chatterjee American College of Cardiology/American Heart Association Task Force on Practice Guidelines 2008 focused update incorporated into the ACC/AHA 2006 guidelines for the management of patients with valvular heart disease: a report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (Writing Committee to Revise the 1998 Guidelines for the Management of Patients With Valvular Heart Disease) Endorsed by the Society of Cardiovascular Anesthesiologists, Society for Cardiovascular Angiography and Interventions, and Society of Thoracic Surgeons J Am Coll Cardiol 52 2008 e1 e142
    • (2008) J Am Coll Cardiol , vol.52
    • Bonow, R.O.1    Carabello, B.A.2    Chatterjee, K.3
  • 12
    • 4444225006 scopus 로고    scopus 로고
    • Comparison of real-time 3-dimensional echocardiography with conventional 2-dimensional echocardiography in the assessment of structural heart disease
    • K.L. Chan, X. Liu, K.J. Ascah, L.M. Beauchesne, I.G. Burwash Comparison of real-time 3-dimensional echocardiography with conventional 2-dimensional echocardiography in the assessment of structural heart disease J Am Soc Echocardiogr 17 2004 976 980
    • (2004) J Am Soc Echocardiogr , vol.17 , pp. 976-980
    • Chan, K.L.1    Liu, X.2    Ascah, K.J.3    Beauchesne, L.M.4    Burwash, I.G.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.