메뉴 건너뛰기




Volumn 10, Issue 1, 2012, Pages 24-33

Pulmonary vein isolation in 2012: Is it necessary to perform a time consuming electrophysical mapping or should we focus on rapid and safe therapies? A retrospective analysis of different ablation tools

Author keywords

Atrial fibrillation; Different ablation tools; Fluoroscopy time; Procedure duration; Safety

Indexed keywords

ADULT; ARTICLE; CARDIOVASCULAR EQUIPMENT; DEVICE SAFETY; DISEASE ASSOCIATION; EQUIPMENT DESIGN; FEMALE; FOLLOW UP; HEART ATRIUM FIBRILLATION; HEART ELECTROPHYSIOLOGY; HUMAN; LEARNING CURVE; MAJOR CLINICAL STUDY; MALE; MEDICAL HISTORY; PULMONARY VEIN ISOLATION; RECURRENT DISEASE; RETROSPECTIVE STUDY; THERAPY EFFECT; TREND STUDY;

EID: 84871354781     PISSN: 14491907     EISSN: None     Source Type: Journal    
DOI: 10.7150/ijms.4771     Document Type: Article
Times cited : (16)

References (27)
  • 3
    • 77649090185 scopus 로고    scopus 로고
    • State-of-the-art and emerging technologies for atrial fibrillation ablation
    • Mar
    • Dewire, J., Calkins, H. State-of-the-art and emerging technologies for atrial fibrillation ablation. Nat Rev Cardiol. 2010 Mar;7(3): 129-38.
    • (2010) Nat Rev Cardiol , vol.7 , Issue.3 , pp. 129-138
    • Dewire, J.1    Calkins, H.2
  • 4
    • 68749092708 scopus 로고    scopus 로고
    • Segmental pulmonary vein isolation in atrial fibrillation: New insights from the high density mesh mapper technique in an electrophysiologically guided approach
    • Sep
    • Meissner A, van Bracht M, Schrage MO, Christ M, Trappe HJ, Maagh P et al. Segmental pulmonary vein isolation in atrial fibrillation: new insights from the high density mesh mapper technique in an electrophysiologically guided approach. J Interv Card Electrophysiol. 2009 Sep;25(3): 183-92.
    • (2009) J Interv Card Electrophysiol , vol.25 , Issue.3 , pp. 183-192
    • Meissner, A.1    van Bracht, M.2    Schrage, M.O.3    Christ, M.4    Trappe, H.J.5    Maagh, P.6
  • 5
    • 63049117972 scopus 로고    scopus 로고
    • First Experiences for Pulmonary Vein Isolation with the High-Density Mesh Ablator (HDMA): A Novel Mesh Electrode Catheter for Both Mapping and Radiofrequency Delivery in a Single Unit
    • Apr
    • Meissner A, Plehn G, van Bracht M, Schrage MO, Christ M, Maagh P et al. First Experiences for Pulmonary Vein Isolation with the High-Density Mesh Ablator (HDMA): A Novel Mesh Electrode Catheter for Both Mapping and Radiofrequency Delivery in a Single Unit. J Cardiovasc Electrophysiol. 2009 Apr; 20(4): 359-66.
    • (2009) J Cardiovasc Electrophysiol , vol.20 , Issue.4 , pp. 359-366
    • Meissner, A.1    Plehn, G.2    van Bracht, M.3    Schrage, M.O.4    Christ, M.5    Maagh, P.6
  • 6
    • 34548803112 scopus 로고    scopus 로고
    • Pulmonary vein isolation using an occluding cryoballoon for circumferential ablation: Feasibility, complications, and shortterm outcome
    • Sep
    • Van Belle Y, Janse P, Rivero-Ayerza MJ, Thornton AS, Jessurun ER, Theuns D et al. Pulmonary vein isolation using an occluding cryoballoon for circumferential ablation: feasibility, complications, and shortterm outcome. Eur Heart J. 2007 Sep; 28(18): 2231-7.
    • (2007) Eur Heart J , vol.28 , Issue.18 , pp. 2231-2237
    • van Belle, Y.1    Janse, P.2    Rivero-Ayerza, M.J.3    Thornton, A.S.4    Jessurun, E.R.5    Theuns, D.6
  • 7
    • 64949092842 scopus 로고    scopus 로고
    • The 'single big cryoballoon' technique for acute pulmonary vein isolation in patients with paroxysmal atrial fibrillation: A prospective observational single centre study
    • Mar
    • Chun KR, Schmidt B, Metzner A, Tilz R, Zerm T, Köster I et al. The 'single big cryoballoon' technique for acute pulmonary vein isolation in patients with paroxysmal atrial fibrillation: a prospective observational single centre study. Eur Heart J. 2009 Mar;30(6): 636.
    • (2009) Eur Heart J , vol.30 , Issue.6 , pp. 636
    • Chun, K.R.1    Schmidt, B.2    Metzner, A.3    Tilz, R.4    Zerm, T.5    Köster, I.6
  • 8
    • 47149112945 scopus 로고    scopus 로고
    • Circumferential Pulmonary Vein Isolation With the Cryoballoon Technique Results From a Prospective 3-Center Study
    • Jul 22
    • Neumann T, Vogt J, Schumacher B, Dorszewski A, Kuniss M, Neuser H et al. Circumferential Pulmonary Vein Isolation With the Cryoballoon Technique Results From a Prospective 3-Center Study. J Am Coll Cardiol. 2008 Jul 22; 52(4): 273-8.
    • (2008) J Am Coll Cardiol , vol.52 , Issue.4 , pp. 273-278
    • Neumann, T.1    Vogt, J.2    Schumacher, B.3    Dorszewski, A.4    Kuniss, M.5    Neuser, H.6
  • 9
    • 77953623229 scopus 로고    scopus 로고
    • Acute and long-term results of PVI at antrum using a novel high-density mapping catheter without help of 3D electro-anatomic mapping in patients with paroxysmal and chronic atrial fibrillation
    • Mar
    • Neumann T, Kuniss M, Erkapic D, Zaltsberg S, Berkowitsch A, Pajitnev D et al. Acute and long-term results of PVI at antrum using a novel high-density mapping catheter without help of 3D electro-anatomic mapping in patients with paroxysmal and chronic atrial fibrillation. J Interv Card Electrophysiol. 2010 Mar; 27(2): 101-8.
    • (2010) J Interv Card Electrophysiol , vol.27 , Issue.2 , pp. 101-108
    • Neumann, T.1    Kuniss, M.2    Erkapic, D.3    Zaltsberg, S.4    Berkowitsch, A.5    Pajitnev, D.6
  • 10
    • 59149090029 scopus 로고    scopus 로고
    • Acute Results of Pulmonary Vein Isolation in Patients with Paroxysmal Atrial Fibrillation Using a Single Mesh Catheter
    • Feb
    • Steinwender C, Hoenig S, Leisch F, Hofmann R. Acute Results of Pulmonary Vein Isolation in Patients with Paroxysmal Atrial Fibrillation Using a Single Mesh Catheter. J Cardiovasc Electrophysiol. 2009 Feb; 20(2): 147-52.
    • (2009) J Cardiovasc Electrophysiol , vol.20 , Issue.2 , pp. 147-152
    • Steinwender, C.1    Hoenig, S.2    Leisch, F.3    Hofmann, R.4
  • 11
    • 77149158461 scopus 로고    scopus 로고
    • One-year follow-up after pulmonary vein isolation using a single mesh catheter in patients with paroxysmal atrial fibrillation
    • Steinwender C, Hoenig S, Leisch F, Hofmann R. One-year follow-up after pulmonary vein isolation using a single mesh catheter in patients with paroxysmal atrial fibrillation. Heart Rhythm 2010; 7: 333-339.
    • (2010) Heart Rhythm , vol.7 , pp. 333-339
    • Steinwender, C.1    Hoenig, S.2    Leisch, F.3    Hofmann, R.4
  • 12
    • 78049453574 scopus 로고    scopus 로고
    • Eighteen months follow-up of the clinical efficacy of the high density mesh ablator (HDMA) in patients with atrial fibrillation after pulmonary vein isolation
    • Oct
    • Maagh P, van Bracht M, Butz T, Trappe HJ, Meissner A. Eighteen months follow-up of the clinical efficacy of the high density mesh ablator (HDMA) in patients with atrial fibrillation after pulmonary vein isolation. J Interv Card Electrophysiol. 2010 Oct; 29(1): 43-52.
    • (2010) J Interv Card Electrophysiol , vol.29 , Issue.1 , pp. 43-52
    • Maagh, P.1    van Bracht, M.2    Butz, T.3    Trappe, H.J.4    Meissner, A.5
  • 13
    • 33846386030 scopus 로고    scopus 로고
    • A novel Mesh electrode catheter for mapping and radiofrequency delivery at the left atrium-pulmonary vein junction: A simplified approach to pulmonary vein isolation
    • Arruda MS, He DS, Friedman P, Nakagawa H, Bruce C, Azegami K et al. A novel Mesh electrode catheter for mapping and radiofrequency delivery at the left atrium-pulmonary vein junction: A simplified approach to pulmonary vein isolation. J Cardiovasc Electrophysiol 2007; 18: 206-211.
    • (2007) J Cardiovasc Electrophysiol , vol.18 , pp. 206-211
    • Arruda, M.S.1    He, D.S.2    Friedman, P.3    Nakagawa, H.4    Bruce, C.5    Azegami, K.6
  • 14
    • 0033517860 scopus 로고    scopus 로고
    • Initiation of atrial fibrillation by ectopic beats originating from the pulmonary veins: Electrophysiological characteristics, pharmacological responses, and effects of radiofrequency ablation
    • Chen SA, Hsieh MH, Tai CT, Tsai CF, Prakash VS, Yu WC et al. Initiation of atrial fibrillation by ectopic beats originating from the pulmonary veins: Electrophysiological characteristics, pharmacological responses, and effects of radiofrequency ablation. Circulation 1999; 100: 1879-1886.
    • (1999) Circulation , vol.100 , pp. 1879-1886
    • Chen, S.A.1    Hsieh, M.H.2    Tai, C.T.3    Tsai, C.F.4    Prakash, V.S.5    Yu, W.C.6
  • 15
    • 0041730576 scopus 로고    scopus 로고
    • Pulmonary vein isolation using transvenous catheter cryoablation for treatment of atrial fibrillation without risk of pulmonary vein stenosis
    • Tse HF, Reek S, Timmermans C, Lee KL, Geller JC, Rodriguez LM et al. Pulmonary vein isolation using transvenous catheter cryoablation for treatment of atrial fibrillation without risk of pulmonary vein stenosis. J Am Coll Cardiol 2003;42: 752-758.
    • (2003) J Am Coll Cardiol , vol.42 , pp. 752-758
    • Tse, H.F.1    Reek, S.2    Timmermans, C.3    Lee, K.L.4    Geller, J.C.5    Rodriguez, L.M.6
  • 16
    • 34249298673 scopus 로고    scopus 로고
    • Time course of esophageal lesions after catheter ablation with cryothermal and radiofrequency ablation: Implication for atrio-esophageal fistula formation after catheter ablation for atrial fibrillation
    • Ripley KL, Gage AA, Olsen DB, Van Vleet JF, Lau CP, Tse HF. Time course of esophageal lesions after catheter ablation with cryothermal and radiofrequency ablation: implication for atrio-esophageal fistula formation after catheter ablation for atrial fibrillation. J Cardiovasc electrophysiol 2007;18: 642-646.
    • (2007) J Cardiovasc Electrophysiol , vol.18 , pp. 642-646
    • Ripley, K.L.1    Gage, A.A.2    Olsen, D.B.3    van Vleet, J.F.4    Lau, C.P.5    Tse, H.F.6
  • 17
    • 0037461289 scopus 로고    scopus 로고
    • Lower incidence of thrombus formation with cryoenergy versus radiofrequency catheter ablation
    • Khairy P, Chauvet P, Lehmann J, Lambert J, Macle L, Tanguay JF et al. Lower incidence of thrombus formation with cryoenergy versus radiofrequency catheter ablation. Circulation 2003;107: 2045-2050.
    • (2003) Circulation , vol.107 , pp. 2045-2050
    • Khairy, P.1    Chauvet, P.2    Lehmann, J.3    Lambert, J.4    Macle, L.5    Tanguay, J.F.6
  • 18
    • 44649124294 scopus 로고    scopus 로고
    • Efficacy of pulmonary vein isolation by cryoballoon ablation in patients with paroxysmal atrial fibrillation
    • Klein G, Oswald H, Gardiwal A, Lüsebrink U, Lissel C, Yu H et al. Efficacy of pulmonary vein isolation by cryoballoon ablation in patients with paroxysmal atrial fibrillation. Heart Rhythm 2008; 5: 802-6.
    • (2008) Heart Rhythm , vol.5 , pp. 802-806
    • Klein, G.1    Oswald, H.2    Gardiwal, A.3    Lüsebrink, U.4    Lissel, C.5    Yu, H.6
  • 19
    • 0032480265 scopus 로고    scopus 로고
    • Spontaneous initiation of atrial fibrillation by ectopic beats originating in the pulmonary veins
    • Haissaguerre M, Jais P, Shah DC, Takahashi A, Hocini M, Quiniou G et al. Spontaneous initiation of atrial fibrillation by ectopic beats originating in the pulmonary veins. N Engl J Med 1998; 339: 659-666.
    • (1998) N Engl J Med , vol.339 , pp. 659-666
    • Haissaguerre, M.1    Jais, P.2    Shah, D.C.3    Takahashi, A.4    Hocini, M.5    Quiniou, G.6
  • 21
    • 0037022841 scopus 로고    scopus 로고
    • Pulmonary vein isolation for paroxysmal and persistent atrial fibrillation
    • Oral H, Knight BP, Tada H, Ozaydin M, Chugh A, Hassan S et al. Pulmonary vein isolation for paroxysmal and persistent atrial fibrillation. Circulation. 2002; 105: 1077-1081.
    • (2002) Circulation , vol.105 , pp. 1077-1081
    • Oral, H.1    Knight, B.P.2    Tada, H.3    Ozaydin, M.4    Chugh, A.5    Hassan, S.6
  • 22
    • 0037172987 scopus 로고    scopus 로고
    • Electrical connections between pulmonary veins: Implications for ostial ablation of pulmonary veins in patients with atrial fibrillation
    • Takahashi A, Iesaka Y, Takahashi Y, Takahashi R, Kobayashi K, Takagi K et al. Electrical connections between pulmonary veins: implications for ostial ablation of pulmonary veins in patients with atrial fibrillation. Circulation. 2002;105: 2998-3003.
    • (2002) Circulation , vol.105 , pp. 2998-3003
    • Takahashi, A.1    Iesaka, Y.2    Takahashi, Y.3    Takahashi, R.4    Kobayashi, K.5    Takagi, K.6
  • 23
    • 0035923561 scopus 로고    scopus 로고
    • Atrial electroanatomical remodeling after circumferential radiofrequency pulmonary vein isolation: Efficacy of an anatomic approach in a large cohort of patients with atrial fibrillation
    • Pappone C, Oreto G, Rosanio S, Vicedomini G, Tocchi M, Gugliotta F et al. Atrial electroanatomical remodeling after circumferential radiofrequency pulmonary vein isolation: efficacy of an anatomic approach in a large cohort of patients with atrial fibrillation. Circulation. 2001;104: 2539-2544.
    • (2001) Circulation , vol.104 , pp. 2539-2544
    • Pappone, C.1    Oreto, G.2    Rosanio, S.3    Vicedomini, G.4    Tocchi, M.5    Gugliotta, F.6
  • 24
    • 0242694560 scopus 로고    scopus 로고
    • Catheter ablation for paroxysmal atrial fibrillation: Segmental pulmonary vein ostial ablation versus left atrial ablation
    • Oral H, Scharf C, Chugh A, Hall B, Cheung P, Good E et al. Catheter ablation for paroxysmal atrial fibrillation: segmental pulmonary vein ostial ablation versus left atrial ablation. Circulation. 2003;108: 2355-2360.
    • (2003) Circulation , vol.108 , pp. 2355-2360
    • Oral, H.1    Scharf, C.2    Chugh, A.3    Hall, B.4    Cheung, P.5    Good, E.6
  • 25
    • 0141615779 scopus 로고    scopus 로고
    • Catheter-induced linear lesions in the left atrium in patients with atrial fibrillation
    • Ernst S, Ouyang F, Löber F, Antz M, Kuck KH et al. Catheter-induced linear lesions in the left atrium in patients with atrial fibrillation. J Am Coll Cardiol. 2003;42: 1271-1282.
    • (2003) J Am Coll Cardiol , vol.42 , pp. 1271-1282
    • Ernst, S.1    Ouyang, F.2    Löber, F.3    Antz, M.4    Kuck, K.H.5
  • 26
    • 9144239215 scopus 로고    scopus 로고
    • Pulmonary vein denervation enhances long-term benefit after circumferential ablation for paroxysmal atrial fibrillation
    • Pappone C, Santinelli V, Manguso F, Vicedomini G, Gugliotta F, Augello G et al. Pulmonary vein denervation enhances long-term benefit after circumferential ablation for paroxysmal atrial fibrillation. Circulation. 2004;109: 327-334.
    • (2004) Circulation , vol.109 , pp. 327-334
    • Pappone, C.1    Santinelli, V.2    Manguso, F.3    Vicedomini, G.4    Gugliotta, F.5    Augello, G.6
  • 27
    • 78650683097 scopus 로고    scopus 로고
    • Pulmonary vein isolation with Mesh Ablator versus cryoballoon catheters: 6-month outcomes
    • Dec
    • Hofmann R, Hönig S, Leisch F, Steinwender C. Pulmonary vein isolation with Mesh Ablator versus cryoballoon catheters: 6-month outcomes. J Interv Card Electrophysiol. 2010 Dec;29(3): 179-85.
    • (2010) J Interv Card Electrophysiol , vol.29 , Issue.3 , pp. 179-185
    • Hofmann, R.1    Hönig, S.2    Leisch, F.3    Steinwender, C.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.