메뉴 건너뛰기




Volumn 105, Issue 2, 2012, Pages 167-173

A semiautomatic CT-based ensemble segmentation of lung tumors: Comparison with oncologists' delineations and with the surgical specimen

Author keywords

Auto segmentation; CT; Inter observer variability; NSCLC delineation

Indexed keywords

FLUORODEOXYGLUCOSE F 18;

EID: 84871292104     PISSN: 01678140     EISSN: 18790887     Source Type: Journal    
DOI: 10.1016/j.radonc.2012.09.023     Document Type: Article
Times cited : (95)

References (46)
  • 2
    • 77952298828 scopus 로고    scopus 로고
    • Meta-analysis of concomitant versus sequential radiochemotherapy in locally advanced non-small-cell lung cancer
    • A. Auperin, C. Le Pechoux, and E. Rolland Meta-analysis of concomitant versus sequential radiochemotherapy in locally advanced non-small-cell lung cancer J Clin Oncol 28 2010 2181 2190
    • (2010) J Clin Oncol , vol.28 , pp. 2181-2190
    • Auperin, A.1    Le Pechoux, C.2    Rolland, E.3
  • 3
    • 34848835514 scopus 로고    scopus 로고
    • Treatment of non-small cell lung cancer, stage IIIB: ACCP evidence-based clinical practice guidelines (2nd edition)
    • J.R. Jett, S.E. Schild, R.L. Keith, and K.A. Kesler Treatment of non-small cell lung cancer, stage IIIB: ACCP evidence-based clinical practice guidelines (2nd edition) Chest 132 2007 266S 276S
    • (2007) Chest , vol.132
    • Jett, J.R.1    Schild, S.E.2    Keith, R.L.3    Kesler, K.A.4
  • 4
    • 83955164326 scopus 로고    scopus 로고
    • A phase II comparative study of gross tumor volume definition with or without PET/CT fusion in dosimetric planning for non-small-cell lung cancer (NSCLC): Primary analysis of Radiation Therapy Oncology Group (RTOG) 0515
    • J. Bradley, K. Bae, and N. Choi A phase II comparative study of gross tumor volume definition with or without PET/CT fusion in dosimetric planning for non-small-cell lung cancer (NSCLC): primary analysis of Radiation Therapy Oncology Group (RTOG) 0515 Int J Radiat Oncol Biol Phys 82 2012 e431
    • (2012) Int J Radiat Oncol Biol Phys , vol.82 , pp. 431
    • Bradley, J.1    Bae, K.2    Choi, N.3
  • 5
    • 0036162284 scopus 로고    scopus 로고
    • Conformal radiotherapy for lung cancer: Different delineation of the gross tumor volume (GTV) by radiologists and radiation oncologists
    • P. Giraud, S. Elles, and S. Helfre Conformal radiotherapy for lung cancer: different delineation of the gross tumor volume (GTV) by radiologists and radiation oncologists Radiother Oncol 62 2002 27 36
    • (2002) Radiother Oncol , vol.62 , pp. 27-36
    • Giraud, P.1    Elles, S.2    Helfre, S.3
  • 7
    • 34447255709 scopus 로고    scopus 로고
    • Current status of PET/CT for tumour volume definition in radiotherapy treatment planning for non-small cell lung cancer (NSCLC)
    • C. Greco, K. Rosenzweig, G.L. Cascini, and O. Tamburrini Current status of PET/CT for tumour volume definition in radiotherapy treatment planning for non-small cell lung cancer (NSCLC) Lung Cancer 57 2007 125 134
    • (2007) Lung Cancer , vol.57 , pp. 125-134
    • Greco, C.1    Rosenzweig, K.2    Cascini, G.L.3    Tamburrini, O.4
  • 8
    • 27944454309 scopus 로고    scopus 로고
    • Observer variation in target volume delineation of lung cancer related to radiation oncologist-computer interaction: A 'Big Brother' evaluation
    • R.J. Steenbakkers, J.C. Duppen, and I. Fitton Observer variation in target volume delineation of lung cancer related to radiation oncologist-computer interaction: a 'Big Brother' evaluation Radiother Oncol 77 2005 182 190
    • (2005) Radiother Oncol , vol.77 , pp. 182-190
    • Steenbakkers, R.J.1    Duppen, J.C.2    Fitton, I.3
  • 9
    • 0036164338 scopus 로고    scopus 로고
    • Definition of gross tumor volume in lung cancer: Inter-observer variability
    • J. Van de Steene, N. Linthout, and J. de Mey Definition of gross tumor volume in lung cancer: inter-observer variability Radiother Oncol 62 2002 37 49
    • (2002) Radiother Oncol , vol.62 , pp. 37-49
    • Van De Steene, J.1    Linthout, N.2    De Mey, J.3
  • 10
    • 65749084489 scopus 로고    scopus 로고
    • The delineation of target volumes for radiotherapy of lung cancer patients
    • H. Vorwerk, G. Beckmann, and M. Bremer The delineation of target volumes for radiotherapy of lung cancer patients Radiother Oncol 91 2009 455 460
    • (2009) Radiother Oncol , vol.91 , pp. 455-460
    • Vorwerk, H.1    Beckmann, G.2    Bremer, M.3
  • 11
    • 0345580333 scopus 로고    scopus 로고
    • Evaluation of a target contouring protocol for 3D conformal radiotherapy in non-small cell lung cancer
    • S. Senan, J. Van Sornsen de Koste, and M. Samson Evaluation of a target contouring protocol for 3D conformal radiotherapy in non-small cell lung cancer Radiother Oncol 53 1999 247 255
    • (1999) Radiother Oncol , vol.53 , pp. 247-255
    • Senan, S.1    Van Sornsen De Koste, J.2    Samson, M.3
  • 12
    • 0036643959 scopus 로고    scopus 로고
    • Measurement of lung tumor volumes using three-dimensional computer planning software
    • P. Bowden, R. Fisher, and M. Mac Manus Measurement of lung tumor volumes using three-dimensional computer planning software Int J Radiat Oncol Biol Phys 53 2002 566 573
    • (2002) Int J Radiat Oncol Biol Phys , vol.53 , pp. 566-573
    • Bowden, P.1    Fisher, R.2    Mac Manus, M.3
  • 13
    • 0035889268 scopus 로고    scopus 로고
    • Observer variation in contouring gross tumor volume in patients with poorly defined non-small-cell lung tumors on CT: The impact of 18FDG-hybrid PET fusion
    • C.B. Caldwell, K. Mah, and Y.C. Ung Observer variation in contouring gross tumor volume in patients with poorly defined non-small-cell lung tumors on CT: the impact of 18FDG-hybrid PET fusion Int J Radiat Oncol Biol Phys 51 2001 923 931
    • (2001) Int J Radiat Oncol Biol Phys , vol.51 , pp. 923-931
    • Caldwell, C.B.1    Mah, K.2    Ung, Y.C.3
  • 14
    • 84857919314 scopus 로고    scopus 로고
    • FDG-PET-CT reduces the interobserver variability in rectal tumor delineation
    • J. Buijsen, J. van den Bogaard, and H. van der Weide FDG-PET-CT reduces the interobserver variability in rectal tumor delineation Radiother Oncol 102 2012 371 376
    • (2012) Radiother Oncol , vol.102 , pp. 371-376
    • Buijsen, J.1    Van Den Bogaard, J.2    Van Der Weide, H.3
  • 15
    • 30544446003 scopus 로고    scopus 로고
    • Reduction of observer variation using matched CT-PET for lung cancer delineation: A three-dimensional analysis
    • R.J. Steenbakkers, J.C. Duppen, and I. Fitton Reduction of observer variation using matched CT-PET for lung cancer delineation: a three-dimensional analysis Int J Radiat Oncol Biol Phys 64 2006 435 448
    • (2006) Int J Radiat Oncol Biol Phys , vol.64 , pp. 435-448
    • Steenbakkers, R.J.1    Duppen, J.C.2    Fitton, I.3
  • 16
    • 34249275726 scopus 로고    scopus 로고
    • PET-CT-based auto-contouring in non-small-cell lung cancer correlates with pathology and reduces interobserver variability in the delineation of the primary tumor and involved nodal volumes
    • A. van Baardwijk, G. Bosmans, and L. Boersma PET-CT-based auto-contouring in non-small-cell lung cancer correlates with pathology and reduces interobserver variability in the delineation of the primary tumor and involved nodal volumes Int J Radiat Oncol Biol Phys 68 2007 771 778
    • (2007) Int J Radiat Oncol Biol Phys , vol.68 , pp. 771-778
    • Van Baardwijk, A.1    Bosmans, G.2    Boersma, L.3
  • 17
    • 77956185538 scopus 로고    scopus 로고
    • Segmentation of positron emission tomography images: Some recommendations for target delineation in radiation oncology
    • J.A. Lee Segmentation of positron emission tomography images: some recommendations for target delineation in radiation oncology Radiother Oncol 96 2010 302 307
    • (2010) Radiother Oncol , vol.96 , pp. 302-307
    • Lee, J.A.1
  • 18
    • 25444452894 scopus 로고    scopus 로고
    • Comparison of different methods for delineation of 18F-FDG PET-positive tissue for target volume definition in radiotherapy of patients with non-Small cell lung cancer
    • U. Nestle, S. Kremp, and A. Schaefer-Schuler Comparison of different methods for delineation of 18F-FDG PET-positive tissue for target volume definition in radiotherapy of patients with non-Small cell lung cancer J Nucl Med 46 2005 1342 1348
    • (2005) J Nucl Med , vol.46 , pp. 1342-1348
    • Nestle, U.1    Kremp, S.2    Schaefer-Schuler, A.3
  • 19
    • 77952564033 scopus 로고    scopus 로고
    • PET CT thresholds for radiotherapy target definition in non-small-cell lung cancer: How close are we to the pathologic findings?
    • K. Wu, Y.C. Ung, and J. Hornby PET CT thresholds for radiotherapy target definition in non-small-cell lung cancer: how close are we to the pathologic findings? Int J Radiat Oncol Biol Phys 77 2009 699 706
    • (2009) Int J Radiat Oncol Biol Phys , vol.77 , pp. 699-706
    • Wu, K.1    Ung, Y.C.2    Hornby, J.3
  • 20
    • 78651357430 scopus 로고    scopus 로고
    • Gradient-based delineation of the primary GTV on FDG-PET in non-small cell lung cancer: A comparison with threshold-based approaches, CT and surgical specimens
    • M. Wanet, J.A. Lee, and B. Weynand Gradient-based delineation of the primary GTV on FDG-PET in non-small cell lung cancer: a comparison with threshold-based approaches, CT and surgical specimens Radiother Oncol 98 2010 117 125
    • (2010) Radiother Oncol , vol.98 , pp. 117-125
    • Wanet, M.1    Lee, J.A.2    Weynand, B.3
  • 21
    • 79957500028 scopus 로고    scopus 로고
    • Therapeutic implications of molecular imaging with PET in the combined modality treatment of lung cancer
    • J. van Loon, A. van Baardwijk, L. Boersma, M. Ollers, P. Lambin, and D. De Ruysscher Therapeutic implications of molecular imaging with PET in the combined modality treatment of lung cancer Cancer Treat Rev 37 2011 331 343
    • (2011) Cancer Treat Rev , vol.37 , pp. 331-343
    • Van Loon, J.1    Van Baardwijk, A.2    Boersma, L.3    Ollers, M.4    Lambin, P.5    De Ruysscher, D.6
  • 22
    • 77249113832 scopus 로고    scopus 로고
    • Adaptive radiotherapy for lung cancer
    • J.J. Sonke, and J. Belderbos Adaptive radiotherapy for lung cancer Semin Radiat Oncol 20 2010 94 106
    • (2010) Semin Radiat Oncol , vol.20 , pp. 94-106
    • Sonke, J.J.1    Belderbos, J.2
  • 23
    • 80052663995 scopus 로고    scopus 로고
    • X-ray computed tomography: Semiautomated volumetric analysis of late-stage lung tumors as a basis for response assessments
    • C. Bendtsen, M. Kiotzmann, R. Korn, P.D. Mozley, G. Schmidt, and G. Binnig X-ray computed tomography: semiautomated volumetric analysis of late-stage lung tumors as a basis for response assessments Int J Biomed Imaging 2011 2011 11
    • (2011) Int J Biomed Imaging , vol.2011 , pp. 11
    • Bendtsen, C.1    Kiotzmann, M.2    Korn, R.3    Mozley, P.D.4    Schmidt, G.5    Binnig, G.6
  • 24
    • 35349000784 scopus 로고    scopus 로고
    • Definiens cognition network technology-A novel multimodal image analysis technique for automatic identification and quantification of biological image contents
    • Springer New York, NY, USA
    • M. Athelogou, G. Schmidt, A. Schaepe, M. Baatz, and G. Binnig Definiens cognition network technology-a novel multimodal image analysis technique for automatic identification and quantification of biological image contents Imaging cellular and molecular biological functions 2007 Springer New York, NY, USA
    • (2007) Imaging Cellular and Molecular Biological Functions
    • Athelogou, M.1    Schmidt, G.2    Schaepe, A.3    Baatz, M.4    Binnig, G.5
  • 25
    • 84870248785 scopus 로고    scopus 로고
    • Automated delineation of lung tumors from CT images using a single click ensemble segmentation approach
    • In press
    • Gu, Y, Kumar, V, Hall, LO, et al. Automated delineation of lung tumors from CT images using a single click ensemble segmentation approach. Pattern Recognition 2012;In press.
    • (2012) Pattern Recognition
    • Gu, Y.1    Kumar, V.2    Hall, L.O.3
  • 26
    • 47149099230 scopus 로고    scopus 로고
    • Individualized radical radiotherapy of non-small-cell lung cancer based on normal tissue dose constraints: A feasibility study
    • A. van Baardwijk, G. Bosmans, and L. Boersma Individualized radical radiotherapy of non-small-cell lung cancer based on normal tissue dose constraints: a feasibility study Int J Radiat Oncol Biol Phys 71 2008 1394 1401
    • (2008) Int J Radiat Oncol Biol Phys , vol.71 , pp. 1394-1401
    • Van Baardwijk, A.1    Bosmans, G.2    Boersma, L.3
  • 27
    • 77950466471 scopus 로고    scopus 로고
    • Mature results of an individualized radiation dose prescription study based on normal tissue constraints in stages i to III non-small-cell lung cancer
    • A. van Baardwijk, S. Wanders, and L. Boersma Mature results of an individualized radiation dose prescription study based on normal tissue constraints in stages I to III non-small-cell lung cancer J Clin Oncol 28 2010 1380 1386
    • (2010) J Clin Oncol , vol.28 , pp. 1380-1386
    • Van Baardwijk, A.1    Wanders, S.2    Boersma, L.3
  • 28
    • 84871295571 scopus 로고    scopus 로고
    • Richtlijn Niet-kleincellig longcarcinoom: Stadiering en behandeling
    • Richtlijn Niet-kleincellig longcarcinoom: stadiering en behandeling. Vereniging van Integrale Kankercentra 2004. Available from: http://www.cbo.nl/ thema/Richtlijnen/Overzicht-richtlijnen/Oncologie/.
    • (2004) Vereniging Van Integrale Kankercentra
  • 29
    • 65649140133 scopus 로고    scopus 로고
    • Identification of residual metabolic-active areas within individual NSCLC tumours using a pre-radiotherapy (18)fluorodeoxyglucose-PET-CT scan
    • H.J. Aerts, A.A. van Baardwijk, and S.F. Petit Identification of residual metabolic-active areas within individual NSCLC tumours using a pre-radiotherapy (18)fluorodeoxyglucose-PET-CT scan Radiother Oncol 91 2009 386 392
    • (2009) Radiother Oncol , vol.91 , pp. 386-392
    • Aerts, H.J.1    Van Baardwijk, A.A.2    Petit, S.F.3
  • 30
    • 77955661537 scopus 로고    scopus 로고
    • Geometrical analysis of radiotherapy target volume delineation: A systematic review of reported comparison methods
    • G.G. Hanna, A.R. Hounsell, and J.M. O'Sullivan Geometrical analysis of radiotherapy target volume delineation: a systematic review of reported comparison methods Clin Oncol (R Coll Radiol) 22 2010 515 525
    • (2010) Clin Oncol (R Coll Radiol) , vol.22 , pp. 515-525
    • Hanna, G.G.1    Hounsell, A.R.2    O'Sullivan, J.M.3
  • 31
    • 33751250233 scopus 로고    scopus 로고
    • Practical integration of [18F]-FDG-PET and PET-CT in the planning of radiotherapy for non-small cell lung cancer (NSCLC): The technical basis, ICRU-target volumes, problems, perspectives
    • U. Nestle, S. Kremp, and A.L. Grosu Practical integration of [18F]-FDG-PET and PET-CT in the planning of radiotherapy for non-small cell lung cancer (NSCLC): the technical basis, ICRU-target volumes, problems, perspectives Radiother Oncol 81 2006 209 225
    • (2006) Radiother Oncol , vol.81 , pp. 209-225
    • Nestle, U.1    Kremp, S.2    Grosu, A.L.3
  • 32
    • 0345303828 scopus 로고    scopus 로고
    • Tri-dimensional automatic segmentation of PET volumes based on measured source-to-background ratios: Influence of reconstruction algorithms
    • J.F. Daisne, M. Sibomana, A. Bol, T. Doumont, M. Lonneux, and V. Gregoire Tri-dimensional automatic segmentation of PET volumes based on measured source-to-background ratios: influence of reconstruction algorithms Radiother Oncol 69 2003 247 250
    • (2003) Radiother Oncol , vol.69 , pp. 247-250
    • Daisne, J.F.1    Sibomana, M.2    Bol, A.3    Doumont, T.4    Lonneux, M.5    Gregoire, V.6
  • 33
    • 77950689496 scopus 로고    scopus 로고
    • Accurate automatic delineation of heterogeneous functional volumes in positron emission tomography for oncology applications
    • M. Hatt, C. Cheze le Rest, and P. Descourt Accurate automatic delineation of heterogeneous functional volumes in positron emission tomography for oncology applications Int J Radiat Oncol Biol Phys 77 2010 301 308
    • (2010) Int J Radiat Oncol Biol Phys , vol.77 , pp. 301-308
    • Hatt, M.1    Cheze Le Rest, C.2    Descourt, P.3
  • 34
    • 41649099132 scopus 로고    scopus 로고
    • Segmentation of pulmonary nodules in thoracic CT scans: A region growing approach
    • J. Dehmeshki, H. Amin, M. Valdivieso, and X. Ye Segmentation of pulmonary nodules in thoracic CT scans: a region growing approach IEEE Trans Med Imaging 27 2008 467 480
    • (2008) IEEE Trans Med Imaging , vol.27 , pp. 467-480
    • Dehmeshki, J.1    Amin, H.2    Valdivieso, M.3    Ye, X.4
  • 35
    • 0034845242 scopus 로고    scopus 로고
    • Automated detection of lung nodules in CT scans: Preliminary results
    • S.G. Armato 3rd, M.L. Giger, and H. MacMahon Automated detection of lung nodules in CT scans: preliminary results Med Phys 28 2001 1552 1561
    • (2001) Med Phys , vol.28 , pp. 1552-1561
    • Armato III, S.G.1    Giger, M.L.2    MacMahon, H.3
  • 36
    • 0032981748 scopus 로고    scopus 로고
    • A pattern classification approach to characterizing solitary pulmonary nodules imaged on high resolution CT: Preliminary results
    • M.F. McNitt-Gray, E.M. Hart, N. Wyckoff, J.W. Sayre, J.G. Goldin, and D.R. Aberle A pattern classification approach to characterizing solitary pulmonary nodules imaged on high resolution CT: preliminary results Med Phys 26 1999 880 888
    • (1999) Med Phys , vol.26 , pp. 880-888
    • McNitt-Gray, M.F.1    Hart, E.M.2    Wyckoff, N.3    Sayre, J.W.4    Goldin, J.G.5    Aberle, D.R.6
  • 37
    • 78649905395 scopus 로고    scopus 로고
    • CT tumor volume measurement in advanced non-small-cell lung cancer: Performance characteristics of an emerging clinical tool
    • M. Nishino, M. Guo, and D.M. Jackman CT tumor volume measurement in advanced non-small-cell lung cancer: performance characteristics of an emerging clinical tool Acad Radiol 18 2011 54 62
    • (2011) Acad Radiol , vol.18 , pp. 54-62
    • Nishino, M.1    Guo, M.2    Jackman, D.M.3
  • 38
    • 0034538087 scopus 로고    scopus 로고
    • Small pulmonary nodules: Volumetrically determined growth rates based on CT evaluation
    • D.F. Yankelevitz, A.P. Reeves, W.J. Kostis, B. Zhao, and C.I. Henschke Small pulmonary nodules: volumetrically determined growth rates based on CT evaluation Radiology 217 2000 251 256
    • (2000) Radiology , vol.217 , pp. 251-256
    • Yankelevitz, D.F.1    Reeves, A.P.2    Kostis, W.J.3    Zhao, B.4    Henschke, C.I.5
  • 39
    • 0141743729 scopus 로고    scopus 로고
    • Quantitative computerized analysis of diffuse lung disease in high-resolution computed tomography
    • Y. Uchiyama, S. Katsuragawa, and H. Abe Quantitative computerized analysis of diffuse lung disease in high-resolution computed tomography Med Phys 30 2003 2440 2454
    • (2003) Med Phys , vol.30 , pp. 2440-2454
    • Uchiyama, Y.1    Katsuragawa, S.2    Abe, H.3
  • 40
    • 78650752065 scopus 로고    scopus 로고
    • Automatic graph cut segmentation of lesions in CT using mean shift superpixels
    • X. Ye, G. Beddoe, and G. Slabaugh Automatic graph cut segmentation of lesions in CT using mean shift superpixels Int J Biomed Imaging 2010 983963
    • (2010) Int J Biomed Imaging , pp. 983963
    • Ye, X.1    Beddoe, G.2    Slabaugh, G.3
  • 41
    • 57449115730 scopus 로고    scopus 로고
    • Automatic segmentation and recognition of lungs and lesion from CT scans of thorax
    • M. Kakar, and D.R. Olsen Automatic segmentation and recognition of lungs and lesion from CT scans of thorax Comput Med Imaging Graph 33 2009 72 82
    • (2009) Comput Med Imaging Graph , vol.33 , pp. 72-82
    • Kakar, M.1    Olsen, D.R.2
  • 42
    • 34547850186 scopus 로고    scopus 로고
    • Feasibility of pathology-correlated lung imaging for accurate target definition of lung tumors
    • J. Stroom, H. Blaauwgeers, and A. van Baardwijk Feasibility of pathology-correlated lung imaging for accurate target definition of lung tumors Int J Radiat Oncol Biol Phys 69 2007 267 275
    • (2007) Int J Radiat Oncol Biol Phys , vol.69 , pp. 267-275
    • Stroom, J.1    Blaauwgeers, H.2    Van Baardwijk, A.3
  • 43
    • 4644240997 scopus 로고    scopus 로고
    • Tumor volume in pharyngolaryngeal squamous cell carcinoma: Comparison at CT, MR imaging, and FDG PET and validation with surgical specimen
    • J.F. Daisne, T. Duprez, and B. Weynand Tumor volume in pharyngolaryngeal squamous cell carcinoma: comparison at CT, MR imaging, and FDG PET and validation with surgical specimen Radiology 233 2004 93 100
    • (2004) Radiology , vol.233 , pp. 93-100
    • Daisne, J.F.1    Duprez, T.2    Weynand, B.3
  • 44
    • 77958473899 scopus 로고    scopus 로고
    • Atlas-based semiautomatic target volume definition (CTV) for head-and-neck tumors
    • G. Strassmann, S. Abdellaoui, and D. Richter Atlas-based semiautomatic target volume definition (CTV) for head-and-neck tumors Int J Radiat Oncol Biol Phys 78 2010 1270 1276
    • (2010) Int J Radiat Oncol Biol Phys , vol.78 , pp. 1270-1276
    • Strassmann, G.1    Abdellaoui, S.2    Richter, D.3
  • 45
    • 84455199709 scopus 로고    scopus 로고
    • Performance of an atlas-based autosegmentation software for delineation of target volumes for radiotherapy of breast and anorectal cancer
    • L.C. Anders, F. Stieler, K. Siebenlist, J. Schäfer, F. Lohr, and F. Wenz Performance of an atlas-based autosegmentation software for delineation of target volumes for radiotherapy of breast and anorectal cancer Radiother Oncol 102 2012 68 73
    • (2012) Radiother Oncol , vol.102 , pp. 68-73
    • Anders, L.C.1    Stieler, F.2    Siebenlist, K.3    Schäfer, J.4    Lohr, F.5    Wenz, F.6
  • 46
    • 41849128499 scopus 로고    scopus 로고
    • Evaluation of an atlas-based automatic segmentation software for the delineation of brain organs at risk in a radiation therapy clinical context
    • Al Isambert, Fdr Dhermain, and Fo Bidault Evaluation of an atlas-based automatic segmentation software for the delineation of brain organs at risk in a radiation therapy clinical context Radiother Oncol 87 2008 93 99
    • (2008) Radiother Oncol , vol.87 , pp. 93-99
    • Isambert, A.1    Dhermain, F.2    Bidault, F.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.