메뉴 건너뛰기




Volumn 120, Issue 2, 2013, Pages 141-143

The need for preclinical research on pelvic floor reconstruction

Author keywords

[No Author keywords available]

Indexed keywords

POLYPROPYLENE;

EID: 84871257539     PISSN: 14700328     EISSN: 14710528     Source Type: Journal    
DOI: 10.1111/1471-0528.12088     Document Type: Note
Times cited : (16)

References (23)
  • 1
    • 77956873794 scopus 로고    scopus 로고
    • Does mesh offer an advantage over tissue in the open repair of umbilical hernias? A systematic review and meta-analysis
    • [Meta-Analysis Review]
    • Aslani N, Brown CJ,. Does mesh offer an advantage over tissue in the open repair of umbilical hernias? A systematic review and meta-analysis. Hernia [Meta-Analysis Review] 2010; 14: 455-62.
    • (2010) Hernia , vol.14 , pp. 455-462
    • Aslani, N.1    Brown, C.J.2
  • 3
    • 84864715261 scopus 로고    scopus 로고
    • What's wrong with the debate on mesh surgery?
    • Dietz HP,. What's wrong with the debate on mesh surgery? Aust N Z J Obstet Gynaecol 2012; 52: 313-5.
    • (2012) Aust N Z J Obstet Gynaecol , vol.52 , pp. 313-315
    • Dietz, H.P.1
  • 4
    • 79955915043 scopus 로고    scopus 로고
    • Anterior colporrhaphy versus transvaginal mesh for pelvic-organ prolapse
    • Altman D, Vayrynen T, Engh ME, Axelsen S, Falconer C,. Anterior colporrhaphy versus transvaginal mesh for pelvic-organ prolapse. N Engl J Med 2011; 364: 1826-36.
    • (2011) N Engl J Med , vol.364 , pp. 1826-1836
    • Altman, D.1    Vayrynen, T.2    Engh, M.E.3    Axelsen, S.4    Falconer, C.5
  • 5
    • 34948874140 scopus 로고    scopus 로고
    • Risk factors for the recurrence of pelvic organ prolapse after vaginal surgery: A review at 5 years after surgery
    • DOI 10.1007/s00192-007-0321-0
    • Diez-Itza I, Aizpitarte I, Becerro A,. Risk factors for the recurrence of pelvic organ prolapse after vaginal surgery: a review at 5years after surgery. Int Urogynecol J Pelvic Floor Dysfunct 2007; 18: 1317-24. (Pubitemid 47521476)
    • (2007) International Urogynecology Journal and Pelvic Floor Dysfunction , vol.18 , Issue.11 , pp. 1317-1324
    • Diez-Itza, I.1    Aizpitarte, I.2    Becerro, A.3
  • 6
    • 84860677273 scopus 로고    scopus 로고
    • Transvaginal placement of surgical mesh for pelvic organ prolapse: More FDA concerns-positive reactions are possible
    • Haylen BT, Sand PK, Swift SE, Maher C, Moran PA, Freeman RM,. Transvaginal placement of surgical mesh for pelvic organ prolapse: more FDA concerns-positive reactions are possible. Int Urogynecol J 2012; 23: 11-3.
    • (2012) Int Urogynecol J , vol.23 , pp. 11-13
    • Haylen, B.T.1    Sand, P.K.2    Swift, S.E.3    Maher, C.4    Moran, P.A.5    Freeman, R.M.6
  • 7
    • 78049339658 scopus 로고    scopus 로고
    • Lifetime risk of undergoing surgery for pelvic organ prolapse
    • Smith FJ, Holman CD, Moorin RE, Tsokos N,. Lifetime risk of undergoing surgery for pelvic organ prolapse. Obstet Gynecol 2010; 116: 1096-100.
    • (2010) Obstet Gynecol , vol.116 , pp. 1096-1100
    • Smith, F.J.1    Holman, C.D.2    Moorin, R.E.3    Tsokos, N.4
  • 8
    • 84863113036 scopus 로고    scopus 로고
    • A standardized description of graft-containing meshes and recommended steps before the introduction of medical devices for prolapse surgery: Consensus of the 2nd IUGA Grafts Roundtable: Optimizing Safety and Appropriateness of Graft Use in Transvaginal Pelvic Reconstructive Surgery
    • Slack M, Ostergard D, Cervigni M, Deprest J,. A standardized description of graft-containing meshes and recommended steps before the introduction of medical devices for prolapse surgery: consensus of the 2nd IUGA Grafts Roundtable: Optimizing Safety and Appropriateness of Graft Use in Transvaginal Pelvic Reconstructive Surgery. Int Urogynecol J 2012; 23 (Suppl 1): 15-26.
    • (2012) Int Urogynecol J , vol.23 , Issue.SUPPL. 1 , pp. 15-26
    • Slack, M.1    Ostergard, D.2    Cervigni, M.3    Deprest, J.4
  • 9
    • 72149088464 scopus 로고    scopus 로고
    • The perils of commercially driven surgical innovation
    • Wall LL, Brown D,. The perils of commercially driven surgical innovation. Am J Obstet Gynecol 2010; 202: 30.e1-4.
    • (2010) Am J Obstet Gynecol , vol.202
    • Wall, L.L.1    Brown, D.2
  • 12
    • 34247109543 scopus 로고    scopus 로고
    • Cytokine production following experimental implantation of xenogenic dermal collagen and polypropylene grafts in mice
    • DOI 10.1002/nau.20317
    • Zheng F, Xu L, Verbiest L, Verbeken E, De Ridder D, Deprest J,. Cytokine production following experimental implantation of xenogenic dermal collagen and polypropylene grafts in mice. Neurourol Urodyn 2007; 26: 280-9. (Pubitemid 46595731)
    • (2007) Neurourology and Urodynamics , vol.26 , Issue.2 , pp. 280-289
    • Zheng, F.1    Xu, L.2    Verbiest, L.3    Verbeken, E.4    De Ridder, D.5    Deprest, J.6
  • 14
    • 64249121696 scopus 로고    scopus 로고
    • Long-term histologic response to synthetic and biologic graft materials implanted in the vagina and abdomen of a rabbit model
    • Pierce LM, Rao A, Baumann SS, Glassberg JE, Kuehl TJ, Muir TW,. Long-term histologic response to synthetic and biologic graft materials implanted in the vagina and abdomen of a rabbit model. Am J Obstet Gynecol 2009; 200: 546.e1-8.
    • (2009) Am J Obstet Gynecol , vol.200
    • Pierce, L.M.1    Rao, A.2    Baumann, S.S.3    Glassberg, J.E.4    Kuehl, T.J.5    Muir, T.W.6
  • 15
    • 84868367418 scopus 로고    scopus 로고
    • Biomechanical effects of polyglecaprone fibers in a polypropylene mesh after abdominal and rectovaginal implantation in a rabbit
    • Ozog Y, Mazza E, De Ridder D, Deprest J,. Biomechanical effects of polyglecaprone fibers in a polypropylene mesh after abdominal and rectovaginal implantation in a rabbit. Int Urogynecol J 2012; 19: 1397-402.
    • (2012) Int Urogynecol J , vol.19 , pp. 1397-1402
    • Ozog, Y.1    Mazza, E.2    De Ridder, D.3    Deprest, J.4
  • 16
    • 34147149174 scopus 로고    scopus 로고
    • Collagen-coated vs noncoated low-weight polypropylene meshes in a sheep model for vaginal surgery. A pilot study
    • DOI 10.1007/s00192-006-0176-9
    • de Tayrac R, Alves A, Therin M,. Collagen-coated vs noncoated low-weight polypropylene meshes in a sheep model for vaginal surgery. A pilot study. Int Urogynecol J Pelvic Floor Dysfunct 2007; 18: 513-20. (Pubitemid 46554195)
    • (2007) International Urogynecology Journal and Pelvic Floor Dysfunction , vol.18 , Issue.5 , pp. 513-520
    • Tayrac, R.1    Alves, A.2    Therin, M.3
  • 17
    • 84871186458 scopus 로고    scopus 로고
    • Graft-related complications and biaxial tensiometry following experimental vaginal implantation of flat mesh of variable dimensions
    • Manodoro S, Endo M, Uvin P, Albersen M, Vláčil J, Engels A, Schmidt B, De Ridder D, Feola A, Deprest J,. Graft-related complications and biaxial tensiometry following experimental vaginal implantation of flat mesh of variable dimensions. BJOG 2013; 120: 244-50.
    • (2013) BJOG , vol.120 , pp. 244-250
    • Manodoro, S.1    Endo, M.2    Uvin, P.3    Albersen, M.4    Vláčil, J.5    Engels, A.6    Schmidt, B.7    De Ridder, D.8    Feola, A.9    Deprest, J.10
  • 18
    • 84855447216 scopus 로고    scopus 로고
    • Is degradable antibiotic coating for synthetic meshes provide protection against experimental animal infection after fascia repair?
    • Letouzey V, Lavigne JP, Garric X, Coudane J, de Tayrac R, Callaghan DO,. Is degradable antibiotic coating for synthetic meshes provide protection against experimental animal infection after fascia repair? J Biomed Mater Res B Appl Biomater 2011; 100: 471-9.
    • (2011) J Biomed Mater Res B Appl Biomater , vol.100 , pp. 471-479
    • Letouzey, V.1    Lavigne, J.P.2    Garric, X.3    Coudane, J.4    De Tayrac, R.5    Callaghan, D.O.6
  • 20
    • 70350565371 scopus 로고    scopus 로고
    • Effect of estrogen replacement on the histologic response to polypropylene mesh implanted in the rabbit vagina model
    • Higgins EW, Rao A, Baumann SS, James RL, Kuehl TJ, Muir TW, etal. Effect of estrogen replacement on the histologic response to polypropylene mesh implanted in the rabbit vagina model. Am J Obstet Gynecol 2009; 201: 505.e1-9.
    • (2009) Am J Obstet Gynecol , vol.201
    • Higgins, E.W.1    Rao, A.2    Baumann, S.S.3    James, R.L.4    Kuehl, T.J.5    Muir, T.W.6
  • 23
    • 33745233049 scopus 로고    scopus 로고
    • High Rate of Vaginal Erosions Associated With the Mentor ObTape™
    • DOI 10.1016/j.juro.2006.03.064, PII S0022534706008275
    • Yamada BS, Govier FE, Stefanovic KB, Kobashi KC,. High rate of vaginal erosions associated with the mentor ObTape. J Urol 2006; 176: 651-4; discussion 4. (Pubitemid 43927926)
    • (2006) Journal of Urology , vol.176 , Issue.2 , pp. 651-654
    • Yamada, B.S.1    Govier, F.E.2    Stefanovic, K.B.3    Kobashi, K.C.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.