메뉴 건너뛰기




Volumn 60, Issue , 2013, Pages 126-136

Thermal comfort and energy performance of a low-mixing ceiling-mounted personalized ventilator system

Author keywords

Energy efficiency; Localized ventilation; Personalized ventilation; Thermal comfort

Indexed keywords

AIRCONDITIONING SYSTEMS; BIO-HEAT; BODY PARTS; CFD MODELS; CLEAN AIR; COAXIAL NOZZLES; ENERGY PERFORMANCE; EXTENSIVE SIMULATIONS; FRESH AIR; MICROENVIRONMENTS; MIXING SYSTEM; NOZZLE SUPPLY; NUMERICAL VALUES; PERSONALIZED VENTILATION; ROOM AIR; SUBJECTIVE ASSESSMENTS; VENTILATOR SYSTEMS;

EID: 84871161929     PISSN: 03601323     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.buildenv.2012.11.016     Document Type: Article
Times cited : (48)

References (33)
  • 1
    • 12444308228 scopus 로고    scopus 로고
    • Dynamic model of an HVAC system for control analysis
    • Bourhan T., Molhim M., Al-Rousan M. Dynamic model of an HVAC system for control analysis. Energy 2005, 30(10):1729-1745.
    • (2005) Energy , vol.30 , Issue.10 , pp. 1729-1745
    • Bourhan, T.1    Molhim, M.2    Al-Rousan, M.3
  • 2
    • 55949110506 scopus 로고    scopus 로고
    • Review of research on air-conditioning systems and indoor air quality control for human health
    • Yu B.F., Hu Z.B., Liu M., Yang H.L., Kong Q.X., Liu Y.H. Review of research on air-conditioning systems and indoor air quality control for human health. Int J Refrigeration 2009, 32(1):3-20.
    • (2009) Int J Refrigeration , vol.32 , Issue.1 , pp. 3-20
    • Yu, B.F.1    Hu, Z.B.2    Liu, M.3    Yang, H.L.4    Kong, Q.X.5    Liu, Y.H.6
  • 4
    • 13244276348 scopus 로고    scopus 로고
    • Comparison of performances of displacement and mixing ventilations. Part I: thermal comfort
    • Zhang L., Chow T., Fong K., Wang Q., Li Y. Comparison of performances of displacement and mixing ventilations. Part I: thermal comfort. Int J Refrigeration 2005, 28(2):276-287.
    • (2005) Int J Refrigeration , vol.28 , Issue.2 , pp. 276-287
    • Zhang, L.1    Chow, T.2    Fong, K.3    Wang, Q.4    Li, Y.5
  • 5
    • 13244294117 scopus 로고    scopus 로고
    • Comparison of performances of displacement and mixing ventilations. Part II: indoor air quality
    • Zhang L., Chow T., Fong K., Tsang C., Wang Q. Comparison of performances of displacement and mixing ventilations. Part II: indoor air quality. Int J Refrigeration 2005, 28(2):288-305.
    • (2005) Int J Refrigeration , vol.28 , Issue.2 , pp. 288-305
    • Zhang, L.1    Chow, T.2    Fong, K.3    Tsang, C.4    Wang, Q.5
  • 6
    • 78049456089 scopus 로고    scopus 로고
    • Comparison of annual energy performances with different ventilation methods for cooling
    • Zhang L., Lee C., Fong S., Chow T., Yao T., Chan A. Comparison of annual energy performances with different ventilation methods for cooling. Energ Build 2001, 43(1):130-136.
    • (2001) Energ Build , vol.43 , Issue.1 , pp. 130-136
    • Zhang, L.1    Lee, C.2    Fong, S.3    Chow, T.4    Yao, T.5    Chan, A.6
  • 7
    • 80755128150 scopus 로고    scopus 로고
    • Comparison of annual energy performances with different ventilation methods for temperature and humidity control
    • Zhang L., Lee C., Fong K., Chow T. Comparison of annual energy performances with different ventilation methods for temperature and humidity control. Energ Build 2011, 43(12):3599-3608.
    • (2011) Energ Build , vol.43 , Issue.12 , pp. 3599-3608
    • Zhang, L.1    Lee, C.2    Fong, K.3    Chow, T.4
  • 8
    • 71649111211 scopus 로고    scopus 로고
    • Performance of " ductless" personalized ventilation in conjunction with displacement ventilation: Impact of intake height
    • Halvonova B., Melikov A. Performance of " ductless" personalized ventilation in conjunction with displacement ventilation: Impact of intake height. Build Environ 2010, 45(4):996-1005.
    • (2010) Build Environ , vol.45 , Issue.4 , pp. 996-1005
    • Halvonova, B.1    Melikov, A.2
  • 9
    • 77952675955 scopus 로고    scopus 로고
    • Thermal comfort and IAQ assessment of under-floor air distribution system integrated with personalized ventilation in hot and humid climate
    • Li R., Sekhar S., Melikov A. Thermal comfort and IAQ assessment of under-floor air distribution system integrated with personalized ventilation in hot and humid climate. Build Environ 2010, 45(9):1906-1913.
    • (2010) Build Environ , vol.45 , Issue.9 , pp. 1906-1913
    • Li, R.1    Sekhar, S.2    Melikov, A.3
  • 10
    • 0031618729 scopus 로고    scopus 로고
    • A critical review of displacement ventilation
    • Yuan X., Chen Q., Glicksman L. A critical review of displacement ventilation. ASHRAE Trans 2001, 4101(RP-949):78-90.
    • (2001) ASHRAE Trans , vol.4101 RP , Issue.949 , pp. 78-90
    • Yuan, X.1    Chen, Q.2    Glicksman, L.3
  • 11
    • 84871608439 scopus 로고    scopus 로고
    • Thermal comfort and indoor air quality evaluation of a ceiling mounted personalized ventilation system integrated with an ambient mixing ventilation system. PhD thesis, National University of Singapore.
    • Yang B. Thermal comfort and indoor air quality evaluation of a ceiling mounted personalized ventilation system integrated with an ambient mixing ventilation system. PhD thesis, National University of Singapore; 2009.
    • (2009)
    • Yang, B.1
  • 12
    • 77957696517 scopus 로고    scopus 로고
    • Ceiling mounted personalized ventilation system in hot and humid climate - an energy analysis
    • Yang B., Chandra S., Melikov A. Ceiling mounted personalized ventilation system in hot and humid climate - an energy analysis. Energ Build 2010, 42:2304-2308.
    • (2010) Energ Build , vol.42 , pp. 2304-2308
    • Yang, B.1    Chandra, S.2    Melikov, A.3
  • 13
    • 85197013508 scopus 로고    scopus 로고
    • Ceiling-mounted personalized ventilator system for occupant-controlled microenvironment. In: Proceedings of IMECE2012, the ASME 2012 international mechanical engineering congress and exposition. Houston, Texas:(Paper ID: 87565).
    • Makhoul A, Ghali K, Ghaddar N. Ceiling-mounted personalized ventilator system for occupant-controlled microenvironment. In: Proceedings of IMECE2012, the ASME 2012 international mechanical engineering congress and exposition. Houston, Texas: 2012 (Paper ID: 87565).
    • (2012)
    • Makhoul, A.1    Ghali, K.2    Ghaddar, N.3
  • 14
    • 33846571766 scopus 로고    scopus 로고
    • A new transient bioheat model of the human body and its integration to clothing models
    • Salloum M., Ghaddar N., Ghali K. A new transient bioheat model of the human body and its integration to clothing models. Int J Thermal Sci 2007, 46:371-384.
    • (2007) Int J Thermal Sci , vol.46 , pp. 371-384
    • Salloum, M.1    Ghaddar, N.2    Ghali, K.3
  • 15
    • 77953535495 scopus 로고    scopus 로고
    • A new simplified thermoregulatory bioheat model for evaluating thermal response of the human body to transient environments
    • Zolfaghari A., Maerefat M. A new simplified thermoregulatory bioheat model for evaluating thermal response of the human body to transient environments. Build Environ 2010, 45(10):2068-2076.
    • (2010) Build Environ , vol.45 , Issue.10 , pp. 2068-2076
    • Zolfaghari, A.1    Maerefat, M.2
  • 16
    • 0036859573 scopus 로고    scopus 로고
    • Global bioheat model for quick evaluation of the human physiological thermal profiles under differing conditions
    • Chiok Y.H., Ng E.Y.K., Kulish V.V. Global bioheat model for quick evaluation of the human physiological thermal profiles under differing conditions. J Med Eng Technol 2002, 26(6):231-238.
    • (2002) J Med Eng Technol , vol.26 , Issue.6 , pp. 231-238
    • Chiok, Y.H.1    Ng, E.Y.K.2    Kulish, V.V.3
  • 17
    • 53049090047 scopus 로고    scopus 로고
    • A multi-segmented human bioheat model for transient and asymmetric radiative environments
    • Al-Othmani M., Ghaddar N., Ghali K. A multi-segmented human bioheat model for transient and asymmetric radiative environments. Int J Heat Mass Transfer 2008, 51(23):5522-5533.
    • (2008) Int J Heat Mass Transfer , vol.51 , Issue.23 , pp. 5522-5533
    • Al-Othmani, M.1    Ghaddar, N.2    Ghali, K.3
  • 18
    • 70249131865 scopus 로고    scopus 로고
    • Comfort, perceived air quality, and work performance in a low-power task-ambient conditioning system
    • Zhang H., Arens E., Kim D., BuchBerger E., Bauman F., Huizanga C. Comfort, perceived air quality, and work performance in a low-power task-ambient conditioning system. Build Environ 2010, 45(1):29-39.
    • (2010) Build Environ , vol.45 , Issue.1 , pp. 29-39
    • Zhang, H.1    Arens, E.2    Kim, D.3    BuchBerger, E.4    Bauman, F.5    Huizanga, C.6
  • 19
    • 70350163024 scopus 로고    scopus 로고
    • Thermal sensation and comfort models for non-uniform and transient environments: Part I: local sensation of individual body parts
    • Zhang H., Arens E., Huizenga C., Han T. Thermal sensation and comfort models for non-uniform and transient environments: Part I: local sensation of individual body parts. Build Environ 2010, 45(2):380-388.
    • (2010) Build Environ , vol.45 , Issue.2 , pp. 380-388
    • Zhang, H.1    Arens, E.2    Huizenga, C.3    Han, T.4
  • 20
    • 70350137955 scopus 로고    scopus 로고
    • Thermal sensation and comfort models for non-uniform and transient environments: Part II: local comfort of individual body parts
    • Zhang H., Arens E., Huizenga C., Han T. Thermal sensation and comfort models for non-uniform and transient environments: Part II: local comfort of individual body parts. Build Environ 2010, 45(2):389-398.
    • (2010) Build Environ , vol.45 , Issue.2 , pp. 389-398
    • Zhang, H.1    Arens, E.2    Huizenga, C.3    Han, T.4
  • 21
    • 70350524977 scopus 로고    scopus 로고
    • Thermal sensation and comfort models for non-uniform and transient environments: Part III: whole-body sensation and comfort
    • Zhang H., Arens E., Huizenga C., Han T. Thermal sensation and comfort models for non-uniform and transient environments: Part III: whole-body sensation and comfort. Build Environ 2010, 45(2):399-410.
    • (2010) Build Environ , vol.45 , Issue.2 , pp. 399-410
    • Zhang, H.1    Arens, E.2    Huizenga, C.3    Han, T.4
  • 22
    • 80053331212 scopus 로고    scopus 로고
    • Chilled ceiling and displacement ventilation aided with personalized evaporative cooler: thermal comfort and energy savings
    • Chakroun W., Ghaddar N., Ghali K. Chilled ceiling and displacement ventilation aided with personalized evaporative cooler: thermal comfort and energy savings. Energ Build 2011, 43(11):3250-3257.
    • (2011) Energ Build , vol.43 , Issue.11 , pp. 3250-3257
    • Chakroun, W.1    Ghaddar, N.2    Ghali, K.3
  • 23
    • 80053297463 scopus 로고    scopus 로고
    • Assessing thermal comfort of active people in transitional spaces in presence of air movement
    • Ghaddar N., Ghali K., Chehaitly S. Assessing thermal comfort of active people in transitional spaces in presence of air movement. Energ Build 2011, 43(10):2832-2842.
    • (2011) Energ Build , vol.43 , Issue.10 , pp. 2832-2842
    • Ghaddar, N.1    Ghali, K.2    Chehaitly, S.3
  • 24
    • 84871618439 scopus 로고    scopus 로고
    • ANSYS Software. ANSYS Inc.
    • ANSYS Software. ANSYS Inc. http://www.ansys.com/.
  • 25
    • 0022947869 scopus 로고
    • A standard predictive index of human response to the thermal environment
    • Gagge A.P., Fobelets A.P., Berglund L.G. A standard predictive index of human response to the thermal environment. ASHRAE Trans 1986, 92(2).
    • (1986) ASHRAE Trans , vol.92 , Issue.2
    • Gagge, A.P.1    Fobelets, A.P.2    Berglund, L.G.3
  • 26
    • 79952191497 scopus 로고    scopus 로고
    • American Society of Heating Air-conditioning and Refrigeration Engineers, Inc., Atlanta
    • ASHRAE ASHRAE handbook-fundamentals 2009, American Society of Heating Air-conditioning and Refrigeration Engineers, Inc., Atlanta.
    • (2009) ASHRAE ASHRAE handbook-fundamentals
  • 29
    • 78650299646 scopus 로고    scopus 로고
    • Simulation of honeycomb-screen combinations for turbulence management in a subsonic wind tunnel
    • Kulkarni V., Sahoo N., Chavan S. Simulation of honeycomb-screen combinations for turbulence management in a subsonic wind tunnel. J Wind Eng Ind Aerodynamics 2011, 99:37-45.
    • (2011) J Wind Eng Ind Aerodynamics , vol.99 , pp. 37-45
    • Kulkarni, V.1    Sahoo, N.2    Chavan, S.3
  • 31
    • 61449142695 scopus 로고    scopus 로고
    • Linking indoor environment conditions to job satisfaction: a field study
    • Newsham G., Brand J., Donnelly C., Veitch J., Aries M., Charles K. Linking indoor environment conditions to job satisfaction: a field study. Build Res Inf 2009, 37(2):129-147.
    • (2009) Build Res Inf , vol.37 , Issue.2 , pp. 129-147
    • Newsham, G.1    Brand, J.2    Donnelly, C.3    Veitch, J.4    Aries, M.5    Charles, K.6
  • 32
    • 70249112570 scopus 로고    scopus 로고
    • Air movement acceptability limits and thermal comfort in Brazil's hot humid climate zone
    • de Dear Cândido R.J., Lamberts R., Bittencourt L. Air movement acceptability limits and thermal comfort in Brazil's hot humid climate zone. Build Environ 2010, 45(1):222-229.
    • (2010) Build Environ , vol.45 , Issue.1 , pp. 222-229
    • de Dear Cândido, R.J.1    Lamberts, R.2    Bittencourt, L.3
  • 33
    • 34547938336 scopus 로고    scopus 로고
    • Investigation of transient thermal environments
    • Zhao R. Investigation of transient thermal environments. Build Environ 2007, 42:3926-3932.
    • (2007) Build Environ , vol.42 , pp. 3926-3932
    • Zhao, R.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.